Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Pulm Med ; 22(1): 477, 2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36522658

RESUMO

BACKGROUND: Gravity, and thus body position, can affect the regional distribution of lung ventilation and blood flow. Therefore, body positioning is a potential tool to improve regional ventilation, thereby possibly enhancing the effect of respiratory physiotherapy interventions. In this proof-of-concept study, functional respiratory imaging (FRI) was used to objectively assess effects of body position on regional airflow distribution in the lungs. METHODS: Five healthy volunteers were recruited. The participants were asked during FRI first to lie in supine position, afterwards in standardized right lateral position. RESULTS: In right lateral position there was significantly more regional ventilation also described as Imaging Airflow Distribution in the right lung than in the left lung (P < 0.001). Air velocity was significantly higher in the left lung (P < 0.05). In right lateral position there was significantly more airflow distribution in the right lung than in the left lung (P < 0.001). Significant changes were observed in airway geometry resulting in a decrease in imaged airway volume (P = 0.024) and a higher imaged airway resistance (P = 0.029) in the dependent lung. In general, the effect of right lateral position caused a significant increase in regional ventilation (P < 0.001) in the dependent lung when compared with the supine position. CONCLUSIONS: Changing body position leads to significant changes in regional lung ventilation, objectively assessed by FRI The volume based on the imaging parameters in the dependent lung is smaller in the lateral position than in the supine position. In right lateral decubitus position, airflow distribution is greater in dependent lung compared to the nondependent lung. TRIAL REGISTRATION: The trial has been submitted to www. CLINICALTRIALS: gov with identification number NCT01893697 on 07/02/2013.


Assuntos
Pulmão , Respiração Artificial , Humanos , Voluntários Saudáveis , Volume de Ventilação Pulmonar , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Respiração Artificial/métodos , Postura
2.
Sleep Breath ; 19(2): 637-44, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25335642

RESUMO

PURPOSE: The objective of this randomized controlled trial was to assess the additional effect of a chest-worn sleep position trainer (SPT) in patients with residual supine-dependent obstructive sleep apnea (sdOSA) under mandibular advancement device (MAD) therapy. METHODS: Baseline and follow-up polysomnography with MAD were performed. Twenty patients with sdOSA under MAD therapy underwent two consecutive randomized polysomnographies: one with SPT and one with combination of SPT + MAD. Data are presented as median (quartile 1, quartile 3). RESULTS: The SPT reduced the time spent in supine sleeping position compared to baseline and MAD therapy. Both MAD and SPT were individually effective in reducing the overall apnea/hypopnea index (AHI) significantly when compared to baseline from 20.8 (15.1; 33.6)/h at baseline to 11.0 (6.7; 13.8)/h and to 11.1 (3.5; 17.7)/h with MAD or SPT, respectively. The combination of SPT + MAD further reduced the overall AHI to 5.7 (3.6; 7.4), which was significantly lower than with MAD alone (p < 0.001) and SPT alone (p < 0.008), respectively. CONCLUSIONS: The results of this study indicate that combination of SPT + MAD leads to a higher therapeutic efficacy in patients with sdOSA under MAD therapy when compared to one of the treatment modalities alone.


Assuntos
Terapia Combinada , Avanço Mandibular/instrumentação , Placas Oclusais , Posicionamento do Paciente/instrumentação , Modalidades de Fisioterapia/instrumentação , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Decúbito Dorsal/fisiologia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia
3.
Thorax ; 68(1): 91-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22993169

RESUMO

BACKGROUND: Oral appliance (OA) therapy is increasingly prescribed as a non-continuous positive airway pressure treatment modality for sleep-disordered breathing (SDB). Although OA therapy is reported to be efficacious for the treatment of SDB, data on compliance remain limited to self-report. METHODS: In this 3-month prospective clinical trial, the main outcome was to assess the safety and feasibility of an objective measurement of compliance during OA therapy using an embedded microsensor thermometer with on-chip integrated readout electronics in 51 consecutive patients with an established diagnosis of SDB (AHI 18.0 ± 11.9/h; age 47 ± 10 y; BMI 26.6 ± 4.0 kg/m(2); men/women: 31/20). Patients were unaware of the purpose of the study. RESULTS: No microsensor-related adverse events were recorded. In addition, no problems were encountered during the readout of the compliance data. Out of 51 microsensors, one had a technical defect and was lost to follow-up. In this study, the overall objective mean rate of OA use was 6.6 ± 1.3 h per day with a regular OA users' rate of 82% at the 3-month follow-up. Statistical analysis revealed no significant differences between objective and self-reported OA compliance data in this study. Measurement of the objective OA compliance allowed us to calculate the mean disease alleviation (MDA) as the product of objective compliance and therapeutic efficacy. MDA serves as a measure of the overall therapeutic effectiveness, and turned out to be 51.1%. CONCLUSIONS: The results illustrate the safety and feasibility of objective measurement of OA compliance. The objective measurement of OA compliance allows for calculation of the MDA.


Assuntos
Sistemas Microeletromecânicos , Aparelhos Ortodônticos , Cooperação do Paciente/estatística & dados numéricos , Síndromes da Apneia do Sono/terapia , Adulto , Pressão Positiva Contínua nas Vias Aéreas/métodos , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Polissonografia/métodos , Estudos Prospectivos , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/diagnóstico , Termômetros
4.
J Clin Sleep Med ; 18(3): 739-750, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34608859

RESUMO

STUDY OBJECTIVES: Mandibular advancement devices (MADs) are a noninvasive treatment option for patients with obstructive sleep apnea (OSA) and act by increasing the upper airway volume. However, the exact therapeutic mechanism of action remains unclear. The aim of this study was to assess MAD mechanisms using functional imaging that combines imaging techniques and computational fluid dynamics and assess associations with treatment outcome. METHODS: One hundred patients with OSA were prospectively included and treated with a custom-made MAD at a fixed 75% protrusion. A low-dose computed tomography scan was made with and without MADs for computational fluid dynamics analysis. Patients underwent a baseline and 3-month follow-up polysomnography to evaluate treatment efficacy. A reduction in apnea-hypopnea index ≥ 50% defined treatment response. RESULTS: Overall, 71 patients completed both 3-month follow-up polysomnography and low-dose computed tomography scan with computational fluid dynamics analysis. MAD treatment significantly reduced the apnea-hypopnea index (16.5 [10.4-23.6] events/h to 9.1 [3.9-16.4] events/h; P < .001, median [quartile 1-quartile 3]) and significantly increased the total upper airway volume (8.6 [5.4-12.8] cm3 vs 10.7 [6.4-15.4] cm3; P = .003), especially the velopharyngeal volume (2.1 [0.5-4.1] cm3 vs 3.3 [1.8-6.0] cm3; P < .001). However, subanalyses in responders and nonresponders only showed a significant increase in the total upper airway volume in responders, not in nonresponders. CONCLUSIONS: MAD acts by increasing the total upper airway volume, predominantly due to an increase in the velopharyngeal volume. Responders showed a significant increase in the total upper airway volume with MAD treatment, while there was no significant increase in nonresponders. Findings add evidence to implement functional imaging using computational fluid dynamics in routine MAD outcome prediction. CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Predicting Therapeutic Outcome of Mandibular Advancement Device Treatment in Obstructive Sleep Apnea; URL: https://clinicaltrials.gov/ct2/show/NCT01532050; Identifier: NCT01532050. CITATION: Van Gaver H, Op de Beeck S, Dieltjens M, et al. Functional imaging improves patient selection for mandibular advancement device treatment outcome in sleep-disordered breathing: a prospective study. J Clin Sleep Med. 2022;18(3):739-750.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Placas Oclusais , Seleção de Pacientes , Estudos Prospectivos , Apneia Obstrutiva do Sono/diagnóstico por imagem , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento
5.
Respiration ; 78(2): 121-33, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19478479

RESUMO

This review discusses the pathophysiological aspects of sleep-disordered breathing, with focus on upper airway mechanics in obstructive and central sleep apnoea, Cheyne-Stokes respiration and obesity hypoventilation syndrome. These disorders constitute the end points of a spectrum with distinct yet interrelated mechanisms that lead to substantial pathology, i.e. increased upper airway collapsibility, control of breathing instability, increased work of breathing, disturbed ventilatory system mechanics and neurohormonal changes. Concepts are changing. Although sleep apnoea is considered more and more to be an increased loop gain disorder, the central type of apnoea is now considered as an obstructive event, because it causes pharyngeal narrowing, associated with prolonged expiration. Although a unifying concept for the pathogenesis is lacking, it seems that these patients are in a vicious circle. Knowledge of common patterns of sleep-disordered breathing may help to identify these patients and guide therapy.


Assuntos
Síndrome de Hipoventilação por Obesidade/fisiopatologia , Mecânica Respiratória , Apneia do Sono Tipo Central/fisiopatologia , Humanos , Síndrome de Hipoventilação por Obesidade/etiologia
7.
Am J Respir Crit Care Med ; 178(2): 197-202, 2008 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-17673699

RESUMO

RATIONALE: The efficacy of immediate adaptation of mandibular advancement devices made of thermoplastic material as a treatment option for sleep-disordered breathing (SDB) has been demonstrated in clinical studies. To date, there have been no studies comparing the efficacy of such prefabricated devices with custom-made devices. OBJECTIVES: Our purpose was to compare the efficacy of both types of devices in patients with SDB. METHODS: A randomized controlled cross-over trial, comprising 4 months of treatment with a thermoplastic and a custom-made device, with a 1-month washout interval. MEASUREMENTS AND MAIN RESULTS: A total of 35 patients (29 males; age, 49 +/- 9 yr; apnea-hypopnea index [AHI], 13 +/- 11 events/h; body mass index, 28 +/- 4 kg/m(2)) completed the protocol. AHI was only reduced with the custom-made device (P = 0.005). In addition, this device reduced snoring to a greater extent than the thermoplastic device. The success rate was higher with the custom-made device (60 vs. 31%; P = 0.02). One-third of the patients demonstrated compliance failure with the thermoplastic device, mainly because of insufficient overnight retention. Total failure rate with the thermoplastic device was 69%, whereas the majority (63%) of these were successfully treated with the custom-made device. At the end of the study, 82% of the patients preferred the custom-made device, and 9% had no preference (P < 0.0001). CONCLUSIONS: In this study, a custom-made device turned out to be more effective than a thermoplastic device in the treatment of SDB. Our results suggest that the thermoplastic device cannot be recommended as a therapeutic option nor can it be used as a screening tool to find good candidates for mandibular advancement therapy.


Assuntos
Avanço Mandibular/instrumentação , Aparelhos Ortodônticos Removíveis , Apneia Obstrutiva do Sono/terapia , Ronco/terapia , Análise de Variância , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia
8.
Sleep Breath ; 13(2): 207-10, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19002513

RESUMO

INTRODUCTION: The aim of this retrospective study was to investigate if sleep-disordered breathing (SDB) was an independent predictor of suspected fatty liver disease in a clinical sample of overweight children and adolescents. MATERIALS AND METHODS: Consecutive overweight and obese children attending a pediatric obesity clinic underwent polysomnography, fasting blood sample, and abdominal ultrasound. RESULTS AND DISCUSSION: The respiratory disturbance index, percentage of total sleep time with SO2 < 90%, and SaO2nadir were associated with higher alanine amino-transferases (ALT) independent of abdominal obesity. Multiple logistic regression selected waist circumference (odds ratio = 1.05; p = 0.05) and SaO2nadir (odds ratio = 0.87; p = 0.03) as predictors of suggestive fatty liver disease, defined as ALT > 40 U/L and/or hyperechoic liver on abdominal ultrasound. This study supports the association between the severity of SDB and suspected fatty liver disease in a clinical sample of overweight children and adolescents. We recommend more research on the influence of SDB on the development of fatty liver disease and on the effect of treating sleep apnea on liver function parameters.


Assuntos
Fígado Gorduroso/epidemiologia , Obesidade Mórbida/epidemiologia , Sobrepeso , Síndromes da Apneia do Sono/epidemiologia , Adolescente , Índice de Massa Corporal , Criança , Feminino , Humanos , Masculino , Fatores de Risco , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/diagnóstico
9.
J Clin Sleep Med ; 15(8): 1089-1099, 2019 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-31482830

RESUMO

STUDY OBJECTIVES: Mandibular advancement device (MAD) outcome varies between patients. We hypothesized that upper airway collapse sites, patterns, and degrees assessed during baseline drug-induced sleep endoscopy (DISE) affect MAD outcome. METHODS: One hundred patients with obstructive sleep apnea (OSA) were included and underwent baseline type 1 polysomnography. MAD was fitted intraorally at fixed 75% maximal protrusion. A total of 72 patients completed 3-month follow-up polysomnography and baseline DISE. Response was defined as apnea-hypopnea index (AHI) reduction ≥ 50%, deterioration as AHI increases during MAD treatment compared to baseline. RESULTS: Adjusting for baseline AHI and body mass index, patients with tongue base collapse showed 3.69 higher odds (1.27-10.73; P = .0128) for response. Complete concentric collapse at the level of the palate (5.32 [1.21-23.28]; P = .0234) and complete laterolateral oropharyngeal collapse (6.62 [1.14-38.34]; P = .0330) related to deterioration. Results for tongue base collapse and complete concentric collapse at the level of the palate were confirmed in the moderate to severe OSA subgroup. Applying these results to this selected subgroup increased response rate with 54% and decreased deterioration rate with 53%. These results were confirmed using other response and deterioration definitions. CONCLUSIONS: Three baseline DISE phenotypes identified during drug-induced sleep were significantly related to MAD treatment outcome: one beneficial, tongue base collapse, and two adverse, complete concentric collapse at the level of the palate and complete laterolateral oropharyngeal collapse. If confirmed in future prospective studies, these results could guide patient selection for MAD outcome. CLINICAL TRIAL REGISTRATION: This prospective clinical trial (PROMAD) was registered on Clinicaltrials.gov with identifier: NCT01532050. CITATION: Op de Beeck S, Dieltjens M, Verbruggen AE, Vroegop AV, Wouters K, Hamans E, Willemen M, Verbraecken J, De Backer WA, Van de Heyning PH, Braem MJ, Vanderveken OM. Phenotypic labelling using drug-induced sleep endoscopy improves patient selection for mandibular advancement device outcome: a prospective study. J Clin Sleep Med. 2019;15(8):1089-1099.


Assuntos
Endoscopia/métodos , Placas Oclusais , Apneia Obstrutiva do Sono/terapia , Feminino , Humanos , Hipnóticos e Sedativos/uso terapêutico , Masculino , Pessoa de Meia-Idade , Polissonografia , Estudos Prospectivos , Apneia Obstrutiva do Sono/etiologia , Apneia Obstrutiva do Sono/fisiopatologia , Língua/fisiopatologia , Resultado do Tratamento
10.
J Clin Sleep Med ; 14(4): 575-583, 2018 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-29609712

RESUMO

STUDY OBJECTIVES: To assess the overall clinical effectiveness of a sleep position trainer (SPT) in patients with positional obstructive sleep apnea (POSA) and to evaluate how many patients were willing to continue treatment after a 1-month trial period. METHODS: Patients in whom POSA was diagnosed underwent a 1-month trial period with the SPT. Home sleep apnea tests were used to measure baseline data and data following the trial period with the SPT. RESULTS: The 79 patients who completed the study protocol were 81% male, had a mean age of 52 ± 12 years, and a median baseline respiratory event index (REI) of 11 (8, 16) events/h. A significant reduction in overall REI to 5 (3, 10) events/h was observed with the SPT as compared to baseline (P < .001). The median percentage of sleep time in the supine position decreased significantly from 27 (20, 48) to 7 (2, 20) with the SPT (P < .001). Adherence was found to be 95 ± 8%. Of the 44 patients who decided to continue treatment, 27 were categorized as responders (having a decrease in REI of at least 50%) and 17 were non-responders. The most important reasons for not purchasing the SPT were poor objective results, intolerance to the vibrations, cost of the device, persistent daytime sleepiness, or patient preference for other treatment options. CONCLUSIONS: Treatment with the SPT came with high adherence rates and was effective in reducing REI and supine sleep position. The trial period is in the patients' best interest, as it may prevent those who will not benefit from positional training from purchasing an SPT.


Assuntos
Educação de Pacientes como Assunto/métodos , Apneia Obstrutiva do Sono/terapia , Decúbito Dorsal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Sono , Apneia Obstrutiva do Sono/prevenção & controle , Resultado do Tratamento
11.
Chest ; 132(1): 76-80, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17505038

RESUMO

OBJECTIVE: The aim of this study was to determine whether the severity of sleep-disordered breathing (SDB) was associated with increased levels of uric acid (UA), both in serum and in urine, as a marker of tissue hypoxia, in a sample of overweight and obese subjects, irrespective of indexes of adiposity. METHODS: Consecutive subjects underwent polysomnography, fasting blood sampling, and 24-h urine collection. Outcome parameters were serum UA, UA excretion ([24-h urinary UA x serum creatinine]/urine creatinine) and urinary UA/creatinine ratio. RESULTS: A total of 93 subjects were included (44% boys; mean [+/- SD] age = 11.1 +/- 2.5; 73% obese). A fasting measurement of serum UA levels was available for 62 patients. The respiratory disturbance index was a significant covariate (beta = 0.09 +/- 0.03; p = 0.01) in the regression model for serum UA, controlling for sex (beta = 0.32 +/- 0.29; p = 0.3), puberty (beta = 0.87 +/- 0.34; p = 0.01), and waist circumference (beta = 0.04 +/- 0.01; p = 0.005). The percentage of total sleep time with arterial oxygen saturation < or = 89% (beta = 0.94 +/- 0.45; p = 0.04) was also significantly associated with serum UA level, controlling for sex (beta = 0.22 +/- 0.30; p = 0.5), puberty (beta = 0.83 +/- 0.35; p = 0.02), and waist circumference (beta = 0.04 +/- 0.02; p = 0.02). None of the SDB variables correlated with UA excretion or with urinary UA/creatinine ratio. CONCLUSION: This study in overweight children and adolescents demonstrated a relationship between the severity of sleep apnea and increased levels of serum UA, independent of abdominal adiposity. In view of the known associations between UA and cardiovascular risk, this finding may contribute to the mechanisms linking SDB with cardiovascular morbidity.


Assuntos
Obesidade/fisiopatologia , Sobrepeso/fisiologia , Síndromes da Apneia do Sono/fisiopatologia , Ácido Úrico/sangue , Ácido Úrico/urina , Adiposidade/fisiologia , Adolescente , Biomarcadores/sangue , Biomarcadores/urina , Criança , Feminino , Humanos , Hipóxia/sangue , Hipóxia/diagnóstico , Hipóxia/urina , Modelos Lineares , Masculino , Obesidade/sangue , Obesidade/urina , Estresse Oxidativo/fisiologia , Polissonografia , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/sangue , Síndromes da Apneia do Sono/urina
12.
Front Neurosci ; 11: 523, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28983236

RESUMO

Obstructive sleep apnea (OSA) is a common disease with high morbidity and related mortality. Narrowing and collapse of the pharyngeal airway during sleep characterize the disease, resulting in a decrease (hypopnea) or a complete cessation (apnea) of oronasal airflow. Upper airway stimulation (UAS), using electrical neurostimulation of the hypoglossal nerve (n. XII) synchronized with ventilation, is a novel, evolving treatment option. UAS was found to be an effective treatment in CPAP-intolerant patients. The treatment success is partly due to the strict selection of the patients, based on previous findings. Furthermore, post-operative follow-up is needed in order to maintain or improve treatment outcome. Therefore, a clinical pathway, which provides structure and standardization, is crucial. In this paper, the aim is to discuss the technical aspects of UAS therapy and to describe a clinical pathway to organize the care process of UAS for OSA in a structured and standardized way.

13.
Chest ; 128(4): 2465-70, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16236910

RESUMO

BACKGROUND: Exhaled nitric oxide (eNO) is a convenient noninvasive marker for airway inflammation in several pulmonary diseases. However, external factors such as nitrate-rich nutrition can affect the levels of eNO and thus compromise its diagnostic value. STUDY OBJECTIVES: The objective of this investigation was to have a better understanding of the time-dependent effect of nitrate-rich meals on eNO in healthy subjects. STUDY DESIGN: Forty-two healthy, nonsmoking volunteers (age range, 25 to 62 years) were recruited for the study. They had no recent respiratory tract infections and were free of pulmonary history, rhinitis, and atopic disorders. eNO was measured before, and 0.5, 2, 4, 12, 15, and 20 h after the intake of a nitrate-rich meal equivalent to 230 mg of nitrate. RESULTS: The intake of a nitrate-rich meal increased eNO by 60% 2 h after the meal. Even after 15 h, the mean eNO value was still 22% higher than the baseline value. Only after 20 h did eNO return to the normal baseline level. CONCLUSION: This finding stresses the importance of advising patients to avoid nitrate-rich nutrition at least 20 h before a scheduled measurement of eNO.


Assuntos
Ingestão de Alimentos , Nitratos , Óxido Nítrico/análise , Adulto , Biomarcadores/análise , Testes Respiratórios , Intervalos de Confiança , Feminino , Humanos , Pneumopatias/diagnóstico , Pneumopatias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valores de Referência , Fatores de Tempo
14.
Eur J Cardiothorac Surg ; 27(4): 611-6, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15784359

RESUMO

OBJECTIVE: Cardiac surgery may lead to severe oxidative stress due to formation of oxidation products generated during ischemia and reperfusion. We investigated to which extent oxidative stress influences a number of endogenous antioxidants and markers of cellular activation. METHODS: At six time points blood was withdrawn from patients undergoing coronary artery bypass grafting, using the on-pump procedure. RESULTS: Both glutathione peroxidase and superoxide dismutase show a gradual and strong increase in activity during surgery (40 and 30%, respectively), returning to baseline values 24 h after surgery. The total antioxidant capacity has a maximum increase of 60%. Markers of cellular activation, such as eosinophil cationic protein and tryptase also increase during the procedure. CONCLUSION: Cardiac surgery results in systemic inflammation accompanied or caused by severe oxidative stress. The human body has a strong innate oxidative defence screen, which is probably not sufficient to fully compensate for the total amount of oxidative damage.


Assuntos
Antioxidantes/metabolismo , Ponte Cardiopulmonar , Ponte de Artéria Coronária , Estresse Oxidativo , Idoso , Biomarcadores/sangue , Proteína Catiônica de Eosinófilo/sangue , Feminino , Glutationa Peroxidase/sangue , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Serina Endopeptidases/sangue , Superóxido Dismutase/sangue , Triptases
15.
JAMA Otolaryngol Head Neck Surg ; 141(10): 894-900, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26402736

RESUMO

IMPORTANCE: The main reported reasons for discontinuation of oral appliance therapy for sleep-disordered breathing (SDB) are the presence of self-perceived adverse effects and self-appreciated lack of efficacy. However, these conclusions rely only on subjective compliance data. OBJECTIVE: To determine which parameters are correlated with objectively measured data on compliance with oral appliance therapy. DESIGN, SETTING, AND PARTICIPANTS: For 51 outpatients with SDB, a prospective clinical trial using oral appliance therapy was conducted at Antwerp University Hospital from February 7, 2011, to October 8, 2013 (38 [75%] males; mean [SD] age, 49.3 [9.0] years; mean [SD] apnea-hypopnea index, 14.9 [9.3] events per hour of sleep; mean [SD] body mass index [calculated as weight in kilograms divided by height in meters squared], 26.3 [2.8]). Analysis was performed November 5, 2014. INTERVENTION: Oral appliance therapy with a custom-made, titratrable mandibular advancement device (OAm). MAIN OUTCOMES AND MEASURES: Possible correlations were assessed between objective compliance and patients' anthropometric characteristics, polysomnographic parameters, and answers to 3 subjective questionnaires (the visual analog scale for snoring, the Epworth Sleepiness Scale, and an adverse effects questionnaire). RESULTS: Median oral appliance use was 6.4 hours per night (range, 4.7-7.2 hours per night) at the 3-month follow-up. None of the anthropometric and polysomnographic parameters were correlated with compliance. No correlation was found between objective compliance and reports of excessive daytime sleepiness. However, a significant inverse correlation was found between objective compliance and posttreatment visual analog scale values for snoring (P = .006; ρ = ­.40). In addition, objective compliance was correlated significantly with a more pronounced decrease in socially disturbing snoring (P = .005; ρ = 0.39). The presence of dry mouth was the only adverse effect that was negatively correlated with objective compliance at the 3-month follow-up (P < .05; ρ = ­.31). CONCLUSIONS AND RELEVANCE: Neither the anthropometric and polysomnographic parameters nor reports of excessive daytime sleepiness correlated with compliance during oral appliance therapy. The 2 parameters that were correlated with higher objective compliance during oral appliance therapy were a more pronounced decrease in snoring and the presence of dry mouth during treatment. TRIAL REGISTRATION: clinicaltrials.gov Identifiers: NCT01284881 and NCT01532050.


Assuntos
Avanço Mandibular/instrumentação , Cooperação do Paciente , Síndromes da Apneia do Sono/psicologia , Síndromes da Apneia do Sono/terapia , Adulto , Feminino , Humanos , Masculino , Avanço Mandibular/efeitos adversos , Pessoa de Meia-Idade , Polissonografia , Estudos Prospectivos , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
16.
Eur J Pharmacol ; 477(3): 261-7, 2003 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-14522365

RESUMO

Neutrophil infiltration to the airway lumen is a common feature of respiratory inflammatory processes. The aim of this study was to evaluate whether different corticosteroids exert any selective effect on the migration of isolated neutrophils. A bilayer of cultured human endothelial and bronchial epithelial cells was used as a model for neutrophil migration through the blood-air barrier. Low spontaneous migration of neutrophils (2.8+/-0.9%, n=8; mean+/-S.E.M.) occurred, while in the absence of any steroid, a migration of 28.5+/-7.6% could be induced by lipopolysaccharide. Pre-incubation during 1 h of epithelial cells with dexamethasone, budesonide, or prednisolone (10(-10)-10(-4) M) showed in all instances a concentration-dependent inhibition following a bell-shaped curve. At 10(-7) M, both dexamethasone and budesonide were on the minimum effect peak of the bell-shaped curve. The peak for prednisolone was found at 10(-8) M. However, when steroid pre-incubation was extended to 4 h, a sigmoid curve was observed, with significant inhibition of migration at concentrations >10(-7) M. Steroids can inhibit neutrophil recruitment through two different pathways with distinct result, depending on the length of incubation time.


Assuntos
Brônquios/efeitos dos fármacos , Endotélio Vascular/efeitos dos fármacos , Células Epiteliais/efeitos dos fármacos , Infiltração de Neutrófilos/efeitos dos fármacos , Esteroides/farmacologia , Brônquios/citologia , Brônquios/fisiologia , Linhagem Celular , Movimento Celular/efeitos dos fármacos , Movimento Celular/fisiologia , Relação Dose-Resposta a Droga , Endotélio Vascular/citologia , Endotélio Vascular/fisiologia , Células Epiteliais/citologia , Células Epiteliais/metabolismo , Humanos , Interleucina-1/farmacologia , Lipopolissacarídeos/farmacologia , Infiltração de Neutrófilos/fisiologia , Neutrófilos/efeitos dos fármacos , Neutrófilos/metabolismo , Pregnanos/farmacologia , Esteroides/química , Fatores de Tempo , Fator de Necrose Tumoral alfa/farmacologia
17.
Acta Otolaryngol ; 124(5): 628-33, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15267184

RESUMO

OBJECTIVE: Mandibular advancement devices (MADs) have been introduced as a conservative, non-invasive treatment for socially disturbing snoring and mild obstructive sleep apnea (OSA). A prospective, non-randomized pilot study was conducted to investigate the efficacy, feasibility, side-effects and compliance of Somnoguard, an immediately intraorally adaptable MAD made from thermoplastic material. MATERIAL AND METHODS: Twenty consecutive heavy snorers with a respiratory disturbance index of <20 events/h were prospectively selected. Prior to the adaptation of the appliance, ambulatory polygraphy was carried out without a MAD. After a 1-month habituation period, a polygraphic evaluation was carried out with the device. Treatment success was defined as a reduction in the apnea-hypopnea index (AHI) of at least 50%. RESULTS: The results indicated a success rate of 65%. The AHI decreased from 8.4 +/- 2.9 events/h at baseline to 3.9 +/- 1.8 events/h with the device (p = 0.001). At 1-month follow-up, significant reductions in the snoring index (p < 0.001) and the Epworth Sleepiness Scale (ESS) score (p = 0.036) were noted. At 6-month follow-up, similar results were achieved, with significant drops in the snoring index (p = 0.025) and ESS score (p = 0.033). CONCLUSION: We conclude that immediate intraoral adaptation of a low-cost fabricated "one-size-only" MAD is a feasible and well-tolerated treatment for snoring and mild OSA. Further research is needed to evaluate this thermoplastic appliance as a strategy to "screen" the efficacy of MAD treatment in the individual patient with a less expensive appliance before constructing a more expensive custom-made MAD.


Assuntos
Avanço Mandibular/instrumentação , Ronco/terapia , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Satisfação do Paciente , Projetos Piloto , Plásticos , Polissonografia , Estudos Prospectivos , Resultado do Tratamento
18.
Respir Care ; 59(9): e127-31, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24327746

RESUMO

A completely different treatment approach was chosen for 2 patients with unilateral diaphragmatic paralysis and complaints of dyspnea despite similar anatomic and physiologic abnormalities. These decisions were supported by results obtained by functional respiratory imaging (FRI). FRI generated functional information on lobar ventilation and local drug deposition. In the first patient, some lobes were poorly ventilated, and drug deposition simulation showed that some regions were undertreated. This patient underwent diaphragmatic plication to restore ventilation. In the second patient, all lobes were still ventilated. A conservative approach with regular follow-ups was chosen to wait for spontaneous recovery of the diaphragmatic function. Both patients improved subjectively and objectively. These cases demonstrate how novel medical imaging techniques such as FRI can be used to personalize respiratory treatment in patients with unilateral diaphragmatic paralysis.


Assuntos
Broncodilatadores/farmacocinética , Diafragma , Imageamento Tridimensional/métodos , Paralisia Respiratória/diagnóstico por imagem , Paralisia Respiratória/fisiopatologia , Diafragma/cirurgia , Dispneia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Medicina de Precisão , Ventilação Pulmonar , Paralisia Respiratória/terapia , Tomografia Computadorizada por Raios X
19.
J Aerosol Med Pulm Drug Deliv ; 27(1): 51-7, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23509935

RESUMO

BACKGROUND: As the upper airway is the most important limiting factor for the deposition of inhalation medication in the lower airways, it is interesting to assess how its morphology varies between different postures. The goal of this study is to compare the upper airway morphology and functionality of healthy volunteers in the upright and supine positions during tidal nasal breathing and to search for baseline indicators for these changes. This is done by performing three-dimensional measurements on computed tomography (CT) and cone beam computed tomography (CBCT) scans. METHODS: This prospective study was approved by all relevant institutional review boards. All patients gave their signed informed consent. In this study, 20 healthy volunteers (mean age, 62 years; age range, 37-78 years; mean body mass index, 29.26; body mass index range, 21.63-42.17; 16 men, 4 women) underwent a supine low-dose CT scan and an upright CBCT scan of the upper airway. The (local) average (Savg) and minimal (Smin) cross-sectional area, the position of the latter, the concavity, and the airway resistance were examined to determine if they changed from the upright to the supine position. If changes were found, baseline parameters were sought that were indicators for these differences. RESULTS: There were five dropouts due to movement artifacts in the CBCT scans. Savg and Smin were 9.76% and 26.90% larger, respectively, in the CBCT scan than in the CT scan, whereas the resistance decreased by 26.15% in the upright position. The Savg of the region between the hard palate and the bottom of the uvula increased the most (49.85%). In people with a high body mass index, this value changed the least. The airway resistance in men decreased more than in women. CONCLUSIONS: This study demonstrated that there are differences in upper airway morphology and functionality between the supine and upright positions and that there are baseline indicators for these differences.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Respiração , Sistema Respiratório/diagnóstico por imagem , Decúbito Dorsal , Tomografia Computadorizada por Raios X , Adulto , Idoso , Resistência das Vias Respiratórias , Feminino , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Fatores Sexuais
20.
Chest ; 144(5): 1495-1502, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23928873

RESUMO

BACKGROUND: Assessment of the overall therapeutic effectiveness of oral appliance therapy can only be realized through objectively measured compliance. The aims of this study were to assess objectively measured compliance during oral appliance therapy at 1-year follow-up and to compare these data with self-reported use. METHODS: Fifty-one eligible patients were enrolled in this 1-year prospective clinical study (men, 61%; mean age, 49 ± 10 years; apnea-hypopnea index, 18.0 ± 11.9 events/h sleep; BMI, 26.6 ± 4.1 kg/m²). Objective compliance during oral appliance therapy at 1-year follow-up was assessed with a microsensor thermometer. Subjective compliance was assessed by self-report. Patients with a mean objectively measured use of ≥ 4 h/night on 70% of nights monitored were considered regular users. The mean disease alleviation was calculated as a measure of overall therapeutic effectiveness. RESULTS: High agreement between objective and subjective compliance data at 1-year follow-up was reported (intraclass correlation coefficient, 0.8; 95% CI, 0.5-0.9), showing a mean subjective overestimation of 30 min (95% CI, -3.1 to 1.9; P = .02). The discontinuation rate at 1-year follow-up was 9.8%. The objective mean use rate was 6.4 ± 1.7 h/night at 1-year follow-up in continuing users, with a regular use rate of 83%. The mean disease alleviation was 54.9%. CONCLUSIONS: This study is the first to our knowledge to report the 1-year results of objectively measured compliance during oral appliance therapy. In addition, a high agreement between objective and subjective compliance data were reported, with a mean subjective overestimation of 30 min. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01284881; URL: www.clinicaltrials.gov.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Cooperação do Paciente , Autorrelato , Síndromes da Apneia do Sono/terapia , Sono , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Polissonografia , Estudos Prospectivos , Síndromes da Apneia do Sono/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA