1.
Artigo em Inglês | MEDLINE | ID: mdl-38987046

RESUMO

BACKGROUND: In patients undergoing transcatheter aortic valve replacement (TAVR), elevated pre-procedural C-reactive protein (CRP) levels are frequently observed. Its impact on long-term results of TAVR is unclear. The aim of the study was to investigate the long-term (up to six years) clinical outcomes of TAVR patients with normal compared to elevated CRP levels before TAVR. METHODS: Consecutive patients undergoing TAVR between August 2012 and January 2023 at a tertiary cardiology facility were included. Patients were divided into two cohorts based on the baseline CRP levels: normal CRP (≤ 5 mg/l) and elevated CRP (>5 mg/l). The cohorts were followed clinically for up to six years after TAVR. RESULTS: From a total of 1000 TAVR patients (mean age 81 ± 6 years), 268 patients (27 %) were found to have elevated baseline CRP (>5 mg/l). Such patients had significantly more co-morbidities (e.g. chronic obstructive pulmonary disease, atrial fibrillation, heart failure, concomitant valvopathies). They also developed periprocedural infections more frequently (3 % vs. 1 %, p = 0.007) and required more commonly repeat hospitalizations for infections during follow-up (HR 1.97, CI 1.47-2.64, p < 0.001). All-cause mortality and development of valve dysfunction did not significantly differ between patients with elevated and normal baseline CRP levels. CONCLUSION: Albeit long-term results of TAVR patients with elevated pre-procedural CRP levels seem favorable in terms of survival and development of valve dysfunction, they have an increased risk for periprocedural infections and re-admissions due to infections of any type during the follow-up period.

2.
J Invasive Cardiol ; 36(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38412438

RESUMO

OBJECTIVES: Percutaneous closure of a patent foramen ovale (PFO) for the prevention of recurrent paradoxical thromboembolic events has been shown to be safe and effective in randomized controlled trials. However, it remains uncertain if differences in the structure and design of the occluder devices impact the outcomes. The aim of this study was to compare results of percutaneous PFO closure using 2 widely used double-disc occluders. METHODS: Consecutive patients who underwent percutaneous PFO closure with the Abbott Amplatzer occluder (APO) or the Occlutech Figulla-Flex-II occluder (OPO) at the Heart Center Lucerne between February 2017 and December 2022 were included in a registry. The primary endpoint was effective closure of the PFO, defined as a residual shunt grade 0 or 1, assessed by contrast echocardiogram at 6-month follow-up. Secondary endpoints included procedural efficacy/safety and major adverse cardiovascular events during the hospital stay and at 6-month follow-up. RESULTS: One hundred ninety-three consecutive patients (mean age 51.7 ± 12.5 years; 39% women; Risk of Paradoxical Embolism (RoPE) score = 7, IQR = 6-8) underwent percutaneous PFO closure with the APO (120 patients, 62.2%) or the OPO (73 patients, 37.8%). Main indications for closure were crypotogenic stroke in 168 patients (87.1%) and peripheral embolism in 13 patients (6.7%). At baseline, right-to-left shunt (RLS) greater than or equal to grade 2 was present in 189 patients (97.9%). Immediate procedural success was 99.5%. In 1 patient, an air embolism occurred during positioning of the APO occluder with transient chest pain and electrocardiogram changes, but without further sequelae to the patient. At 6-month follow-up, effective closure was achieved in 185 patients (95.8%; APO: 96.6% vs OPO: 94.5%, P = .30). Rates of atrial fibrillation and recurrent thromboembolic events were 4.2 and 0.5%, respectively. CONCLUSIONS: PFO closure is safe and effective when performed with either the self-expanding Abbott Amplatzer or Occlutech Figulla Flex II PFO occluder.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Tromboembolia , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Forame Oval Patente/diagnóstico , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Resultado do Tratamento , Ecocardiografia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Dispositivo para Oclusão Septal/efeitos adversos , Tromboembolia/etiologia , Cateterismo Cardíaco/métodos
3.
J Invasive Cardiol ; 35(12)2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38108869

RESUMO

OBJECTIVES: The Allegra-THV is a novel, self-expanding THV with supra-annular bovine leaflets. The valve is available in 3 different sizes and is delivered through an 18 French sheath. To determine the safety and efficacy of the Allegra transcatheter heart valve (THV; Biosensors) for the treatment of severe aortic valve stenosis under real-world conditions. METHODS: Consecutive patients undergoing transcatheter aortic valve replacement (TAVR) at the Heart-Centre Lucerne with the Allegra-THV were included. Echocardiographic data were collected at baseline, before discharge, and at 1-year follow-up; clinical outcomes were recorded for up to 3 years. Clinical endpoints were defined according to the definitions of the Valve-Academic-Research-Consortium. RESULTS: One hundred-three patients (age 81 ± 7 years, 63% women) were enrolled. Median European System for Cardiac Operative Risk Evaluation II score was 4.1% (IQR 1.8%-4.2%). Mean aortic valve gradient was 6.9 ± 3.3 mm Hg and 7.7 ± 3.3 mm Hg, and an effective orifice area was 2.1 ± 0.5 cm2 and 2.0 ± 0.5 cm2 at 30 days and 1-year follow-up, respectively. More than mild paravalvular leak was observed in 2.0% of patients at 30 days and 3.3% at 1 year. At 1-year follow-up, 14.7% of patients required implantation of a new permanent pacemaker, 1 patient had endocarditis with an uneventful clinical course and good THV-function after antibiotic therapy, and no thrombosis, structural-valve-detoriation (SVD), or non-SVD had occurred. At 3-year follow-up, rates of all-cause and cardiovascular mortality were 31.4% and 18.8%, respectively. CONCLUSIONS: Transfemoral implantation of the Allegra-THV resulted in favorable clinical and echocardiographic outcomes at up to 3-year follow-up. Head-to-head randomized clinical trials are necessary to determine if the Allegra-THV valve performs as well as current generation valves.


Assuntos
Ecocardiografia , Valvas Cardíacas , Humanos , Animais , Bovinos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Terfenadina , Catéteres
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA