Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 31(1): 144-149, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31778266

RESUMO

BACKGROUND: A two-incision technique, in association with inter-muscular positioning of the subcutaneous defibrillator (S-ICD), is now the most frequently adopted implantation approach in Europe. Ultrasound-guided serratus anterior plane block (SAPB) has been proposed to provide anesthesia/analgesia during S-ICD implantation. OBJECTIVE: We performed a case-control analysis in which a standardized SAPB approach was compared with the typical local anesthesia and sedation approach. METHODS: Ninety-one consecutive patients underwent implantation of an S-ICD with the SAPB approach for anesthesia/analgesia at 10 centers. The control group consisted of 55 consecutive patients who underwent S-ICD implantation with a standard local approach. RESULTS: The mean procedure duration was 59 ± 15 minutes in the SAPB group and 76 ± 23 minutes in the control group (P < .001). No operative complications were reported in either group. During the procedure, 79 (87%) patients in the SAPB group and 25 (46%) patients in the control group (P < .001) remained awake. Lower values of pain intensity at the device pocket (P = .005) and the lateral tunneling site (P = .046) were reported in the SAPB group. The difference in static (P = .002) and dynamic (P = .007) pain intensity between the groups persisted at 1 hour, while no differences were observed 6 hours after the end of the procedure. CONCLUSIONS: SAPB is feasible and effective in providing anesthesia/analgesia during S-ICD implantation. The procedures were successfully accomplished and no complications occurred in either group. However, SAPB was associated with lower pain levels, enabling the need for sedation to be reduced and more patients to remain awake. Moreover, it resulted in shorter procedure durations.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Músculo Esquelético/inervação , Bloqueio Nervoso , Dor Pós-Operatória/prevenção & controle , Implantação de Prótese/instrumentação , Adulto , Idoso , Estudos de Casos e Controles , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Bloqueio Nervoso/efeitos adversos , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Implantação de Prótese/efeitos adversos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
J Cardiovasc Pharmacol ; 76(2): 138-145, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32453074

RESUMO

Coronavirus disease 2019 (COVID-19) outbreak is a public health emergency of international concerns because of a highly pathogenic human coronavirus (HCoV), actually named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Despite much emerging data about the epidemiological association between cardiovascular diseases and COVID-19, little is still known about atrial fibrillation and its optimal management in this clinical contest. The aim of our review is to describe the pharmacological interactions between cardiovascular drugs more commonly used in atrial fibrillation management and experimental COVID-19 therapies, based on EU and US summaries of product characteristics.


Assuntos
Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Antivirais/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Betacoronavirus/efeitos dos fármacos , Infecções por Coronavirus/tratamento farmacológico , Pneumonia Viral/tratamento farmacológico , Antiarrítmicos/efeitos adversos , Antiarrítmicos/farmacocinética , Anticoagulantes/efeitos adversos , Anticoagulantes/farmacocinética , Antivirais/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Betacoronavirus/patogenicidade , COVID-19 , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/virologia , Interações Medicamentosas , Interações Hospedeiro-Patógeno , Humanos , Pandemias , Pneumonia Viral/diagnóstico , Pneumonia Viral/epidemiologia , Pneumonia Viral/virologia , Fatores de Risco , SARS-CoV-2 , Resultado do Tratamento , Tratamento Farmacológico da COVID-19
3.
Acta Myol ; 33(2): 104-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25709381

RESUMO

We report the case of a 32-year-old man with Myotonic Dystrophy type 1 showing adenosine-induced sinus tachycardia during transesophageal electrophysiological evaluation.


Assuntos
Adenosina/efeitos adversos , Antiarrítmicos/efeitos adversos , Distrofia Miotônica/complicações , Distrofia Miotônica/fisiopatologia , Taquicardia Sinusal/induzido quimicamente , Adulto , Técnicas Eletrofisiológicas Cardíacas , Humanos , Masculino
4.
Acta Myol ; 32(3): 142-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24803841

RESUMO

The role that atrial pacing therapy plays on the atrial fibrillation (AF) burden is still unclear. Aim of the study was to evaluate the effect of the atrial preference pacing algorithm on AF burden in patients affected by Myotonic Dystrophy type 1 (DM1) followed for a long follow up period. Sixty DM1 patients were -implanted with a dual chamber pacemaker (PM) for first degree or symptomatic type 1/type 2 second degree atrio-ventricular blocks- were followed for 2-years after implantation, by periodical examination. After 1 month of stabilization, they were randomized into two groups: 1) Patients implanted with conventional dual-chamber pacing mode (DDDR group) and 2) Patients implanted with DDDR plus Atrial Preference Pacing (APP) algorithm (APP ON group). The results showed that atrial tachycardia (AT)/AF burden was significantly reduced at 1 year follow up in the APP ON group (2122 ± 428 minutes vs 4127 ± 388 minutes, P = 0.03), with a further reduction at the end of the 2 year follow up period (4652 ± 348 minutes vs 7564 ± 638 minutes, P = 0.005). The data here reported show that the APP is an efficient algorithm to reduce AT/AF burden in DM1 patients implanted with dual chamber pacemaker.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Distrofia Miotônica/fisiopatologia , Algoritmos , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
5.
J Invasive Cardiol ; 35(10)2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37984324

RESUMO

BACKGROUND: Right heart catheterization (RHC) usually is performed via the femoral vein or the internal jugular vein. However, the antecubital fossa vein is a valid venous access, and it has become increasingly popular to perform right heart catheterization utilizing this access. METHODS: A retrospective, observational study was conducted to describe use of the antecubital fossa vein for right heart catheterization in adults and children with congenital heart disease (CHD). Patients who had undergone RHC via antecubital fossa vein at the authors' hospital between September 2019 and December 2022 were included. The outcomes studied were procedural failure and procedure-related adverse events. RESULTS: Fifty-two patients with CHD underwent right cardiac catheterization via an upper arm vein. The upper arm vein was unable to perform the RHC in only 2 patients (3.8%). Only 1 patient developed a minor adverse event. No irreversible and/or life-threating adverse events were detected. CONCLUSIONS: The upper arm veins are safe and effective to perform a RHC in children and adults with CHD. This approach demonstrates a high percentage of technical success, and few mild complications.


Assuntos
Cateterismo Venoso Central , Cardiopatias Congênitas , Humanos , Adulto , Criança , Braço , Estudos Retrospectivos , Estudos de Viabilidade , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Cateterismo Cardíaco/efeitos adversos , Veias Jugulares , Veia Femoral
6.
Europace ; 14(4): 486-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22135319

RESUMO

AIMS: Atrial Preference Pacing (APP) is a pacemaker (PM) algorithm that supports a continuous atrial stimulation instead of a spontaneous atrial rhythm to prevent supraventricular tachyarrhythmias. The role of the APP in the prevention of atrial fibrillation (AF) is still controversial. The aim of our study was to evaluate the effect of preventive atrial pacing on AF incidence in myotonic dystrophy type I patients during a 12-month follow-up period. METHODS AND RESULTS: We studied 40 patients with myotonic dystrophy type 1 (MD1) who underwent dual-chamber PM implantation for first- and second-degree atrioventricular block. After a 1-month stabilization period, they were randomized to APP algorithm programmed OFF or ON for 6 months each, using a cross-over design. The number of AF episodes during active treatment (APP ON phases) was lower than those registered during no treatment (APP OFF phases). No statistically significant difference was found in AF episodes duration between the two phases. During the APP OFF phases and APP ON phases, the atrial pacing percentage was 0 and 98%, respectively, while the ventricular pacing percentage did not show statistically significant difference (10 vs. 8%, P =0.2). Atrial premature beats count was significantly greater during APP OFF phases than during APP ON phases. Lead parameters remained stable over time and there were no lead-related complications. CONCLUSIONS: Based on these 12-month follow-up data, it is concluded that APP is an efficacy algorithm for preventing paroxysmal AF in MD1 patients who underwent dual-chamber PM implantation for atrioventricular conduction disorders.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Distrofia Miotônica/complicações , Distrofia Miotônica/terapia , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
7.
Europace ; 12(9): 1219-23, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20538830

RESUMO

AIMS: Paroxysmal atrial arrhythmias occur in myotonic dystrophy type 1 (MD1) patients frequently. Pacemaker (PM) including detailed diagnostic functions may facilitate the diagnosis and management of frequent paroxysmal atrial tachyarrhythmias that may remain undetected during conventional clinical follow-up. Aim of our study was to evaluate the preventive effects of interatrial septum pacing in the Bachmann's Bundle region on atrial fibrillation (AF) in MD1 patients during 12 months follow up period. METHODS AND RESULTS: Thirty MD1 patients (age 50.3 +/- 7.3; 11 F) who underwent dual chamber PM implantation were randomized at implantation to receive right atrial appendage pacing (16 patients) or Bachmann's bundle pacing (14 patients). No statistically significant difference in the electrical parameters (P wave amplitude, pacing threshold and lead impedance) was found between the two groups at implantation. Patients were followed at 1 month, 3 months, and every 6 months thereafter. They underwent clinical assessment, a standard 12-lead ECG and assessment of device performance at every visit. We counted the number of episodes of atrial arrhythmia occurred during the collection period and the duration of each episode. At 12 months of follow-up, no statistically significant differences in the number of AF episodes or in AF duration were found. Lead parameters remained stable over time and there were no displacements of the electrodes after implantation. CONCLUSION: Implantation of an atrial-active fixation lead on the atrial septum is safe and feasible. However, this study showed no significant difference between septal pacing and high atrial pacing, using the endpoints of AF duration and number of AF episodes.


Assuntos
Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Distrofia Miotônica/terapia , Apêndice Atrial/inervação , Apêndice Atrial/fisiopatologia , Septo Interatrial/inervação , Septo Interatrial/fisiopatologia , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Pacing Clin Electrophysiol ; 32(9): 1191-6, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19719498

RESUMO

AIM: We performed a two-year follow-up comparative study of long-term electrical parameters between the right atrial appendage (RAA) and Bachmann's Bundle (BB) stimulation in myotonic dystrophy type 1 (MD1) patients. METHODS: Twenty-five MD1 patients (18 men; age: 54 +/- 13 years) with no difference in the electrical parameters between the RAA site and the BB region at implantation were randomized into two groups: in group I (13 patients; age: 52 +/- 14 years; four women) the atrial lead was placed in the RAA and in group II (12 patients, age: 56 +/- 12 years, three women) the lead was placed in the BB region. Measurements of electrical parameters were recorded at follow-up intervals of 6 weeks and then 12 and 24 months postimplant. RESULTS: There was no statistically significant different in P-wave amplitude, pacing threshold, and impedance values between the two groups at 6 weeks. At 24 months follow-up, the intrinsic P-wave amplitude was 2.05 +/- 1.45 mV in the RAA group versus 3.28 +/- 1.09 mV in the BB group (P < 0.05); the pacing threshold was 1.85 +/- 1.8 V in the RAA group versus 0.50 +/- 0.39 V in the BB group (P = 0.03); there were no differences in the atrial impedance between the two groups during the follow-up period. CONCLUSIONS: In a direct two-year follow-up comparison between the RAA and BB atrial pacing sites, we showed a statistically significant increased pacing threshold and decreased intrinsic P-wave amplitude during RAA stimulation in MD1 patients.


Assuntos
Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Distrofia Miotônica/diagnóstico , Distrofia Miotônica/terapia , Eletrocardiografia , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
9.
J Investig Med ; 59(7): 1151-4, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22011621

RESUMO

BACKGROUND: Paroxysmal episodes of atrial fibrillation frequently occur in Emery-Dreifuss muscular dystrophy (EDMD). Although previous studies have documented a variety of electrocardiographic abnormalities in EDMD, little is still known about P-wave dispersion (PD), an independent risk factor for the development of atrial fibrillation. The aim of our study was to evaluate the P-wave duration and PD in patients with EDMD with conserved systolic and diastolic cardiac function. METHODS: The study involved 36 patients with EDMD (age, 20 [SD, 12] years; 26 men) and 36 healthy subjects used as controls, matched for age and sex. P-wave dispersion was carefully measured using 12-lead electrocardiogram. Compared with the healthy control group, patients with EDMD presented increased maximum P-wave duration (108.2 [SD, 22.2] vs 97.8 [SD, 11] milliseconds, P = 0.04) and PD (51.4 [SD, 12.8] vs 39.3 [SD, 9.7] milliseconds, P = 0.004) values. No statistically significant differences in left atrium diameter (37.1 [SD, 2.9] vs 34.1 [SD, 4.2] mm, P = 0.3) and maximum left atrium volume (15.2 [SD, 3.8] vs 14.1 [SD, 4.2] mL/m2, P = 0.4) were found between the 2 groups. We divided our study population into 2 subgroups, according to the different genetic diagnosis, patients with laminopathy EDMD (n = 17) or with emerinopathy EDMD (n = 19). No statistically significant differences were found in PD between the 2 subgroups (54.6 [SD, 15.6] vs 50.2 [SD, 11.5] milliseconds, P = 0.4). CONCLUSIONS: Our study showed a significant increase of maximum P-wave duration and PD in patients with EDMD with conserved systolic and diastolic cardiac function.


Assuntos
Eletrocardiografia/métodos , Distrofia Muscular de Emery-Dreifuss/fisiopatologia , Adulto , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Índice de Massa Corporal , Estudos de Casos e Controles , Diástole , Feminino , Marcadores Genéticos , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Distrofia Muscular de Emery-Dreifuss/complicações , Risco , Fatores de Risco , Sístole , Fatores de Tempo
10.
Anadolu Kardiyol Derg ; 10(2): 126-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20382610

RESUMO

OBJECTIVE: Atrioventricular nodal reentrant tachycardia (AVNRT) accounts for about 60% of the patients presenting with paroxysmal supraventricular tachycardia. The radiofrequency (RF) catheter ablation of the slow atrioventricular (AV) node pathway is the preferred therapeutic approach in patients with AV node reentrant tachycardia. The aim of our study was describe the electrophysiological properties of successful slow pathway RF ablation in patients with common atrioventricular nodal reentrant tachycardia. METHODS: The study design was a retrospective analysis involving fifty consecutive patients (18 males; mean age of 39+/-22 years) who underwent slow pathway ablation because of AVNRT. RESULTS: Slow junctional beats with a cycle length longer than 550 ms were observed in 39 patients (79%); the presence of rapid junctional beats with a cycle length less than 550 ms was showed in 5 patients (10%). Moreover, in 32 of 50 patients (65%) duration of atrial electrogram more than 40 ms was noticed. Analyzing data reported, we found the statistically significant presence of slow junctional beats (p=0.001) and atrial electrogram >40 ms (p=0.05) in successful RF ablation procedures. CONCLUSION: In patients with AVNRT undergoing slow pathway ablation, the duration of atrial electrogram >40 ms and slow junctional beats with cycle length >550 ms during the application of RF energy describe the electrophysiological properties of successful slow pathway RF ablation.


Assuntos
Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca/fisiologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adulto , Arritmias Cardíacas , Nó Atrioventricular/fisiopatologia , Nó Atrioventricular/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Taquicardia Ectópica de Junção/etiologia , Resultado do Tratamento
11.
Neuromuscul Disord ; 20(3): 174-7, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20149661

RESUMO

We report the case of 14-year-old boy with X-linked Emery-Dreifuss muscular dystrophy who developed sick sinus syndrome and required placement of an implantable intracardiac cardioverter-defibrillator (ICD) to prevent sudden death. He demonstrated no significant risk factors for sudden death such as depressed left ventricular ejection fraction, or spontaneous or inducible ventricular tachycardia. One month after implantation, the patient experienced one appropriate ICD discharge.


Assuntos
Cardiomiopatias/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Distrofia Muscular de Emery-Dreifuss/complicações , Adolescente , Cardiomiopatias/patologia , Eletrocardiografia , Humanos , Masculino , Síndrome do Nó Sinusal/etiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA