Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Prosthodont ; 33(3): 259-265, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36918297

RESUMO

PURPOSE: To assess the changes in intrapulpal temperature between electric high-speed handpieces of different coolant functions ('Water Jet' and 'Water Spray'), coolant port designs (1- and 4-port), suction use, and bur and tooth types using an experimental in vitro setup. MATERIALS AND METHODS: Forty-four extracted anterior and posterior teeth were collected. A total of 18 groove cuts (n = 18/coolant port spray design, bur and tooth type group) and 12 groove cuts (n = 12/tooth type and suction use) were completed, with a total of 264 groove cuts. Real-time temperature and duration were recorded at 1-s intervals throughout the preparation process using a thermocouple and digital data logger setup (GFX Data Logger Series and EL USB-TC; Lascar Electronics Inc., USA), and the data retrieved using EasyLog Software (EasyLog USB; Lascar Electronics Inc., USA). Statistical analysis was performed (SPSS V.27) for the change in temperature using the analysis of variance and post hoc analysis. RESULTS: The majority of the specimen cuts, regardless of tooth (anterior or posterior) and bur (diamond or carbide) types, handpiece coolant port design, and suction use showed an overall decreasing trend in intrapulpal temperature. No cuts caused a mean temperature change that reached the critical temperature of 42.5°C or resulted in an overall increase in intrapulpal temperature when the 60-s duration was completed. CONCLUSIONS: The tested electric handpieces efficiently reduced intrapulpal temperature, with the majority displaying a decreasing trend. A greater decrease in intrapulpal temperature was observed in canines compared to premolars; carbide burs compared to diamond; and with no suction preparations compared to when suction was used.


Assuntos
Equipamentos Odontológicos de Alta Rotação , Polpa Dentária , Temperatura , Diamante , Água
2.
Clin Oral Investig ; 27(5): 2277-2297, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37022531

RESUMO

INTRODUCTION: Heat is generated and transferred to the dentine-pulp complex during various dental procedures, such as from friction during cavity preparations, exothermic reactions during the polymerisation of restorative materials and when polishing restorations. For in vitro studies, detrimental effects are possible when intra-pulpal temperature increases by more than 5.5°C (that is, the intra-pulpal temperature exceeds 42.4°C). This excessive heat transfer results in inflammation and necrosis of the pulp. Despite numerous studies stating the importance of heat transfer and control during dental procedures, there are limited studies that have quantified the significance. Past studies incorporated an experimental setup where a thermocouple is placed inside the pulp of an extracted human tooth and connected to an electronic digital thermometer. METHODS: This review identified the opportunity for future research and develop both the understanding of various influencing factors on heat generation and the different sensor systems to measure the intrapulpal temperature. CONCLUSION: Various steps of dental restorative procedures have the potential to generate considerable amounts of heat which can permanently damage the pulp, leading to pulp necrosis, discoloration of the tooth and eventually tooth loss. Thus, measures should be undertaken to limit pulp irritation and injury during procedures. This review highlighted the gap for future research and a need for an experimental setup which can simulate pulp blood flow, temperature, intraoral temperature and intraoral humidity to accurately simulate the intraoral conditions and record temperature changes during various dental procedures.


Assuntos
Temperatura Alta , Dente , Humanos , Temperatura , Polpa Dentária , Assistência Odontológica
3.
J Prosthodont ; 32(2): 108-115, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35405767

RESUMO

PURPOSE: To perform a systematic review that provides an overview of the current literature on fatigue behavior of removable partial denture (RPD) clasp materials based on different retentive areas. MATERIALS AND METHODS: The review followed the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines. Electronic searches were done via PubMed, Scopus, and OVID for studies reporting on RPD clasps and the fatigue failure of clasp materials. Inclusion criteria were English language with full text and in vitro studies only. Exclusion criteria were studies that did not assess the fatigue of RPD clasp materials. A quality assessment and selection of full-text articles were performed according to Consolidated Standards of Reporting Trials criteria. RESULTS: A total of 182 articles were initially identified and screened. After applying inclusion and exclusion criteria, 15 articles were selected for the final analysis. Seven of the included studies utilized a vertical insertion/removal testing approach. Ten studies used the constant deflection test. Three studies used untapered specimens, and 12 studies used tapered specimens. Ten studies performed post-test analysis. CONCLUSIONS: Cobalt-chromium (CoCr) is the strongest material in terms of fatigue in relation to the undercut depth and the modern, digitally manufactured RPD clasp materials also exhibit comparable fatigue behavior. Recent RPD clasp materials such as polyetheretherketone (PEEK) or laser sintered CoCr, however, require further study in terms of their fatigue behavior. In order to improve the quality of future studies, a standardized and calibrated fatigue testing method is needed with standardized specimen size and shape, which will reduce the risk of bias and enable meta-analysis for bulk comparison between studies.


Assuntos
Ligas de Cromo , Prótese Parcial Removível , Grampos Dentários , Retenção de Dentadura , Teste de Materiais
4.
Int J Dent Hyg ; 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37680139

RESUMO

AIMS: To investigate the efficiency and abrasiveness of air-polishing on different types of denture base acrylic resins and whether air-polishing can be an effective technique to clean dentures chairside. MATERIALS AND METHODS: A total of 60 specimens were prepared (n = 20/group); heat-polymerized polymethyl methacrylate (PMMA) (G1), subtractive manufacturing (SM) (G2) and additive manufacturing (AM) denture base resins (G3). Equal number of specimens in each group were stained with permanent marker or nail polish and pumice mixture to mimic calcified biofilm. All specimens were treated using EMS Airflow® Prophylaxis Master with two different powders; erythritol or sodium bicarbonate powder, following manufacturer instructions. Efficacy of the powders and surface roughness of the specimens were measured. Scanning electron microscopy imaging was captured for qualitative observation. RESULTS: The highest efficacy for stain removal was found in erythritol powder on G1 (98.06% ± 1.304%). The lowest was found in the erythritol powder on G3 (91.83% ± 3.611%). The highest efficacy for biofilm removal was found in sodium bicarbonate powder on G3 (71.49% ± 8.607%), and the lowest was found in erythritol powder on G2 (11.64% ± 4.68%). Only AM resins had statistically significant increases in surface roughness with the use of erythritol powder (p < 0.001). The use of sodium bicarbonate powder significantly increases surface roughness of heat-polymerized (p < 0.025) and AM resins (p < 0.724). CONCLUSIONS: Air-polishing technology has shown to be effective and suitable for cleaning dentures. The sodium bicarbonate powder showed superior efficacy in cleaning dentures compared to the erythritol powder. Both powders show varyingly increase roughness depending on denture resin.

5.
J Prosthodont ; 31(5): 385-398, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34516027

RESUMO

PURPOSE: To systematically review past studies to determine the effect of various solutions on the color of denture teeth, thus answering the question in regards to which type of denture teeth has the best optical properties after exposure to various solutions. The method of measuring the color of artificial teeth was also evaluated as a secondary outcome. MATERIALS AND METHODS: A search of studies that quantitatively investigated the influence of immersion solutions on the color change of denture teeth was conducted. Ovid MEDLINE, PubMed and Scopus databases were searched from 1997 to April 2021. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used during article selection. Data regarding the effect of immersion solutions, accelerated aging and surface treatments on color change were gathered. Methodologies used to assess optical properties were also summarized and compared. The modified CONSORT checklist was used to determine the risk of bias of past studied included in this review. RESULTS: One hundred thirty-three studies were identified after removing duplicates. Forty-one studies were selected for full-text analysis, and 35 remaining papers met the inclusion criteria and were therefore included in this systematic review. Thirty-two in vitro studies and 3 in vivo studies were included in the review. All studies reported that immersion in various solutions has a significant influence on the change in color and optical properties of denture teeth. However, the discoloration of denture teeth is still clinically acceptable in most studies. Exposure to various solutions also affected the translucency parameter of denture teeth. Most studies also investigated the surface roughness and hardness along with the optical properties, and reported that immersion cycles did not cause changes in surface roughness of denture teeth, while hardness was affected. The optical properties of PMMA denture teeth have been studied extensively, whereas that of CAD/CAM and 3D printed denture teeth is limited. CONCLUSIONS: Color stability of CAD/CAM milled denture teeth is comparable to conventional PMMA denture teeth. There are contradictory findings in terms of color stability of 3D printed denture teeth as compared to conventional PMMA denture teeth. Staining by coffee is worst among the common beverages and solutions investigated. Denture teeth can show color changes after immersion in staining beverages as early as one week. The degree of discoloration of denture teeth after immersion is time dependent, with the larger extent in the initial phase.


Assuntos
Resinas Acrílicas , Polimetil Metacrilato , Cor , Teste de Materiais , Propriedades de Superfície
6.
J Prosthodont ; 31(6): 472-487, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34516696

RESUMO

PURPOSE: To systematically review studies on various materials and methods used for wear testing of occlusal devices and their antagonists in vitro and in vivo. METHODS: An electronic search in OVID, Web of Science, PubMed and Scopus was conducted using the following terms (MeSH words) with any synonyms and closed terms: "Splint*" OR "occlusal splint*" OR "night guard" OR "occlusal device" OR "occlusal devices" OR "deprogrammer" OR "bite splint" OR "bite plane" OR "orthotic appliance*" OR "orthotic devices" AND "wear" OR "two-body wear" OR "three-body wear" OR "tooth wear" OR "wear measurement*" OR "wear behaviour" OR "wear behavior" OR "abrasion" AND "Polymethyl Methacrylate" OR "PMMA" OR "acrylic resin*" OR "dental material*" OR "dental enamel" OR "CAD" OR "CAM" OR "PEEK" OR "material* testing". Database search was limited to English-language publications and published between 2001 and 1st of September 2021. A further hand search was done to ensure all materials were captured. RESULTS: After the removal of duplicates, 115 studies were identified, and 11 were chosen for review. Studies showed that the lowest volumetric loss was observed in PEEK occlusal device materials, whereas heat-cure, CAD-milled, and 3D printed occlusal device materials had no significant difference in wear. Vacuum-formed materials showed the highest wear among all groups. Testing parameters were found to be inconsistent across all studies. CONCLUSION: There is a need for standardization of in vitro and in vivo wear measurement and testing protocols as this study revealed a wide variety of testing protocols which potentially could influence the outcome. Polishing procedures are required for the material. Limited studies are available on 3D printed occlusal device materials and would therefore require further investigation, especially on printing build angles and settings. Further clinical studies would be advantageous to provide guidance on the selection of the best occlusal device material that would last the longest without remake.


Assuntos
Placas Oclusais , Desgaste dos Dentes , Resinas Acrílicas , Humanos , Teste de Materiais , Polimetil Metacrilato
7.
Graefes Arch Clin Exp Ophthalmol ; 259(8): 2431-2440, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33661364

RESUMO

PURPOSE: To compare 1-year visual outcomes after implantable collamer lens V4c (EVO-ICL) implantation and small incision lenticule extraction (SMILE) for moderate myopia. METHODS: In this retrospective study, 67 eyes of 39 patients with a preoperative manifest refraction spherical equivalent between - 3.00 and - 6.00 diopters (D) were selected from a database of SMILE and ICL implantation procedures performed from April 2018 to December 2018. Thirty-two eyes of 20 patients underwent EVO-ICL implantation, and 35 eyes of 19 patients underwent SMILE. At the routine 1-year follow-up appointment, all selected patients were examined for higher-order ocular aberrations, retinal image quality, and a quality of vision (QoV) questionnaire. This data was then analyzed. RESULTS: No complications were observed. Uncorrected and corrected visual acuities at 1 year after surgery were - 0.13 ± 0.07 and - 0.15 ± 0.06 logMAR in the SMILE group, and - 0.10 ± 0.07 and - 0.16 ± 0.05 logMAR in the ICL group. Twenty-nine eyes (90.6%) which underwent ICL implantation and 34 eyes (97.1%) which underwent SMILE were within ± 0.5 D of the attempted spherical equivalent (P = 0.49). Changes in coma after ICL were significantly less than after SMILE (P = 0.002). The leading complaints after ICL and SMILE were halos (84.4%) and blurred vision (65.7%), respectively. CONCLUSIONS: Both SMILE and ICL implantation provided good safety, efficacy, and predictability in correcting moderate myopia. The subjective visual complaints consisted mainly of halos after ICL and starbursts and blurred vision after SMILE.


Assuntos
Miopia , Seguimentos , Humanos , Miopia/cirurgia , Refração Ocular , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual
8.
Ophthalmic Res ; 64(2): 224-229, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32485706

RESUMO

OBJECTIVE: The aim of this study was to determine the prevalence of preoperative dry eye disease and evaluate tear film function in refractive surgery candidates in China. METHODS: In this prospective noninterventional cross-sectional study, refractive surgical candidates from 13 preselected eye hospitals in China were recruited from July 2015 to February 2016. Patient histories, subjective symptoms, tear film breakup time (TBUT), ocular surface fluorescein staining, and Schirmer I tests (SIT), were assessed to conduct subgroup analysis. RESULTS: A total of 1,849 patients were recruited, 41.4% were diagnosed with dry eye disease (766/1,849) and 44.9% (830/1,849) of subjects had a positive history of contact lens (CL) wear. The overall mean TBUT and SIT values were 7.3 ± 3.7 s and 15.2 ± 8.8 mm, respectively. The total prevalence of ocular surface fluorescein staining was 23.46% (422/1,849); 44.62% of patients had TBUT <5 s and 23.20% of patients had SIT <5 mm. CL wearers were observed to have a higher prevalence of dry eye than non-CL wearers (54.1 vs. 35.2%, OR = 2.17, 95% CI: 1.77-2.65). CONCLUSIONS: In this study, the most common abnormal finding in dry eye disease was tear film instability. A high proportion of refractive surgery candidates have preexisting dry eye disease and a history of CL wear prior to surgery. Careful attention should be given to the evaluation of preoperative dry eye in refractive surgery candidates.


Assuntos
Síndromes do Olho Seco/epidemiologia , Procedimentos Cirúrgicos Refrativos/efeitos adversos , Adolescente , Adulto , China/epidemiologia , Estudos Transversais , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Adulto Jovem
9.
J Prosthet Dent ; 126(2): 224-230, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32893016

RESUMO

STATEMENT OF PROBLEM: Direct-metal laser-sintering (DMLS) technologies are being used to manufacture removable partial denture frameworks; however, the build parameters are not well documented. PURPOSE: The purpose of this in vitro study was to investigate the impact of 3 different build angulations on a dental cobalt-chromium (Sint-Tech ST2724G) alloy by comparing the tensile properties and nanoindentation hardness. The null hypothesis was that no change would be found in the tensile properties of the different build angulation groups. MATERIAL AND METHODS: Dumbbell-shaped tensile specimens were produced by using stereolithographic models in accordance with American Society for Testing and Materials testing standard E8/E8M-16ae1. Specimens (n=10) were fabricated by using DMLS additive manufacturing with 3 different angulations (0, 45, and 90 degrees). Tensile testing was carried out to assess yield strength (0.2% permanent offset), elongation (%) at failure, and ultimate tensile strength (GPa). Scanning electron microscope (SEM) images were used to analyze the fracture surfaces. One 10×10×10 mm cube specimen at each orientation was prepared, and nanoindentation was used to determine hardness and elastic modulus. One-way ANOVA was used to evaluate the overall effects with interaction between groups and post hoc testing applied where the interaction was statistically significant (α=.05). RESULTS: The 45-degree build angulation resulted in the lowest mean elastic modulus of 213.3 GPa and the highest tensile strength of 1180.9 MPa. The 90-degree build angulation resulted in the highest mean elongation of 10.6% and the highest elastic modulus of 234.0 MPa. Within comparison of the different angulations indicated that various groups had statistically significant differences (P<.05). The SEM analysis indicated different fracture topography among the different build angles. CONCLUSIONS: The cobalt-chromium dental alloy manufactured by DMLS produced favorable mechanical properties. The SEM analysis combined with the tensile test results suggest that the direction of the build angle in relation to the laser melt pattern does impact the mechanical properties of the alloy.


Assuntos
Prótese Parcial Removível , Cromo , Ligas de Cromo , Cobalto , Humanos , Lasers , Teste de Materiais , Propriedades de Superfície , Resistência à Tração
10.
J Prosthodont ; 30(1): 83-90, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33215778

RESUMO

PURPOSE: To measure the adhesion of the denture characterizing composite to heat-cured, CAD/CAM and 3D printed denture base resins. METHODS AND MATERIALS: Two different denture characterizing composites with different viscosities (SR Nexco; high viscosity (SR) and Kulzer Cre-active; low viscosity (K)) and three denture base resins (Heat cure, CAD-milled and 3D printed) were investigated. 60 beams (25 × 4 × 3 mm) were fabricated for each denture base resin; 30 were bonded to SR and 30 to K to form a beam 50 × 4 × 3 mm. These were further divided (n = 10/group) to simulate the effects of 0, 6, and 12 months intraorally via thermocycling. The beams were subjected to a 4-point bend test using the chevron-notched beam method. Fracture toughness K1C (MPa ·m1/2 ) and flexural bond strength (MPa) were calculated. All specimens were analyzed for the mode of failure under the light microscope and selected specimens under scanning electron microscope. Results were statistically analyzed using ANOVA (SPSS Ver 25). RESULTS: The mean K1C was highest for the SR composite bonded to the heat-cured denture resin group (0.28 ± 0.11), followed by CAD/CAM (0.18 ± 0.04) and 3D printed groups (0.23 ± 0.16). Differences were not statistically significant (p = 0.268). Within each group, aging showed no statistical significance between the mean K1C and flexural bond strength (p = 0.209). The mean K1C for the K composites bonded to the three different denture bases were significantly lower compared to the SR group (p < 0.001). The mean K1C for the heat-cured denture resin group was (0.21 ± 0.1), followed by CAD/CAM (0.13 ± 0.04) and 3D printed groups (0.03 ± 0.02). Within each of the K group, aging showed a statistical significance for both the mean K1C and flexural bond strength (p = 0.002). CONCLUSION: The high viscosity SR showed significantly higher K1C and flexural bond strength to the lower viscosity K when bonded to heat-cured, CAD-milled and 3D printed denture base resins. Heat-cured denture base resins produced the highest K1C and flexural bond strength when bonded to two different types of characterizing composites.


Assuntos
Bases de Dentadura , Temperatura Alta , Resinas Compostas , Resistência à Flexão , Teste de Materiais , Impressão Tridimensional , Propriedades de Superfície
11.
J Esthet Restor Dent ; 32(7): 662-672, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32715619

RESUMO

OBJECTIVE: To determine patient satisfaction with esthetics, phonetics, and function following implant-supported fixed restorative treatment in the esthetic zone by measuring the Oral Health Related Quality of Life (OHRQoL). MATERIALS AND METHODS: This systematic review follows the "Preferred reporting items for systematic review and meta-analysis protocols" (PRISMA-P) 2015 statement. Studies were searched in the databases Ovid, PubMed, Web of Science, Scopus, and the Cochrane Library. The quality of the studies included in the review was scored using the GRADE system. The impact of the findings was analyzed by calculating effect size and standardization of results across different OHRQoL measurements was achieved by calculating the percentage equivalent. RESULTS: A total of 13 studies were selected to be included in his systematic review after application of the inclusion criteria. A total of six studies recorded pre- and post-treatment OHRQoL results, while the remaining seven studies provided only post-treatment results. CONCLUSIONS: This review concluded that implant-supported fixed restorations in the esthetic zone have an overall positive impact on OHRQoL. However, patient satisfaction from this treatment reduced as the number of missing teeth replaced by implants was increased. CLINICAL SIGNIFICANCE: When implant-supported fixed restorations are being planned in the esthetic zone, dentists need to consider the patient's perception and the subsequent impact of these restorations on the patient's quality of life. Clinicians can be assured that patient OHRQoL will increase; however, clinicians should also keep in mind the importance of the gingival frame. Furthermore, they should be aware of the challenges when planning cases with larger numbers of implants in the esthetic zone as this could lead to a lowering of a patient QoL.


Assuntos
Implantes Dentários , Satisfação do Paciente , Prótese Dentária Fixada por Implante , Estética Dentária , Humanos , Fonética , Qualidade de Vida
12.
J Prosthodont ; 29(5): 415-421, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31697004

RESUMO

PURPOSE: To establish the fracture toughness (K1C ) and flexural bond strength of commercially available denture teeth to heat cured, CAD/CAM and 3D printed denture-based resins (DBRs). MATERIALS AND METHODS: Three types of DBRs (Heat cure, CAD-milled and 3D printed) and four different types of commercial denture teeth (Unfilled PMMA, double cross-linked PMMA, PMMA with nanofillers and 3D printed resin teeth) were investigated. DBR and epoxy embedded denture teeth (n = 30 per group) specimen beams (25 × 4 × 3 mm) were fabricated. The testing ends of all the specimens were surface treated, bonded and processed according to manufacturer's instructions. Twenty specimens were thermal cycled to simulate the effects of 6 and 12 months intraorally. A 4-point bend test, using the chevron-notched beam method was done and K1C (MPa ·m1/2 ) and flexure bond strength (MPa) were calculated. All specimens were analysed for the mode of failure under the light microscope and selected specimens under scanning electron microscope. Results were statistically analysed using ANOVA (SPSS Ver 24). RESULTS: The mean K1C was the highest for the teeth bonded to the heat-cured DBR group (1.09 ± 0.24), followed by CAD/CAM (0.43 ± 0.05) and 3D printed groups (0.17 ± 0.01). Differences were statistically significant (p < 0.01). Within each group, aging showed statistically significantly lower values but no statistical significance between the mean K1C and flexural bond strength (p = 0.36). The dominant mode of failure was cohesive in the CAD/CAM groups and adhesive in the heat-cured and 3D printed groups. CONCLUSION: Teeth bonded to heat-cured DBRs produced the highest K1C .The bond strength decreased significantly with aging. Teeth bonded to CAD/CAM and 3D printed DBRs showed significantly lower bond strength, with no significant influence of aging.


Assuntos
Colagem Dentária , Polimetil Metacrilato , Resinas Acrílicas , Bases de Dentadura , Temperatura Alta , Teste de Materiais , Impressão Tridimensional , Propriedades de Superfície
13.
J Dent ; 144: 104873, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38316198

RESUMO

OBJECTIVES: This study aimed to investigate the effect of post-washing duration and crown thickness on the bond strength between additively manufactured crown materials and dental cement in vitro. METHODS: Rectangular-shaped specimens of two thicknesses (1.5 and 2.0 mm) were additively manufactured from permanent VarseoSmile Crown (VC) and long-term temporary NextDent (ND) materials. The specimens were post-washed (n = 160) in ethanol for 5 min, 10 min, 1 h, and 8 h then cemented with dual-cure resin cement. Twenty PMMA (TC) were milled as a control. A chevron-notch test was performed to measure the maximum load until failure (N). Interfacial bond strength (J/m2) was calculated and statistically analysed. The mode of failure was analysed by scanning electron microscopy (SEM). RESULTS: There was a significant difference in the bond strength between all groups (p < 0.01). VC at 1.5mm thickness post-washed for 10 min showed the highest mean bond strength (1.77 ±0.96 J/m2) while VC at 2.0mm thickness post-washed for 8 h showed the lowest (0.22 ±0.10 J/m2). Exposure to ethanol for 8 h resulted in lower bond strength. Within the type of material, there were no differences in bond strength between the thicknesses when post-washed for the same duration. CONCLUSIONS: Prolonged post-washing of AM crown materials can significantly decrease the bond strength to resin cement. There were no differences between the permanent and long-term temporary AM materials. When post-washed for 5 min, AM materials observed comparable or higher bond strength values compared to PMMA. CLINICAL SIGNIFICANCE: The output of this research serves as a guide for dental practitioners, emphasising the importance of adhering to correct post-washing procedures for optimal bond strength of additively manufactured crown materials.


Assuntos
Coroas , Colagem Dentária , Etanol , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina , Etanol/química , Cimentos de Resina/química , Fatores de Tempo , Humanos , Análise do Estresse Dentário , Propriedades de Superfície , Polimetil Metacrilato/química , Materiais Dentários/química , Estresse Mecânico , Cimentação/métodos
14.
J Dent ; 147: 105120, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38857647

RESUMO

OBJECTIVES: To evaluate the wear resistance of three additively manufactured dental crown materials (NextDent C&B MFH, Saremco print CROWNTEC and Bego VarseoSmile Crown) under two environmental conditions (dry and artificial saliva), two loads (49 N and 70 N) and two surface treatments (polished and glazed). METHODS: A total of 120 specimens were divided into 24 groups and tested for wear under two loads (49 N and 70 N), surface treatment (polished or glazed), and environment (dry or submerged in artificial saliva). All samples underwent reciprocating wear testing at 1 Hz using a wear simulator, replicating 48 months of In Vivo conditions with a stainless-steel ball as the antagonist. The coefficient of friction (CoF), surface roughness, volumetric and vertical wear loss were measured and statistically analysed. Confocal microscopy assessed the surface properties of crown materials and the antagonists. RESULTS: The NextDent material demonstrated the most homogenous wear, with relatively low vertical and volumetric loss across all groups (p < 0.004). NextDent and Bego materials performed similarly in artificial saliva regardless of the load type (p > 1.000). The CoF remained below 0.3 for all groups. All groups exhibited significant increases in surface roughness after testing, however, this did not correlate with an increase in the CoF. Confocal analysis revealed material deformities due to load and notable scratch marks on the stainless-steel antagonists. CONCLUSION: It was found that all investigated addtively manufactured materials can be suggested for provisional use. Both vertical loss and volumetric loss results should be included for material evaluation. CoF and surface roughness should be implemented into wear evaluation. CLINICAL SIGNIFICANCE: This study highlights the practical value of additively manufactured dental crown materials, particularly for provisional restorations. However, their extended use requires careful consideration of individual patient needs, emphasising the need for judicious clinical application evaluation.

15.
J Dent ; 144: 104908, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38432351

RESUMO

OBJECTIVE: The purpose of this systematic review was to investigate how different interventions can impact the bond strength of additively manufactured crown materials after cementation. DATA/SOURCES: Four online databases Ovid MEDLINE, Scopus, Web of Science and Google Scholar were searched up to January 2023. Inclusion criteria were English-language publications, full-text, and in vitro studies only. Exclusion criteria were studies that did not assess the bonding of an additively manufactured crown material to cement or did not conduct any bond strength tests. An assessment of risk of bias was done in accordance with a modified Consolidated Standards of Reporting Trials (CONSORT) checklist. Each study was analysed and compared based on the interventions and bond strength results. STUDY SELECTION: Six studies satisfied the inclusion and exclusion criteria, five of which evaluated photopolymerised resin and one that tested zirconia manufacturing via 3D printing. All studies observed a low risk of bias. The interventions applied included the type of surface pretreatments, airborne-particle abrasion pressure, cement type, taper of crown, and artificial aging. Three studies compared the bonding performance to milled materials. CONCLUSIONS: The bond strength of crown materials additively manufactured from photopolymers presented high values and are comparable to milled materials. The systematic review demonstrated there was no definite superior cement type, but airborne-particle abrasion with alumina was generally recommended. There is a clear gap in the literature regarding the bond strength of additively manufactured crowns. Therefore, further research is necessary to evaluate its clinical applicability for permanent restorations. CLINICAL SIGNIFICANCE: Factors influencing the bond strength of additively manufactured crown materials should be evaluated so dental professionals can adopt procedures that promote the strongest bond.


Assuntos
Coroas , Colagem Dentária , Humanos , Materiais Dentários/química , Teste de Materiais , Cimentos Dentários/química , Zircônio/química , Propriedades de Superfície , Cimentação/métodos , Impressão Tridimensional , Análise do Estresse Dentário , Técnicas In Vitro
16.
J Mech Behav Biomed Mater ; 150: 106314, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38113824

RESUMO

OBJECTIVES: To perform a systematic review that provides an overview of the current literature on the influence of different post-processing methods on the accuracy of additive-manufactured (3D-printed) photopolymer crown materials, and whether more research is needed. MATERIALS AND METHODS: The search used three online databases, Ovid (MEDLINE), Scopus and Web of Science which were screen for publications that involved assessing dimensional accuracy in post-processing of 3D printed dental crown materials. Publications that were literature reviews, abstracts, written in a language different from English, or publications that did not assess dimensional accuracy were excluded. RESULTS: The included articles were published between 1995 and 2023. After the removal of duplicates using Endnote, 135 studies remained for further screening, 13 were selected for full-text analysis, and 7 studies were included in the systematic review. A total of 7 articles were examined and categorised based on several factors, such as the type of material, number of specimens per group, print layer thickness, print angle of specimens, 3D printer used, properties of the specimens studied, and the method of analysing the accuracy of the specimens. CONCLUSION: It was found that post-processing washing times outside the prescribed instruction for use (IFU) may have an impact on the physical and biocompatibility characteristics of the material. Studies focusing on inert mediums during post-processing require more detailed investigation. The use of different post-curing conditions does not significantly affect the materials dimensional accuracy.


Assuntos
Coroas , Impressão Tridimensional
17.
Oral Maxillofac Surg ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38797786

RESUMO

PURPOSE: To explore the ability of Dental Students (DS), Medical Students (MS), Trainee Interns (TI) and Pre-vocational Junior Doctors (JD) in identifying procedures performed by Oral and Maxillofacial Surgery (OMS), the scope of practice (SOP) of OMS and ability to differentiate OMS from similar specialities. METHODS: The study included 282 complete responses to a survey consisting of: 9 demographic questions, 11 OMS awareness, professional ambition, teaching and exposure, confidence in identifying and referring questions and 70 procedural/scenario questions across four domains. Collected data was qualitatively and statistically analysed using SPSS V29. RESULTS: OMS awareness was limited. 92.2% reported None to Small amount of OMS teaching and exposure during university, with 66.0% preferring to have had a Fair to Significant amount. DS experienced more than medical respondents (2.1 vs. 1.5, p < 0.001). Most respondents reported No to Low confidence in identifying the SOP and procedures performed by OMS (67.7%) and referring to OMS (62.4%) compared to similar specialities (32.4% and 33.2%, respectively). 52.9% of procedures performed by OMS were correctly identified as being performed by OMS. The ability to identify the OMS SOP (8.7%) and differentiate OMS from similar specialities (5.0%) was low, however better among DS than medical respondents (14.9% vs. 6.3%, p = 0.002 and 12.2% vs. 2.2%, p < 0.001). CONCLUSION: The study has highlighted a deficit in the understanding of OMS with potential implications in the public and private healthcare sector. Identification of procedures, OMS SOP and ability to differentiate OMS from similar specialities is limited however slightly better among DS.

18.
J Dent ; 144: 104942, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38494044

RESUMO

OBJECTIVES: This study endeavours to investigate the effect of printing orientation on the trueness of additively manufactured molar zirconia crowns. The areal surface roughness and the characteristics of the marginal regions of the crowns were also considered. METHODS: Twelve molar crowns were manufactured at 0°, 45°, and, 90° printing orientations in a Lithoz and AON zirconia printer, respectively. Twelve milled crowns were used as a comparison. Samples were scanned and analysed in metrology software to determine the trueness of the groups. Regions of interest were defined as the margins, intaglio surface and contact points. Areal surface roughness and print layer thickness were further analysed using a confocal laser scanning microscope. RESULTS: The results indicate that there are clear differences between the investigated desktop (AON) and industrial (Lithoz) 3D printer. The 45° Lithoz group is the only sample group showing no significantly different results in trueness for all regions analysed compared to the milled group. Areal surface roughness analysis indicates that the print layers in the marginal regions are within clinically tolerable limits and surface characteristics. CONCLUSIONS: The printing orientation for zirconia crowns is critical to trueness, and differences are evident between different AM apparatuses. Considerations for design and orientation between different apparatuses should therefore be considered when utilising direct additive manufacturing processes. The areal surface roughness of the marginal regions is within acceptable clinical limits for all manufacturing processes and print orientations considered. CLINICAL SIGNIFICANCE: The materials and apparatuses for additive manufacturing of zirconia crowns are now clinically acceptable from the perspective of the trueness of a final crown for critical functional surfaces and areal surface roughness of the marginal regions.


Assuntos
Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária , Impressão Tridimensional , Propriedades de Superfície , Zircônio , Zircônio/química , Humanos , Materiais Dentários/química , Microscopia Confocal , Dente Molar , Teste de Materiais , Adaptação Marginal Dentária
19.
Biomater Investig Dent ; 10(1): 2258919, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37753304

RESUMO

Objective: To investigate the properties (tensile strength, roughness, abrasiveness) of different dental flosses and how these properties relate to subjective preference for floss by users. Materials and method: Four flosses of differing compositions were selected (polytetrafluoroethylene (PTFE), nylon, silk, and ultra-high-molecular-weight polyethylene (UHMWPE)). Tensile strength (TS) was measured utilising a universal testing machine (total n = 40). Surface roughness (Ra) was measured on 3D reconstructed models of scanning electron microscope and abrasiveness was measured through block-on-ring tests against human enamel. Subjective preference for floss was measured by asking a sample of 16 individuals to use each floss for an 8-day period using a split-mouth design. Results: The highest TS was found in UHMWPE floss (194.18±24.61 MPa) while the lowest TS was found in PTFE floss (11.78±0.77 MPa). Silk floss had the highest Ra (0.304±0.025 µm) while PTFE floss had the lowest (0.048±0.003 µm). In-vitro abrasion testing of the flosses identified no significant differences between the flosses in causing wear on tooth enamel. Subjective ratings of flosses indicated PTFE floss to be most preferred and nylon floss to be least preferred. Conclusion: There was a difference in subjective preference between dental flosses composed of different materials. The PTFE floss was the overall most preferred while the nylon floss was the least preferred. There was also an association between the mechanical properties and preference for their usage, with PTFE floss being the most preferred but having the lowest surface roughness and tensile strength. Clinical Relevance: This study compared a wide range of mechanical properties and subject preferences of commercially available dental floss. The results of this study can provide guidance for the recommendation of dental floss for oral hygiene routines.

20.
J Mech Behav Biomed Mater ; 140: 105688, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36753847

RESUMO

OBJECTIVES: To measure and compare the accuracy of 3D-printed materials used for RPD production to improve workflow and eliminate errors in manufacturing. METHODS: A partially edentulous maxilla (Kennedy Class III, modification 1) was prepared and designed with proximal plates, rest seats and clasps in one first premolar, one canine and two second molars. A total of 540 3D printed RPD frameworks were 3D printed with three different types of resin (DentaCAST (Asiga, Australia), SuperCAST (Asiga, Australia) and NextDent (3D Systems, Netherlands)). To evaluate the trueness of the printing materials, they were printed with three types of layer thickness: 50 µm, 75 µm and 100 µm, using two types of build angles: 0° and 45° and three types of plate locations: side, middle and corner. After production, all specimens were scanned and superimposed with a control sample that was digitally designed. Using the initial alignment and best-fit alignment method, the root mean square error (RMSE) was calculated. To capture region specific discrepancy, 10 points of XYZ internal discrepancy within RPDs were measured and Euclidean error was calculated. Data was statistically analysed using Shapiro-Wilk and Kruskal-Wallis tests, one-way ANOVA and T-test (SPSS Version 29) and MATLAB (R2022b). RESULTS: Optimal results were found using 45°, middle of the build plate and layer thicknesses of 100 µm (115 ± 19 µm, DentaCAST), 75 µm (143 ± 14 µm, NextDent), 50 µm (98 ± 35 µm, SuperCAST), which were clinically acceptable. Results were statistically significant when comparing layer thickness in each testing group (p < 0.001). Layer thickness was a primary parameter in the determination of print accuracy among all materials (p < 0.001). Higher discrepancies and failures were observed in 0° prints. No statistically significant difference was found in material usage between build angles or layer thickness (p > 0.005). CONCLUSIONS: All three 3D printing materials exhibited clinically acceptable RMSE results with a build angle of 45° with a printing layer thickness of 50 µm for SuperCAST, 75 µm NextDent and 100 µm for DentaCAST. The highest discrepancies were mostly found in posterior clasps, while the lowest discrepancy was found in palatal straps. Despite unoptimized spacing of prints, frameworks configured to print in the middle of the build plate result in the least printing failures.


Assuntos
Desenho Assistido por Computador , Prótese Parcial , Impressão Tridimensional , Análise de Variância , Placas Ósseas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA