Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Emerg Infect Dis ; 28(6): 1198-1210, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35608626

RESUMO

Knowledge of contemporary genetic composition of dengue virus (DENV) in Africa is lacking. By using next-generation sequencing of samples from the 2017 DENV outbreak in Burkina Faso, we isolated 29 DENV genomes (5 serotype 1, 16 serotype 2 [DENV-2], and 8 serotype 3). Phylogenetic analysis demonstrated the endemic nature of DENV-2 in Burkina Faso. We noted discordant diagnostic results, probably related to genetic divergence between these genomes and the Trioplex PCR. Forward and reverse1 primers had a single mismatch when mapped to the DENV-2 genomes, probably explaining the insensitivity of the molecular test. Although we observed considerable homogeneity between the Dengvaxia and TetraVax-DV-TV003 vaccine strains as well as B cell epitopes compared with these genomes, we noted unique divergence. Continual surveillance of dengue virus in Africa is needed to clarify the ongoing novel evolutionary dynamics of circulating virus populations and support the development of effective diagnostic, therapeutic, and preventive countermeasures.


Assuntos
Vírus da Dengue , Dengue , Burkina Faso/epidemiologia , Dengue/epidemiologia , Surtos de Doenças , Genômica , Humanos , Filogenia , Estudos Retrospectivos , Sorogrupo
2.
Access Microbiol ; 2(8): acmi000138, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32974600

RESUMO

BACKGROUND: Several studies have compared the use of dried blot spot (DBS) as an alternative to plasma specimens, mainly using Whatman 903 cards as filter paper. The aim of this study was to evaluate the use of Whatman FTA card (FTA card) specimens for HIV-1 viral load testing compared to plasma specimens using two real-time PCR assays manufactured by Roche and Abbott. METHODOLOGY: A cross-sectional study was conducted between April 2017 and September 2017 on HIV-1 patients admitted to Yalgado Ouédraogo Teaching Hospital. Paired FTA cards and plasma specimens were collected and analysed using the Abbott Real-Time HIV-1 assay (Abbott) and COBAS AmpliPrep/COBAS TaqMan v2.0 (Roche). RESULTS: In total, 107 patients were included. No statistical differences (P>0.05) were observed between the mean viral loads obtained from the FTA cards and those of the plasma specimens using the Roche and Abbott assays. In total, 29 samples with Roche and 15 samples with Abbott assay showed discrepant results. At viral loads of ≤1000 copies ml-1, the sensitivity and specificity of the FTA cards were 78.6 and 100% with Roche, and 92.3 and 95.9% with Abbott, respectively. Both the Roche and Abbott assays showed good correlation and agreement between the FTA cards and plasma values. CONCLUSION: Our study demonstrates the feasibility of using FTA card filter paper for HIV-1 viral load testing. However, further studies will be required for the validation of the use of FTA card filter paper in HIV-1 treatment monitoring.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA