Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38818846

RESUMO

AIMS: We aimed to assess the acute and midterm efficacy of premature ventricular contraction (PVC) ablation guided by multielectrode and point-by-point (PbP) mapping. METHODS AND RESULTS: This is a retrospective, international multicentre study of consecutive patients referred for PVC ablation in 10 hospital centres from January 2017 to December 2021. Based on the mapping approach, two cohorts were identified: the 'Multipolar group', where a dedicated high-density mapping catheter was employed, and the 'PbP group', where mapping was performed with the ablation catheter. Procedural endpoints, safety, and acute (procedural) and midterm efficacies were assessed. Of the 698 patients included in this study, 592 received activation mapping [46% males, median age of 55 (41-65) years]-248 patients in the Multipolar group and 344 patients in the PbP group. A higher number of activation points [432 (217-843) vs. 95 (42-185), P < 0.001], reduced mapping time (40 ± 38 vs. 61 ± 50 min, P < 0.001), and shorter procedure time (124 ± 60 vs. 143 ± 63 min, P < 0.001) were reported in the Multipolar group. Both groups had high acute success rates (84.7% with Multipolar mapping vs. 81.3% with PbP mapping, P = 0.63), as well as midterm efficacy (83.4% vs. 77.4%, P = 0.08), with no significant differences in the risk of adverse events (6.0% vs. 3.5%, P = 0.24). However, for left-sided PVC ablation specifically, there was a higher midterm efficacy in the Multipolar group (80.7% vs. 69.5%, P = 0.04), with multipolar mapping being an independent predictor of success [adjusted OR = 2.231 (95% CI, 1.476-5.108), P = 0.02]. CONCLUSION: The acute and midterm efficacies of PVC ablation are high with both multipolar and PbP mapping, although the former allows for quicker procedures and may potentially improve the outcomes of left-sided PVC ablation.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Masculino , Pessoa de Meia-Idade , Feminino , Ablação por Cateter/métodos , Estudos Retrospectivos , Idoso , Adulto , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas
2.
J Cardiovasc Electrophysiol ; 34(2): 356-365, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36434798

RESUMO

INTRODUCTION: Critical isthmuses of atypical atrial flutters (AAFLs) are usually located at slow conduction areas that exhibit fractionated electrograms. We tested a novel software, intended for integration with a commercially available navigation system, that automatically detects fractionated electrograms, to identify the critical isthmus in patients with AAFL ablation. METHODS AND RESULTS: All available patients were analyzed; 27 patients with 33 AAFLs were included. The PentaRay NAV catheter (Biosense Webster) was used for mapping. The novel software was retrospectively applied; fractionated points with duration ≥80 ms and bipolar voltage between 0.05 and 0.5 mV were highlighted on the surface of maps. In 10 randomly chosen AAFLs, an expert electrophysiologist evaluated the positive predictive value of the algorithm to detect true fractionation: 74.4%. We tested the capacity of the software to identify areas of fractionation (defined as clusters of ≥3 adjacent points with fractionation) at the critical isthmus of the AAFLs (defined using conventional mapping criteria). An area of fractionation was identified at the critical isthmus in 30 cases (91%). Globally, 144 areas of fractionation (median number per AAFL 4 [3-6]) were identified. Duration of the fractionation or the surface of the areas was not different between areas at critical isthmuses and the rest. Setting the fractionation score filter of the software in nine provided best performance. CONCLUSIONS: The novel software detected areas of fractionation at the critical isthmus in most AAFLs, which may help identify the critical isthmus in clinical practice.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Estudos Retrospectivos , Ablação por Cateter/métodos , Frequência Cardíaca , Valor Preditivo dos Testes
3.
J Cardiovasc Electrophysiol ; 34(2): 389-399, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36335623

RESUMO

INTRODUCTION: Scar-related ventricular tachycardia (VT) usually results from an underlying reentrant circuit facilitated by anatomical and functional barriers. The later are sensitive to the direction of ventricular activation wavefronts. We aim to evaluate the impact of different ventricular activation wavefronts on the functional electrophysiological properties of myocardial tissue. METHODS: Patients with ischemic heart disease referred for VT ablation underwent high-density mapping using Carto®3 (Biosense Webster). Maps were generated during sinus rhythm, right and left ventricular pacing, and analyzed using a new late potential map software, which allows to assess local conduction velocities and facilitates the delineation of intra-scar conduction corridors (ISCC); and for all stable VTs. RESULTS: In 16 patients, 31 high-resolution substrate maps from different ventricular activation wavefronts and 7 VT activation maps were obtained. Local abnormal ventricular activities (LAVAs) were found in VT isthmus, but also in noncritical areas. The VT isthmus was localized in areas of LAVAs overlapping surface between the different activation wavefronts. The deceleration zone location differed depending on activation wavefronts. Sixty-six percent of ISCCs were similarly identified in all activating wavefronts, but the one acting as VT isthmus was simultaneously identified in all activation wavefronts in all cases. CONCLUSION: Functional based substrate mapping may improve the specificity to localize the most arrhythmogenic regions within the scar, making the use of different activation wavefronts unnecessary in most cases.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz/diagnóstico , Cicatriz/etiologia , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
4.
J Cardiovasc Electrophysiol ; 33(6): 1211-1222, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35338745

RESUMO

BACKGROUND: Automated systems for substrate mapping in the context of ventricular tachycardia (VT) ablation may annotate far-field rather than near-field signals, rendering the resulting maps hard to interpret. Additionally, quantitative assessment of local conduction velocity (LCV) remains an unmet need in clinical practice. We evaluate whether a new late potential map (LPM) algorithm can provide an automatic and reliable annotation and localized bipolar voltage measurement of ventricular electrograms (EGMs) and if LCV analysis allows recognizing intrascar conduction corridors acting as VT isthmuses. METHODS: In 16 patients referred for scar-related VT ablation, 8 VT activation maps and 29 high-resolution substrate maps from different activation wavefronts were obtained. In offline analysis, the LPM algorithm was compared to manually annotated substrate maps. Locations of the VT isthmuses were compared with the corresponding substrate maps in regard to LCV. RESULTS: The LPM algorithm had an overall/local abnormal ventricular activity (LAVA) annotation accuracy of 94.5%/81.1%, which compares to 83.7%/23.9% for the previous wavefront algorithm. The resultant maps presented a spatial concordance of 88.1% in delineating regions displaying LAVA. LAVA median localized bipolar voltage was 0.22 mV, but voltage amplitude assessment had modest accuracy in distinguishing LAVA from other abnormal EGMs (area under the curve: 0.676; p < .001). LCV analysis in high-density substrate maps identified a median of two intrascar conduction corridors per patient (interquartile range: 2-3), including the one acting as VT isthmus in all cases. CONCLUSION: The new LPM algorithm and LCV analysis may enhance substrate characterization in scar-related VT.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Algoritmos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cicatriz/diagnóstico , Cicatriz/etiologia , Frequência Cardíaca , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
5.
Pacing Clin Electrophysiol ; 44(10): 1701-1710, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34409630

RESUMO

BACKGROUND: Cavotricuspid isthmus (CTI) ablation in typical atrial flutter (AFL) restores sinus rhythm in 95% of patients, which may lead to the discontinuation of oral anticoagulation during follow-up. Therefore, we aimed to systematically review the clinical impact of oral anticoagulation in the incidence of thromboembolic events (TE) after typical AFL ablation. METHODS: We searched for controlled studies evaluating the impact of anticoagulation in the incidence of TE in patients submitted to AFL ablation in MEDLINE, CENTRAL, PsycINFO database (June/2021). The primary outcome was TE events (ischemic stroke or systemic embolism). A meta-analysis was performed deriving risk ratios (RR) and 95% confidence intervals (CI). Statistical heterogeneity was measured through I2 metric. The confidence in the evidence was appraised with Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. RESULTS: Eight observational studies with 4870 patients were included. TE events were not significantly reduced (RR 1.18, 95% CI 0.59-2.36; n = 4870; GRADE very low). A meta-regression showed that for each 10% increase in the prevalence of previous AF in the studied population, anticoagulation reduced TE risk in 32%. There were no significant differences regarding bleeding events (RR 2.16, 95% CI 0.43-10.97, I2  = 0%; GRADE low), but there was a lower all-cause mortality (RR 0.24, 95% CI 0.17-0.32, GRADE low). CONCLUSION: The best available evidence lacks robustness and the data did not definitely associate anticoagulation after typical AFL ablation with reduced TE.


Assuntos
Anticoagulantes/administração & dosagem , Flutter Atrial/cirurgia , Ablação por Cateter , Complicações Pós-Operatórias/prevenção & controle , Tromboembolia/prevenção & controle , Administração Oral , Humanos
6.
Europace ; 20(6): 986-992, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28430960

RESUMO

Aims: Cardiac Resynchronization Therapy (CRT) is associated with a particularly high non-response rate in patients with atrial fibrillation (AF). We aimed to assess the effectiveness of triple-site (Tri-V) pacing CRT in this population. Methods and results: Prospective observational study of patients with permanent AF who underwent CRT implantation with an additional right ventricle lead in the outflow tract septal wall. After implantation, programming mode (Tri-V or biventricular pacing) was selected based on cardiac output determination. Patients were classified as responders if NYHA class was reduced by at least one level and echocardiographic ejection fraction (EF) increased ≥ 10%, and as super-responders if in NYHA class I and EF ≥ 50%. Forty patients (93% male, mean age 72 ± 10 years) were included. Thirty-three were programmed in Tri-V. The following results pertain to this subgroup. At baseline, 58% were in NYHA class III and 36% NYHA class II. At 1 year follow-up, Minnesota QoL score was reduced (36 ± 23 vs. 8 ± 6; P = 0.001) and the 6MWT distance improved (384 ± 120 m to 462 ± 87 m, P = 0.003). Mean EF increased (26% ± 8 vs. 39 ± 10; P < 0.001 at 6 months and 41 ± 10; P < 0.001 at 12 months). Responder rate was 59% at 6 months and 79% at 12 months. Super-responder rate was 9% at 6 months and 16% at 12 months. One year survival free from heart failure hospitalization was 87.9%. Conclusion: Tri-V CRT yielded higher response and super-response rates than usually reported for CRT in patients with permanent AF using clinical and remodeling criteria.


Assuntos
Fibrilação Atrial , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Ecocardiografia/métodos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Portugal , Ajuste de Prótese/métodos , Risco Ajustado/métodos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento
7.
Acta Pharmacol Sin ; 39(7): 1085-1099, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29877319

RESUMO

Pervasive transcription of the human genome is responsible for the production of a myriad of non-coding RNA molecules (ncRNAs) some of them with regulatory functions. The pivotal role of ncRNAs in cardiovascular biology has been unveiled in the last decade, starting from the characterization of the involvement of micro-RNAs in cardiovascular development and function, and followed by the use of circulating ncRNAs as biomarkers of cardiovascular diseases. The human non-coding secretome is composed by several RNA species that circulate in body fluids and could be used as biomarkers for diagnosis and outcome prediction. In cardiovascular diseases, secreted ncRNAs have been described as biomarkers of several conditions including myocardial infarction, cardiac failure, and atrial fibrillation. Among circulating ncRNAs, micro-RNAs (miRNAs), long noncoding RNAs (lncRNAs) and circular RNAs (circRNAs) have been proposed as biomarkers in different cardiovascular diseases. In comparison with standard biomarkers, the biochemical nature of ncRNAs offers better stability and flexible storage conditions of the samples, and increased sensitivity and specificity. In this review we describe the current trends and future prospects of the use of the ncRNA secretome components as biomarkers of cardiovascular diseases, including the opening questions related with their secretion mechanisms and regulatory actions.


Assuntos
Doenças Cardiovasculares/sangue , MicroRNAs/sangue , RNA Longo não Codificante/sangue , RNA/sangue , Biomarcadores/sangue , Doenças Cardiovasculares/genética , Humanos , MicroRNAs/genética , RNA/genética , RNA Circular , RNA Longo não Codificante/genética
8.
J Cardiovasc Electrophysiol ; 28(11): 1285-1294, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28776822

RESUMO

BACKGROUND: Ripple mapping (RM) displays electrograms as moving bars over a three-dimensional surface displaying bipolar voltage, and has shown in a single-center series to be effective for atrial tachycardia (AT) mapping without annotation of local activation time or window-of-interest assignment. We tested the reproducibility of these findings in operators naïve to RM, using it for the first time in postablation AT. METHODS: Maps were collected with multielectrode catheters and CARTO ConfiDENSE. A diagnosis of the tachycardia mechanism was made using RM and an assessment of operator confidence was made according to a three-grade scale (1 highest-3 lowest). RESULTS: The first 20 patients (64 ± 9 years, median two previous ablations) undergoing RM-guided AT ablation across five sites were studied. High-density maps (2,935 ± 1,328 points) in AT (CL = 296 ± 95 milliseconds) were collected. Macroreentrant ATs bordered by scar or anatomical obstacles were identified in n = 12 (60%), small reentrant ATs around scar in n = 3 (15%), and focal ATs from scar in n = 5 (25%). Diagnostic confidence with RM was grade 1 in n = 13 (65%), where operators felt confident to proceed to ablation without entrainment. Ablation offered the correct diagnosis n = 18 (90%). Retrospective review of the accompanying LAT maps demonstrated potential sources for error related to the window of interest selection, interpolation, and differentiating regions of scar during tachycardia on the voltage map. CONCLUSION: RM was easy to adopt by operators using it for the first time, and identified the correct target for ablation with high diagnostic confidence in most cases of complex AT.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/métodos , Imageamento Tridimensional/métodos , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/fisiopatologia , Adulto , Idoso , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Supraventricular/cirurgia
9.
Circ J ; 80(10): 2183-91, 2016 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-27593229

RESUMO

BACKGROUND: MicroRNAs (miRNAs) are key players in cardiovascular development and disease. However, not only miRNAs of a cardiac origin have a critical role in heart function. Recent studies have demonstrated that miR-122-5p, a hepatic miRNA, increases in the bloodstream during ischemic cardiogenic shock and it is upregulated in the infarcted myocardium. The aim of the present study was to determine the potential of circulating miR-122-5p as a biomarker for early prognostic stratification of ST-segment elevation acute myocardial infarction (STEMI) patients. METHODS AND RESULTS: One hundred and forty-two consecutive STEMI patients treated with primary angioplasty were included in the study. Serum levels of miR-1-3p, -122-5p, -133a-3p, -133b, -208b-3p and -499a-5p were measured at the time of cardiac catheterization by quantitative polymerase chain reaction and related to in-hospital and long-term outcome. During a follow up of 20.8 months, 9 patients died, 6 had recurrence of myocardial infarction, and 26 patients suffered an adverse cardiovascular event. Event-free survival was significantly worse in patients with a higher miR-122-5p/133b ratio (3rd tertile distribution, above 1.42 Log(10)), having almost a 9-fold higher risk of death or myocardial infarction and a 4-fold higher risk of adverse cardiovascular events. CONCLUSIONS: This study showed that the miR-122-5p/133b ratio is a new prognostic biomarker for the early identification of STEMI patients at a higher risk of developing major adverse events after undergoing primary percutaneous coronary intervention. (Circ J 2016; 80: 2183-2191).


Assuntos
MicroRNAs/sangue , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/sangue , Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Prognóstico , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/sangue , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia
10.
Amyloid ; 31(1): 32-41, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37493395

RESUMO

BACKGROUND: Early diagnosis and prognostic stratification of cardiac transthyretin amyloidosis are crucial. Although 99mTc 3,3-diphosphono-1,2-propanedicarboxylic acid (DPD) scintigraphy is the preferred method for the non-invasive diagnosis, its accuracy appears to be limited in transthyretin amyloidosis protein (ATTR) V30M mutation. Furthermore, its prognostic value in this mutation is unknown. This study investigated the diagnostic value of DPD scintigraphy to detect ATTR cardiomyopathy in V30M mutation and explored its prognostic value regarding mortality. METHODS: A total of 288 ATTR V30M mutation carriers (median age: 46 years; 49% males) without myocardial thickening (defined as septal thickness ≥13mm) attributable to other causes and who underwent DPD scintigraphy were enrolled. ATTR cardiomyopathy was defined by septal thickness ≥13mm and at least one of the criteria: late heart-to-mediastinum (H/M) 123I-metaiodobenzylguanidine (MIBG) uptake ratio <1.60; electrical heart disease or biopsy-documented amyloidosis. RESULTS: ATTR cardiomyopathy was identified in 41 (14.2%) patients and cardiac DPD uptake in 34 (11.8%). During a mean follow-up of 33.6 ± 1.2 months, 16 patients died (5.6%). Mortality was 14 times higher in patients with ATTR cardiomyopathy, 13 times higher in those with DPD uptake and 10 times higher in those with late H/M MIBG <1.60. The combined assessment of septal thickness and cardiac DPD uptake improved risk stratification: patients without septal thickening and without DPD retention had an excellent prognosis while those who presented either or both of them had a significantly worse prognosis, with 5-year mortality rates ranging from 39.9 to 53.3%. CONCLUSIONS: DPD scintigraphy is useful for prognostic stratification of ATTR V30M mutation carriers. Patients without septal thickening and no DPD uptake present the best prognosis compared to those with any signs of cardiac involvement.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Prognóstico , 3-Iodobenzilguanidina , Pré-Albumina/genética , Neuropatias Amiloides Familiares/diagnóstico por imagem , Neuropatias Amiloides Familiares/genética , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/genética , Cintilografia
11.
Heart Rhythm ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38848856

RESUMO

BACKGROUND: Recurrent ventricular tachycardia (VT) can be treated by substrate modification of the myocardial scar by catheter ablation during sinus rhythm without VT induction. Better defining this arrhythmic substrate could help improve outcome and reduce ablation burden. OBJECTIVE: The study aimed to limit ablation within postinfarction scar to conduction channels within the scar to reduce VT recurrence. METHODS: Patients undergoing catheter ablation for recurrent implantable cardioverter-defibrillator therapy for postinfarction VT were recruited at 5 centers. Left ventricular maps were collected on CARTO using a Pentaray catheter. Ripple mapping was used to categorize infarct scar potentials (SPs) by timing. Earliest SPs were ablated sequentially until there was loss of the terminal SPs without their direct ablation. The primary outcome measure was sustained VT episodes as documented by device interrogations at 1 year, which was compared with VT episodes in the year before ablation. RESULTS: The study recruited 50 patients (mean left ventricular ejection fraction, 33% ± 9%), and 37 patients (74%) met the channel ablation end point with successful loss of latest SPs without direct ablation. There were 16 recurrences during 1-year follow-up. There was a 90% reduction in VT burden from 30.2 ± 53.9 to 3.1 ± 7.5 (P < .01) per patient, with a concomitant 88% reduction in appropriate shocks from 2.1 ± 2.7 to 0.2 ± 0.9 (P < .01). There were 8 deaths during follow-up. Those who met the channel ablation end point had no significant difference in mortality, recurrence, or VT burden but had a significantly lower ablation burden of 25.7 ± 4.2 minutes vs 39.9 ± 6.1 minutes (P = .001). CONCLUSION: Scar channel ablation is feasible by ripple mapping and can be an alternative to more extensive substrate modification techniques.

13.
Cardiovasc Pathol ; 65: 107541, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37127060

RESUMO

AIMS: Myocardial fibrosis (MF) is a common pathological process in a wide range of cardiovascular diseases. Its quantity has diagnostic and prognostic relevance. We aimed to assess if the complementary use of an automated artificial intelligence software might improve the precision of the pathologist´s quantification of MF on endomyocardial biopsies (EMB). METHODS AND RESULTS: Intraoperative EMB samples from 30 patients with severe aortic stenosis submitted to surgical aortic valve replacement were analysed. Tissue sections were stained with Masson´s trichrome for collagen/fibrosis and whole slide images (WSI) from the experimental glass slides were obtained at a resolution of 0.5 µm using a digital microscopic scanner. Three experienced pathologists made a first quantification of MF excluding the subendocardium. After two weeks, an algorithm for Masson´s trichrome brightfield WSI (at QuPath software) was applied and the automatic quantification was revealed to the pathologists, who were asked to reassess MF, blinded to their first evaluation. The impact of the automatic algorithm on the inter-observer agreement was evaluated using Bland-Altman type methodology. Median values of MF on EMB were 8.33% [IQR 5.00-12.08%] and 13.60% [IQR 7.32-21.2%], respectively for the first pathologist´s and automatic algorithm quantification, being highly correlated (R2: 0.79; p < 0.001). Interobserver discordance was relevant, particularly for higher percentages of MF. The knowledge of the automatic quantification significantly improved the overall pathologist´s agreement, which became unaffected by the degree of MF severity. CONCLUSIONS: The use of an automated artificial intelligence software for MF quantification on EMB samples improves the reproducibility of measurements by experienced pathologists. By improving the reliability of the quantification of myocardial tissue components, this adjunctive tool may facilitate the implementation of imaging-pathology correlation studies.


Assuntos
Inteligência Artificial , Patologistas , Humanos , Reprodutibilidade dos Testes , Miocárdio/patologia , Fibrose
14.
Rev Port Cardiol ; 42(4): 385-389, 2023 04.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36893834

RESUMO

Ablation of atypical left atrial flutters (LAF) is very challenging due to the complexity of the underlying atrial substrate and diverse arrhythmia mechanisms. The interpretation of the arrhythmia mechanism is usually difficult, even using advanced three-dimensional (3D) mapping systems. SparkleMap is a novel mapping algorithm that displays each electrogram as a green dot that lights up at the point corresponding to the local activation time, superimposed either on the substrate or the local activation time 3D-maps. It is not affected by the setting of the "window of interest" and there is no need for user post-processing. We present the case of patient with a persistent atypical LAF in whom we tested the concept of complex arrhythmia interpretation exclusively based on the analysis of the substrate and evaluation of SparkleMap-derived wavefront propagation. We describe the workflow for map collection and the systematic approach for arrhythmia interpretation that resulted in the identification of a dual loop perimitral mechanism with a common slow conducting isthmus inside a scar at the septum/anterior atrial wall. This new method of analysis enabled the use of a specifically targeted and precise approach for ablation, with restoration of sinus rhythm within five seconds of radiofrequency application. After 18 months of follow-up, the patient remains free from recurrences, without anti-arrhythmic medication. This case report exemplifies how helpful new mapping algorithms can be in the interpretation of the arrhythmia mechanism in patients with complex LAF. It also suggests an innovative workflow to integrate the SparkleMap into the mapping approach.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Humanos , Flutter Atrial/cirurgia , Flutter Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Apêndice Atrial/cirurgia , Resultado do Tratamento
15.
Int J Cardiol ; 383: 33-39, 2023 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-37116756

RESUMO

PURPOSE: We aim to evaluate whether the use of a multielectrode mapping catheter could lead to higher efficacy of premature ventricular contraction (PVC) ablation. METHODS: Prospective, multicenter nonrandomized study of consecutive patients referred for PVC ablation from January 2018 to June 2021. Patients were separated into two groups: activation map performed with the PentaRay catheter (Study group) or with the ablation catheter (Control group). PMF software was used in both groups. Procedural endpoints and 1-year freedom from ventricular arrhythmia were assessed. RESULTS: During the enrollment period 136 patients (60% males, mean age of 55 ± 17 years, 60% left-sided origin) fulfilled the inclusion criteria - 68 patients in each group. Patients in the Study Group had a sevenfold higher number of acquired activation points (768 ± 728 vs. 110 ± 79, p < 0.01), a shorter mapping time (28 ± 19 min vs. 49 ± 32 min, p < 0.01) and a quicker procedure time (110 ± 33 min vs. 134 ± 50 min, p < 0.01), compared to patients in the Control Group. While there were no significant differences in the acute success (95.6% in the Study Group vs. 90.1% in Control group, p = 0.49), or adverse events (4% in the Study group vs. 7% in the Control group, p = 0.72), patients in the Study group had a higher freedom from ventricular arrhythmia at 1-year (89.7% vs. 70.6%, p = 0.01). The use of the PentaRay catheter was an independent predictor of success (HR = 6.20 [95% CI, 1.08-35.47], p = 0.003). CONCLUSIONS: The use of the PentaRay catheter may improve the outcome of PVC ablation while reducing procedure time.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Estudos Prospectivos , Catéteres , Software , Fatores de Tempo , Ablação por Cateter/métodos , Resultado do Tratamento
16.
Artigo em Inglês | MEDLINE | ID: mdl-37966657

RESUMO

BACKGROUND: Brugada syndrome (BrS) is associated with abnormal electrophysiological properties at right ventricular epicardium, consisting of fragmented electrograms extending well beyond QRS termination. We aimed to evaluate the utility of signal-averaged electrocardiogram (SA-ECG) for the noninvasive assessment of late potentials (LP) and risk stratification of BrS patients. METHODS: A prospective, observational, single-center study of BrS patients is submitted to SA-ECG with the determination of the total filtered QRS duration (fQRS), root mean square voltage of the 40 ms terminal portion of the QRS (RMS40), and duration of the low-amplitude electric potential component of the terminal portion of the QRS (LAS40). LP were considered positive when above standard cut-offs: fQRS > 114 ms, RMS40 < 20 µV, and LAS40 > 38 ms. The rates of malignant arrhythmic events (MAEs), defined as sudden death or appropriate shocks, were compared in relation to clinical characteristics and SA-ECG findings. RESULTS: A total of 106 BrS patients (mean age, 48 ± 12 years, 67.9% male) were studied, 49% with type-1 spontaneous pattern and 81% asymptomatic. During a median follow up of 4.7 years, 10 patients (7.1%) suffered MAEs, including 4 sudden deaths. The presence of LP was significantly associated with the arrhythmic risk, which increased with the number of altered LP criteria. In comparison to the patients who had none or 1 altered LP criterium, MAE risk was 4.7 times higher in those with 2 altered criteria and 9.4 times higher in those with 3 altered LP criteria. CONCLUSIONS: SA-ECG may be a useful tool for risk stratification in BrS. The presence of 2 or 3 abnormal LP criteria could identify a subset of asymptomatic patients at high risk of arrhythmic events.

18.
Rev Port Cardiol ; 41(4): 325-335, 2022 Apr.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36062666

RESUMO

INTRODUCTION AND OBJECTIVE: Radiofrequency catheter ablation (RCA) for ventricular tachycardia (VT) in patients with ischemic heart disease (IHD) is associated with a reduced risk of VT storm and implantable cardioverter defibrillator (ICD) shocks. We aim to report the outcome after a single RCA procedure for VT in patients with IHD using a high-density substrate-based approach. METHODS: We conducted a prospective, observational, single-center and single-arm study involving patients with IHD, referred for RCA procedure for VT using high-density mapping catheters. Substrate mapping was performed in all patients. Procedural endpoints were VT non-inducibility and local abnormal ventricular activities (LAVAs) elimination. The primary end point was survival free from appropriate ICD shocks and secondary end points included VT storm and all-cause mortality. RESULTS: Sixty-four consecutive patients were included (68±9 years, 95% male, mean ejection fraction 33±11%, 39% VT storms, and 69% appropriate ICD shocks). LAVAs were identified in all patients and VT inducibility was found in 83%. LAVA elimination and non-inducibility were achieved in 93.8% and 60%, respectively. After a mean follow-up of 25±18 months, 90% and 85% of patients are free from appropriate ICD shocks at one and two years, respectively. The proportion of patients experiencing VT storm decreased from 39% to 1.6%. Overall survival was 89% and 84% at one and two years, respectively. CONCLUSIONS: RCA of VT in IHD using a high-density mapping substrate-based approach resulted in a steady freedom of ICD shocks and VT storm.

19.
Rev Port Cardiol ; 30(2): 139-69, 2011 Feb.
Artigo em Inglês, Português | MEDLINE | ID: mdl-21553609

RESUMO

OBJECTIVES: To compare definitions of metabolic syndrome (MS) in relation to their association with coronary artery disease (CAD) and stroke. METHODS: We performed a cross-sectional study in a primary care setting, involving 719 general practitioners and based on stratified distribution proportional to the population density. The first two adult patients scheduled for an appointment on a given day were invited to participate, irrespective of the reason for the consultation. A questionnaire was applied to record sociodemographic, clinical and laboratory data. A diagnosis of MS was defined according to NCEP-ATP III 2001, NCEP-ATP III 2004, IDF and AHA/NHLBI criteria. Multivariate logistic regression analysis was used to assess the risk of CAD and stroke according to gender, age, body mass index, waist circumference, HDL cholesterol, triglycerides, hypertension, diabetes and MS according to each definition. RESULTS: The study included 16,856 individuals (age 58.1 +/- 15.1 years). The prevalence of MS adjusted for gender, age and region size according to the 2001 and 2004 NCEP-ATP III, IDF and AHA/NHLBI definitions was 28.4%, 32.8%, 65.5% and 69.4%, respectively. The degree of agreement according to k statistics was modest and only 60.3% simultaneously fulfilled the criteria of all definitions. Hypertension was the treatable risk factor most strongly associated with CAD and stroke. Only the IDF and AHA/NHLBI definitions of MS were independently associated with CAD (OR: 1.74 and 2.26, respectively). Regarding stroke, only the AHA/NHLBI criteria showed a statistically significant association (OR: 1.85). CONCLUSIONS: MS as defined according to the AHA/NHLBI criteria appears to be the best predictor of CAD and stroke in the Portuguese population, and remains an independent risk factor for CAD and stroke after adjustment for its individual components.


Assuntos
Síndrome Metabólica/diagnóstico , Síndrome Metabólica/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/etiologia , Estudos Transversais , Feminino , Medicina Geral/estatística & dados numéricos , Humanos , Masculino , Síndrome Metabólica/complicações , Pessoa de Meia-Idade , Portugal/epidemiologia , Análise de Regressão , Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Adulto Jovem
20.
Rev Port Cardiol (Engl Ed) ; 40(2): 119-129, 2021 Feb.
Artigo em Inglês, Português | MEDLINE | ID: mdl-33608198

RESUMO

INTRODUCTION: The authors present the results of the national cardiac electrophysiology registry of the Portuguese Association of Arrhythmology, Pacing and Electrophysiology (APAPE) and the Portuguese Institute of Cardiac Rhythm (IPRC) for 2017 and 2018. METHODS: The registry is annual, voluntary, and observational. Data are collected retrospectively. Developments over the years and their implications are analyzed and discussed. RESULTS: In the 22 electrophysiology centers, 3407 ablations were performed in 2017 and 3653 ablations in 2018. Atrial fibrillation (AF) ablation was the most frequently performed procedure: 1017 ablations in 2017 and 1222 procedures in 2018. Of the patients undergoing AF ablation, 63% were male, 60% were between 50 and 69 years old and 74% had paroxysmal AF. Clinically relevant complications were reported in 0.8% of the procedures. In 2017, 216 ventricular tachycardia (VT) ablation procedures were performed in 15 centers. In 2018, 19 centers performed 249 VT ablations. About 45% of VT ablations were performed in patients with structural heart disease. Complications were reported in 3.2% of the procedures, including one death (0.2%). CONCLUSIONS: The national electrophysiology registry showed a sustained increase in the number of catheter ablations. In addition, procedural complexity increased and AF ablation assumed a dominant position among the procedures performed.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Portugal/epidemiologia , Sistema de Registros , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA