RESUMO
BACKGROUND: A conditionally replication-defective human cytomegalovirus (CMV) vaccine (V160) derived from AD169 and genetically engineered to express CMV pentameric complex (gH/gL/pUL128/pUL130/pUL131) was developed and evaluated for phase 1 vaccine safety and immunogenicity in CMV-seronegative and CMV-seropositive adults. METHODS: Subjects received 3 doses of V160 or placebo on day 1, month 1, and month 6. Four vaccine dose levels, formulated with or without aluminum phosphate adjuvant, were evaluated. Injection-site and systemic adverse events (AEs) and vaccine viral shedding were monitored. CMV-specific cellular and humoral responses were measured by interferon-gamma ELISPOT and virus neutralization assay up to 12 months after last dose. RESULTS: V160 was generally well-tolerated, with no serious AEs observed. Transient, mild-to-moderate injection-site and systemic AEs were reported more frequently in vaccinated subjects than placebo. Vaccine viral shedding was not detected in any subject, confirming the nonreplicating feature of V160. Robust neutralizing antibody titers were elicited and maintained through 12 months postvaccination. Cellular responses to structural and nonstructural viral proteins were observed, indicating de novo expression of viral genes postvaccination. CONCLUSIONS: V160 displayed an acceptable safety profile. Levels of neutralizing antibodies and T-cell responses in CMV-seronegative subjects were within ranges observed following natural CMV infection. CLINICAL TRIAL REGISTRATION: . NCT01986010.
Assuntos
Infecções por Citomegalovirus/imunologia , Vacinas contra Citomegalovirus/imunologia , Citomegalovirus/imunologia , Replicação Viral/imunologia , Adjuvantes Imunológicos/administração & dosagem , Adolescente , Adulto , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , Método Duplo-Cego , ELISPOT/métodos , Feminino , Humanos , Imunidade Celular/imunologia , Imunidade Humoral/imunologia , Imunização/métodos , Masculino , Pessoa de Meia-Idade , Linfócitos T/imunologia , Vacinação/métodos , Eliminação de Partículas Virais/imunologia , Adulto JovemAssuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucagon/efeitos adversos , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , TemperaturaRESUMO
BACKGROUND: Accuracy of a seventh-generation "G7" continuous glucose monitoring (CGM) system was evaluated in children and adolescents with type 1 diabetes (T1D). METHODS: Sensors were worn on the upper arm and abdomen. The CGM data were available from 127 of 132 participants, ages 7 to 17 years, across 10.5 days of use, various glucose concentration ranges, and various rates of glucose change for comparisons with temporally matched venous blood glucose measurements (YSI). Data were also available from 28 of 32 participants, ages 2 to 6 years, for whom capillary (fingerstick) blood provided comparator glucose values. Accuracy metrics included the mean absolute relative difference (MARD) between CGM and comparator glucose pairs, the proportion of CGM values within 15 mg/dL or 15% of comparator values <100 or ≥100 mg/dL, respectively, and the analogous %20/20 and %30/30 agreement rates. RESULTS: For participants aged 7 to 17, a total of 15 437 matched pairs were obtained from 122 arm-placed and 118 abdomen-placed sensors. For arm-placed sensors, the overall MARD was 8.1% and overall %15/15, %20/20, and %30/30 agreement rates were 88.8%, 95.3%, and 98.7%, respectively. For abdomen-placed sensors, the overall MARD was 9.0% and overall %15/15, %20/20, and %30/30 agreement rates were 86.0%, 92.9%, and 97.7%, respectively. Good accuracy was maintained across wear days, glucose ranges, and rates of glucose change. Among those aged 2 to 6, a total of 343 matched pairs provided an overall MARD of 9.3% and an overall %20/20 agreement rate of 91.5%. CONCLUSIONS: The G7 CGM placed on the arm or abdomen was accurate in children and adolescents with T1D. NCT#: NCT04794478.
Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Criança , Humanos , Abdome , Glicemia , Automonitorização da Glicemia , Reprodutibilidade dos TestesRESUMO
Background: Safety and significant improvement in overall glycated hemoglobin (A1C) and percentage of time spent in (TIR), below (TBR), and above (TAR) glucose range were demonstrated in the pivotal trial of adolescents and adults using the MiniMed™ advanced hybrid closed-loop (AHCL) system with the adjunctive, calibration-required Guardian™ Sensor 3. The present study evaluated early outcomes of continued access study (CAS) participants who transitioned from the pivotal trial investigational system to the approved MiniMed™ 780G system with the non-adjunctive, calibration-free Guardian™ 4 Sensor (MM780G+G4S). Study data were presented alongside those of real-world MM780G+G4S users from Europe, the Middle East, and Africa. Methods: The CAS participants (N = 109, aged 7-17 years and N = 67, aged >17 years) used the MM780G+G4S for 3 months and data of real-world MM780G+G4S system users (N = 10,204 aged ≤15 years and N = 26,099 aged >15 years) were uploaded from September 22, 2021 to December 02, 2022. At least 10 days of real-world continuous glucose monitoring (CGM) data were required for analyses. Glycemic metrics, delivered insulin and system use/interactions underwent descriptive analyses. Results: Time in AHCL and CGM use were >90% for all groups. AHCL exits averaged 0.1/day and there were few blood glucose measurements (BGMs) (0.8/day-1.0/day). Adults in both cohorts met most consensus recommendations for glycemic targets. Pediatric groups met recommendations for %TIR and %TBR, although not those for mean glucose variability and %TAR, possibly due to low use of recommended glucose target (100 mg/dL) and active insulin time (2 h) settings (28.4% in the CAS cohort and 9.4% in the real-world cohort). The CAS pediatric and adult A1C were 7.2% ± 0.7% and 6.8% ± 0.7%, respectively, and there were no serious adverse events. Conclusions: Early clinical use of the MM780G+G4S was safe and involved minimal BGMs and AHCL exits. Consistent with real-world pediatric and adult use, outcomes were associated with achievement of recommended glycemic targets. Clinical Trial Registration number: NCT03959423.
Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Criança , Humanos , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Hemoglobinas Glicadas , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de InsulinaRESUMO
Objective: To evaluate safety and effectiveness of MiniMed™ 670G hybrid closed loop (HCL) in comparison with continuous subcutaneous insulin infusion (CSII) therapy for 6 months in persons with type 1 diabetes (T1D). Methods: Adults (aged 18-80 years), adolescents, and children (aged 2-17 years) with T1D who were using CSII therapy were enrolled and randomized (1:1) to 6 months of HCL intervention (n = 151, mean age of 39.9 ± 19.8 years) or CSII without continuous glucose monitoring (n = 151, 35.7 ± 18.4 years). Primary effectiveness endpoints included change in A1C for Group 1 (baseline A1C >8.0%), from baseline to the end of study, and difference in the end of study percentage of time spent below 70 mg/dL (%TBR <70 mg/dL) for Group 2 (baseline A1C ≤8.0%), to show superiority of HCL intervention versus control. Secondary effectiveness endpoints were change in A1C and %TBR <70 mg/dL for Group 2 and Group 1, respectively, to show noninferiority of HCL intervention versus control. Primary safety endpoints were rates of severe hypoglycemia and diabetic ketoacidosis (DKA). Results: Change in A1C and difference in %TBR <70 mg/dL for the overall group were significantly improved, in favor of HCL intervention. In addition, a significant mean (95% confidence interval) change in A1C was observed for both Group 1 (-0.8% [-1.1% to -0.4%], P < 0.0001) and Group 2 (-0.3% [-0.5% to -0.1%], P < 0.0001), in favor of HCL intervention. The same was observed for difference in %TBR <70 mg/dL for Group 1 (-2.2% [-3.6% to -0.9%]) and Group 2 (-4.9% [-6.3% to -3.6%]) (P < 0.0001 for both). There was one DKA event during run-in and six severe hypoglycemic events: two during run-in and four during study (HCL: n = 0 and CSII: n = 4 [6.08 per 100 patient-years]). Conclusions: This RCT demonstrates that the MiniMed 670G HCL safely and significantly improved A1C and %TBR <70 mg/dL compared with CSII control in persons with T1D, irrespective of baseline A1C level.
Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Adulto , Criança , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/tratamento farmacológico , Hemoglobinas Glicadas , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Pré-Escolar , Idoso , Idoso de 80 Anos ou maisRESUMO
BACKGROUND: In this study, we evaluated the analytical performance of the second-generation factory-calibrated FreeStyle Libre Flash Glucose Monitoring (FreeStyle Libre 2) System compared to plasma venous blood glucose reference, Yellow Springs Instrument 2300 (YSI). METHODS: The study enrolled participants aged four and above with type 1 or type 2 diabetes at seven sites in the United States. Adult participants (18+ years) participated in three in-clinic sessions and pediatric participants (4-17 years) participated in up to two in-clinic sessions stratified to provide data for days 1, 2, 3, 7, 8, 9, 12, 13, or 14 of sensor wear. Participants aged 11+ underwent supervised glycemic manipulation during in-clinic sessions to achieve glucose levels across the measurement range of the System. Performance evaluation included accuracy measures such as the proportion of continuous glucose monitoring (CGM) values that were within ±20% or ±20 mg/dL of reference glucose values, and bias measures such as the mean absolute relative difference (MARD) between CGM and reference values. RESULTS: Data from the 144 adults and 129 pediatric participants were analyzed. Percent of sensor results within ±20%/20 mg/dL of YSI reference were 93.2% and 92.1%, and MARD was 9.2% and 9.7% for the adults and pediatric participants, respectively. The System performed well in the hypoglycemic range, with 94.3% of the results for the adult population and 96.1% of the data for pediatric population being within 15 mg/dL of the YSI reference. The time lag was 2.4 ± 4.6 minutes for adults and 2.1 ± 5.0 minutes for pediatrics. CONCLUSIONS: The System demonstrated improved analytical accuracy performance across the dynamic range during the 14-day sensor wear period as compared to the previous-generation device.NCT#: NCT03607448 and NCT03820050.
Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Pediatria , Adulto , Idoso , Algoritmos , Glicemia , Automonitorização da Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glucose , Humanos , Reprodutibilidade dos TestesRESUMO
Background: Use of continuous glucose monitoring (CGM) systems is being rapidly adopted as standard of care for insulin-requiring patients with diabetes. The PROMISE study (NCT03808376) evaluated the accuracy and safety of the next-generation implantable Eversense CGM system for up to 180 days. Methods: This was a prospective multicenter study involving 181 subjects with diabetes at 8 USA sites. All subjects were inserted with a primary sensor. Ninety-six subjects had a second sensor, either an identical sensor or a modified sensor (sacrificial boronic acid [SBA]), inserted in their other arm (53 and 43 subjects, respectively). Accuracy was evaluated by comparing CGM to YSI 2300 glucose analyzer (Yellow Springs Instrument [YSI]) values during 10 clinic visits (day 1-180). Confirmed event detection rates, calibration stability, sensor survival, and serious adverse events (SAEs) were evaluated. Results: For primary sensors, the percent CGM readings within 20%/20% of YSI values was 92.9%; overall mean absolute relative difference (MARD) was 9.1%. The confirmed alert detection rate at 70 mg/dL was 93% and at 180 mg/dL was 99%. The median percentage of time for one calibration per day was 56%. Sixty-five percent of the primary sensors survived to 180 days. For the SBA sensors, the percent CGM readings within 20%/20% of YSI values was 93.9%; overall MARD was 8.5%. The confirmed alert detection rate at 70 mg/dL was 94% and at 180 mg/dL was 99%. The median percentage of time for one calibration per day was 63%. Ninety percent of the SBA sensors survived to 180 days. No device- or insertion/removal procedure-related SAEs were reported. Conclusion: These data show the next-generation Eversense CGM system had sustained accuracy and safety up to 180 days, with an improved calibration scheme and survival, using the primary or SBA sensors.
Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Estudos Prospectivos , Reprodutibilidade dos TestesRESUMO
Background: We evaluated the accuracy and safety of a seventh generation (G7) Dexcom continuous glucose monitor (CGM) during 10.5 days of use in adults with diabetes. Methods: Adults with either type 1 or type 2 diabetes (on intensive insulin therapy or not) participated at 12 investigational sites in the United States. In-clinic visits were conducted on days 1 or 2, 4 or 7, and on the second half of day 10 or the first half of day 11 for frequent comparisons with comparator blood glucose measurements obtained with the YSI 2300 Stat Plus glucose analyzer. Participants wore sensors concurrently on the upper arm and abdomen. Accuracy evaluation included the proportion of CGM values within 15% of comparator glucose levels >100 mg/dL or within 15 mg/dL of comparator levels ≤100 mg/dL (%15/15), along with the %20/20 and %30/30 agreement rates. The mean absolute relative difference (MARD) between temporally matched CGM and comparator values was also calculated. Results: Data from 316 participants (619 sensors, 77,774 matched pairs) were analyzed. For arm- and abdomen-placed sensors, overall MARDs were 8.2% and 9.1%, respectively. Overall %15/15, %20/20, and %30/30 agreement rates were 89.6%, 95.3%, and 98.8% for arm-placed sensors and were 85.5%, 93.2%, and 98.1% for abdomen-placed sensors. Across days of wear, glucose concentration ranges, and rates of change, %20/20 agreement rates varied by no more than 9% from the overall %20/20. No serious adverse events were reported. Conclusions: The G7 CGM provides accurate glucose readings with single-digit MARD with arm or abdomen placement in adults with diabetes. Clinicaltrials.gov: NCT04794478.
Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glucose , Humanos , Reprodutibilidade dos TestesRESUMO
Hyperglucagonemia contributes to hyperglycemia in patients with type 1 diabetes (T1D); however, novel therapeutics that block glucagon action could improve glycemic control. This phase 2 study evaluated the safety and efficacy of volagidemab, an antagonistic monoclonal glucagon receptor (GCGR) antibody, as an adjunct to insulin therapy in adults with T1D. The primary endpoint was change in daily insulin use at week 12. Secondary endpoints included changes in hemoglobin A1c (HbA1c) at week 13, in average daily blood glucose concentration and time within target range as assessed by continuous blood glucose monitoring (CGM) and seven-point glucose profile at week 12, incidence of hypoglycemic events, the proportion of subjects who achieve HbA1c reduction of ≥0.4%, volagidemab drug concentrations and incidence of anti-drug antibodies. Eligible participants (n = 79) were randomized to receive weekly subcutaneous injections of placebo, 35 mg volagidemab or 70 mg volagidemab. Volagidemab produced a reduction in total daily insulin use at week 12 (35 mg volagidemab: -7.59 units (U) (95% confidence interval (CI) -11.79, -3.39; P = 0.040 versus placebo); 70 mg volagidemab: -6.64 U (95% CI -10.99, -2.29; P = 0.084 versus placebo); placebo: -1.27 U (95% CI -5.4, 2.9)) without meeting the prespecified significance level (P < 0.025). At week 13, the placebo-corrected reduction in HbA1c percentage was -0.53 (95% CI -0.89 to -0.17, nominal P = 0.004) in the 35 mg volagidemab group and -0.49 (95% CI -0.85 to -0.12, nominal P = 0.010) in the 70 mg volagidemab group. No increase in hypoglycemia was observed with volagidemab therapy; however, increases in serum transaminases, low-density lipoprotein (LDL)-cholesterol and blood pressure were observed. Although the primary endpoint did not meet the prespecified significance level, we believe that the observed reduction in HbA1c and tolerable safety profile provide a rationale for further randomized studies to define the long-term efficacy and safety of volagidemab in patients with T1D.
Assuntos
Anticorpos Monoclonais Humanizados , Diabetes Mellitus Tipo 1 , Receptores de Glucagon , Adulto , Anticorpos Monoclonais Humanizados/efeitos adversos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Método Duplo-Cego , Glucagon , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/uso terapêutico , Humanos , Insulina/uso terapêutico , Lipoproteínas LDL/uso terapêutico , Receptores de Glucagon/antagonistas & inibidores , Transaminases/uso terapêutico , Resultado do TratamentoRESUMO
INTRODUCTION: To prevent medical sequelae of severe hypoglycemic emergencies, prompt and reliable rescue intervention is critically important. A ready-to-use, liquid stable glucagon, administered subcutaneously by glucagon autoinjector (GAI), Gvoke HypoPen (glucagon injection; Xeris Pharmaceuticals), was evaluated for rescue treatment of severe hypoglycemia. RESEARCH DESIGN AND METHODS: Two phase III, randomized, controlled, blinded, non-inferiority crossover studies were conducted in 161 adults with type 1 diabetes to compare 1 mg doses of GAI versus glucagon emergency kit (GEK) for treating insulin-induced severe hypoglycemia. Efficacy was evaluated as either a return of plasma glucose to >70 mg/dL (3.9 mmol/L) or increase ≥20 mg/dL (1.1 mmol/L) from a baseline glucose of <50 mg/dL (2.9 mmol/L), within 30 min of dosing. RESULTS: For successful plasma glucose recovery within 30 min, treatment with GAI was non-inferior to GEK. Treatment with GAI was non-inferior to GEK for a plasma glucose >70 mg/dL (3.9 mmol/L) or neuroglycopenic symptom relief within 30 min. From administration of glucagon, the mean time to achieve plasma glucose >70 mg/dL (3.9 mmol/L) or increase ≥20 mg/dL (1.1 mmol/L) was 13.8±5.6 min for GAI and 10.0±3.6 min for GEK. This mean time does not account for the significantly shorter (p<0.0001) drug preparation and administration time for GAI (27.3±19.7 s) versus GEK (97.2±45.1 s). The incidence of treatment emergent adverse events was comparable in both groups. CONCLUSIONS: A ready-to-use GAI was non-inferior to GEK, with a similar tolerability profile. GAI is an effective, safe, and well-tolerated rescue treatment for severe hypoglycemia and is a viable alternative to GEK. TRIAL REGISTRATION NUMBERS: NCT02656069 and NCT03439072.
Assuntos
Glucagon , Hipoglicemia , Glicemia , Estudos Cross-Over , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , InsulinaRESUMO
OBJECTIVE: To investigate factors related to glycemic management among members of a professional cycling team with type 1 diabetes over a 7-day Union Cycliste Internationale World Tour stage race. RESEARCH DESIGN AND METHODS: An observational evaluation of possible factors related to glycemic management and performance in six male professional cyclists with type 1 diabetes (HbA1c 6.4 ± 0.6%) during the 2019 Tour of California. RESULTS: In-ride time spent in euglycemia (3.9-10.0 mmol/L glucose) was 63 ± 11%, with a low percentage of time spent in level 1 (3.0-3.9 mmol/L; 0 ± 1% of time) and level 2 (<3.0 mmol/L; 0 ± 0% of time) hypoglycemia over the 7-day race. Riders spent 25 ± 9% of time in level 1 (10.1-13.9 mmol/L) and 11 ± 9% in level 2 (>13.9 mmol/L) hyperglycemia during races. Bolus insulin use was uncommon during races, despite high carbohydrate intake (76 ± 23 g â h-1). Overnight, the riders spent progressively more time in hypoglycemia from day 1 (6 ± 12% in level 1 and 0 ± 0% in level 2) to day 7 (12 ± 12% in level 1 and 2 ± 4% in level 2) (χ2[1] > 4.78, P < 0.05). CONCLUSIONS: Professional cyclists with type 1 diabetes have excellent in-race glycemia, but significant hypoglycemia during recovery overnight, throughout a 7-day stage race.
Assuntos
Atletas , Ciclismo/fisiologia , Glicemia/metabolismo , Diabetes Mellitus Tipo 1/sangue , Controle Glicêmico , Adulto , Automonitorização da Glicemia , California , Comportamento Competitivo , Diabetes Mellitus Tipo 1/tratamento farmacológico , Controle Glicêmico/normas , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Autogestão/métodos , Fatores de TempoRESUMO
INTRODUCTION: This prospective observational study sought to establish the glycemic, physiological and dietary demands of strenuous exercise training as part of a 9-day performance camp in a professional cycling team with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: Sixteen male professional cyclists with T1D on multiple daily injections (age: 27±4 years; duration of T1D: 11±5 years; body mass index: 22±2 kg/m2; glycated hemoglobin: 7%±1% (50±6 mmol/mol); maximum rate of oxygen consumption: 73±4 mL/kg/min) performed road cycle sessions (50%-90% of the anaerobic threshold, duration 1-6 hours) over 9 consecutive days. Glycemic (Dexcom G6), nutrition and physiological data were collected throughout. Glycemic data were stratified into predefined glycemic ranges and mapped alongside exercise physiology and nutritional parameters, as well as split into daytime and night-time phases for comparative analysis. Data were assessed by means of analysis of variance and paired t-tests. A p value of ≤0.05 (two-tailed) was statistically significant. RESULTS: Higher levels of antecedent hypoglycemia in the nocturnal hours were associated with greater time spent in next-day hypoglycemia overall (p=0.003) and during exercise (p=0.019). Occurrence of nocturnal hypoglycemia was associated with over three times the risk of next-day hypoglycemia (p<0.001) and a twofold risk of low glucose during cycling (p<0.001). Moreover, there was trend for a greater amount of time spent in mild hypoglycemia during the night compared with daytime hours (p=0.080). CONCLUSION: The higher prevalence of nocturnal hypoglycemia was associated with an increased risk of next-day hypoglycemia, which extended to cycle training sessions. These data highlight the potential need for additional prebed carbohydrates and/or insulin dose reduction strategies around exercise training in professional cyclists with T1D. TRIAL REGISTRATION NUMBER: DRKS00019923.
Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Glicemia , Diabetes Mellitus Tipo 1/epidemiologia , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/epidemiologia , Hipoglicemiantes , Masculino , Adulto JovemRESUMO
Background: A prior study (PRECISE II) demonstrated that an implantable continuous glucose monitoring (CGM) system (Eversense® CGM System) provided accurate glucose readings through the 90-day sensor life with a favorable safety profile in participants with type 1 or type 2 diabetes (T1D, T2D). This study was performed to further characterize the accuracy of the system. Methods: PRECISION was a prospective multicenter study that evaluated the accuracy and safety of Eversense among adults with T1D or T2D through 90 days (NCT02647905). Accuracy measures included percentage system agreement and mean absolute relative difference (MARD) between Eversense and Yellow Springs Instrument reference measurements from 40 to 400 mg/dL. The primary safety endpoint was incidence of device-related or sensor insertion/removal procedure-related serious adverse events (SAEs) through 90 days. An updated glucose calculation algorithm was also applied to the sensor data from the PRECISE II study to evaluate consistency of accuracy results. Results: Thirty-five participants received the CGM system. Eighty-five percent of CGM values were within 15/15% of reference and the MARD value against reference was 9.6% (95% confidence interval [CI]: 8.9-10.4). All sensors were functional through day 90. No device- or procedure-related SAEs occurred. Application of the updated algorithm to PRECISE II sensor data resulted in 87% of readings within 15/15% of reference and an MARD value against reference of 8.5% (95% CI: 8.0%-9.1%). Conclusions: PRECISION corroborated prior accuracy and safety findings of the Eversense CGM System through the 90-day sensor life. The updated algorithm improved accuracy of measurements in PRECISE II.
Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Sistemas de Infusão de Insulina/efeitos adversos , Adulto , Idoso , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos TestesRESUMO
Background: The objective of this study was to assess the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm with variable glucose setpoints and moderate intensity exercise using an investigational device in adults with type 1 diabetes (T1D). Materials and Methods: A supervised 54-h hybrid closed-loop (HCL) study was conducted in a hotel setting after a 7-day outpatient standard treatment phase. Adults aged 18-65 years with T1D and HbA1c between 6.0% and 10.0% were eligible. Subjects completed two moderate intensity exercise sessions of >30 min duration on consecutive days: the first with the glucose set point increased from 130 to 150 mg/dL and the second with a temporary basal rate of 50%, both started 90 min pre-exercise. Primary endpoints were percentage time in hypoglycemia <70 mg/dL and hyperglycemia ≥250 mg/dL. Results: Twelve subjects participated in the study, with (mean ± standard deviation) age 36.5 ± 14.4 years, diabetes duration 21.7 ± 15.7 years, HbA1c 7.6% ± 1.1%, and total daily dose 0.60 ± 0.22 U/kg. Outcomes for the 54-h HCL period were mean glucose: 136 ± 14 mg/dL, percentage time <70 mg/dL: 1.4% ± 1.3%, 70-180 mg/dL: 85.1% ± 9.3%, and ≥250 mg/dL: 1.8% ± 2.4%. In the 12-h period after exercise start, percentage time <70 mg/dL was 1.4% ± 2.7% with the raised glucose set point and 1.6% ± 3.0% with reduced basal rate. The percentage time <70 mg/dL overnight was 0% ± 0% on both study nights. Conclusions: The Omnipod personalized MPC algorithm performed well and was safe during day and night use in response to variable glucose set points and with temporarily raised glucose set point or reduced basal rate 90 min in advance of moderate intensity exercise in adults with T1D.
Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Sistemas de Infusão de Insulina , Insulina/uso terapêutico , Adolescente , Adulto , Idoso , Algoritmos , Diabetes Mellitus Tipo 1/sangue , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
Fructose consumption in the USA has increased over the past three decades. During this time, obesity, insulin resistance and the metabolic syndrome have also increased in prevalence. While diets high in fructose have been shown to promote insulin resistance and increase TAG concentrations in animals, there are insufficient data available regarding the long-term metabolic effects of fructose consumption in humans. The objective of the present study was to investigate the metabolic effects of 10-week consumption of fructose-sweetened beverages in human subjects under energy-balanced conditions in a controlled research setting. Following a 4-week weight-maintaining complex carbohydrate diet, seven overweight or obese (BMI 26.8-33.3 kg/m2) postmenopausal women were fed an isoenergetic intervention diet, which included a fructose-sweetened beverage with each meal, for 10 weeks. The intervention diet provided 15 % of energy from protein, 30 % from fat and 55 % from carbohydrate (30 % complex carbohydrate, 25 % fructose). Fasting and postprandial glucose, insulin, TAG and apoB concentrations were measured. Fructose consumption increased fasting glucose concentrations and decreased meal-associated glucose and insulin responses (P = 0.0002, P = 0.007 and P = 0.013, respectively). Moreover, after 10 weeks of fructose consumption, 14 h postprandial TAG profiles were significantly increased, with the area under the curve at 10 weeks being 141 % higher than at baseline (P = 0.04). Fructose also increased fasting apoB concentrations by 19 % (P = 0.043 v. baseline). In summary, consumption of fructose-sweetened beverages increased postprandial TAG and fasting apoB concentrations, and the present results suggest that long-term consumption of diets high in fructose could lead to an increased risk of CVD.
Assuntos
Carboidratos da Dieta/efeitos adversos , Frutose/efeitos adversos , Obesidade/sangue , Sobrepeso/sangue , Idoso , Análise de Variância , Apolipoproteínas B/sangue , Área Sob a Curva , Bebidas , Biomarcadores/sangue , Glicemia/análise , Feminino , Humanos , Insulina/sangue , Lipídeos/sangue , Pessoa de Meia-Idade , Período Pós-Prandial , Tempo , Triglicerídeos/sangueRESUMO
BACKGROUND: This study assessed the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm using an investigational device in adults with type 1 diabetes in response to overestimated and missed meal boluses and extended boluses for high-fat meals. MATERIALS AND METHODS: A supervised 54-h hybrid closed-loop (HCL) study was conducted in a hotel setting after a 7-day outpatient open-loop run-in phase. Adults aged 18-65 years with type 1 diabetes and HbA1c 6.0%-10.0% were eligible. Primary endpoints were percentage time in hypoglycemia <70 mg/dL and hyperglycemia ≥250 mg/dL. Glycemic responses for 4 h to a 130% overestimated bolus and a missed meal bolus were compared with a 100% bolus for identical meals, respectively. The 12-h postprandial responses to a high-fat meal were compared using either a standard or extended bolus. RESULTS: Twelve subjects participated in the study, with (mean ± standard deviation): age 35.4 ± 14.1 years, diabetes duration 16.5 ± 9.3 years, HbA1c 7.7 ± 0.9%, and total daily dose 0.58 ± 0.19 U/kg. Outcomes for the 54-h HCL period were mean glucose 153 ± 15 mg/dL, percentage time <70 mg/dL [median (interquartile range)]: 0.0% (0.0-1.2%), 70-180 mg/dL: 76.1% ± 8.0%, and ≥250 mg/dL: 4.5% ± 3.6%. After both the 100% and 130% boluses, postprandial percentage time <70 mg/dL was 0.0% (0.0-0.0%) (P = 0.50). After the 100% and missed boluses, postprandial percentage time ≥250 mg/dL was 0.2% ± 0.6% and 10.3% ± 16.5%, respectively (P = 0.06). Postprandial percentages time ≥250 mg/dL and <70 mg/dL were similar with standard or extended boluses for a high-fat meal. CONCLUSIONS: The Omnipod personalized MPC algorithm performed well and was safe during day and night use in response to overestimated, missed, and extended meal boluses in adults with type 1 diabetes.
Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Adulto , Algoritmos , Glicemia , Comportamento Alimentar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas Artificial , Período Pós-Prandial , Adulto JovemRESUMO
BACKGROUND: Persistent use of real-time continuous glucose monitoring (CGM) improves diabetes control in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D). METHODS: PRECISE II was a nonrandomized, blinded, prospective, single-arm, multicenter study that evaluated the accuracy and safety of the implantable Eversense CGM system among adult participants with T1D and T2D (NCT02647905). The primary endpoint was the mean absolute relative difference (MARD) between paired Eversense and Yellow Springs Instrument (YSI) reference measurements through 90 days postinsertion for reference glucose values from 40 to 400 mg/dL. Additional endpoints included Clarke Error Grid analysis and sensor longevity. The primary safety endpoint was the incidence of device-related or sensor insertion/removal procedure-related serious adverse events (SAEs) through 90 days postinsertion. RESULTS: Ninety participants received the CGM system. The overall MARD value against reference glucose values was 8.8% (95% confidence interval: 8.1%-9.3%), which was significantly lower than the prespecified 20% performance goal for accuracy (P < 0.0001). Ninety-three percent of CGM values were within 20/20% of reference values over the total glucose range of 40-400 mg/dL. Clarke Error Grid analysis showed 99.3% of samples in the clinically acceptable error zones A (92.8%) and B (6.5%). Ninety-one percent of sensors were functional through day 90. One related SAE (1.1%) occurred during the study for removal of a sensor. CONCLUSIONS: The PRECISE II trial demonstrated that the Eversense CGM system provided accurate glucose readings through the intended 90-day sensor life with a favorable safety profile.
Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Desenho de Equipamento , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos TestesRESUMO
BACKGROUND: The safety and feasibility of the OmniPod personalized model predictive control (MPC) algorithm in adult, adolescent, and pediatric patients with type 1 diabetes were investigated. METHODS: This multicenter, observational trial included a 1-week outpatient sensor-augmented pump open-loop phase and a 36-h inpatient hybrid closed-loop (HCL) phase with announced meals ranging from 30 to 90 g of carbohydrates and limited physical activity. Patients aged 6-65 years with HbA1c between 6.0% and 10.0% were eligible. The investigational system included a modified version of OmniPod, the Dexcom G4 505 Share® AP System, and the personalized MPC algorithm running on a tablet computer. Primary endpoints included sensor glucose percentage of time in hypoglycemia <70 mg/dL and hyperglycemia >250 mg/dL. Additional glycemic targets were assessed. RESULTS: The percentage of time <70 mg/dL during the 36-h HCL phase was mean (standard deviation): 0.7 (1.7) in adults receiving 80% meal bolus (n = 24), and 0.7 (1.2) in adults (n = 10), 2.0 (2.4) in adolescents (n = 12), and 2.0 (2.6) in pediatrics (n = 12) receiving 100% meal bolus. The overall hypoglycemia rate was 0.49 events/24 h. The percentage of time >250 mg/dL was 8.0 (7.5), 3.6 (3.7), 4.9 (6.3), and 6.7 (5.6) in the study groups, respectively. Percentage of time in the target range of 70-180 mg/dL was 69.5 (14.4), 73.0 (15.0), 72.6 (15.5), and 70.1 (12.3), respectively. CONCLUSIONS: The OmniPod personalized MPC algorithm performed well and was safe during day and night use in adult, adolescent, and pediatric patients with type 1 diabetes. Longer term studies will assess the safety and performance of the algorithm under free living conditions with extended use.
Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina/efeitos adversos , Insulina/administração & dosagem , Adolescente , Adulto , Idoso , Algoritmos , Criança , Diabetes Mellitus Tipo 1/sangue , Estudos de Viabilidade , Feminino , Hemoglobinas Glicadas , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
BACKGROUND: This study evaluated the safety and performance of the Guardian™ continuous glucose monitoring (CGM) system in children and adolescents with type 1 diabetes (T1D). MATERIALS AND METHODS: Subjects 2-18 years of age (mean ± standard deviation [SD] 13.1 ± 3.9 years) with T1D and duration of diagnosis ≥1 year were enrolled at 11 sites in the United States and wore two Guardian Sensor 3 sensors in the abdomen and/or buttock. Sensors were connected to a transmitter paired with either a Guardian Connect system (i.e., mobile device with software application allowing display of sensor glucose [SG] values) or a Guardian Link 3 transmitter used as a Glucose Sensor Recorder (GSR). There were 145 participants who underwent a 6-h in-clinic frequent sample testing (FST) on day 1 (n = 54), day 3 (n = 48), or day 7 (n = 43) postsensor insertion. During FST, SG values were compared with a Yellow Springs Instrument (YSI) plasma reference every 5-15 min (n = 124, 7-18 years of age; n = 2, 2-6 years of age), or to a self-monitoring of blood glucose (SMBG) reference every 5-30 min (n = 19, 2-6 years of age). RESULTS: The overall mean absolute relative difference (ARD ± SD) between SG and reference values (YSI or SMBG) when calibrating approximately every 12 h, was 10.9% ± 10.7% (3102 paired points) for sensors communicating with the Guardian Connect system and 11.1% ± 10.6% (2624 paired points) for sensors connected to the GSR. The overall percentage of SG values within ±20% of reference values >80 mg/dL or within 20 mg/dL of reference values ≤80 mg/dL was 87.8% for the Guardian Connect system and 86.7% for the GSR, respectively. There was one device-related adverse event of contact dermatitis, but no serious device-related adverse events. CONCLUSIONS: The Guardian CGM system demonstrated good accuracy in children and adolescents. These findings support its use in sensor-integrated insulin pump platforms, as well as a standalone technology, for managing diabetes in pediatric populations.