Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(7)2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37050472

RESUMO

With the growing importance of single-photon-counting (SPC) techniques, researchers are now designing high-performance systems based on single-photon avalanche diodes (SPADs). SPADs with high performances and low cost allow the popularity of SPC-based systems for medical and industrial applications. However, few efforts were put into the design optimization of SPADs due to limited calibrated models of the SPAD itself and its related circuits. This paper provides a perspective on improving SPAD-based system design by reviewing the development of SPAD models. First, important SPAD principles such as photon detection probability (PDP), dark count rate (DCR), afterpulsing probability (AP), and timing jitter (TJ) are discussed. Then a comprehensive discussion of various SPAD models focusing on each of the parameters is provided. Finally, important research challenges regarding the development of more advanced SPAD models are summarized, followed by the outlook for the future development of SPAD models and emerging SPAD modeling methods.

2.
Small ; 18(1): e2101171, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34514693

RESUMO

Food wastage is a critical and world-wide issue resulting from an excess of food supply, poor food storage, poor marketing, and unstable markets. Since food quality depends on consumer standards, it becomes necessary to monitor the quality to ensure it meets those standards. Embedding sensors with active nanomaterials in food packaging enables customers to monitor the quality of their food in real-time. Though there are many different sensors that can monitor food quality and safety, pH sensors and time-temperature indicators (TTIs) are the most critical metrics in indicating quality. This review showcases some of the recent progress, their importance, preconditions, and the various future needs of pH sensors and TTIs in food packaging for smart sensors in food packaging applications. In discussing these topics, this review includes the materials used to make these sensors, which vary from polymers, metals, metal-oxides, carbon-based materials; and their modes of fabrication, ranging from thin or thick film deposition methods, solution-based chemistry, and electrodeposition. By discussing the use of these materials, novel fabrication process, and problems for the two sensors, this review offers solutions to a brighter future for the use of nanomaterials for pH indicator and TTIs in food packaging applications.


Assuntos
Embalagem de Alimentos , Nanoestruturas , Alimentos , Polímeros , Temperatura
3.
Sensors (Basel) ; 22(9)2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35591125

RESUMO

Coherent detection provides the optimum performance for free space optical (FSO) communication systems. However, such detection systems are expensive and require digital phase noise compensation. In this paper, the transmission performance of long-haul FSO system for ground-to-satellite communication based on a Kramers-Kronig (KK) transceiver is evaluated. KK transceivers utilize inexpensive direct detection receivers and the signal phase is retrieved from the received current using the well-known KK relations. KK transceivers are not sensitive to the laser phase noise and, hence, inexpensive lasers with large linewidths can be used at the transmitter. The transmission performance of coherent and KK transceivers is compared in various scenarios such as satellite-to-ground, satellite-to-satellite, and ground-to-satellite for weak, moderate, and strong turbulence. The results show that the transmission performance of a system based on the KK transceiver is comparable to that based on a coherent transceiver, but at a significantly lower system cost and complexity. It is shown that in the absence of turbulence, the coherent receiver has a ~3 dB performance advantage over the KK receiver. However, in the presence of strong turbulence, this performance advantage becomes negligible.

4.
Sensors (Basel) ; 22(2)2022 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-35062398

RESUMO

Wearable health monitoring devices allow for measuring physiological parameters without restricting individuals' daily activities, providing information that is reflective of an individual's health and well-being. However, these systems need to be accurate, power-efficient, unobtrusive and simple to use to enable a reliable, convenient, automatic and ubiquitous means of long-term health monitoring. One such system can be embedded in an insole to obtain physiological data from the plantar aspect of the foot that can be analyzed to gain insight into an individual's health. This manuscript provides a comprehensive review of insole-based sensor systems that measure a variety of parameters useful for overall health monitoring, with a focus on insole-based PPD measurement systems developed in recent years. Existing solutions are reviewed, and several open issues are presented and discussed. The concept of a fully integrated insole-based health monitoring system and considerations for future work are described. By developing a system that is capable of measuring parameters such as PPD, gait characteristics, foot temperature and heart rate, a holistic understanding of an individual's health and well-being can be obtained without interrupting day-to-day activities. The proposed device can have a multitude of applications, such as for pathology detection, tracking medical conditions and analyzing gait characteristics.


Assuntos
Sapatos , Dispositivos Eletrônicos Vestíveis , , Marcha , Humanos , Pressão
5.
Respir Res ; 22(1): 203, 2021 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-34243776

RESUMO

BACKGROUND: Thousands of Coronavirus Disease 2019 (COVID-19) patients have been discharged from hospitals Persistent follow-up studies are required to evaluate the prevalence of post-COVID-19 fibrosis. METHODS: This study involves 462 laboratory-confirmed patients with COVID-19 who were admitted to Shenzhen Third People's Hospital from January 11, 2020 to April 26, 2020. A total of 457 patients underwent thin-section chest CT scans during the hospitalization or after discharge to identify the pulmonary lesion. A total of 287 patients were followed up from 90 to 150 days after the onset of the disease, and lung function tests were conducted about three months after the onset. The risk factors affecting the persistence of pulmonary fibrosis were identified through regression analysis and the prediction model of the persistence of pulmonary fibrosis was established. RESULTS: Parenchymal bands, irregular interfaces, reticulation and traction bronchiectasis were the most common CT features in all COVID-19 patients. During the 0-30, 31-60, 61-90, 91-120 and > 120 days after onset, 86.87%, 74.40%, 79.56%, 68.12% and 62.03% patients developed with pulmonary fibrosis and 4.53%, 19.61%, 18.02%, 38.30% and 48.98% patients reversed pulmonary fibrosis, respectively. It was observed that Age, BMI, Fever, and Highest PCT were predictive factors for sustaining fibrosis even after 90 days from onset. A predictive model of the persistence with pulmonary fibrosis was developed based-on the Logistic Regression method with an accuracy, PPV, NPV, Sensitivity and Specificity of the model of 76%, 71%, 79%, 67%, and 82%, respectively. More than half of the COVID-19 patients revealed abnormal conditions in lung function after 90 days from onset, and the ratio of abnormal lung function did not differ on a statistically significant level between the fibrotic and non-fibrotic groups. CONCLUSIONS: Persistent pulmonary fibrosis was more likely to develop in patients with older age, higher BMI, severe/critical condition, fever, a longer viral clearance time, pre-existing disease and delayed hospitalization. Fibrosis developed in COVID-19 patients could be reversed in about a third of the patients after 120 days from onset. The pulmonary function of less than half of COVID-19 patients could turn to normal condition after three months from onset. An effective prediction model with an average area under the curve (AUC) of 0.84 was established to predict the persistence of pulmonary fibrosis in COVID-19 patients for early diagnosis.


Assuntos
COVID-19/virologia , Pulmão/virologia , Alta do Paciente , Fibrose Pulmonar/virologia , SARS-CoV-2/patogenicidade , Adolescente , Adulto , COVID-19/complicações , COVID-19/diagnóstico , China , Feminino , Interações Hospedeiro-Patógeno , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Fibrose Pulmonar/diagnóstico por imagem , Fibrose Pulmonar/fisiopatologia , Testes de Função Respiratória , Fatores de Tempo , Tomografia Computadorizada por Raios X , Adulto Jovem
6.
Analyst ; 146(8): 2626-2631, 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33656507

RESUMO

Free chlorine is widely used as a disinfectant in the water industry. Accurate monitoring of the residual free chlorine concentration in water cycles is critical to maintain public health safety. Here, we report on a thin gold film-based reusable and reagent-less free chlorine sensor. A gold thin film of 300 nm thickness was deposited on a polyimide tape, which was placed on a glass substrate and a simple Styrofoam adhesive tape was used to cover the film and expose 0.36 cm2 circular area as the sensing surface. The sensor showed a high sensitivity of 0.327 µA ppm-1, with a linear range of 0 to 6 ppm, and an accuracy of <0.1 ppm with high selectivity in the presence of commonly interfering ions. The sensor response time was 50 s with a negligible hysteresis of 0.06 ppm. The sensor showed very little change in output current in the pH range between 5.2 to 8.4, and temperature range of 20 to 30 °C. Therefore, the sensor operation is reagent-less, does not need frequent calibration, and showed consistent sensing performance with real water samples. The simple fabrication, ease-of-use and reliable sensing performance of the proposed sensor shows feasibility for mass-production and application in remote and resource-limited areas.

7.
Sensors (Basel) ; 21(11)2021 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-34072361

RESUMO

Multi-parameter water quality monitoring is crucial in resource-limited areas to provide persistent water safety. Conventional water monitoring techniques are time-consuming, require skilled personnel, are not user-friendly and are incompatible with operating on-site. Here, we develop a multi-parameter water quality monitoring system (MWQMS) that includes an array of low-cost, easy-to-use, high-sensitivity electrochemical sensors, as well as custom-designed sensor readout circuitry and smartphone application with wireless connectivity. The system overcomes the need of costly laboratory-based testing methods and the requirement of skilled workers. The proposed MWQMS system can simultaneously monitor pH, free chlorine, and temperature with sensitivities of 57.5 mV/pH, 186 nA/ppm and 16.9 mV/°C, respectively, as well as sensing of BPA with <10 nM limit of detection. The system also provides seamless interconnection between transduction of the sensors' signal, signal processing, wireless data transfer and smartphone app-based operation. This interconnection was accomplished by fabricating nanomaterial and carbon nanotube-based sensors on a common substrate, integrating these sensors to a readout circuit and transmitting the sensor data to an Android application. The MWQMS system provides a general platform technology where an array of other water monitoring sensors can also be easily integrated and programmed. Such a system can offer tremendous opportunity for a broad range of environmental monitoring applications.

8.
Sensors (Basel) ; 21(4)2021 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-33671571

RESUMO

Smart packaging of fresh produce is an emerging technology toward reduction of waste and preservation of consumer health and safety. Smart packaging systems also help to prolong the shelf life of perishable foods during transport and mass storage, which are difficult to regulate otherwise. The use of these ever-progressing technologies in the packaging of fruits has the potential to result in many positive consequences, including improved fruit quality, reduced waste, and associated improved public health. In this review, we examine the role of smart packaging in fruit packaging, current-state-of-the-art, challenges, and prospects. First, we discuss the motivation behind fruit quality monitoring and maintenance, followed by the background on the development process of fruits, factors used in determining fruit quality, and the classification of smart packaging technologies. Then, we discuss conventional freshness sensors for packaged fruits including direct and indirect freshness indicators. After that, we provide examples of possible smart packaging systems and sensors that can be used in monitoring fruits quality, followed by several strategies to mitigate premature fruit decay, and active packaging technologies. Finally, we discuss the prospects of smart packaging application for fruit quality monitoring along with the associated challenges and prospects.

9.
Anal Chem ; 92(7): 5532-5539, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32141295

RESUMO

Bisphenol A, an endocrine disrupting compound, is widely used in food and beverage packaging, and it then leaches in food and source water cycles, and thus must be monitored. Here, we report a simple, low-cost and sensitive electrochemical sensor using graphene oxide and ß-cyclodextrin functionalized multiwalled carbon nanotubes for the detection of BPA in water. This sensor electrode system combines the high surface area of graphene oxide and carbon nanotubes, and the superior host-guest interaction capability of ß-cyclodextrin. A diffusion-controlled oxidation reaction involving equal numbers of protons and electrons facilitated the electrochemical sensing of BPA. The sensor showed a two-step linear response from 0.05 to 5 µM and 5-30 µM with a limit of detection of 6 nM. The sensors also exhibited a reproducible and stable response over one month with negligible interference from common inorganic and organic species, and an excellent recovery with real water samples. The proposed electrochemical sensor can be promising for the development of simple low-cost water quality monitoring system for monitoring of BPA in water.


Assuntos
Compostos Benzidrílicos/análise , Compostos Benzidrílicos/química , Eletroquímica/instrumentação , Grafite/química , Nanotubos de Carbono/química , Fenóis/análise , Fenóis/química , beta-Ciclodextrinas/química , Eletrodos , Modelos Moleculares , Conformação Molecular
10.
Sensors (Basel) ; 19(9)2019 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-31075985

RESUMO

Over the past few decades, we have witnessed a dramatic rise in life expectancy owing to significant advances in medical science and technology, medicine as well as increased awareness about nutrition, education, and environmental and personal hygiene. Consequently, the elderly population in many countries are expected to rise rapidly in the coming years. A rapidly rising elderly demographics is expected to adversely affect the socioeconomic systems of many nations in terms of costs associated with their healthcare and wellbeing. In addition, diseases related to the cardiovascular system, eye, respiratory system, skin and mental health are widespread globally. However, most of these diseases can be avoided and/or properly managed through continuous monitoring. In order to enable continuous health monitoring as well as to serve growing healthcare needs; affordable, non-invasive and easy-to-use healthcare solutions are critical. The ever-increasing penetration of smartphones, coupled with embedded sensors and modern communication technologies, make it an attractive technology for enabling continuous and remote monitoring of an individual's health and wellbeing with negligible additional costs. In this paper, we present a comprehensive review of the state-of-the-art research and developments in smartphone-sensor based healthcare technologies. A discussion on regulatory policies for medical devices and their implications in smartphone-based healthcare systems is presented. Finally, some future research perspectives and concerns regarding smartphone-based healthcare systems are described.


Assuntos
Smartphone , Tecnologia Biomédica/métodos , Atenção à Saúde/métodos , Humanos , Monitorização Ambulatorial , Telemedicina/métodos
11.
Sensors (Basel) ; 19(22)2019 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-31744258

RESUMO

Positron emission tomography (PET) imaging is an essential tool in clinical applications for the diagnosis of diseases due to its ability to acquire functional images to help differentiate between metabolic and biological activities at the molecular level. One key limiting factor in the development of efficient and accurate PET systems is the sensor technology in the PET detector. There are generally four types of sensor technologies employed: photomultiplier tubes (PMTs), avalanche photodiodes (APDs), silicon photomultipliers (SiPMs), and cadmium zinc telluride (CZT) detectors. PMTs were widely used for PET applications in the early days due to their excellent performance metrics of high gain, low noise, and fast timing. However, the fragility and bulkiness of the PMT glass tubes, high operating voltage, and sensitivity to magnetic fields ultimately limit this technology for future cost-effective and multi-modal systems. As a result, solid-state photodetectors like the APD, SiPM, and CZT detectors, and their applications for PET systems, have attracted lots of research interest, especially owing to the continual advancements in the semiconductor fabrication process. In this review, we study and discuss the operating principles, key performance parameters, and PET applications for each type of sensor technology with an emphasis on SiPM and CZT detectors-the two most promising types of sensors for future PET systems. We also present the sensor technologies used in commercially available state-of-the-art PET systems. Finally, the strengths and weaknesses of these four types of sensors are compared and the research challenges of SiPM and CZT detectors are discussed and summarized.

12.
Sensors (Basel) ; 19(9)2019 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-31083397

RESUMO

Brain-inspired intelligence using the cognitive dynamic system (CDS) concept is proposed to control the quality-of-service (QoS) over a long-haul fiber-optic link that is nonlinear and with non-Gaussian channel noise. Digital techniques such as digital-back-propagation (DBP) assume that the fiber optic link parameters, such as loss, dispersion, and nonlinear coefficients, are known at the receiver. However, the proposed CDS does not need to know about the fiber optic link physical parameters, and it can improve the bit error rate (BER) or enhance the data rate based on information extracted from the fiber optic link. The information extraction (Bayesian statistical modeling) using intelligent perception processing on the received data, or using the previously extracted models in the model library, is carried out to estimate the transmitted data in the receiver. Then, the BER is sent to the executive through the main feedback channel and the executive produces actions on the physical system/signal to ensure that the BER is continuously under the forward-error-correction (FEC) threshold. Therefore, the proposed CDS is an intelligent and adaptive system that can mitigate disturbance in the fiber optic link (especially in an optical network) using prediction in the perceptor and/or doing proper actions in the executive based on BER and the internal reward. A simplified CDS was implemented for nonlinear fiber optic systems based on orthogonal frequency division multiplexing (OFDM) to show how the proposed CDS can bring noticeable improvement in the system's performance. As a result, enhancement of the data rate by 12.5% and the Q-factor improvement of 2.74 dB were achieved in comparison to the conventional system (i.e., the system without smart brain).

13.
Sensors (Basel) ; 19(11)2019 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-31185629

RESUMO

The world's population is aging: the expansion of the older adult population with multiple physical and health issues is now a huge socio-economic concern worldwide. Among these issues, the loss of mobility among older adults due to musculoskeletal disorders is especially serious as it has severe social, mental and physical consequences. Human body joint monitoring and early diagnosis of these disorders will be a strong and effective solution to this problem. A smart joint monitoring system can identify and record important musculoskeletal-related parameters. Such devices can be utilized for continuous monitoring of joint movements during the normal daily activities of older adults and the healing process of joints (hips, knees or ankles) during the post-surgery period. A viable monitoring system can be developed by combining miniaturized, durable, low-cost and compact sensors with the advanced communication technologies and data processing techniques. In this study, we have presented and compared different joint monitoring methods and sensing technologies recently reported. A discussion on sensors' data processing, interpretation, and analysis techniques is also presented. Finally, current research focus, as well as future prospects and development challenges in joint monitoring systems are discussed.


Assuntos
Articulações/fisiologia , Monitorização Fisiológica , Movimento/fisiologia , Dispositivos Eletrônicos Vestíveis , Idoso , Fenômenos Biomecânicos , Feminino , Corpo Humano , Humanos , Amplitude de Movimento Articular
14.
Opt Express ; 26(2): 963-979, 2018 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-29401984

RESUMO

A computationally efficient time-resolved diffuse optical tomography (TR-DOT) prototype was demonstrated using an accelerated inverse problem solver to reconstruct high quality 3D images of highly scattering media such as tissues. The inverse problem solver utilizes seven well-defined points on each experimentally recorded histogram of the distribution time-of-flight (DToF). In this work, the accuracy of the recovered optical properties, and the computational load and time of TR-DOT prototype were investigated using cylindrical turbid phantoms. These phantoms were measured using transmittance geometry under different conditions in multiple experiments to evaluate the performance of this prototype. Overall, the results of evaluation are important in the realization of a real-time and highly accurate TR-DOT system for diffuse optical imaging applications.

15.
Sensors (Basel) ; 18(11)2018 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-30380688

RESUMO

Time-resolved diffuse optical spectroscopy (TR-DOS) is an increasingly used method to determine the optical properties of diffusive media, particularly for medical applications including functional brain, breast and muscle measurements. For medical imaging applications, important features of new generation TR-DOS systems are low-cost, small size and efficient inverse modeling. To address the issues of low-cost, compact size and high integration capabilities, we have developed free-running (FR) single-photon avalanche diodes (SPADs) using 130 nm silicon complementary metal-oxide-semiconductor (CMOS) technology and used it in a TR-DOS prototype. This prototype was validated using assessments from two known protocols for evaluating TR-DOS systems for tissue optics applications. Following the basic instrumental performance protocol, our prototype had sub-nanosecond total instrument response function and low differential non-linearity of a few percent. Also, using light with optical power lower than the maximum permissible exposure for human skin, this prototype can acquire raw data in reflectance geometry for phantoms with optical properties similar to human tissues. Following the MEDPHOT protocol, the absolute values of the optical properties for several homogeneous phantoms were retrieved with good accuracy and linearity using a best-fitting model based on the Levenberg-Marquardt method. Overall, the results of this study show that our silicon CMOS-based SPAD detectors can be used to build a multichannel TR-DOS prototype. Also, real-time functional monitoring of human tissue such as muscles, breasts and newborn heads will be possible by integrating this detector with a time-to-digital converter (TDC).


Assuntos
Custos e Análise de Custo , Óptica e Fotônica/economia , Óptica e Fotônica/instrumentação , Fótons , Análise Espectral , Humanos , Dinâmica não Linear , Imagens de Fantasmas , Fatores de Tempo
16.
Sensors (Basel) ; 17(9)2017 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-28906462

RESUMO

Diffuse optical spectroscopy (DOS) and diffuse optical imaging (DOI) are emerging non-invasive imaging modalities that have wide spread potential applications in many fields, particularly for structural and functional imaging in medicine. In this article, we review time-resolved diffuse optical imaging (TR-DOI) systems using solid-state detectors with a special focus on Single-Photon Avalanche Diodes (SPADs) and Silicon Photomultipliers (SiPMs). These TR-DOI systems can be categorized into two types based on the operation mode of the detector (free-running or time-gated). For the TR-DOI prototypes, the physical concepts, main components, figures-of-merit of detectors, and evaluation parameters are described. The performance of TR-DOI prototypes is evaluated according to the parameters used in common protocols to test DOI systems particularly basic instrumental performance (BIP). In addition, the potential features of SPADs and SiPMs to improve TR-DOI systems and expand their applications in the foreseeable future are discussed. Lastly, research challenges and future developments for TR-DOI are discussed for each component in the prototype separately and also for the entire system.

17.
Sensors (Basel) ; 17(1)2017 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-28085085

RESUMO

Life expectancy in most countries has been increasing continually over the several few decades thanks to significant improvements in medicine, public health, as well as personal and environmental hygiene. However, increased life expectancy combined with falling birth rates are expected to engender a large aging demographic in the near future that would impose significant  burdens on the socio-economic structure of these countries. Therefore, it is essential to develop cost-effective, easy-to-use systems for the sake of elderly healthcare and well-being. Remote health monitoring, based on non-invasive and wearable sensors, actuators and modern communication and information technologies offers an efficient and cost-effective solution that allows the elderly to continue to live in their comfortable home environment instead of expensive healthcare facilities. These systems will also allow healthcare personnel to monitor important physiological signs of their patients in real time, assess health conditions and provide feedback from distant facilities. In this paper, we have presented and compared several low-cost and non-invasive health and activity monitoring systems that were reported in recent years. A survey on textile-based sensors that can potentially be used in wearable systems is also presented. Finally, compatibility of several communication technologies as well as future perspectives and research challenges in remote monitoring systems will be discussed.


Assuntos
Monitorização Fisiológica , Atenção à Saúde , Humanos , Telemedicina , Têxteis , Dispositivos Eletrônicos Vestíveis
18.
Sensors (Basel) ; 17(11)2017 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-29088123

RESUMO

Advancements in medical science and technology, medicine and public health coupled with increased consciousness about nutrition and environmental and personal hygiene have paved the way for the dramatic increase in life expectancy globally in the past several decades. However, increased life expectancy has given rise to an increasing aging population, thus jeopardizing the socio-economic structure of many countries in terms of costs associated with elderly healthcare and wellbeing. In order to cope with the growing need for elderly healthcare services, it is essential to develop affordable, unobtrusive and easy-to-use healthcare solutions. Smart homes, which incorporate environmental and wearable medical sensors, actuators, and modern communication and information technologies, can enable continuous and remote monitoring of elderly health and wellbeing at a low cost. Smart homes may allow the elderly to stay in their comfortable home environments instead of expensive and limited healthcare facilities. Healthcare personnel can also keep track of the overall health condition of the elderly in real-time and provide feedback and support from distant facilities. In this paper, we have presented a comprehensive review on the state-of-the-art research and development in smart home based remote healthcare technologies.


Assuntos
Serviços de Assistência Domiciliar , Idoso , Atenção à Saúde , Humanos , Telemedicina
19.
Anal Chem ; 88(21): 10384-10389, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27669977

RESUMO

The concentration of free chlorine used for disinfecting drinking water, recreational water, and food processing water is critical for environmental and human health conditions, and should be controlled within stipulated ranges. This report, for the first time, describes a paper-based electrochemical free chlorine sensor fabricated by hand-drawing. The electrical resistivity of a poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) chemoresistor increases when it is exposed to free chlorine in water due to oxidation reactions. Because the relative change of the electrical resistance represents the sensor's response, the sensor can be fabricated by hand-drawing with different shapes and dimensions. The fabrication steps are all at room temperature, require no instrumentation or equipment, and can be carried out by untrained personnel. The fabricated sensor is mechanically stable, reusable, has a wide sensing range, and can accurately measure free chlorine concentrations in real water samples. Therefore, the low-cost, hand-drawn free chlorine sensor is of great significance for water quality monitoring in less developed areas where fabrication facilities, analytical equipment, and trained personnel are limited, but the need for analytical devices is critical. In addition to the free chlorine sensor demonstrated in this study, other types of PEDOT:PSS-based sensors and electronic devices can be fabricated by the developed hand-drawing process.

20.
Anal Chem ; 87(21): 10734-7, 2015 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-26457368

RESUMO

Pencil lead was used to fabricate a graphite-based electrode for sensing applications. Its surface was electrochemically modified using ammonium carbamate to make it suitable for sensing free chlorine in water samples. Chlorine is widely used as a disinfectant in the water industry, and the residual free chlorine concentration in water distributed to the consumers must be lower than that stipulated by regulatory bodies. The graphite-based amperometric sensor gave a selective and linear response to free chlorine in the relevant concentration range and no response to commonly interfering ions. It was evaluated further for storage stability, response time, and hysteresis. This sensor is being proposed as a low-cost device for determining free chlorine in water samples. Its ease-of-use, limitations, and feasibility for mass-production and application is discussed.


Assuntos
Cloro/análise , Técnicas Eletroquímicas/economia , Técnicas Eletroquímicas/instrumentação , Grafite/química , Cloro/química , Eletrodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA