Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Anal Biochem ; 382(1): 9-15, 2008 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-18687306

RESUMO

All donor blood samples must be tested pretransfusion to determine the donor blood type. Standard testing protocols require that assays be performed for important bloodborne pathogens such as hepatitis C, syphilis, hepatitis B, and human immunodeficiency virus. We have demonstrated proof of the concept that a protein microarray can type whole blood and detect antibody to significant pathogens simultaneously from the same donor blood sample. The data collected demonstrate the ability of the array to accurately type blood samples while also detecting the presence of antibodies against both human immunodeficiency virus and hepatitis C virus. In conclusion, we have successfully developed a platform capable of typing human whole blood samples, while at the same time testing for the presence of antibodies specific for human immunodeficiency virus/hepatitis C virus. The major benefits of this system are its amenability to expansion with additional assays, for example, rhesus typing and syphilis and/or hepatitis B virus detection, and also the adaptability of the assay to higher-throughput analysis, currently 16 individual samples per slide, but readily expandable to a 96-well format.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/métodos , Infecções por HIV/diagnóstico , Infecções por HIV/imunologia , Hepatite C/diagnóstico , Hepatite C/imunologia , Análise Serial de Proteínas , Testes Sorológicos/métodos , Animais , Bovinos , Reações Cruzadas , Anticorpos Anti-HIV/imunologia , Antígenos HIV/imunologia , Infecções por HIV/genética , Anticorpos Anti-Hepatite/imunologia , Hepatite C/genética , Antígenos da Hepatite C/imunologia , Humanos , Fenótipo , Fatores de Tempo
2.
J Immunoassay Immunochem ; 29(2): 197-209, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18360814

RESUMO

All donor blood samples must be tested pre-transfusion to determine the blood type of donor erythrocytes, based on the ABO typing system. Current methods of testing are well characterised, but require a number of processing steps prior to analysis. In addition, standard testing protocols require additional assays such as hepatitis C and HIV testing be performed separately. We describe and evaluate a protein microarray platform for ABO blood typing that has the potential to be a simple reliable high throughput method, with the added capability for the integration of other important pre-transfusion tests. Sixty seven donor blood samples were incubated on microarrays printed with multiple spotted replicates of blood type antigen specific antibodies. We utilised a hold-out cross validation approach, combined with Receiver Operator Characteristic (ROC) curves to define thresholds within which a sample could be defined as being of a particular blood type. The threshold values from the ROC curve analysis demonstrated an excellent ability to accurately separate samples based on ABO blood type. The results obtained when the thresholds from the training sets were applied to test sets were also very encouraging, with misclassified samples being present in only 2 of the training sets and a mean classification error of 4.28%. When the mean thresholds were applied to the 67 donor samples, 95.5% were correctly blood typed (64 of 67 samples). We have demonstrated the ability of our protein microarray platform to successfully and accurately type human whole blood samples. We believe that this flexible platform provides a strong basis for an integrated approach for combined blood typing and pathogen testing in human whole blood.


Assuntos
Sistema ABO de Grupos Sanguíneos/sangue , Tipagem e Reações Cruzadas Sanguíneas/métodos , Infecções por HIV/sangue , Hepatite C/sangue , Análise Serial de Proteínas , Humanos , Análise Serial de Proteínas/métodos , Análise Serial de Proteínas/normas , Curva ROC
3.
Front Immunol ; 9: 2866, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30619257

RESUMO

Passive transfer studies in humans clearly demonstrated the protective role of IgG antibodies against malaria. Identifying the precise parasite antigens that mediate immunity is essential for vaccine design, but has proved difficult. Completion of the Plasmodium falciparum genome revealed thousands of potential vaccine candidates, but a significant bottleneck remains in their validation and prioritization for further evaluation in clinical trials. Focusing initially on the Plasmodium falciparum merozoite proteome, we used peer-reviewed publications, multiple proteomic and bioinformatic approaches, to select and prioritize potential immune targets. We expressed 109 P. falciparum recombinant proteins, the majority of which were obtained using a mammalian expression system that has been shown to produce biologically functional extracellular proteins, and used them to create KILchip v1.0: a novel protein microarray to facilitate high-throughput multiplexed antibody detection from individual samples. The microarray assay was highly specific; antibodies against P. falciparum proteins were detected exclusively in sera from malaria-exposed but not malaria-naïve individuals. The intensity of antibody reactivity varied as expected from strong to weak across well-studied antigens such as AMA1 and RH5 (Kruskal-Wallis H test for trend: p < 0.0001). The inter-assay and intra-assay variability was minimal, with reproducible results obtained in re-assays using the same chip over a duration of 3 months. Antibodies quantified using the multiplexed format in KILchip v1.0 were highly correlated with those measured in the gold-standard monoplex ELISA [median (range) Spearman's R of 0.84 (0.65-0.95)]. KILchip v1.0 is a robust, scalable and adaptable protein microarray that has broad applicability to studies of naturally acquired immunity against malaria by providing a standardized tool for the detection of antibody correlates of protection. It will facilitate rapid high-throughput validation and prioritization of potential Plasmodium falciparum merozoite-stage antigens paving the way for urgently needed clinical trials for the next generation of malaria vaccines.


Assuntos
Malária Falciparum/imunologia , Merozoítos/imunologia , Plasmodium falciparum/imunologia , Análise Serial de Proteínas/métodos , Proteoma/imunologia , Proteômica/métodos , Prioridades em Saúde , Vacinas Antimaláricas/imunologia , Malária Falciparum/microbiologia , Merozoítos/metabolismo , Plasmodium falciparum/metabolismo , Plasmodium falciparum/fisiologia , Proteoma/metabolismo , Proteínas de Protozoários/imunologia , Proteínas de Protozoários/metabolismo , Pesquisa
4.
Methods Mol Biol ; 785: 345-61, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21901611

RESUMO

A significant proportion of protein microarray researchers would like the arrays they develop to become widely used research, screening, validation or diagnostic devices. For this to be achievable the arrays must be compatible with high-throughput techniques that allow manufacturing scale production. In order to simplify the transition from laboratory bench to market, Arrayjet have developed a range of inkjet microarray printers, which, at one end of the scale, are suitable for R&D and, at the other end, are capable of true high-throughput array output. To maintain scalability, all Arrayjet microarray printers utilise identical core technology comprising a JetSpyder™ liquid handling adaptor, which enables automated loading of an industry standard inkjet printhead compatible with non-contact on-the-fly printing. This chapter contains a detailed explanation of Arrayjet technology followed by a historical look at the development of inkjet technologies for protein microarray production. The method described subsequently is a simple example of an antibody array printed onto nitrocellulose-coated slides with specific detection with fluorescently labelled IgG. The method is linked to a notes section with advice on best practice and sources of useful information for protein microarray production using inkjet technology.


Assuntos
Ensaios de Triagem em Larga Escala/instrumentação , Impressão/instrumentação , Análise Serial de Proteínas/instrumentação , Colódio , Fluorescência , Imunoglobulina G
5.
Anal Chem ; 78(6): 1930-8, 2006 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-16536430

RESUMO

Microarrays promise great advances in areas of diagnostic testing where there is a need to perform multiple assays in parallel. In the short term, protein microarrays have a greater potential to impact diagnostics than DNA arrays due to their potential for direct sample measurements. Here, we report an antibody microarray technique for selectively recognizing glycan and peptide motifs on the surface of red blood cells. We present results demonstrating the optimization and efficacy of the microarray approach as a highly sensitive and specific microscale multiplex assay for blood typing. We also show that our microarray can be used to screen red blood cell surface antigens using whole blood in a label-free detection mode. Finally, our results indicate this method has potential for broader applications in biochip medicine.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/instrumentação , Tipagem e Reações Cruzadas Sanguíneas/métodos , Eritrócitos/química , Análise em Microsséries/instrumentação , Análise em Microsséries/métodos , Reações Antígeno-Anticorpo , Linhagem Celular , Humanos , Peptídeos/análise , Fenótipo , Polissacarídeos/análise , Sensibilidade e Especificidade , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA