Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(12)2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38931704

RESUMO

We present the design, fabrication, and testing of a low-cost, miniaturized detection system that utilizes chemiluminescence to measure the presence of adenosine triphosphate (ATP), the energy unit in biological systems, in water samples. The ATP-luciferin chemiluminescent solution was faced to a silicon photomultiplier (SiPM) for highly sensitive real-time detection. This system can detect ATP concentrations as low as 0.2 nM, with a sensitivity of 79.5 A/M. Additionally, it offers rapid response times and can measure the characteristic time required for reactant diffusion and mixing within the reaction volume, determined to be 0.3 ± 0.1 s. This corresponds to a diffusion velocity of approximately 44 ± 14 mm2/s.


Assuntos
Trifosfato de Adenosina , Medições Luminescentes , Água , Trifosfato de Adenosina/análise , Água/química , Medições Luminescentes/métodos , Luminescência , Técnicas Biossensoriais/métodos
2.
Sensors (Basel) ; 24(14)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39065899

RESUMO

The progressive increase in nitrate's (NO3-) presence in surface and groundwater enhances environmental and human health risks. The aim of this work is the fabrication and characterization of sensitive, real-time, low-cost, and portable amperometric sensors for low NO3- concentration detection in water. Copper (Cu) micro-flowers were electrodeposited on top of carbon screen-printed electrodes (SPCEs) via cyclic voltammetry (with voltage ranging from -1.0 V to 0.0 V at a scan rate of 0.1 V s-1). The obtained sensors exhibited a high catalytic activity toward the electro-reduction in NO3-, with a sensitivity of 44.71 µA/mM. They had a limit of detection of 0.87 µM and a good dynamic linear concentration range from 0.05 to 3 mM. The results were compared to spectrophotometric analysis. In addition, the devices exhibited good stability and a maximum standard deviation (RSD) of 5% after ten measurements; reproducibility, with a maximum RSD of 4%; and repeatability after 10 measurements with the RSD at only 5.63%.

3.
Molecules ; 29(13)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38998981

RESUMO

Monitoring of ammonium ion levels in water is essential due to its significant impact on environmental and human health. This work aims to fabricate and characterize sensitive, real-time, low-cost, and portable amperometric sensors for low NH4+ concentrations in water. Two strategies were conducted by cyclic voltammetry (CV): electrodeposition of Au nanoparticles on a commercial polyaniline/C electrode (Au/PANI/C), and CV of electropolymerized polyaniline on a commercial carbon electrode (Au/PANIep/C). Au NPs increase the electrical conductivity of PANI and its ability to transfer charges during electrochemical reactions. The electrode performances were tested in a concentration range from 0.35 µM to 7 µM in NH4+ solution. The results show that the Au/PANI/C electrode performs well for high NH4+ concentrations (0.34 µM LoD) and worsens for low NH4+ concentrations (0.01 µM LoD). A reverse performance occurs for the electrode Au/PANIep/C, with a 0.03 µM LoD at low NH4+ concentration and 0.07 µM LoD at high NH4+ concentration. The electrodes exhibit a good reproducibility, with a maximum RSD of 3.68% for Au/PANI/C and 5.94% for Au/PANIep/C. In addition, the results of the repeatability tests show that the electrochemical reaction of sensing is fully reversible, leaving the electrode ready for a new detection event.

4.
Microorganisms ; 10(5)2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35630315

RESUMO

Legionella pneumophila contamination of water systems is a crucial issue for public health. The pathogen is able to persist in water as free-living planktonic bacteria or to grow within biofilms that adhere to and clog filters and pipes in a water system, reducing its lifespan and, in the case of hospital buildings, increasing the risk of nosocomial infections. The implementation of water management is considered to be the main prevention measure and can be achieved from the optimization of water system architecture, notably introducing new materials and strategies to contrast Legionella biofilm proliferation and so prolong the water system functionality. In this research, we propose a new smart surface against L. pneumophila biofilm formation. This is based on an innovative type of coating consisting of a sulfonated pentablock copolymer (s-PBC, commercially named Nexar™) deposited on top of a polypropylene (PP) coupon in a sandwich filter model. The covering of PP with s-PBC results in a more hydrophilic, acid, and negatively charged surface that induces microbial physiological inhibition thereby preventing adhesion and/or proliferation attempts of L. pneumophila prior to the biofilm formation. The antibiofilm property has been investigated by a Zone of Inhibition test and an in vitro biofilm formation analysis. Filtration tests have been performed as representative of possible applications for s-PBC coating. Results are reported and discussed.

5.
Microorganisms ; 9(3)2021 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-33799845

RESUMO

Legionella is able to remain in water as free-living planktonic bacteria or to grow within biofilms that adhere to the pipes. It is also able to enter amoebas or to switch into a viable but not culturable (VBNC) state, which contributes to its resistance to harsh conditions and hinders its detection in water. Factors regulating Legionella growth, such as environmental conditions, type and concentration of available organic and inorganic nutrients, presence of protozoa, spatial location of microorganisms, metal plumbing components, and associated corrosion products are important for Legionella survival and growth. Finally, water treatment and distribution conditions may affect each of these factors. A deeper comprehension of Legionella interactions in water distribution systems with the environmental conditions is needed for better control of the colonization. To this purpose, the implementation of water management plans is the main prevention measure against Legionella. A water management program requires coordination among building managers, health care providers, and Public Health professionals. The review reports a comprehensive view of the state of the art and the promising perspectives of both monitoring and disinfection methods against Legionella in water, focusing on the main current challenges concerning the Public Health sector.

6.
Artigo em Inglês | MEDLINE | ID: mdl-34300030

RESUMO

Conventional high throughput methods assaying the chemical state of water and the risk of heavy metal accumulation share common constraints of long and expensive analytical procedures and dedicated laboratories due to the typical bulky instrumentation. To overcome these limitations, a miniaturized optical system for the detection and quantification of inorganic mercury (Hg2+) in water was developed. Combining the bioactivity of a light-emitting mercury-specific engineered Escherichia coli-used as sensing element-with the optical performance of small size and inexpensive Silicon Photomultiplier (SiPM)-used as detector-the system is able to detect mercury in low volumes of water down to the concentration of 1 µg L-1, which is the tolerance value indicated by the World Health Organization (WHO), providing a highly sensitive and miniaturized tool for in situ water quality analysis.


Assuntos
Mercúrio , Poluentes Químicos da Água , Escherichia coli/genética , Mercúrio/análise , Água , Poluentes Químicos da Água/análise , Qualidade da Água
7.
Materials (Basel) ; 12(21)2019 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-31652698

RESUMO

This paper reports on the electrical activation and Ohmic contact properties on p-type Al-implanted silicon carbide (4H-SiC). In particular, the contacts were formed on 4H-SiC-implanted layers, subjected to three different post-implantation annealing processes, at 1675 °C, 1175 °C, and 1825 °C. Under these post-implantation annealing conditions, the electrical activation of the Al dopant species increased from 39% to 56%. The Ti/Al/Ni contacts showed an Ohmic behavior after annealing at 950 °C. The specific contact resistance ρc could be lowered by a factor of 2.6 with the increase of the post-implantation annealing temperature. The result can be useful for application in device fabrication. Moreover, the dependence of ρc on the active acceptor concentration followed the thermionic field emission model, with a barrier height of 0.63 eV.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA