Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 49(2): 596-608, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34374796

RESUMO

PURPOSE: To assess whether a radiomics and machine learning (ML) model combining quantitative parameters and radiomics features extracted from simultaneous multiparametric 18F-FDG PET/MRI can discriminate between benign and malignant breast lesions. METHODS: A population of 102 patients with 120 breast lesions (101 malignant and 19 benign) detected on ultrasound and/or mammography was prospectively enrolled. All patients underwent hybrid 18F-FDG PET/MRI for diagnostic purposes. Quantitative parameters were extracted from DCE (MTT, VD, PF), DW (mean ADC of breast lesions and contralateral breast parenchyma), PET (SUVmax, SUVmean, and SUVminimum of breast lesions, as well as SUVmean of the contralateral breast parenchyma), and T2-weighted images. Radiomics features were extracted from DCE, T2-weighted, ADC, and PET images. Different diagnostic models were developed using a fine Gaussian support vector machine algorithm which explored different combinations of quantitative parameters and radiomics features to obtain the highest accuracy in discriminating between benign and malignant breast lesions using fivefold cross-validation. The performance of the best radiomics and ML model was compared with that of expert reader review using McNemar's test. RESULTS: Eight radiomics models were developed. The integrated model combining MTT and ADC with radiomics features extracted from PET and ADC images obtained the highest accuracy for breast cancer diagnosis (AUC 0.983), although its accuracy was not significantly higher than that of expert reader review (AUC 0.868) (p = 0.508). CONCLUSION: A radiomics and ML model combining quantitative parameters and radiomics features extracted from simultaneous multiparametric 18F-FDG PET/MRI images can accurately discriminate between benign and malignant breast lesions.


Assuntos
Neoplasias da Mama , Fluordesoxiglucose F18 , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Máquina de Vetores de Suporte
2.
Eur Radiol ; 30(3): 1451-1459, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31797077

RESUMO

OBJECTIVES: To investigate whether the application of the Kaiser score for breast magnetic resonance imaging (MRI) might downgrade breast lesions that present as mammographic calcifications and avoid unnecessary breast biopsies METHODS: This IRB-approved, retrospective, cross-sectional, single-center study included 167 consecutive patients with suspicious mammographic calcifications and histopathologically verified results. These patients underwent a pre-interventional breast MRI exam for further diagnostic assessment before vacuum-assisted stereotactic-guided biopsy (95 malignant and 72 benign lesions). Two breast radiologists with different levels of experience independently read all examinations using the Kaiser score, a machine learning-derived clinical decision-making tool that provides probabilities of malignancy by a formalized combination of diagnostic criteria. Diagnostic performance was assessed by receiver operating characteristics (ROC) analysis and inter-reader agreement by the calculation of Cohen's kappa coefficients. RESULTS: Application of the Kaiser score revealed a large area under the ROC curve (0.859-0.889). Rule-out criteria, with high sensitivity, were applied to mass and non-mass lesions alike. The rate of potentially avoidable breast biopsies ranged between 58.3 and 65.3%, with the lowest rate observed with the least experienced reader. CONCLUSIONS: Applying the Kaiser score to breast MRI allows stratifying the risk of breast cancer in lesions that present as suspicious calcifications on mammography and may thus avoid unnecessary breast biopsies. KEY POINTS: • The Kaiser score is a helpful clinical decision tool for distinguishing malignant from benign breast lesions that present as calcifications on mammography. • Application of the Kaiser score may obviate 58.3-65.3% of unnecessary stereotactic biopsies of suspicious calcifications. • High Kaiser scores predict breast cancer with high specificity, aiding clinical decision-making with regard to re-biopsy in case of negative results.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Lobular/diagnóstico por imagem , Tomada de Decisão Clínica , Sistemas de Apoio a Decisões Clínicas , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Mama/patologia , Neoplasias da Mama/patologia , Calcinose/patologia , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Lobular/patologia , Estudos Transversais , Feminino , Humanos , Biópsia Guiada por Imagem , Aprendizado de Máquina , Imageamento por Ressonância Magnética , Mamografia , Pessoa de Meia-Idade , Probabilidade , Curva ROC , Radiologistas , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
3.
Clin Radiol ; 75(2): 157.e1-157.e7, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31690449

RESUMO

AIM: To report prostate cancer (PCa) prevalence in Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) categories and investigate the potential to avoid unnecessary, magnetic resonance imaging (MRI)-guided in-bore biopsies by adding clinical and biochemical patient characteristics. MATERIALS AND METHODS: The present institutional review board-approved, prospective study on 137 consecutive men with 178 suspicious lesions on 3 T MRI was performed. Routine data collected for each patient included patient characteristics (age, prostate volume), clinical background information (prostate-specific antigen [PSA] levels, PSA density), and PI-RADS v2 scores assigned in a double-reading approach. RESULTS: Histopathological evaluation revealed a total of 93/178 PCa (52.2%). The mean age was 66.3 years and PSA density was 0.24 ng/ml2 (range, 0.04-0.89 ng/ml). Clinically significant PCa (csPCa, Gleason score >6) was confirmed in 50/93 (53.8%) lesions and was significantly associated with higher PI-RADS v2 scores (p=0.0044). On logistic regression analyses, age, PSA density, and PI-RADS v2 scores contributed independently to the diagnosis of csPCa (p=7.9×10-7, p=0.097, and p=0.024, respectively). The resulting area under the receiver operating characteristic curve (AUC) to predict csPCa was 0.76 for PI-RADS v2, 0.59 for age, and 0.67 for PSA density. The combined regression model yielded an AUC of 0.84 for the diagnosis of csPCa and was significantly superior to each single parameter (p≤0.0009, respectively). Unnecessary biopsies could have been avoided in 50% (64/128) while only 4% (2/50) of csPCa lesions would have been missed. CONCLUSIONS: Adding age and PSA density to PI-RADS v2 scores improves the diagnostic accuracy for csPCa. A combination of these variables with PI-RADS v2 can help to avoid unnecessary in-bore biopsies while still detecting the majority of csPCa.


Assuntos
Neoplasias da Próstata/diagnóstico , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Próstata/diagnóstico por imagem , Próstata/patologia , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
4.
Radiologe ; 59(6): 510-516, 2019 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-31001650

RESUMO

BACKGROUND: Contrast-enhanced breast magnetic resonance imaging (MRI) is the most sensitive method for detection of breast cancer. The further spread of breast MRI is limited by the complicated examination procedure and the need for intravenously administered contrast media. OBJECTIVES: Can diffusion-weighted imaging (DWI) replace contrast-enhanced sequences to achieve an unenhanced breast MRI examination? MATERIALS AND METHODS: Narrative review and meta-analytic assessment of previously published studies. RESULTS: DWI can visualize breast lesions and distinguish benign from malignant findings. It is thus a valid alternative to contrast-enhanced sequences. As an additional technique, the use of DWI can reduce the numbers of unnecessary breast biopsies. The lack of robustness leading to variable sensitivity that is currently lower than that of contrast-enhanced breast MRI is a disadvantage of DWI. CONCLUSIONS: Presently, DWI can be recommended as an integral part of clinical breast MRI protocols. The application as a stand-alone technique within unenhanced protocols is still under evaluation.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética , Sensibilidade e Especificidade
5.
Eur Radiol ; 26(11): 3917-3922, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27108300

RESUMO

PURPOSE: To evaluate the inter-/intra-observer agreement of BI-RADS-based subjective visual estimation of the amount of fibroglandular tissue (FGT) with magnetic resonance imaging (MRI), and to investigate whether FGT assessment benefits from an automated, observer-independent, quantitative MRI measurement by comparing both approaches. MATERIALS AND METHODS: Eighty women with no imaging abnormalities (BI-RADS 1 and 2) were included in this institutional review board (IRB)-approved prospective study. All women underwent un-enhanced breast MRI. Four radiologists independently assessed FGT with MRI by subjective visual estimation according to BI-RADS. Automated observer-independent quantitative measurement of FGT with MRI was performed using a previously described measurement system. Inter-/intra-observer agreements of qualitative and quantitative FGT measurements were assessed using Cohen's kappa (k). RESULTS: Inexperienced readers achieved moderate inter-/intra-observer agreement and experienced readers a substantial inter- and perfect intra-observer agreement for subjective visual estimation of FGT. Practice and experience reduced observer-dependency. Automated observer-independent quantitative measurement of FGT was successfully performed and revealed only fair to moderate agreement (k = 0.209-0.497) with subjective visual estimations of FGT. CONCLUSION: Subjective visual estimation of FGT with MRI shows moderate intra-/inter-observer agreement, which can be improved by practice and experience. Automated observer-independent quantitative measurements of FGT are necessary to allow a standardized risk evaluation. KEY POINTS: • Subjective FGT estimation with MRI shows moderate intra-/inter-observer agreement in inexperienced readers. • Inter-observer agreement can be improved by practice and experience. • Automated observer-independent quantitative measurements can provide reliable and standardized assessment of FGT with MRI.


Assuntos
Neoplasias da Mama/patologia , Adulto , Densidade da Mama , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Adulto Jovem
6.
Clin Radiol ; 71(9): 889-95, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27210245

RESUMO

AIM: To examine the interpretive performance of digital breast tomosynthesis (DBT) as an adjunct to digital mammography (DM) compared to DM alone in a series of invasive lobular carcinomas (ILCs) and to assess whether DBT can be used to characterise ILC. MATERIALS AND METHODS: A retrospective, multi-reader study was conducted of 83 mammographic examinations of women with 107 newly diagnosed ILCs ascertained at histology. Consenting women underwent both DM and DBT acquisitions. Twelve radiologists, with varying mammography experience, interpreted DM images alone, reporting lesion location, mammographic features, and malignancy probability using the Breast Imaging-Reporting and Data System (BI-RADS) categories 1-5; they then reviewed DBT images in addition to DM, and reported the same parameters. Statistical analyses compared sensitivity, false-positive rates (FPR), and interpretive performance using the receiver operating characteristics (ROC) curve and the area under the curve (AUC), for reading with DM versus DM plus DBT. RESULTS: Multi-reader pooled ROC analysis for DM plus DBT yielded AUC=0.89 (95% confidence interval [CI]: 0.88-0.91), which was significantly higher (p<0.0001) than DM alone with AUC=0.84 (95% CI: 0.82-0.86). DBT plus DM significantly increased pooled sensitivity (85%) compared to DM alone (70%; p<0.0001). FPR did not vary significantly with the addition of DBT to DM. Interpreting with DBT (compared to DM alone) increased the correct identification of ILCs depicted as architectural distortions (84% versus 65%, respectively) or as masses (89% versus 70%), increasing interpretive performance for both experienced and less-experienced readers; larger gains in AUC were shown for less-experienced radiologists. Multifocal and/or multicentric and bilateral disease was more frequently identified on DM with DBT. CONCLUSION: Adding DBT to DM significantly improved the accuracy of mammographic interpretation for ILCs and contributed to characterising disease extent.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/patologia , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Idoso , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Invasividade Neoplásica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
7.
Eur Radiol ; 24(9): 2213-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24792515

RESUMO

PURPOSE: To intra-individually compare the diagnostic image quality of Dixon and spectral fat suppression at 3 T. METHODS: Fifty consecutive patients (mean age 55.1 years) undergoing 3 T breast MRI were recruited for this prospective study. The image protocol included pre-contrast and delayed post-contrast spectral and Dixon fat-suppressed T1w series. Two independent blinded readers compared spectral and Dixon fat-suppressed series by evaluating six ordinal (1 worst to 5 best) image quality criteria (image quality, delineation of anatomical structures, fat suppression in the breast and axilla, lesion delineation and internal enhancement). Breast density and size were assessed. Data analysis included Spearman's rank correlation coefficient and visual grading characteristics (VGC) analysis. RESULTS: Four examinations were excluded; 48 examinations in 46 patients were evaluated. In VGC analysis, the Dixon technique was superior regarding image quality criteria analysed (P < 0.01). Smaller breast size and lower breast density were significantly (P < 0.01) correlated with impaired spectral fat suppression quality. No such correlation was identified for the Dixon technique, which showed reconstruction-based water-fat mixups leading to insufficient image quality in 20.8%. CONCLUSIONS: The Dixon technique outperformed spectral fat suppression in all evaluated criteria (P < 0.01). Non-diagnostic examinations can be avoided by fat and water image reconstruction. The superior image quality of the Dixon technique can improve breast MRI interpretation. KEY POINTS: Optimal fat suppression quality is necessary for optimal image interpretation. Superior fat suppression quality is achieved using the Dixon technique. Lesion margin and internal enhancement evaluation improves using the Dixon technique. Superior image quality of the Dixon technique improves breast MRI interpretation.


Assuntos
Tecido Adiposo/patologia , Neoplasias da Mama/diagnóstico , Mama/patologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Gradação de Tumores/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Eur J Radiol ; 176: 111520, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38820953

RESUMO

PURPOSE: To adapt the methodology of the Kaiser score, a clinical decision rule for lesion characterization in breast MRI, for unenhanced protocols. METHOD: In this retrospective IRB-approved cross-sectional study, we included 93 consecutive patients who underwent breast MRI between 2021 and 2023 for further work-up of BI-RADS 0, 3-5 in conventional imaging or for staging purposes (BI-RADS 6). All patients underwent biopsy for histologic verification or were followed for a minimum of 12 months. MRI scans were conducted using 1.5 T or 3 T scanners using dedicated breast coils and a protocol in line with international recommendations including DWI and ADC. Lesion characterization relied solely on T2w and DWI/ADC-derived features (such as lesion type, margins, shape, internal signal, surrounding tissue findings, ADC value). Statistical analysis was done using decision tree analysis aiming to distinguish benign (histology/follow-up) from malignant outcomes. RESULTS: We analyzed a total of 161 lesions (81 of them non-mass) with a malignancy rate of 40%. Lesion margins (spiculated, irregular, or circumscribed) were identified as the most important criterion within the decision tree, followed by the ADC value as second most important criterion. The resulting score demonstrated a strong diagnostic performance with an AUC of 0.840, providing both rule-in and rule-out criteria. In an independent test set of 65 lesions the diagnostic performance was verified by two readers (AUC 0.77 and 0.87, kappa: 0.62). CONCLUSIONS: We developed a clinical decision rule for unenhanced breast MRI including lesion margins and ADC value as the most important criteria, achieving high diagnostic accuracy.


Assuntos
Neoplasias da Mama , Imageamento por Ressonância Magnética , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Imageamento por Ressonância Magnética/métodos , Idoso , Estudos Transversais , Sensibilidade e Especificidade , Reprodutibilidade dos Testes
9.
Eur J Radiol ; 170: 111271, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38185026

RESUMO

PURPOSE: We aimed to investigate the effect of using visual or automatic enhancement curve type assessment on the diagnostic performance of the Kaiser Score (KS), a clinical decision rule for breast MRI. METHOD: This IRB-approved retrospective study analyzed consecutive conventional BI-RADS 0, 4 or 5 patients who underwent biopsy after 1.5T breast MRI according to EUSOBI recommendations between 2013 and 2015. The KS includes five criteria (spiculations; signal intensity (SI)-time curve type; margins of the lesion; internal enhancement; and presence of edema) resulting in scores from 1 (=lowest) to 11 (=highest risk of breast cancer). Enhancement curve types (Persistent, Plateau or Wash-out) were assessed by two radiologists independently visually and using a pixel-wise color-coded computed parametric map of curve types. KS diagnostic performance differences between readings were compared by ROC analysis. RESULTS: In total 220 lesions (147 benign, 73 malignant) including mass (n = 148) and non-mass lesions (n = 72) were analyzed. KS reading performance in distinguishing benign from malignant lesions did not differ between visual analysis and parametric map (P = 0.119; visual: AUC 0.875, sensitivity 95 %, specificity 63 %; and map: AUC 0.901, sensitivity 97 %, specificity 65 %). Additionally, analyzing mass and non-mass lesions separately, showed no difference between parametric map based and visual curve type-based KS analysis as well (P = 0.130 and P = 0.787). CONCLUSIONS: The performance of the Kaiser Score is largely independent of the curve type assessment methodology, confirming its robustness as a clinical decision rule for breast MRI in any type of breast lesion in clinical routine.


Assuntos
Neoplasias da Mama , Regras de Decisão Clínica , Humanos , Feminino , Estudos Retrospectivos , Mama/patologia , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Curva ROC , Computadores , Sensibilidade e Especificidade , Meios de Contraste
10.
Eur J Radiol ; 171: 111312, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38237520

RESUMO

BACKGROUND: Contrast-enhanced breast MRI and recently also contrast-enhanced mammography (CEM) are available for breast imaging. The aim of the current overview is to explore existing evidence and ongoing challenges of contrast-enhanced breast imaging. METHODS: This narrative provides an introduction to the contrast-enhanced breast imaging modalities breast MRI and CEM. Underlying principle, techniques and BI-RADS reporting of both techniques are described and compared, and the following indications and ongoing challenges are discussed: problem-solving, high-risk screening, supplemental screening in women with extremely dense breast tissue, breast implants, neoadjuvant systemic therapy (NST) response monitoring, MRI-guided and CEM- guided biopsy. RESULTS: Technique and reporting for breast MRI are standardised, for the newer CEM standardisation is in progress. Similarly, compared to other modalities, breast MRI is well established as superior for problem-solving, screening women at high risk, screening women with extremely dense breast tissue or with implants; and for monitoring response to NST. Furthermore, MRI-guided biopsy is a reliable technique with low long-term false negative rates. For CEM, data is as yet either absent or limited, but existing results in these settings are promising. CONCLUSION: Contrast-enhanced breast imaging achieves highest diagnostic performance and should be considered essential. Of the two contrast-enhanced modalities, evidence of breast MRI superiority is ample, and preliminary results on CEM are promising, yet CEM warrants further study.


Assuntos
Neoplasias da Mama , Mamografia , Feminino , Humanos , Mama/diagnóstico por imagem , Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos
11.
Clin Biomech (Bristol, Avon) ; 110: 106117, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37826970

RESUMO

BACKGROUND: A typical problem in the registration of MRI and X-ray mammography is the nonlinear deformation applied to the breast during mammography. We have developed a method for virtual deformation of the breast using a biomechanical model automatically constructed from MRI. The virtual deformation is applied in two steps: unloaded state estimation and compression simulation. The finite element method is used to solve the deformation process. However, the extensive computational cost prevents its usage in clinical routine. METHODS: We propose three machine learning models to overcome this problem: an extremely randomized tree (first model), extreme gradient boosting (second model), and deep learning-based bidirectional long short-term memory with an attention layer (third model) to predict the deformation of a biomechanical model. We evaluated our methods with 516 breasts with realistic compression ratios up to 76%. FINDINGS: We first applied one-fold validation, in which the second and third models performed better than the first model. We then applied ten-fold validation. For the unloaded state estimation, the median RMSE for the second and third models is 0.8 mm and 1.2 mm, respectively. For the compression, the median RMSE is 3.4 mm for both models. We evaluated correlations between model accuracy and characteristics of the clinical datasets such as compression ratio, breast volume, and tissue types. INTERPRETATION: Using the proposed models, we achieved accurate results comparable to the finite element model, with a speedup of factor 240 using the extreme gradient boosting model. These proposed models can replace the finite element model simulation, enabling clinically relevant real-time application.


Assuntos
Mama , Mamografia , Humanos , Mama/diagnóstico por imagem , Mamografia/métodos , Simulação por Computador , Imageamento por Ressonância Magnética/métodos , Aprendizado de Máquina , Análise de Elementos Finitos , Fenômenos Biomecânicos
12.
Eur J Radiol ; 154: 110436, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35939989

RESUMO

PURPOSE: To assess the impact of abbreviated breast MRI protocols on patient throughput considering non-scanning time and differences between in- and out-of-hospital settings. MATERIALS & METHODS: A total of 143 breast MRI exams from four study sites (hospital, three radiology centers) were included in this retrospective study. Total exam time (TET), Table Time (TT), Scan Time (ST), Table Switch Time (TST) and Planning Time (PT) were determined from consecutive breast MRI examinations. Possible number of scans and exams per hour were calculated. Four scan protocols were compared: full diagnostic protocol (n = 34, hospital), split dynamic protocol (n = 109, all sites) and two abbreviated protocols (n = 109, calculated, all sites). Data were described as median and interquartile range (IQR) and compared by Mann-Whitney-U-Test. RESULTS: Non-scanning time increased from 50% to 74% of the TET with a TST of 46% and a PT of 28% in the shortest abbreviated protocol. Number of possible scans per hour increased from 4.7 to 18.8 while number of possible exams per hour only increased from 2.3 to 5.1. Absolute TST (4.7 vs. 5.7 min, p = 0.46) and TET (18 min each, p = 0.35) did not differ significantly between in- and out-of-hospital exams. Absolute (4.4 vs. 2.8 min, p < 0.001) and relative (23 vs. 13%, p < 0.001) PT and TT (13.3 vs. 11.5 min, p = 0.004) was longer and relative TST (27% vs. 34%, p = 0.047) was shorter in hospital. CONCLUSION: TST and PT significantly contribute to TET and challenge the effectiveness of abbreviated protocols for increasing patient throughput. These findings show only low setting-dependent differences.


Assuntos
Neoplasias da Mama , Radiologia , Mama , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Radiografia , Estudos Retrospectivos
13.
Eur J Radiol ; 154: 110431, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35803101

RESUMO

PURPOSE: To test the inter-reader agreement of the Prostate Imaging Quality (PI-QUAL) score for multiparametric prostate MRI and its impact on diagnostic performance in an MRI-ultrasound fusion biopsy population. PATIENTS AND METHODS: Pre-biopsy multiparametric (T2-weighted, DWI, and DCE) prostate MRIs (mpMRI) of 50 patients undergoing transrectal ultrasound-guided MRI-fusion (MRI-TRUS) biopsy were included. Two radiologists independently assigned a PI-QUAL score to each patient and assessed the diagnostic quality of individual sequences. PI-RADS categories were assigned to six regions per prostate (left and right: base/mid-glandular/apex). Inter-reader agreement was calculated using Cohen's kappa and diagnostic performance was compared by the area under the receiver operating characteristics curve (AUC). RESULTS: In 274 diagnostic areas, the malignancy rate was 62.7% (22.5% clinically significant prostate cancer, ISUP ≥ 2). Inter-reader agreement for the diagnostic quality was poor for T2w (kappa 0.19), fair for DWI and DCE (kappa 0.23 and 0.29) and moderate for PI-QUAL (kappa 0.51). For PI-RADS category assignments, inter-reader agreement was very good (kappa 0.86). Overall diagnostic performance did not differ between studies with a PI-QUAL score > 3 compared to a score ≤ 3 (p = 0.552; AUC 0.805 and 0.839). However, the prevalence of prostate cancer was significantly lower when the PI-QUAL score was ≤ 3 (16.7% vs. 30.2%, p = 0.008). CONCLUSION: PI-QUAL has only a limited impact on PI-RADS diagnostic performance in patients scheduled for MRI-TRUS fusion biopsy. However, the lower cancer prevalence in the lower PI-QUAL categories points out a risk of false-positive referrals and unnecessary biopsies if prostate imaging quality is low.


Assuntos
Próstata , Neoplasias da Próstata , Biópsia , Humanos , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Ultrassonografia
14.
Sci Rep ; 11(1): 2501, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33510306

RESUMO

To investigate the performance of multiparametric ultrasound for the evaluation of treatment response in breast cancer patients undergoing neoadjuvant chemotherapy (NAC). The IRB approved this prospective study. Breast cancer patients who were scheduled to undergo NAC were invited to participate in this study. Changes in tumour echogenicity, stiffness, maximum diameter, vascularity and integrated backscatter coefficient (IBC) were assessed prior to treatment and 7 days after four consecutive NAC cycles. Residual malignant cell (RMC) measurement at surgery was considered as standard of reference. RMC < 30% was considered a good response and > 70% a poor response. The correlation coefficients of these parameters were compared with RMC from post-operative histology. Linear Discriminant Analysis (LDA), cross-validation and Receiver Operating Characteristic curve (ROC) analysis were performed. Thirty patients (mean age 56.4 year) with 42 lesions were included. There was a significant correlation between RMC and echogenicity and tumour diameter after the 3rd course of NAC and average stiffness after the 2nd course. The correlation coefficient for IBC and echogenicity calculated after the first four doses of NAC were 0.27, 0.35, 0.41 and 0.30, respectively. Multivariate analysis of the echogenicity and stiffness after the third NAC revealed a sensitivity of 82%, specificity of 90%, PPV = 75%, NPV = 93%, accuracy = 88% and AUC of 0.88 for non-responding tumours (RMC > 70%). High tumour stiffness and persistent hypoechogenicity after the third NAC course allowed to accurately predict a group of non-responding tumours. A correlation between echogenicity and IBC was demonstrated as well.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/terapia , Ultrassonografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Terapia Neoadjuvante , Neovascularização Patológica/diagnóstico por imagem , Estudos Prospectivos , Curva ROC , Resultado do Tratamento , Carga Tumoral , Ultrassonografia/métodos
15.
Eur J Radiol ; 132: 109309, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33010682

RESUMO

OBJECTIVES: To investigate whether combined texture analysis and machine learning can distinguish malignant from benign suspicious mammographic calcifications, to find an exploratory rule-out criterion to potentially avoid unnecessary benign biopsies. METHODS: Magnification views of 235 patients which underwent vacuum-assisted biopsy of suspicious calcifications (BI-RADS 4) during a two-year period were retrospectively analyzed using the texture analysis tool MaZda (Version 4.6). Microcalcifications were manually segmented and analyzed by two readers, resulting in 249 image features from gray-value histogram, gray-level co-occurrence and run-length matrices. After feature reduction with principal component analysis (PCA), a multilayer perceptron (MLP) artificial neural network was trained using histological results as the reference standard. For training and testing of this model, the dataset was split into 70 % and 30 %. ROC analysis was used to calculate diagnostic performance indices. RESULTS: 226 patients (150 benign, 76 malignant) were included in the final analysis due to missing data in 9 cases. Feature selection yielded nine image features for MLP training. Area under the ROC-curve in the testing dataset (n = 54) was 0.82 (95 %-CI: 0.70-0.94) and 0.832 (95 %-CI 0.72-0.94) for both readers, respectively. A high sensitivity threshold criterion was identified in the training dataset and successfully applied to the testing dataset, demonstrating the potential to avoid 37.1-45.7 % of unnecessary biopsies at the cost of one false-negative for each reader. CONCLUSION: Combined texture analysis and machine learning could be used for risk stratification in suspicious mammographic calcifications. At low costs in terms of false-negatives, unnecessary biopsies could be avoided.


Assuntos
Neoplasias da Mama , Calcinose , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Humanos , Aprendizado de Máquina , Mamografia , Curva ROC , Estudos Retrospectivos
16.
Eur J Pharmacol ; 174(2-3): 215-25, 1989 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-2630299

RESUMO

Ischemia strokes appear to be the main source of cochleo-vestibular dysfunctions of peripheral origin. The present study aimed to investigate the action of oxygen free radicals on the bioelectric activity of the labyrinthine epithelium, using the frog semicircular canal as an in vitro preparation. We also examined the possible effect of the antianginal drug, trimetazidine (TMZ), under physiological conditions and during the administration of phenazine methosulfate (PMS). The model allows the ionic composition of endolymphatic and perilymphatic fluids bathing the semicircular canal to be dealt with separately. Spontaneous afferent vestibular nerve activity and the endolymphatic potential were recorded under resting conditions. Three additional parameters were investigated during mechanical displacement of the endolymphatic fluid: the ampullar direct current, the nerve direct current and the frequency of the evoked afferent spikes. Addition of TMZ (10(-6) and 10(-5) M, 50 min) into the perilymphatic compartment did not induce significant modifications of the different bioelectrical signals. Generation of oxygen free radicals, through administration of PMS (10(-5) M, 15 min) into the perilymphatic compartment, caused an impairment of all bioelectrical signals, except the ampullar direct current. The spontaneous activity, nerve direct current and frequency of afferent evoked spikes signals were significantly reduced 75 min after the start of PMS administration (-64, -17 and -32%, respectively). In contrast, there was a marked increase of the endolymphatic potential signal (+51%). Addition of TMZ (10(-6) or 10(-5) M) into the perilymph solution reversed the effect of PMS on all bioelectrical signals. These results indicate that TMZ acts as an antioxidant molecule which is capable of protecting the labyrinthine epithelium from the deleterious effect of oxygen radicals. Our data suggest that the protective effect of TMZ on ischemia-induced cochleo-vestibular dysfunctions may be accounted for by the antioxidant properties of this antianginal drug.


Assuntos
Antioxidantes/farmacologia , Metilfenazônio Metossulfato/farmacologia , Fenazinas/farmacologia , Piperazinas/farmacologia , Canais Semicirculares/efeitos dos fármacos , Trimetazidina/farmacologia , Animais , Eletrofisiologia , Potenciais Evocados/efeitos dos fármacos , Concentração de Íons de Hidrogênio , Técnicas In Vitro , Masculino , Neurônios Aferentes/efeitos dos fármacos , Estimulação Física , Rana ridibunda
17.
Ann Otolaryngol Chir Cervicofac ; 107 Suppl 1: 28-35, 1990.
Artigo em Francês | MEDLINE | ID: mdl-2240996

RESUMO

Improvement of cochleovestibular symptoms induced by trimetazidine (TMZ) has been evidenced by clinical studies. However, a poor knowledge of the physiopathology and the scarcity of experimental models contributed to making determination of the mode of action of the drugs difficult. We studied the effect, in vitro, of TMZ on the production of oxygen-derived free radicals using, as a biological model, the isolated semicircular canal of the frog. This model allows to exert separate control over the ionic composition of the endo- and perilymphatic fluids. The spontaneous activity of the afferent nerve fibers, as well as the endolymphatic potential, were recorded at rest. Three additional parameters were analyzed, while the semicircular canal was subjected to mechanical stimulation, i.e., ampulla potential, nerve potential and the evoked frequency of action potentials. Free radical generation induced by the administration of phenazine methosulfate (PMS, 10(-5) M, 15 min) into the perilymphatic compartment, leads to a deterioration of the production of endolymph and the release of this afferent neuromediator. Inversely, PMS has no influence whatsoever on the mechanisms of mechanical-electrical transduction. The addition of TMZ (10(-6) or 10(-5) M) in the perilymphatic compartment counteracts the harmful effects of free radicals on the various bioelectric activities. These results suggest that the beneficial action of TMZ observed during treatment of cochleovestibular disorders is due, at least in part, to the anti-oxidizing properties of the molecule of interest.


Assuntos
Antioxidantes , Oxigênio/farmacocinética , Canais Semicirculares/metabolismo , Trimetazidina/farmacologia , Potenciais de Ação/efeitos dos fármacos , Animais , Endolinfa/metabolismo , Potenciais Evocados/efeitos dos fármacos , Radicais Livres , Masculino , Metilfenazônio Metossulfato/efeitos adversos , Fibras Nervosas/efeitos dos fármacos , Neurônios Aferentes/efeitos dos fármacos , Perilinfa/metabolismo , Rana ridibunda , Canais Semicirculares/efeitos dos fármacos , Canais Semicirculares/inervação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA