Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
World J Urol ; 42(1): 266, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38676726

RESUMO

PURPOSE: Considering the existing gaps in the literature regarding patient radiation dose (RD) and its associated risks, a systematic review of the literature on RD was conducted, focusing on percutaneous nephrolithotomy (PCNL), extracorporeal shock wave lithotripsy (SWL), and ureteroscopy (URS). METHODS: Two authors conducted a literature search on PubMed, Web of Science, and Google Scholar to identify studies on RD during endourological procedures. Two thousand two hundred sixty-six articles were screened. Sixty-five publications met the inclusion criteria using the PRISMA standards. RESULTS: RD was generally highest for PCNL, reaching levels up to 33 mSv, 28,700 mGycm2, and 430.8 mGy. This was followed by SWL, with RD reaching up to 7.32 mSv, 13,082 mGycm2, and 142 mGy. URS demonstrated lower RD, reaching up to 6.07 mSv, 8920 mGycm2, and 46.99 mGy. Surgeon experience and case load were inversely associated with RD. Strategies such as optimizing fluoroscopy settings, implementing ultrasound (US), and following the ALARA (As Low As Reasonably Achievable) principle minimized RD. CONCLUSIONS: This is the first systematic review analyzing RD, which was generally highest during PCNL, followed by SWL and URS. There is no specific RD limit for these procedures. Implementation of strategies such as optimizing fluoroscopy settings, utilizing US, and adhering to the ALARA principle proved effective in reducing RD. However, further research is needed to explore the factors influencing RD, assess their impact on patient outcomes, and establish procedure-specific reference levels for RD.


Assuntos
Litotripsia , Nefrolitotomia Percutânea , Exposição à Radiação , Ureteroscopia , Humanos , Ureteroscopia/efeitos adversos , Nefrolitotomia Percutânea/efeitos adversos , Nefrolitotomia Percutânea/métodos , Litotripsia/efeitos adversos , Litotripsia/métodos , Doses de Radiação
2.
World J Urol ; 42(1): 46, 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38244083

RESUMO

PURPOSE: Urolithiasis has become increasingly prevalent, leading to higher disability-adjusted life years and deaths. Various stone classification systems have been developed to enhance the understanding of lithogenesis, aid urologists in treatment decisions, and predict recurrence risk. The aim of this manuscript is to provide an overview of different stone classification criteria. METHODS: Two authors conducted a review of literature on studies relating to the classification of urolithiasis. A narrative synthesis for analysis of the studies was used. RESULTS: Stones can be categorized based on anatomical position, size, medical imaging features, risk of recurrence, etiology, composition, and morphoconstitutional analysis. The first three mentioned offer a straightforward approach to stone classification, directly influencing treatment recommendations. With the routine use of CT imaging before treatment, precise details like anatomical location, stone dimensions, and Hounsfield Units can be easily determined, aiding treatment planning. In contrast, classifying stones based on risk of recurrence and etiology is more complex due to dependencies on multiple variables, including stone composition and morphology. A classification system based on morphoconstitutional analysis, which combines morphological stone appearance and chemical composition, has demonstrated its value. It allows for the rapid identification of crystalline phase principles, the detection of crystalline conversion processes, the determination of etiopathogenesis, the recognition of lithogenic processes, the assessment of crystal formation speed, related recurrence rates, and guidance for selecting appropriate treatment modalities. CONCLUSIONS: Recognizing that no single classification system can comprehensively cover all aspects, the integration of all classification approaches is essential for tailoring urolithiasis patient-specific management.


Assuntos
Litotripsia , Urolitíase , Humanos , Urolitíase/terapia , Diagnóstico por Imagem , Litotripsia/métodos , Urologistas
3.
World J Urol ; 42(1): 277, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38691160

RESUMO

PURPOSE: To prospectively evaluate the rate and associated risk factors of early infectious complications after ureterorenoscopy for urolithiasis. METHODS: After ethical committee approval, 400 therapeutic retrograde ureterorenoscopy procedures between August 3, 2020 and November 24, 2021 were included for analysis in a single-center study. Postoperative infection was defined as an afebrile urinary tract infection, fever (≥ 38 °C) with pyuria (≥ 300 WBC/µL) or proven urinary pathogen, and urosepsis. The primary outcome was the rate of infectious complications after ureterorenoscopy. Secondary outcomes were the perioperative factors that increased the risk of infectious complications within 30 days of surgery using univariate and multivariate logistic regression analysis. RESULTS: Twenty-nine of four hundred (7.3%) patients developed an infectious complication within 30 days after ureterorenoscopy. Ten (2.5%) patients developed an afebrile urinary tract infection, eight (2.0%) developed fever with pyuria, five (1.3%) febrile urinary tract infection, and six (1.5%) urosepsis. On univariate analysis, preoperative stent-type JFil® pigtail suture stent was significantly associated with the dependent variable (p < 0.001). On multivariate logistic regression analysis, older age (OR 1.035; 95% CI 1.006-1.070; p = 0.02) was found to be significantly associated with developing a postoperative infectious complication. CONCLUSIONS: A 7.3% rate of postoperative infectious complications and 1.5% urosepsis rate were observed after therapeutic ureterorenoscopy, without the need of intensive care admission. The only significant risk factors were preoperative stent type (JFil® pigtail suture stent) on univariate analysis, and older age on multivariate logistic regression analysis. Further multicentric prospective observational data are needed in this field.


Assuntos
Complicações Pós-Operatórias , Ureteroscopia , Infecções Urinárias , Humanos , Masculino , Feminino , Estudos Prospectivos , Fatores de Risco , Ureteroscopia/efeitos adversos , Pessoa de Meia-Idade , Infecções Urinárias/epidemiologia , Infecções Urinárias/etiologia , Adulto , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Idoso , Fatores de Tempo , Sepse/etiologia , Sepse/epidemiologia , Urolitíase/cirurgia
4.
World J Urol ; 42(1): 310, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722553

RESUMO

INTRODUCTION: Ionizing radiation is used daily during endourological procedures. Despite the dangers of both deterministic and stochastic effects of radiation, there is a lack of knowledge and awareness among urologists. This study reviewed the literature to identify the radiation exposure (RE) of urologists during endourological procedures. METHODS: A literature search of the Medline, Web of Science, and Google Scholar databases was conducted to collect articles related to the radiation dose to urologists during endourological procedures. A total of 1966 articles were screened. 21 publications met the inclusion criteria using the PRIMA standards. RESULTS: Twenty-one studies were included, of which 14 were prospective. There was a large variation in the mean RE to the urologist between studies. PCNL had the highest RE to the urologist, especially in the prone position. RE to the eyes and hands was highest in prone PCNL, compared to supine PCNL. Wearing a thyroid shield and lead apron resulted in a reduction of RE ranging between 94.1 and 100%. Educational courses about the possible dangers of radiation decreased RE and increased awareness among endourologists. CONCLUSIONS: This is the first systematic review in the literature analyzing RE to urologists over a time period of more than four decades. Wearing protective garments such as lead glasses, a thyroid shield, and a lead apron are essential to protect the urologist from radiation. Educational courses on radiation should be encouraged to further reduce RE and increase awareness on the harmful effects of radiation, as the awareness of endourologists is currently very low.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Urologistas , Humanos , Urologia , Procedimentos Cirúrgicos Urológicos
5.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520528

RESUMO

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Assuntos
Iluminação , Ureteroscópios , Humanos , Desenho de Equipamento , Urologistas , Equipamentos Descartáveis , Ureteroscopia
6.
World J Urol ; 42(1): 355, 2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38796790

RESUMO

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Assuntos
Desenho de Equipamento , Iluminação , Ureteroscópios , Ureteroscopia , Luz , Humanos , Solução Salina , Cor
7.
World J Urol ; 42(1): 294, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38704777

RESUMO

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Assuntos
Ureteroscópios , Ureteroscopia , Humanos , Desenho de Equipamento , Iluminação , Maleabilidade , Cálices Renais
8.
World J Urol ; 42(1): 298, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38709327

RESUMO

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Assuntos
Desenho de Equipamento , Rim , Iluminação , Ureteroscópios , Modelos Anatômicos , Humanos
9.
World J Urol ; 42(1): 240, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630158

RESUMO

PURPOSE: To evaluate the impact of ureteroscope position within renal cavities as well as different locations of the tip of the ureteral access sheath (UAS) on fluid dynamics during retrograde intrarenal surgery (RIRS). MATERIALS AND METHODS: A prospective observational clinical study was performed. Measurements with a flexible ureteroscope placed in the upper, middle and lower calyces were obtained with the tip of the UAS placed either 2 cm below the pyelo-ureteric junction (PUJ), or at the level of the iliac crest. RESULTS: 74 patients were included. The outflow rates from the middle and upper calyxes were statistically significantly higher compared to the lower calyx, both with the UAS close to the pyelo-ureteric junction and at the iliac crest. When the UAS was withdrawn and positioned at the level of the iliac crest, a significant decrease in outflow rates from the upper (40.1 ± 4.3 ml/min vs 35.8 ± 4.1 ml/min) and middle calyces (40.6 ± 4.0 ml/min vs 36.8 ± 4.6 ml/min) and an increase in the outflow from the lower calyx (28.5 ± 3.3 ml/min vs 33.7 ± 5.7 ml/min) were noted. CONCLUSIONS: Our study showed that higher fluid outflow rates are observed from upper and middle calyces compared to lower calyx. This was true when the UAS was positioned 2 cm below the PUJ and at the iliac crest. Significant worsening of fluid dynamics from upper and middle calyces was observed when the UAS was placed distally at the level of the iliac crest. While the difference was statistically significant, the absolute change was not significant. In contrast, for lower calyces, a statistically significant improvement was documented.


Assuntos
Ureter , Ureteroscópios , Humanos , Hidrodinâmica , Rim , Endoscopia , Ureter/cirurgia
10.
World J Urol ; 42(1): 163, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488927

RESUMO

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Estudos Prospectivos , Exposição Ocupacional/prevenção & controle , Fluoroscopia/efeitos adversos , Exposição à Radiação/prevenção & controle , Doses de Radiação
11.
Turk J Med Sci ; 54(1): 185-193, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38812627

RESUMO

Background/aim: Management of asymptomatic kidney stones is an ongoing debate with follow-up and treatment guidelines based on low-level evidence. Our aim was to evaluate current management of asymptomatic urinary stones. Materials and methods: A 70-question survey was designed in collaboration with European Association of Urology, Young Academic Urologists, Section of Uro-Technology and Section of Urolithiasis groups and distributed. Responders filled out hypothetical scenarios from 2 perspectives, either as treating physicians, or as patients themselves. Results: A total of 212 (40.01%) responses were obtained. Median responder age was 39 years. 75% of responders were interested in "urolithiasis". 82.5% had never experienced a renal colic, 89.6% had never undergone urolithiasis treatment.Overall, as the kidney stone scenarios got more complicated, the invasiveness of the treatment preference increased. As "the physician", responders preferred the conservative option in all situations more than they would choose as "the patient". For ureteral stones, conservative approach was most preferred for small stones and ureteroscopy became more preferred as the stone size increased.For smaller kidney stones, the most preferred follow-up schedule was 4-6 monthly, whereas for larger and complicated stones it was 0-3 monthly from both perspectives respectively. For all ureteral stone scenarios, 0-4 weekly follow-up was mostly preferred.Interestingly, having had a renal colic was an independent predictor of an interventional approach, whereas having had an intervention was an independent predictor of a conservative approach. Conclusion: Current treatment and follow-up patterns of asymptomatic urinary stones are in agreement with international guidelines on symptomatic stones.In most of the urolithiasis situations urologists chose a conservative approach for their patients compared to what they would prefer for themselves. Conversely, urologists, in the scenarios as "the patient", would like to have a more frequent follow-up schedule for their stones compared to how they would follow-up their patients.


Assuntos
Urologistas , Humanos , Adulto , Inquéritos e Questionários , Masculino , Feminino , Urologia , Cálculos Renais/terapia , Ureteroscopia , Padrões de Prática Médica/estatística & dados numéricos , Urolitíase/terapia , Pessoa de Meia-Idade , Europa (Continente) , Atitude do Pessoal de Saúde , Doenças Assintomáticas/terapia
12.
World J Urol ; 41(2): 551-565, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36656331

RESUMO

PURPOSE: To evaluate the safety and efficacy of single-probe dual-energy (SPDE) lithotripters in patients undergoing percutaneous nephrolithotripsy (PCNL) through a systematic review and meta-analysis. METHODS: We searched PubMed, Cochrane Library, Scopus and Embase databases until July 2022 for any preclinical or clinical studies, exploring the safety and efficacy of different SPDE lithotripters in patients undergoing PCNL. We performed a meta-analysis to compare stone-free rate, bleeding, or other complications and mean operative time between SPDE lithotripters and other lithotripters (PROSPERO: CRD42021285631). RESULTS: We included 16 studies (six preclinical, seven observational and three randomized with 625 participants) in the systematic review and four in the meta-analysis. Preclinical studies suggest that SPDE lithotripters are safe and effective for the management of renal stones. Among clinical studies, four studies assessed Trilogy with no comparative arm, two compared Trilogy or ShockPulse with a dual-probe dual-energy lithotripter, two compared Trilogy with a laser, one compared ShockPulse with a pneumatic lithotripter, and one directly compared Trilogy with ShockPulse. Comparing SPDE lithotripters to other lithotripters, no significant differences were demonstrated in stone free rate (OR 1.13, 95% CI 0.53-2.38, I2 = 0%), postoperative blood transfusion (OR 1.33, 95% CI 0.34-5.19, I2 = 0%), embolization (OR 0.45, 95% CI 0.02-12.06), operative time (WMD: 2.82 min, 95% CI -7.31-12.95, I2 = 78%) and postoperative complications based on the Clavien-Dindo classification. CONCLUSIONS: SPDE lithotripters represent a promising treatment modality for patients requiring PCNL. Despite the initial encouraging findings of preclinical and isolated clinical studies, it seems that Trilogy or ShockPulse provide similar efficiency compared to older generation devices.


Assuntos
Cálculos Renais , Litotripsia , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Humanos , Nefrolitotomia Percutânea/efeitos adversos , Cálculos Renais/cirurgia , Litotripsia/efeitos adversos , Complicações Pós-Operatórias/etiologia , Duração da Cirurgia , Resultado do Tratamento
13.
World J Urol ; 41(10): 2823-2831, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37587366

RESUMO

PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. METHODS: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). RESULTS: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. CONCLUSION: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Urinários , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Poeira , Litotripsia a Laser/métodos , Cálculos Urinários/terapia
14.
World J Urol ; 41(12): 3723-3730, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37831156

RESUMO

BACKGROUND: The novel pulsed thulium:yttrium-aluminum-garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG ablation efficiency for stone dust from human urinary stones of known compositions. METHODS: Calcium oxalate monohydrate (COM) and uric acid (UA) stones were subjected to lithotripsy in vitro using a p-Tm:YAG laser generator (Thulio®, Dornier MedTech GmbH, Germany). 200 J was applied at 0.1 J × 100 Hz, 0.4 J × 25 Hz or 2.0 J × 5 Hz (average 10W). Ablated stone dust mass was calculated from weight difference between pre-lithotripsy stone and post-lithotripsy fragments > 250 µm. Estimated ablated volume was calculated using prior known stone densities (COM: 2.04 mg/mm3, UA: 1.55 mg/mm3). RESULTS: Mean ablation mass efficiency was 0.04, 0.06, 0.07 mg/J (COM) and 0.04, 0.05, 0.06 mg/J (UA) for each laser setting, respectively. This translated to 0.021, 0.029, 0.034 mm3/J (COM) and 0.026, 0.030, 0.039 mm3/J (UA). Mean energy consumption was 26, 18, 17 J/mg (COM) and 32, 23, 17 J/mg (UA). This translated to 53, 37, 34 J/mm3 (COM) and 50, 36, 26 J/mm3 (UA). There were no statistically significant differences for laser settings or stone types (all p > 0.05). CONCLUSION: To our knowledge, this is the first study showing ablation efficiency of the p-Tm:YAG laser for stone dust from human urinary stones of known compositions. The p-Tm:YAG seems to ablate COM and UA equally well, with no statistically significant differences between differing laser settings.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Nefrolitíase , Cálculos Urinários , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Litotripsia a Laser/métodos , Cálculos Urinários/terapia , Oxalato de Cálcio , Hólmio
15.
World J Urol ; 41(12): 3705-3711, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37855897

RESUMO

INTRODUCTION: The aims of the study: (1) to compare the Super Pulse Thulium Fiber Laser (SP TFL) and the holmium: yttrium-aluminium-garnet (Ho:YAG) lasers in retrograde intrarenal surgery (RIRS); (2) to compare the efficacy of SP TFL laser fibers of different diameters (150 µm and 200 µm). METHODS: A prospective randomized single-blinded trial was conducted. Patients with stones from 10 to 20 mm were randomly assigned RIRS in three groups: (1) SP TFL (NTO IRE-Polus, Russia) with fiber diameter of 150 µm; (2) SP TFL with 200-µm fiber; and (3) Ho:YAG (Lumenis, USA) with 200-µm fiber. RESULTS: Ninety-six patients with kidney stones were randomized to undergo RIRS with SP TFL using a 150-µm fiber (34 patients) and a 200-µm fiber (32 patients) and RIRS with Ho:YAG (30 patients). The median laser on time (LOT) in the 200-µm SP TFL group was 9.2 (6.2-14.6) min, in 150-µm SP TFL-11.4 (7.7-14.9) min (p = 0.390), in Ho:YAG-14.1 (10.8-18.1) min (p = 0.021). The total energy consumed in 200-µm SP TFL was 8.4 (5.8-15.2) kJ; 150-µm SP TFL - 10.8 (7.3-13.5) kJ (p = 0.626) and in Ho:YAG-15.2 (11.1-25.3) kJ (p = 0.005). CONCLUSIONS: Irrespective of the density, RIRS with SP TFL laser has proven to be both a safe and effective procedure. Whilst the introduction of smaller fibers may have the potential to reduce the duration of surgery, SP TFL results in a reduction in the LOT and total energy for stone ablation in RIRS compared with Ho:YAG.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Litotripsia a Laser/métodos , Túlio , Estudos Prospectivos , Cálculos Renais/cirurgia , Lasers de Estado Sólido/uso terapêutico , Hólmio
16.
World J Urol ; 41(11): 3301-3308, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37682286

RESUMO

INTRODUCTION: Several preclinical studies about a novel pulsed-thulium:yttrium-aluminum-garnet (p-Tm:YAG) device have been published, demonstrating its possible clinical relevance. METHODS: We systematically reviewed the reality and expectations for this new p-Tm:YAG technology. A PubMed, Scopus and Embase search were performed. All relevant studies and data identified in the bibliographic search were selected, categorized, and summarized. RESULTS: Tm:YAG is a solid state diode-pumped laser that emits at a wavelength of 2013 nm, in the infrared spectrum. Despite being close to the Ho:YAG emission wavelength (2120 nm), Tm:YAG is much closer to the water absorption peak and has higher absorption coefficient in liquid water. At present, there very few evaluations of the commercially available p-Tm:YAG devices. There is a lack of information on how the technical aspects, functionality and pulse mechanism can be maximized for clinical utility. Available preclinical studies suggest that p-Tm:YAG laser may potentially increase the ablated stone weight as compared to Ho:YAG under specific condition and similar laser parameters, showing lower retropulsion as well. Regarding laser safety, a preclinical study observed similar absolute temperature and cumulative equivalent minutes at 43° C as compared to Ho:YAG. Finally, laser-associated soft-tissue damage was assessed at histological level, showing similar extent of alterations due to coagulation and necrosis when compared with the other clinically relevant lasers. CONCLUSIONS: The p-Tm:YAG appears to be a potential alternative to the Ho:YAG and TFL according to these preliminary laboratory data. Due to its novelty, further studies are needed to broaden our understanding of its functioning and clinical applicability.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Temperatura , Água , Hólmio
17.
Curr Opin Urol ; 33(2): 90-94, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36622261

RESUMO

PURPOSE OF REVIEW: With advancements in surgical technology along with procedural techniques, this article throws light on the latest developments and applications of artificial intelligence (AI), extended reality, 3D (three-dimensional) printing and robotics in percutaneous nephrolithotomy (PCNL). RECENT FINDINGS: This review highlights the applications of AI in PCNL over the past 2 years. Mostly studies have been reported on development of machine learning (ML) based predicting models and identification of stone composition using deep learning convolutional neural network (DL-CNN). But owing to the complexity of the models and lack of generalizability, it is still not incorporated in the routine clinical practice. Extended reality based simulation and training models have enabled trainees to enhance their skills and shorten the learning curve. Similar advantages have been reported with the use of 3D printed models when used to train young and novice endourologists to improve their skills in percutaneous access (PCA). Applications of robotics in PCNL look promising but are still in nascent stages. SUMMARY: Future research on PCNL should focus more on generalizability and adaptability of technological advancements in terms of training and improvement of patient outcomes.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Urolitíase , Humanos , Nefrolitotomia Percutânea/efeitos adversos , Nefrolitotomia Percutânea/métodos , Urologistas , Inteligência Artificial , Urolitíase/cirurgia , Impressão Tridimensional , Cálculos Renais/cirurgia
18.
Curr Opin Urol ; 32(3): 330-338, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35256579

RESUMO

PURPOSE OF REVIEW: This review provides most recent findings and developments relating to surgical laser fibers, strippers, cleavers, and protective glasses. RECENT FINDINGS: The smallest core diameter that can be used with Holmium:YAG lasers is 200 µm. Smaller core diameter fibers can be used with the Thulium fiber laser and offer better flexibility and lower risk of fracture, at the risk of greater burnback effect. Misleading discrepancies between the true diameter of laser fibers and their packaging labels must be considered. Fiber tip degradation from the burnback occurs within few minutes, thus questioning the need for time-consuming fiber tip reprocessing with fiber strippers and special cleaving tools. This shortcoming also applies to instrument-protecting ball-tip fibers. Cleavage of fiber tips through their protective jackets ('coated tips') is a cheaper alternative for instrument protection, additionally offering better visual control of the fiber tip. Third-generation side-firing greenlight laser fibers are still prone to rapid deterioration. Laser eyewear does not seem necessary for Holmium:YAG applications, whereas laser-specific protective glasses should be worn for greenlight laser applications. SUMMARY: With better understanding of laser accessories, practicing urologists may tailor their practice to reach optimal efficacy and safety for Holmium:YAG, Thulium fiber laser and Greenlight laser applications.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Litotripsia a Laser , Hólmio , Humanos , Terapia a Laser/efeitos adversos , Lasers de Estado Sólido/uso terapêutico , Túlio
19.
J Cell Mol Med ; 25(16): 7890-7900, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34184816

RESUMO

Cytokeratin 5 is a marker of basal molecular subtypes of muscle-invasive bladder cancer (MIBC), which correlates with worse overall survival compared to luminal subtypes. Our observations have not confirmed CK5 as a marker of high-grade (HG) disease in Ta non-muscle-invasive bladder cancer (NMIBC). Therefore, to understand the basal-luminal immunohistochemistry profile in Ta NMIBC, we performed immunohistochemistry for CK5, P40, P63 (basal), GATA3 and CK20 (luminal) and studied the correlation with HG and clinical outcome in 109 patients with Ta NMIBC. HG and low-grade (LG) diseases were scored in each patient. Four different CK5 patterns were evaluated: absent (median 41.3%), normal (72.5%), rising (84.4%) and full thickness (23.9%). The median percentage of GATA3 was 100%. HG disease and CK5 expression and rising CK5 pattern had a significant inverse correlation, whereas HG disease and CK20 expression had a significant positive correlation. We also found a significant inverse correlation between CK5 expression and CK20 expression. Quantitative PCR confirmed that the presence of CK5 correlated with up-regulation of CK5 RNA. None of the markers could differentiate patients with regard to clinical outcome. Our results suggest a role for CK5 and CK20 in differentiating between LG and HG disease in Ta NMIBC.


Assuntos
Biomarcadores Tumorais/metabolismo , Queratina-5/metabolismo , Neoplasias da Bexiga Urinária/patologia , Idoso , Feminino , Humanos , Imuno-Histoquímica/métodos , Queratina-20/metabolismo , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Prognóstico , Estudos Retrospectivos , Neoplasias da Bexiga Urinária/metabolismo
20.
World J Urol ; 39(6): 1693-1698, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32363450

RESUMO

PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the thulium fiber laser (TFL) for lithotripsy. Where applicable, stone dust was further characterized by morpho-constitutional analysis. METHODS: Human urinary stones were submitted to in vitro lithotripsy using a FiberLase U2 TFL generator with 150 µm silica core fibers (IPG Photonics®, IPG Medical™, Marlborough, MA, USA). Laser settings were 0.05 J, 320 Hz and 200 µs. A total of 2400 J were delivered to each stone composition type. All evaluated stones had a > 90% degree of purity (calcium oxalate monohydrate, calcium oxalate dihydrate, uric acid, carbapatite, struvite, brushite and cystine). Spontaneously floating stone particles were considered as stone dust and collected for analysis by scanning electron microscopy and Fourier transform infrared spectroscopy. RESULTS: Stone dust could be retrieved from all evaluated urinary stones after TFL lithotripsy. Most stone dust samples revealed changes in crystalline organization, except for calcium oxalate monohydrate and carbapatite, which conserved their initial characteristics. Mean maximal width of stone dust particles did not exceed 254 µm. CONCLUSIONS: The TFL is capable to produce stone dust from all prevailing stone types. Morpho-constitutional changes found in stone dust suggest a photothermal interaction of laser energy with the stone matrix during TFL lithotripsy.


Assuntos
Litotripsia a Laser , Túlio/uso terapêutico , Cálculos Urinários/química , Cálculos Urinários/terapia , Poeira , Humanos , Técnicas In Vitro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA