Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Emerg Med ; 62: 62-68, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36272188

RESUMO

PURPOSE: To investigate the accuracy and total assessment time (TAT) of the "All-in-one" (AIO)-window/level setting for whole-body computed tomography (CT) image compared to multiple tissue-specific window/level settings conventionally used for detection of traumatic injuries. METHOD: Contrast-enhanced chest, abdomen, and pelvic CT scans of 50 patients who presented to our emergency department (ED) for major trauma were retrospectively selected. In a simulation of a "wet read" performed at the CT scanner console, 6 readers with different levels of experience had up to 3 min to describe any traumatic finding identified on the CTs. The readers reviewed each patient in two different sessions separated by a washout period to suppress any recall bias from one session to the next. Each scan was reviewed once using the AIO-window/level setting and another time using the conventional bone, lung, and soft tissue window/level display settings, in a randomized order. The CT reports were used as reference standard. RESULTS: Overall, there was no statistically significant difference in the assessment accuracy of the review based on the AIO or the conventional window/level settings (0.89 ± 0.09 vs 0.90 ± 0.08). Using the AIO-window/level settings, TAT was 14.3 s faster when compared with the conventional window/level settings (2.33 ± 0.63 vs 2.57 ± 0.51 min; p < 0.001). CONCLUSIONS: In a time-delimited image review, similar diagnostic accuracy was reached faster using the AIO vs the conventional window/level settings. When providing a "wet read" at the CT console, the ability to identify traumatic injury using a single AIO-window/level may help expedite patient management.


Assuntos
Tomografia Computadorizada por Raios X , Imagem Corporal Total , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Tórax , Abdome
2.
Ann Neurol ; 83(6): 1186-1197, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29740862

RESUMO

OBJECTIVE: To characterize [11 C]-PBR28 brain uptake using positron emission tomography (PET) in people with amyotrophic lateral sclerosis (ALS) and primary lateral sclerosis (PLS). We have previously shown increased [11 C]-PBR28 uptake in the precentral gyrus in a small group of ALS patients. Herein, we confirm our initial finding, study the longitudinal changes, and characterize the gray versus white matter distribution of [11 C]-PBR28 uptake in a larger cohort of patients with ALS and PLS. METHODS: Eighty-five participants including 53 with ALS, 11 with PLS, and 21 healthy controls underwent integrated [11 C]-PBR28 PET-magnetic resonance brain imaging. Patients were clinically assessed using the Upper Motor Neuron Burden (UMNB) and the Amyotrophic Lateral Sclerosis Functional Rating Scale-Revised (ALSFRS-R). [11 C]-PBR28 uptake was quantified as standardized uptake value ratio (SUVR) and compared between groups. Cortical thickness and fractional anisotropy were compared between groups and correlated with SUVR and the clinical data. [11 C]-PBR28 uptake and ALSFRS-R were compared longitudinally over 6 months in 10 ALS individuals. RESULTS: Whole brain voxelwise, surface-based, and region of interest analyses revealed increased [11 C]-PBR28 uptake in the precentral and paracentral gyri in ALS, and in the subcortical white matter for the same regions in PLS, compared to controls. The increase in [11 C]-PBR28 uptake colocalized and correlated with cortical thinning, reduced fractional anisotropy, and increased mean diffusivity, and correlated with higher UMNB score. No significant changes were detected in [11 C]-PBR28 uptake over 6 months despite clinical progression. INTERPRETATION: Glial activation measured by in vivo [11 C]-PBR28 PET is increased in pathologically relevant regions in people with ALS and correlates with clinical measures. Ann Neurol 2018;83:1186-1197.


Assuntos
Esclerose Lateral Amiotrófica/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Esclerose Lateral Amiotrófica/genética , Encéfalo/efeitos dos fármacos , Mapeamento Encefálico , Estudos de Coortes , Correlação de Dados , Estudos Transversais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Pirimidinas/farmacocinética , Receptores de GABA/genética , Índice de Gravidade de Doença
3.
J Magn Reson Imaging ; 48(5): 1288-1296, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29517819

RESUMO

BACKGROUND: Subject motion in positron emission tomography (PET) studies leads to image blurring and artifacts; simultaneously acquired magnetic resonance imaging (MRI) data provides a means for motion correction (MC) in integrated PET/MRI scanners. PURPOSE: To assess the effect of realistic head motion and MR-based MC on static [18 F]-fluorodeoxyglucose (FDG) PET images in dementia patients. STUDY TYPE: Observational study. POPULATION: Thirty dementia subjects were recruited. FIELD STRENGTH/SEQUENCE: 3T hybrid PET/MR scanner where EPI-based and T1 -weighted sequences were acquired simultaneously with the PET data. ASSESSMENT: Head motion parameters estimated from high temporal resolution MR volumes were used for PET MC. The MR-based MC method was compared to PET frame-based MC methods in which motion parameters were estimated by coregistering 5-minute frames before and after accounting for the attenuation-emission mismatch. The relative changes in standardized uptake value ratios (SUVRs) between the PET volumes processed with the various MC methods, without MC, and the PET volumes with simulated motion were compared in relevant brain regions. STATISTICAL TESTS: The absolute value of the regional SUVR relative change was assessed with pairwise paired t-tests testing at the P = 0.05 level, comparing the values obtained through different MR-based MC processing methods as well as across different motion groups. The intraregion voxelwise variability of regional SUVRs obtained through different MR-based MC processing methods was also assessed with pairwise paired t-tests testing at the P = 0.05 level. RESULTS: MC had a greater impact on PET data quantification in subjects with larger amplitude motion (higher than 18% in the medial orbitofrontal cortex) and greater changes were generally observed for the MR-based MC method compared to the frame-based methods. Furthermore, a mean relative change of ∼4% was observed after MC even at the group level, suggesting the importance of routinely applying this correction. The intraregion voxelwise variability of regional SUVRs was also decreased using MR-based MC. All comparisons were significant at the P = 0.05 level. DATA CONCLUSION: Incorporating temporally correlated MR data to account for intraframe motion has a positive impact on the FDG PET image quality and data quantification in dementia patients. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1288-1296.


Assuntos
Encéfalo/diagnóstico por imagem , Demência/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Feminino , Fluordesoxiglucose F18/química , Movimentos da Cabeça , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Distribuição Normal
4.
Eur J Nucl Med Mol Imaging ; 44(3): 398-407, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27573639

RESUMO

PURPOSE: To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners. METHODS: Continuous-valued linear attenuation coefficient maps ("µ-maps") were generated by combining atlases that provided the prior probability of voxel positions belonging to a certain tissue class (air, soft tissue, or bone) and an MR intensity-based likelihood classifier to produce posterior probability maps of tissue classes. These probabilities were used as weights to generate the µ-maps. The accuracy of this probabilistic atlas-based continuous-valued µ-map ("PAC-map") generation method was assessed by calculating the voxel-wise absolute relative change (RC) between the MR-based and scaled CT-based attenuation-corrected PET images. To assess reproducibility, we performed pair-wise comparisons of the RC values obtained from the PET images reconstructed using the µ-maps generated from the data acquired at three time points. RESULTS: The proposed method produced continuous-valued µ-maps that qualitatively reflected the variable anatomy in patients with brain tumor and agreed well with the scaled CT-based µ-maps. The absolute RC comparing the resulting PET volumes was 1.76 ± 2.33 %, quantitatively demonstrating that the method is accurate. Additionally, we also showed that the method is highly reproducible, the mean RC value for the PET images reconstructed using the µ-maps obtained at the three visits being 0.65 ± 0.95 %. CONCLUSION: Accurate and highly reproducible continuous-valued head µ-maps can be generated from MR data using a probabilistic atlas-based approach.


Assuntos
Algoritmos , Cabeça/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Imagem Multimodal/normas , Tomografia por Emissão de Pósitrons/normas , Confiabilidade dos Dados , Cabeça/anatomia & histologia , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/instrumentação , Imagem Multimodal/métodos , Fótons , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos
7.
Brain ; 138(Pt 3): 604-15, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25582579

RESUMO

Although substantial evidence has established that microglia and astrocytes play a key role in the establishment and maintenance of persistent pain in animal models, the role of glial cells in human pain disorders remains unknown. Here, using the novel technology of integrated positron emission tomography-magnetic resonance imaging and the recently developed radioligand (11)C-PBR28, we show increased brain levels of the translocator protein (TSPO), a marker of glial activation, in patients with chronic low back pain. As the Ala147Thr polymorphism in the TSPO gene affects binding affinity for (11)C-PBR28, nine patient-control pairs were identified from a larger sample of subjects screened and genotyped, and compared in a matched-pairs design, in which each patient was matched to a TSPO polymorphism-, age- and sex-matched control subject (seven Ala/Ala and two Ala/Thr, five males and four females in each group; median age difference: 1 year; age range: 29-63 for patients and 28-65 for controls). Standardized uptake values normalized to whole brain were significantly higher in patients than controls in multiple brain regions, including thalamus and the putative somatosensory representations of the lumbar spine and leg. The thalamic levels of TSPO were negatively correlated with clinical pain and circulating levels of the proinflammatory citokine interleukin-6, suggesting that TSPO expression exerts pain-protective/anti-inflammatory effects in humans, as predicted by animal studies. Given the putative role of activated glia in the establishment and or maintenance of persistent pain, the present findings offer clinical implications that may serve to guide future studies of the pathophysiology and management of a variety of persistent pain conditions.


Assuntos
Encéfalo/patologia , Dor Crônica/patologia , Neuroglia/patologia , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Estudos de Casos e Controles , Dor Crônica/diagnóstico por imagem , Dor Crônica/genética , Feminino , Genótipo , Humanos , Interleucina-6/sangue , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neuroglia/diagnóstico por imagem , Polimorfismo de Nucleotídeo Único/genética , Tomografia por Emissão de Pósitrons , Pirimidinas , Receptores de GABA/genética , Receptores de GABA/metabolismo , Estatística como Assunto
8.
Magn Reson Med ; 73(6): 2363-75, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25046699

RESUMO

PURPOSE: Simultaneous acquisition of MR and positron emission tomography (PET) images requires the placement of the MR detection coil inside the PET detector ring where it absorbs and scatters photons. This constraint is the principal barrier to achieving optimum sensitivity on each modality. Here, we present a 31-channel PET-compatible brain array coil with reduced attenuation but improved MR sensitivity. METHODS: A series of component tests were performed to identify tradeoffs between PET and MR performance. Aspects studied include the remote positioning of preamplifiers, coax size, coil trace size/material, and plastic housing. We then maximized PET performance at minimal cost to MR sensitivity. The coil was evaluated for MR performance (signal to noise ratio [SNR], g-factor) and PET attenuation. RESULTS: The coil design showed an improvement in attenuation by 190% (average) compared with conventional 32-channel arrays, and no loss in MR SNR. Moreover, the 31-channel coil displayed an SNR improvement of 230% (cortical region of interest) compared with a PET-optimized 8-channel array with similar attenuation properties. Implementing attenuation correction of the 31-channel array successfully removed PET artifacts, which were comparable to those of the 8-channel array. CONCLUSION: The design of the 31-channel PET-compatible coil enables higher sensitivity for PET/MR imaging, paving the way for novel applications in this hybrid-imaging domain.


Assuntos
Mapeamento Encefálico/métodos , Imagem Multimodal/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética/instrumentação , Sensibilidade e Especificidade
9.
Neuroimage ; 102 Pt 2: 275-82, 2014 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-25107855

RESUMO

MRI and PET provide complementary information for studying brain function. While the potential use of simultaneous MRI/PET for clinical diagnostic and disease staging has been demonstrated recently; the biological relevance of concurrent functional MRI-PET brain imaging to dissect neurochemically distinct components of the blood oxygenation level dependent (BOLD) fMRI signal has not yet been shown. We obtained sixteen fMRI-PET data sets from eight healthy volunteers. Each subject participated in randomized order in a pain scan and a control (nonpainful pressure) scan on the same day. Dynamic PET data were acquired with an opioid radioligand, [(11)C]diprenorphine, to detect endogenous opioid releases in response to pain. BOLD fMRI data were collected at the same time to capture hemodynamic responses. In this simultaneous human fMRI-PET imaging study, we show co-localized responses in thalamus and striatum related to pain processing, while modality specific brain networks were also found. Co-localized fMRI and PET signal changes in the thalamus were positively correlated suggesting that pain-induced changes in opioid neurotransmission contribute a significant component of the fMRI signal change in this region. Simultaneous fMRI-PET provides unique opportunities allowing us to relate specific neurochemical events to functional hemodynamic activation and to investigate the impacts of neurotransmission on neurovascular coupling of the human brain in vivo.


Assuntos
Corpo Estriado/fisiopatologia , Imageamento por Ressonância Magnética , Dor/fisiopatologia , Tomografia por Emissão de Pósitrons , Tálamo/fisiopatologia , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Mapeamento Encefálico , Corpo Estriado/diagnóstico por imagem , Diprenorfina , Feminino , Humanos , Masculino , Antagonistas de Entorpecentes , Dor/diagnóstico por imagem , Receptores Opioides/metabolismo , Tálamo/diagnóstico por imagem , Adulto Jovem
10.
Neuroimage ; 100: 192-9, 2014 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24936683

RESUMO

Glucose is the principal source of energy for the brain and yet the dynamic response of glucose utilization to changes in brain activity is still not fully understood. Positron emission tomography (PET) allows quantitative measurement of glucose metabolism using 2-[(18)F]-fluorodeoxyglucose (FDG). However, FDG PET in its current form provides an integral (or average) of glucose consumption over tens of minutes and lacks the temporal information to capture physiological alterations associated with changes in brain activity induced by tasks or drug challenges. Traditionally, changes in glucose utilization are inferred by comparing two separate scans, which significantly limits the utility of the method. We report a novel method to track changes in FDG metabolism dynamically, with higher temporal resolution than exists to date and within a single session. Using a constant infusion of FDG, we demonstrate that our technique (termed fPET-FDG) can be used in an analysis pipeline similar to fMRI to define within-session differential metabolic responses. We use visual stimulation to demonstrate the feasibility of this method. This new method has a great potential to be used in research protocols and clinical settings since fPET-FDG imaging can be performed with most PET scanners and data acquisition and analysis are straightforward. fPET-FDG is a highly complementary technique to MRI and provides a rich new way to observe functional changes in brain metabolism.


Assuntos
Glicemia/metabolismo , Encéfalo/fisiologia , Neuroimagem Funcional/métodos , Tomografia por Emissão de Pósitrons/métodos , Percepção Visual/fisiologia , Adulto , Animais , Encéfalo/metabolismo , Estudos de Viabilidade , Feminino , Fluordesoxiglucose F18/metabolismo , Humanos , Hipercapnia/diagnóstico , Imageamento por Ressonância Magnética , Imagem Multimodal , Papio
11.
Mol Pharm ; 10(3): 1100-10, 2013 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-23327109

RESUMO

There is an ongoing effort to develop better methods for noninvasive detection and characterization of thrombi. Here we describe the synthesis and evaluation of three new fibrin-targeted positron emission tomography (PET) probes (FBP1, FBP2, FBP3). Three fibrin-specific peptides were conjugated as 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-monoamides at the C- and N-termini and chelated with (64)CuCl2. Probes were prepared with a specific activity ranging from 10 to 130 µCi/nmol. Both the peptides and the probes exhibited nanomolar dissociation constants (Kd) for the soluble fibrin fragment DD(E), although the Cu-DOTA derivatization resulted in a 2-3 fold loss in affinity relative to the parent peptide. Biodistribution and imaging studies were performed in a rat model of carotid artery thrombosis. For FBP1 and FBP2 at 120 min post injection, the vessel containing the thrombus showed the highest concentration of radioactivity after the excretory organs, that is, the liver and kidneys. This was confirmed ex vivo by autoradiography, which showed >4-fold activity in the thrombus-containing artery compared to the contralateral artery. FBP3 showed much lower thrombus uptake, and the difference was traced to greater metabolism of this probe. Hybrid MR-PET imaging with FBP1 or FBP2 confirmed that these probes were effective for the detection of an arterial thrombus in this rat model. A thrombus was visible on PET images as a region of high activity that corresponded to a region of arterial occlusion identified by simultaneous MR angiography. FBP1 and FBP2 represent promising new probes for the molecular imaging of thrombi.


Assuntos
Fibrina/química , Tomografia por Emissão de Pósitrons/métodos , Trombose/diagnóstico , Animais , Cromatografia Líquida de Alta Pressão , Imageamento por Ressonância Magnética , Masculino , Ratos , Ratos Wistar
12.
J Am Chem Soc ; 134(26): 10799-802, 2012 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-22698259

RESUMO

Here we report a generalizable solid/solution-phase strategy for the synthesis of discrete bimodal fibrin-targeted imaging probes. A fibrin-specific peptide was conjugated with two distinct imaging reporters at the C- and N-termini. In vitro studies demonstrated retention of fibrin affinity and specificity. Imaging studies showed that these probes could detect fibrin over a wide range of probe concentrations by optical, magnetic resonance, and positron emission tomography imaging.


Assuntos
Trombose/diagnóstico , Fibrina/análogos & derivados , Fluoresceína-5-Isotiocianato/química , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Peptídeos , Tomografia por Emissão de Pósitrons/métodos
13.
J Cereb Blood Flow Metab ; 42(7): 1309-1321, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35118904

RESUMO

Compartmental modeling analysis of 11C-raclopride (RAC) PET data can be used to measure the dopaminergic response to intra-scan behavioral tasks. Bias in estimates of binding potential (BPND) and its dynamic changes (ΔBPND) can arise both when head motion is present and when the compartmental model used for parameter estimation deviates from the underlying biology. The purpose of this study was to characterize the effects of motion and model bias within the context of a behavioral task challenge, examining the impacts of different mitigation strategies. Seventy healthy adults were administered bolus plus constant infusion RAC during a simultaneous PET/magnetic resonance (MR) scan with a reward task experiment. BPND and ΔBPND were estimated using an extension of the Multilinear Reference Tissue Model (E-MRTM2) and a new method (DE-MRTM2) was proposed to selectively discount the contribution of the initial uptake period. Motion was effectively corrected with a standard frame-based approach, which performed equivalently to a more complex reconstruction-based approach. DE-MRTM2 produced estimates of ΔBPND in putamen and nucleus accumbens that were significantly different from those estimated from E-MRTM2, while also decoupling ΔBPND values from first-pass k2' estimation and removing skew in the spatial bias distribution of parametric ΔBPND estimates within the striatum.


Assuntos
Dopamina , Tomografia por Emissão de Pósitrons , Adulto , Viés , Corpo Estriado/diagnóstico por imagem , Corpo Estriado/metabolismo , Dopamina/metabolismo , Humanos , Tomografia por Emissão de Pósitrons/métodos , Racloprida/metabolismo
14.
J Am Coll Radiol ; 18(7): 1027-1037, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33915120

RESUMO

PURPOSE: Coronavirus disease 2019 and the publicly documented deaths of countless Black individuals have highlighted the need to confront systemic racism, address racial/ethnic disparities, and improve diversity and inclusion in radiology. Several radiology departments have begun to create diversity, equity, and inclusion (DEI) committees to systematically address DEI issues in radiology. However, there are few articles that provide departments with guidance on how to create DEI committees to comprehensively address DEI issues in radiology. The purpose of this review is to provide readers with a framework and practical tips for creating a comprehensive, institutionally aligned radiology DEI committee. METHODS: The authors describe key components of the strategic planning process and lessons learned in the creation of a radiology DEI committee, on the basis of the experience of an integrated, academic northeastern radiology department. RESULTS: A hospital-based strategic planning process defining the DEI vision, mission, goals, and strategies was used to inform the formation of the radiology department DEI committee. The radiology department performed gap analyses by conducting internal and external research. Strengths, weaknesses, opportunities, and threats analyses were performed on the basis of consultations with institutional and other departmental DEI leaders as well as DEI leaders from other academic medical centers. This framework served as the basis for the creation of the radiology departmental DEI committee, including a steering committee and four task forces (education, research, patient experience, and workforce development), each charged with addressing specific institutional goals and strategies. CONCLUSIONS: This review provides academic radiology departments with a blueprint to create a comprehensive, institutionally aligned radiology DEI committee.


Assuntos
COVID-19 , Serviço Hospitalar de Radiologia , Radiologia , Centros Médicos Acadêmicos , Humanos , Estudos Multicêntricos como Assunto , SARS-CoV-2
15.
J Am Coll Radiol ; 18(7): 1000-1008, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33609456

RESUMO

PURPOSE: Disproportionally high rates of coronavirus disease 2019 (COVID-19) have been noted among communities with limited English proficiency, resulting in an unmet need for improved multilingual care and interpreter services. To enhance multilingual care, the authors created a freely available web application, RadTranslate, that provides multilingual radiology examination instructions. The purpose of this study was to evaluate the implementation of this intervention in radiology. METHODS: The device-agnostic web application leverages artificial intelligence text-to-speech technology to provide standardized, human-like spoken examination instructions in the patient's preferred language. Standardized phrases were collected from a consensus group consisting of technologists, radiologists, and ancillary staff members. RadTranslate was piloted in Spanish for chest radiography performed at a COVID-19 triage outpatient center that served a predominantly Spanish-speaking Latino community. Implementation included a tablet displaying the application in the chest radiography room. Imaging appointment duration was measured and compared between pre- and postimplementation groups. RESULTS: In the 63-day test period after launch, there were 1,267 application uses, with technologists voluntarily switching exclusively to RadTranslate for Spanish-speaking patients. The most used phrases were a general explanation of the examination (30% of total), followed by instructions to disrobe and remove any jewelry (12%). There was no significant difference in imaging appointment duration (11 ± 7 and 12 ± 3 min for standard of care versus RadTranslate, respectively), but variability was significantly lower when RadTranslate was used (P = .003). CONCLUSIONS: Artificial intelligence-aided multilingual audio instructions were successfully integrated into imaging workflows, reducing strain on medical interpreters and variance in throughput and resulting in more reliable average examination length.


Assuntos
COVID-19 , Proficiência Limitada em Inglês , Inteligência Artificial , Humanos , Pandemias , SARS-CoV-2
16.
Mol Imaging Biol ; 23(5): 625-638, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33903986

RESUMO

This paper summarizes the 2020 Diversity in Radiology and Molecular Imaging: What We Need to Know Conference, a three-day virtual conference held September 9-11, 2020. The World Molecular Imaging Society (WMIS) and Stanford University jointly organized this event to provide a forum for WMIS members and affiliates worldwide to openly discuss issues pertaining to diversity in science, technology, engineering, and mathematics (STEM). The participants discussed three main conference themes, "racial diversity in STEM," "women in STEM," and "global health," which were discussed through seven plenary lectures, twelve scientific presentations, and nine roundtable discussions, respectively. Breakout sessions were designed to flip the classroom and seek input from attendees on important topics such as increasing the representation of underrepresented minority (URM) members and women in STEM, generating pipeline programs in the fields of molecular imaging, supporting existing URM and women members in their career pursuits, developing mechanisms to effectively address microaggressions, providing leadership opportunities for URM and women STEM members, improving global health research, and developing strategies to advance culturally competent healthcare.


Assuntos
Diversidade Cultural , Liderança , Radiologia/organização & administração , Tecnologia Radiológica/organização & administração , Engenharia , Humanos , Grupos Minoritários , Imagem Molecular , Mulheres
17.
Neuroimage Clin ; 17: 680-690, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29255671

RESUMO

Pain interventions with no active ingredient, placebo, are sometimes effective in treating chronic pain conditions. Prior studies on the neurobiological underpinnings of placebo analgesia indicate endogenous opioid release and changes in brain responses and functional connectivity during pain anticipation and pain experience in healthy subjects. Here, we investigated placebo analgesia in healthy subjects and in interictal migraine patients (n = 9) and matched healthy controls (n = 9) using 11C-diprenoprhine Positron Emission Tomography (PET) and simultaneous functional Magnetic Resonance Imaging (fMRI). Intravenous saline injections (the placebo) led to lower pain ratings, but we did not find evidence for an altered placebo response in interictal migraine subjects as compared to healthy subjects.


Assuntos
Analgesia , Encéfalo/fisiopatologia , Transtornos de Enxaqueca/fisiopatologia , Efeito Placebo , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Feminino , Humanos , Injeções Intravenosas , Imageamento por Ressonância Magnética , Masculino , Transtornos de Enxaqueca/diagnóstico por imagem , Transtornos de Enxaqueca/metabolismo , Imagem Multimodal , Medição da Dor , Limiar da Dor , Placebos/administração & dosagem , Tomografia por Emissão de Pósitrons , Receptores Opioides/metabolismo , Cloreto de Sódio/administração & dosagem , Adulto Jovem
19.
J Nucl Med ; 2018 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-29934405

RESUMO

A main advantage of PET is that it provides quantitative measures of the radiotracer concentration, but its accuracy is confounded by several factors, including attenuation, subject motion, and limited spatial resolution. Using the information from one simultaneously acquired morphological MR sequence with embedded navigators, we propose an efficient method called MR-assisted PET data optimization (MaPET) to perform attenuation correction (AC), motion correction, and anatomy-aided reconstruction. Methods: For attenuation correction, voxel-wise linear attenuation coefficient maps were generated using an SPM8-based approach method on the MR volume. The embedded navigators were used to derive head motion estimates for event-based PET motion correction. The anatomy provided by the MR volume was incorporated into the PET image reconstruction using a kernel-based method. Region-based analyses were carried out to assess the quality of images generated through various stages of PET data optimization. Results: The optimized PET images reconstructed with MaPET was superior in image quality compared to images reconstructed using only attenuation correction, with high SNR and low coefficient of variation (5.08 and 0.229 in a composite cortical region compared to 3.12 and 0.570). The optimized images were also shown using the Cohen's d metric to achieve a greater effect size in distinguishing cortical regions with hypometabolism from regions of preserved metabolism in each individual for different diagnosis groups. Conclusion: We have shown the spatiotemporally correlated data acquired using a single MR sequence can be used for PET attenuation, motion and partial volume effects corrections and the MaPET method may enable more accurate assessment of pathological changes in dementia and other brain disorders.

20.
Neuroimage Clin ; 17: 347-353, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29159046

RESUMO

BACKGROUND: Glia activation is thought to contribute to neuronal damage in several neurodegenerative diseases based on preclinical and human post-mortem studies, but its role in primary lateral sclerosis (PLS) is unknown. OBJECTIVES: To localize and measure glia activation in people with PLS compared to healthy controls (HC). METHODS: Ten participants with PLS and ten age-matched HCs underwent simultaneous magnetic resonance (MR) and proton emission tomography (PET). The radiotracer [11C]-PBR28 was used to obtain PET-based measures of 18 kDa translocator protein (TSPO) expression, a marker of activated glial cells. MR techniques included a structural sequence to measure cortical thickness and diffusion tensor imaging (DTI) to assess white matter integrity. RESULTS: PET data showed increased [11C]-PBR28 uptake in anatomically-relevant motor regions which co-localized with areas of regional gray matter atrophy and decreased subcortical fractional anisotropy. CONCLUSIONS: This study supports a link between glia activation and neuronal degeneration in PLS, and suggests that these disease mechanisms can be measured in vivo in PLS. Future studies are needed to determine the longitudinal changes of these imaging measures and to clarify if MR-PET with [11C]-PBR28 can be used as a biomarker for drug development in the context of clinical trials for PLS.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Encéfalo/patologia , Doença dos Neurônios Motores/diagnóstico por imagem , Doença dos Neurônios Motores/patologia , Neuroglia/metabolismo , Adulto , Idoso , Radioisótopos de Carbono , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Receptores de GABA/metabolismo , Substância Branca/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA