Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur J Appl Physiol ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695912

RESUMO

PURPOSE: We compared the effects of low-volume combined aerobic and resistance high-intensity interval training (C-HIIT), combined moderate-intensity continuous training (C-MICT) and waitlist control (CON) on vascular health after 8-weeks of supervised training, and an additional 10-months of self-directed training, in adults with type 2 diabetes (T2D). METHODS: Sixty-nine low active adults with T2D were randomised to 8-weeks of supervised C-HIIT (3 times/week, 78-min/week), C-MICT (current exercise guidelines, 4 times/week, 210-min/week) or CON. CON underwent usual care for 8-weeks before being re-randomised to C-HIIT or C-MICT. This was followed by 10-months of self-directed training for participants in C-HIIT and C-MICT. Vascular outcomes were evaluated at baseline, 8-weeks, and 12-months. RESULTS: After 8-weeks, supervised C-HIIT significantly improved relative flow-mediated dilation (FMD) compared with CON (mean difference [MD] 0.8% [0.1, 1.4], p = 0.025). Although not significantly different from CON, the magnitude of change in relative FMD following 8-weeks of supervised C-MICT was similar (MD 0.8% [-0.1, 1.7], p = 0.080). There were no differences in haemodynamic indices, carotid-femoral pulse wave velocity (cfPWV), or aortic reservoir pressure between groups at 8-weeks. After 12-months, there was a significant reduction in haemodynamic indices (time effect, p < 0.05) for both C-HIIT and C-MICT, with no between-group difference. The reduction in cfPWV over 12-months was significantly greater in C-MICT than C-HIIT (group × time effect, p = 0.018). There was no difference in FMD over time or between groups at 12-months. CONCLUSIONS: Short-term supervised C-HIIT and C-MICT both increased brachial artery FMD compared with CON. Long-term C-HIIT and C-MICT were beneficial for improving haemodynamic indices, but not brachial artery FMD. C-MICT was superior to C-HIIT for improving cfPWV at 12-months. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry Identifier ACTRN12615000475549.

2.
Heart Lung Circ ; 33(3): 324-331, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38184427

RESUMO

BACKGROUND: The Navitor (Abbott Inc, IL, USA) transcatheter heart valve is a novel third-generation self-expanding bioprosthesis with specific features to mitigate paravalvular regurgitation (PVR). Owing to its novelty, there is a paucity of data on its application in clinical practice. METHODS: Consecutive cohort analysis of the use of the Navitor system in an as-treated clinical setting at a quaternary heart hospital. RESULTS: Sixty consecutive non-clinical trial patients treated with Navitor were identified. All patients underwent a successful procedure. The mean age was 79.3 years (±SD 7.82), 56.67% (n=34) were female, and the mean STS score was 4.87 (±SD 5.70). At 30 days post-procedure, all patients were alive with no readmissions for heart failure. One patient had a major vascular complication (1.7%). Four patients (7.14% of patients without a pre-existing pacemaker) received a new permanent pacemaker. Two patients (3.4%) had a non-disabling stroke. PVR at 30 days was trivial or none in 75% of patients, and no patient had worse than mild PVR. CONCLUSIONS: The Navitor system in this as-treated cohort was associated with favourable clinical, haemodynamic, and safety outcomes.


Assuntos
Valvopatia Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Valvopatia Aórtica/etiologia , Desenho de Prótese , Fatores de Risco
3.
Heart Lung Circ ; 32(2): 224-231, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36344392

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established therapy for the treatment of aortic valve disease in appropriately selected patients. Previous studies using the self-expanding Portico transcatheter heart valve (THV), (Abbott Structural Heart, St Paul, MN, USA) have demonstrated the technical feasibility of this system albeit in the hands of relatively inexperienced Portico users. The objective of this study was to assess the real-world safety and efficacy of the Portico THV (with and without the FlexNav delivery system, Abbott Structural Heart) at the 30-day timepoint in an Australian cohort. METHODS AND RESULTS: This study was a retrospective real-world cohort analysis of 269 consecutive patients with severe aortic valve disease who underwent TAVI at multiple centres within Australia between February 2015 and April 2021. Of the 269 patients, 51.7% were female, mean Society of Thoracic Surgeons (STS) score was 5.2 (±6.8) and 98.5% had successful implantations. Thirty (30)-day post-implantation all-cause mortality was observed in one (0.4%) patient, major vascular complications in two (0.7%) patients, more-than-mild paravalvular leak in six (2.2%) patients and requirement for new permanent pacemaker implantation in 27 (10.2%) patients. Haemodynamic parameters at 30 days included mean effective orifice area (EOA) of 2.3 (±0.9) cm2 and mean aortic valve gradient (AVG) of 9.6 (±6.2) mmHg. CONCLUSION: This analysis of the Portico THV in a real-world setting suggested that the system is associated with satisfactory safety and efficacy parameters. Previously published datasets may not have found similar findings owing to lower operator experience with the Portico THV system.


Assuntos
Valvopatia Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Austrália/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Valvopatia Aórtica/cirurgia , Desenho de Prótese
4.
Catheter Cardiovasc Interv ; 98(3): E471-E474, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33547708

RESUMO

Patients with a true porcelain aorta and a failed mechanical aortic valve prosthesis have limited treatment options. Using a hybrid of an open trans-ventricular approach with peripheral cardiopulmonary bypass and integration of transcatheter techniques this challenge can be overcome. Trans-ventricular mechanical valve extraction (with transcatheter endovascular occlusion and cardioplegia) followed by direct ante-grade transcatheter heart valve implantation offers a potential solution to this conundrum. The procedure described is a novel technique that allows for the effective treatment of patients with failed mechanical surgical aortic valve prostheses in the setting of an inoperable porcelain aorta. In addition, a collaborative integrated multi-disciplinary heart team environment is required for the management of these complex patients.


Assuntos
Estenose da Valva Aórtica , Grafite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Porcelana Dentária , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Heart Lung Circ ; 21(3): 174-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22071200

RESUMO

Percutaneous intervention is becoming an increasingly recognised modality for the management of prosthetic paravalvar leaks (PVLs) with particular utility in severely symptomatic non-surgical candidates. To date, application of this intervention has predominantly involved closure of mitral valve PVLs. Consequently, current literature on its application to aortic PVLs is limited. This article describes what we believe to be the first percutaneous closure of an aortic prosthetic PVL in Australia.


Assuntos
Angioplastia/instrumentação , Insuficiência da Valva Aórtica/terapia , Valva Aórtica/patologia , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso de 80 Anos ou mais , Angioplastia/métodos , Animais , Aorta/patologia , Aorta/cirurgia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Austrália , Angiografia Coronária , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Falha de Prótese , Suínos
6.
Clin Obes ; 12(3): e12519, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35293141

RESUMO

People with type 2 diabetes (T2D) are at a greater risk of cardiovascular disease than the general population. Both non-modifiable (age) and modifiable (low aerobic fitness, high body fatness) factors are separately predictive of cardiovascular risk, although they often occur concomitantly. This study aimed to examine the (1) association between age and arterial stiffness, a subclinical marker of cardiovascular risk; and (2) effects of body fatness and aerobic fitness on age-related increases in arterial stiffness in people with T2D. Data from 64 individuals with T2D (age 59.8 ± 8.7 years, 40% female, HbA1c 8.4 ± 1.6%) were included in this cross-sectional analysis. Carotid-femoral pulse wave velocity (cfPWV) was used to quantify arterial stiffness. Aerobic fitness (relative V̇O2peak ) was determined via indirect calorimetry during maximal exercise testing. Central body fatness was determined using waist circumference. Data were analysed using hierarchical multiple regressions. After adjustment for sex and duration of T2D, each one standard deviation (SD) increase in age (8.68 years) was associated with a 0.63 m·s-1 increase in cfPWV (ß = 0.416, p = 0.001). Following adjustment for aerobic fitness and body fatness, the standardized ß was unchanged (0.417). A one SD increase in waist circumference (13.9 cm) and relative V̇O2peak (5.3 ml·kg-1 ·min-1 ) were associated with a similar magnitude of difference in cfPWV (0.47 m·s-1 and -0.44 m·s-1 , respectively). Therefore, age is a significant correlate of increased arterial stiffness in T2D, with higher aerobic fitness attenuating, and higher body fatness exacerbating, this increase. Interventions aimed at improving cardiovascular outcomes in people with T2D should target both increased aerobic fitness and reduced body fatness.


Assuntos
Diabetes Mellitus Tipo 2 , Rigidez Vascular , Idoso , Criança , Estudos Transversais , Diabetes Mellitus Tipo 2/epidemiologia , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Onda de Pulso , Fatores de Risco
7.
Int J Cardiol Heart Vasc ; 30: 100643, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33015315

RESUMO

BACKGROUND: The present study is a prospective observational single arm clinical investigation, with parallel bench test interrogation, aimed at investigating the technical feasibility, safety and clinical outcomes with the cone flare crush modified-T (CFCT) bifurcation stenting technique. Bifurcation percutaneous coronary intervention (PCI) remains an area of ongoing procedural evolution. More widely applicable and reproducible techniques are required. METHODS: From April 2018 until March 2019, 20 consecutive patients underwent bifurcation PCI using the CFCT technique with a Pt-Cr everolimus drug-eluting stent with a bioresorbable polymer. Exercise stress echocardiography was performed at 12-month follow-up. The primary outcome was a composite of cardiac related mortality, myocardial infarction, target lesion/vessel revascularization and stroke. Safety secondary endpoints included bleeding, all-cause mortality and stent thrombosis. RESULTS: All patients underwent a successful CFCT bifurcation procedure with no complications to 30-day follow-up. One patient met the primary endpoint requiring target lesion revascularization at 9 months for stable angina. There were no other primary or secondary outcome events in the cohort. There were no strokes, deaths, stent thrombosis or myocardial infarction during the follow-up period. The mean CCS score improved from 2.25 to 0.25 (p < 0.0001). Optical coherence tomography (OCT) and bench test findings indicated optimal side branch ostial coverage and minimal redundant strut material crowding the neo-carina. CONCLUSIONS: The CFCT technique appears to be a safe, efficacious and feasible strategy for managing coronary artery bifurcation disease. Expanded and randomized datasets with longer term follow-up are required to further explore confirm this feasibility data. (ANZCTR ID: ACTRN12618001145291).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA