Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Arch Cardiovasc Dis ; 117(3): 186-194, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38326152

RESUMO

BACKGROUND: An implantable loop recorder is an effective tool for diagnosing unexplained syncope. However, after a first episode in non-high-risk patients, the usefulness of implantable loop recorder implantation remains unclear. AIMS: To analyse relevant risk factors for significant bradycardia in order to identify patients who do or do not benefit from implantable loop recorder implantation. Also, to study whether implantable loop recorder implantation with remote monitoring is associated with less recurrence of traumatic syncope. METHODS: This was a retrospective monocentric study including patients with implantable loop recorder implantation after unexplained syncope, using remote monitoring and iterative consultations. RESULTS: Two hundred and thirty-seven patients were implanted for unexplained syncope. Significant bradycardia occurred in 53 patients (22.4%): 23 (43.4%) caused by paroxysmal atrioventricular block and 30 (56.6%) caused by sinus node dysfunction, leading to permanent pacemaker implantation in 48 patients. Compared with younger patients, there was a 3.46-fold increase (95% confidence interval 1.92-6.23; P<0.0001) in the risk of significant bradycardia in patients aged≥60 years. Based on multivariable analysis, only "typical syncope" was associated with significant bradycardia occurrence (hazard ratio 3.14, 95% confidence interval 1.75-5.65; P=0.0001). There was no recurrence of significant bradycardia with traumatic complications among patients implanted for traumatic syncope. CONCLUSIONS: This study shows that: (1) implantable loop recorders identify more significant bradycardia in patients aged≥60 presenting with a first non-high-risk typical syncope, suggesting that an implantable loop recorder should be implanted after a first episode of unexplained syncope in such conditions; and (2) after traumatic syncope, implantable loop recorder implantation is safe, and is associated with little or no recurrence of traumatic syncope.


Assuntos
Bradicardia , Síncope , Humanos , Bradicardia/diagnóstico , Bradicardia/terapia , Bradicardia/complicações , Estudos Retrospectivos , Síncope/diagnóstico , Síncope/etiologia , Síncope/terapia , Eletrocardiografia Ambulatorial/efeitos adversos , Medição de Risco , Eletrodos Implantados/efeitos adversos
2.
Intensive Care Med Exp ; 11(1): 51, 2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37574520

RESUMO

BACKGROUND: The immuno-receptor Triggering Expressed on Myeloid cells-1 (TREM-1) is activated during bacterial infectious diseases, where it amplifies the inflammatory response. Small studies suggest that TREM-1 could be involved in viral infections, including COVID-19. We here aim to decipher whether plasma concentration of the soluble form of TREM-1 (sTREM-1) could predict the outcome of hospitalized COVID-19 patients. METHODS: We conducted a multicentre prospective observational study in 3 university hospitals in France. Consecutive hospitalized patients with confirmed infection with SARS-CoV-2 were enrolled. Plasma concentration of sTREM-1 was measured on admission and then at days 4, 6, 8, 14, 21, and 28 in patients admitted into an ICU (ICU cohort: ICUC) or 3 times a week for patients hospitalized in a medical ward (Conventional Cohort: ConvC). Clinical and biological data were prospectively recorded and patients were followed-up for 90 days. For medical ward patients, the outcome was deemed complicated in case of requirement of increased oxygen supply > 5 L/min, transfer to an ICU, or death. For Intensive Care Unit (ICU) patients, complicated outcome was defined by death in the ICU. RESULTS: Plasma concentration of sTREM-1 at inclusion was higher in ICU patients (n = 269) than in medical ward patients (n = 562) (224 pg/mL (IQR 144-320) vs 147 pg/mL (76-249), p < 0.0001), and higher in patients with a complicated outcome in both cohorts: 178 (94-300) vs 135 pg/mL (70-220), p < 0.0001 in the ward patients, and 342 (288-532) vs 206 pg/mL (134-291), p < 0.0001 in the ICU patients. Elevated sTREM-1 baseline concentration was an independent predictor of complicated outcomes (Hazard Ratio (HR) = 1.5 (1.1-2.1), p = 0.02 in ward patients; HR = 3.8 (1.8-8.0), p = 0.0003 in ICU patients). An sTREM-1 plasma concentration of 224 pg/mL had a sensitivity of 42%, and a specificity of 76% in the ConvC for complicated outcome. In the ICUC, a 287 pg/mL cutoff had a sensitivity of 78%, and a specificity of 74% for death. The sTREM-1 concentrations increased over time in the ConvC patients with a complicated outcome (p = 0.017), but not in the ICUC patients. CONCLUSIONS: In COVID-19 patients, plasma concentration of sTREM-1 is an independent predictor of the outcome, although its positive and negative likelihood ratio are not good enough to guide clinical decision as a standalone marker.

3.
EClinicalMedicine ; 60: 102031, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37350990

RESUMO

Background: Venous thromboembolism is a major complication of coronavirus disease 2019 (COVID-19). We hypothesized that a weight-adjusted intermediate dose of anticoagulation may decrease the risk of venous thromboembolism COVID-19 patients. Methods: In this multicenter, randomised, open-label, phase 4, superiority trial with blinded adjudication of outcomes, we randomly assigned adult patients hospitalised in 20 French centers and presenting with acute respiratory SARS-CoV-2. Eligible patients were randomly assigned (1:1 ratio) to receive an intermediate weight-adjusted prophylactic dose or a fixed-dose of subcutaneous low-molecular-weight heparin during the hospital stay. The primary outcome corresponded to symptomatic deep-vein thrombosis (fatal) pulmonary embolism during hospitalization (COVI-DOSE ClinicalTrials.gov number: NCT04373707). Findings: Between May 2020, and April 2021, 1000 patients underwent randomisation in medical wards (noncritically ill) (80.1%) and intensive care units (critically ill) (19.9%); 502 patients were assigned to receive a weight-adjusted intermediate dose, and 498 received fixed-dose thromboprophylaxis. Symptomatic venous thromboembolism occurred in 6 of 502 patients (1.2%) in the weight-adjusted dose group and in 10 of 498 patients (2.1%) in the fixed-dose group (subdistribution hazard ratio, 0.59; 95% CI, 0.22-1.63; P = 0.31). There was a twofold increased risk of major or clinically relevant nonmajor bleeding: 5.9% in the weight-adjusted dose group and 3.1% in the fixed-dose group (P = 0.034). Interpretation: In the COVI-DOSE trial, the observed rate of thromboembolic events was lower than expected in patients hospitalized for COVID-19 infection, and the study was unable to show a significant difference in the risk of venous thromboembolism between the two low-molecular-weight-heparin regimens. Funding: French Ministry of Health, CAPNET, Grand-Est Region, Grand-Nancy Métropole.

4.
Arch Cardiovasc Dis ; 114(10): 634-646, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34742672

RESUMO

BACKGROUND: Despite guidelines describing the optimal diagnostic and therapeutic procedures for patients with suspected cardiac implantable electronic device (CIED) infections, their management is often challenging. AIMS: To describe our diagnostic and therapeutic practices for suspected CIED infection, and to compare them with European Heart Rhythm Association (EHRA) guidelines. METHODS: Patients hospitalized in the tertiary care Nancy University Hospital for suspected CIED infection from 2014 to 2019 were included retrospectively. We applied the EHRA classification of CIED infection, and compared diagnostic and therapeutic management with the EHRA guidelines. RESULTS: Among 184 patients (mean age 72.3±12.4 years), 137 had a proven infection of the lead (by transthoracic echocardiography/transoesophageal echocardiography, 18F-fluorodesoxyglucose positron emission tomography/computed tomography or positive culture of the lead) or an isolated pocket infection without proof of lead infection, and 47 had no proof of CIED infection. According to the EHRA classification, CIED infection was considered as definite in 145 patients and possible in 31 and was excluded in eight patients. Regarding recommended diagnostic procedures, blood cultures were performed in 90.8%, transthoracic echocardiography in 97.8%, transoesophageal echocardiography in 85.9%, 18F-fluorodesoxyglucose positron emission tomography/computed tomography in 50.5% and imaging for embolisms in 78.3% of the patients. Compared with therapeutic recommendations for the 145 cases of definite CIED infection, device removal was performed in 96 patients (66.2%) and antibiotic therapy was prescribed in 130 (89.7%), with a duration equal to or longer than that recommended in 105 (72.4%) of the patients. CONCLUSION: This study underlines the difficulties in following theoretical guidelines in daily practice, where both technical and human considerations interfere with their strict appliance.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Humanos , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/terapia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA