Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 22(9): 313-323, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34291861

RESUMO

PURPOSE: The aim of this study is to propose an algorithm for the automated calculation of water-equivalent diameter (Dw ) and size-specific dose estimation (SSDE) from clinical computed tomography (CT) images containing one or more substantial body part. METHODS: All CT datasets were retrospectively acquired by the Toshiba Aquilion 128 CT scanner. The proposed algorithm consisted of a contouring stage for the Dw calculation, carried out by taking the six largest objects in the cross-sectional image of the patient's body, followed by the removal of the CT table depending on the center position (y-axis) of each object. Validation of the proposed algorithm used images of patients who had undergone chest examination with both arms raised up, one arm placed down and both arms placed down, images of the pelvic region consisting of one substantial object, and images of the lower extremities consisting of two separated areas. RESULTS: The proposed algorithm gave the same results for Dw and SSDE as the previous algorithm when images consisted of one substantial body part. However, when images consisted of more than one substantial body part, the new algorithm was able to detect all parts of the patient within the image. The Dw values from the proposed algorithm were 9.5%, 15.4%, and 39.6% greater than the previous algorithm for the chest region with one arm placed down, both arms placed down, and images with two legs, respectively. The SSDE values from the proposed algorithm were 8.2%, 11.2%, and 20.6% lower than the previous algorithm for the same images, respectively. CONCLUSIONS: We have presented an improved algorithm for automated calculation of Dw and SSDE. The proposed algorithm is more general and gives accurate results for both Dw and SSDE whether the CT images contain one or more than one substantial body part.


Assuntos
Tomografia Computadorizada por Raios X , Água , Humanos , Pelve , Doses de Radiação , Estudos Retrospectivos
2.
Radiat Prot Dosimetry ; 196(3-4): 248-256, 2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34580737

RESUMO

The study aims to correlate the effective diameter (Deff) and water-equivalent diameter (Dw) parameters with anterior-posterior (AP), lateral (LAT) and AP + LAT dimensions in order to estimate the patient dose in head CT examinations. Seventy-four patient datasets from head CT examinations were retrospectively collected. The patient's sizes were calculated from the middle slice using a software of IndoseCT. Dw and Deff were plotted as functions of AP, LAT and AP + LAT dimensions. The best trendline fit for LAT and AP functions was a second order polynomial, which resulted in R2 of 0.89 for Deff vs LAT, 0.88 for Dw vs LAT, 0.92 for Deff vs AP and 0.91 for Dw vs AP. A linear correlation was found for Deff vs AP + LAT, Dw vs AP + LAT and Dw vs Deff with R2 of 0.97, 0.96 and 0.98, respectively.


Assuntos
Cabeça , Água , Cabeça/diagnóstico por imagem , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA