Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Platelets ; 32(4): 560-567, 2021 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-33270471

RESUMO

The aim of this study (NCT04343053) is to investigate the relationship between platelet activation, myocardial injury, and mortality in patients affected by Coronavirus disease 2019 (COVID-19). Fifty-four patients with respiratory failure due to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection were enrolled as cases. Eleven patients with the same clinical presentation, but negative for SARS-CoV-2 infection, were included as controls. Blood samples were collected at three different time points (inclusion [T1], after 7 ± 2 days [T2] and 14 ± 2 days [T3]). Platelet aggregation by light transmittance aggregometry and the circulating levels of soluble CD40 ligand (sCD40L) and P-selectin were measured. Platelet biomarkers did not differ between cases and controls, except for sCD40L which was higher in COVID-19 patients (p = .003). In COVID-19 patients, P-selectin and sCD40L levels decreased from T1 to T3 and were higher in cases requiring admission to intensive care unit (p = .004 and p = .008, respectively). Patients with myocardial injury (37%), as well as those who died (30%), had higher values of all biomarkers of platelet activation (p < .05 for all). Myocardial injury was an independent predictor of mortality. In COVID-19 patients admitted to hospital for respiratory failure, heightened platelet activation is associated with severity of illness, myocardial injury, and mortality.ClinicalTrials.gov number: NCT04343053.


Assuntos
Plaquetas/metabolismo , COVID-19 , Traumatismos Cardíacos , Miocárdio , Insuficiência Respiratória , SARS-CoV-2/metabolismo , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Ligante de CD40/sangue , COVID-19/sangue , COVID-19/mortalidade , COVID-19/patologia , Feminino , Traumatismos Cardíacos/sangue , Traumatismos Cardíacos/mortalidade , Traumatismos Cardíacos/patologia , Traumatismos Cardíacos/virologia , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Miocárdio/patologia , Selectina-P/sangue , Agregação Plaquetária , Insuficiência Respiratória/sangue , Insuficiência Respiratória/mortalidade , Insuficiência Respiratória/patologia , Insuficiência Respiratória/virologia
2.
Open Heart ; 11(1)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485286

RESUMO

BACKGROUND: The diagnosis of myocardial infarction (MI) in the presence of heart failure (HF) presents a clinical problem. While diagnostic algorithms using high-sensitivity cardiac troponin have been established for suspected MI, their accuracy in patients with HF remains uncertain. This study aims to assess the diagnostic accuracy of high-sensitivity troponin I (TnI) levels in identifying acute MI among patients with HF, focusing on baseline, absolute and relative TnI changes. METHODS: Data from 562 individuals admitted to the emergency department with suspected MI were retrospectively analysed. Two-point TnI and baseline brain natriuretic peptide (BNP) test results were available. HF status was determined based on clinical, laboratory and instrumental criteria. RESULTS: Among the 562 patients, 299 (53.2%) were confirmed having MI. Baseline TnI demonstrated predictive capability for MI in the overall population (area under the curve (AUC) 0.63), while TnI relative change exhibited superior performance (AUC 0.83). Baseline TnI accuracy varied significantly by group, notably decreasing in the third group (severe HF) (AUC 0.54) compared with the first and second groups (AUC 0.67 and AUC 0.71, respectively). TnI relative change demonstrated consistent accuracy across all groups, with AUCs of 0.79, 0.79 and 0.89 for the first, second and third groups, respectively, even after adjustment for age, sex and glomerular filtration rate. DISCUSSION: Troponin relative change is a reliable predictor of MI, even in patients with acute HF. Baseline TnI accuracy is influenced by HF severity. It is essential to consider HF status and BNP levels when employing high-sensitivity cardiac troponin testing to rule out suspected MIs.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Humanos , Troponina I , Estudos Retrospectivos , Biomarcadores , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/epidemiologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia
3.
Intern Emerg Med ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652232

RESUMO

We aimed to develop and validate a COVID-19 specific scoring system, also including some ECG features, to predict all-cause in-hospital mortality at admission. Patients were retrieved from the ELCOVID study (ClinicalTrials.gov identifier: NCT04367129), a prospective, multicenter Italian study enrolling COVID-19 patients between May to September 2020. For the model validation, we randomly selected two-thirds of participants to create a derivation dataset and we used the remaining one-third of participants as the validation set. Over the study period, 1014 hospitalized COVID-19 patients (mean age 74 years, 61% males) met the inclusion criteria and were included in this analysis. During a median follow-up of 12 (IQR 7-22) days, 359 (35%) patients died. Age (HR 2.25 [95%CI 1.72-2.94], p < 0.001), delirium (HR 2.03 [2.14-3.61], p = 0.012), platelets (HR 0.91 [0.83-0.98], p = 0.018), D-dimer level (HR 1.18 [1.01-1.31], p = 0.002), signs of right ventricular strain (RVS) (HR 1.47 [1.02-2.13], p = 0.039) and ECG signs of previous myocardial necrosis (HR 2.28 [1.23-4.21], p = 0.009) were independently associated to in-hospital all-cause mortality. The derived risk-scoring system, namely EL COVID score, showed a moderate discriminatory capacity and good calibration. A cut-off score of ≥ 4 had a sensitivity of 78.4% and 65.2% specificity in predicting all-cause in-hospital mortality. ELCOVID score represents a valid, reliable, sensitive, and inexpensive scoring system that can be used for the prognostication of COVID-19 patients at admission and may allow the earlier identification of patients having a higher mortality risk who may be benefit from more aggressive treatments and closer monitoring.

4.
EuroIntervention ; 18(12): 977-986, 2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36093795

RESUMO

BACKGROUND: The ACURATE neo2 (NEO2) and Evolut PRO/PRO+ (PRO) bioprostheses are new-generation self-expanding valves developed for transcatheter aortic valve replacement (TAVR). AIMS: We sought to compare the performance of the ACURATE neo2 and Evolut PRO/PRO+ devices. METHODS: The NEOPRO-2 registry retrospectively included patients who underwent TAVR for severe aortic stenosis with either the NEO2 or PRO devices between August 2017 and December 2021 at 20 centres. In-hospital and 30-day Valve Academic Research Consortium (VARC)-3 defined outcomes were evaluated. Propensity score (PS) matching and binary logistic regression were performed to adjust the treatment effect for PS quintiles. A subgroup analysis assessed the impact of aortic valve calcification. RESULTS: A total of 2,175 patients (NEO2: n=763; PRO: n=1,412) were included. The mean age was 82±6.2 years and the mean Society of Thoracic Surgeons score was 4.2%. Periprocedural complications were low, and both groups achieved high rates of technical success (93.1% vs 94.1%; p=0.361) and predischarge intended valve performance (96.0% vs 94.1%; p=0.056), both in the unmatched and matched analysis (452 pairs). Device success at 30 days was comparable (84.3% vs 83.6%; p=0.688), regardless of aortic valve calcification severity (p>0.05 for interaction). A suggestion for higher VARC-3 early safety in the NEO2 group was mainly driven by reduced rates of new permanent pacemaker implantation (7.7% vs 15.6%; p<0.001). CONCLUSIONS: This retrospective analysis reports a similar short-term performance of the ACURATE neo2 platform compared with the new-generation Evolut PRO/PRO+ devices. Randomised studies are needed to confirm our exploratory findings.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37480891

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Incidência , Bloqueio de Ramo , Prognóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649387

RESUMO

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese , Fatores de Risco
7.
J Cardiovasc Med (Hagerstown) ; 23(10): 672-677, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36099074

RESUMO

AIMS: This meta-analysis aims to compare direct oral anticoagulants (DOACs) versus vitamin K antagonists (VKAs) in the setting of left ventricular thrombosis (LVT). METHOD AND RESULTS: We systematically searched MEDLINE, Cochrane Library, Biomed Central and Web of Science for trials comparing DOACs versus VKAs in the setting of LVT and reporting outcome data on thrombosis resolution, stroke and bleeding. Fourteen studies were finally selected. The Mantel-Haenszel method with a random effect model was used for the pooled analysis. The primary outcome was the occurrence of LVT resolution. The secondary outcomes were the occurrence of stroke or bleeding during treatment. One thousand three hundred and thirty-two patients were included in the analysis for the primary outcome. Of these, 424 were treated with DOACs and 908 with VKAs. The pooled odds ratio (OR) for the primary outcome was 1.00 [95% confidence interval (95% CI) 0.77-1.31, I2 0.0%], reflecting equal effect in terms of thrombus resolution. Overall, 2290 patients, 608 on DOACs and 1682 on VKAs were included in the analysis of stroke occurrence, showing reduced risk of events in patients treated with DOACs (pooled OR 0.58, 95% CI 0.36-0.93; I2 0.0%) as well as for bleeding occurrence (number of patients included 2139; pooled OR 0.64, 95% CI 0.44-0.94; I2 0.0%). CONCLUSION: Compared with VKAs, we found DOACs to have similar efficacy on thrombus resolution and favorable effects on stroke reduction and bleedings. DOACs should be considered as an alternative treatment for LVT. Large prospective randomized clinical trials are needed to confirm this exploratory finding.


Assuntos
Cardiopatias , Acidente Vascular Cerebral , Trombose , Administração Oral , Anticoagulantes , Fibrinolíticos/uso terapêutico , Cardiopatias/tratamento farmacológico , Hemorragia/epidemiologia , Humanos , Estudos Prospectivos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/prevenção & controle , Trombose/induzido quimicamente , Trombose/tratamento farmacológico , Trombose/prevenção & controle
8.
ESC Heart Fail ; 9(3): 2037-2043, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35318819

RESUMO

AIMS: This study aims to investigate the role of echocardiographically determined left ventricular output indices on sacubitril/valsartan titration in a cohort of outpatients with heart failure and reduced ejection fraction (HFrEF). METHODS AND RESULTS: We analysed 106 HFrEF patients who underwent echocardiography examination up to 1 week before starting treatment with sacubitril/valsartan. For each patient, a comprehensive list of clinical and laboratory parameters was collected, and stroke volume index (SVi), cardiac index, and flow rate were calculated. The primary endpoint was the occurrence of complete titration of sacubitril/valsartan. The secondary endpoint was the incidence of adverse events (hypotension and renal adverse events). Univariate and multivariate logistic regression were used to identify variables associated with the primary and secondary endpoints. Mean age of patients was 73.7 ± 10.4 years, 72 patients (71.7%) had ischaemic aetiology of HF, and mean ejection fraction was 29.4 ± 5.9%. At multivariate analysis, SVi [odds ratio (OR) 1.43 per 5 mL/m2 increase, 95% confidence interval (CI) 1.03-1.97; P = 0.028], serum sodium (OR 1.18, 95% CI 1.02-1.37; P = 0.022), and haemoglobin (OR 1.73, 95% CI 1.25-2.40; P = 0.001) were found to be independent predictors of titration during follow-up. Multivariate analysis for the secondary endpoint showed SVi (OR 0.63 per 5 mL/m2 increase, 95% CI 0.44-0.90; P = 0.012) and New York Heart Association Class III (OR 2.65, 95% CI 1.07-6.5; P = 0.034) to be associated with hypotension. CONCLUSIONS: Stroke volume index is positively associated with complete titration of sacubitril/valsartan. Patients with low SVi are more prone to experience hypotension during titration.


Assuntos
Insuficiência Cardíaca , Hipotensão , Disfunção Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Aminobutiratos , Compostos de Bifenilo , Humanos , Hipotensão/induzido quimicamente , Hipotensão/tratamento farmacológico , Pessoa de Meia-Idade , Volume Sistólico , Valsartana/uso terapêutico , Disfunção Ventricular Esquerda/tratamento farmacológico
9.
ESC Heart Fail ; 9(1): 263-269, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34755468

RESUMO

Recent data support the existence of a distinctive 'vascular' phenotype with the involvement of both pulmonary parenchyma and its circulation in COVID-19 pneumonia. Its prompt identification is important for the accurate management of COVID-19 patients. The aim is to analyse the pro and contra of the different modalities to identify the 'vascular' phenotype. Chest computed tomography scan and angiogram may quantify both parenchyma and vascular damage, but the presence of thrombosis of pulmonary microcirculation may be missed. Increased d-dimer concentration confirms a thrombotic state, but it cannot localize the thrombus. An elevation of troponin concentration non-specifically reflects cardiac injury. Echocardiogram and electrocardiogram provide specific signs of right ventricular pressure overload. This is particularly relevant for the 'vascular' phenotype, which does not necessarily represent the result of thrombo-embolic venous complications, but more frequently, it is the result of pulmonary microcirculation thrombosis in situ and needs immediate therapeutic action. CONDENSED ABSTRACT: Despite diagnosis of the 'vascular' phenotype of COVID-19 pneumonia may be subtle, the evidence indicates a reasonable possibility of identifying it already in the initial stage of the infection. Chest computed tomography scan and angiogram, increased d-dimer concentration, and elevation of troponin concentration may be not sufficient to identify 'vascular' phenotype. Echocardiogram and electrocardiogram provide specific signs of right ventricular pressure overload. This is particularly relevant for the 'vascular' phenotype, which does not necessarily represent the result of thrombo-embolic venous complications, but more frequently, it is the result of pulmonary microcirculation thrombosis in situ and needs immediate therapeutic action.


Assuntos
COVID-19 , Trombose , Humanos , Pulmão , Fenótipo , SARS-CoV-2
10.
Eur J Heart Fail ; 24(8): 1377-1386, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35417089

RESUMO

AIM: To investigate the prevalence of amyloid cardiomyopathy (AC) and the diagnostic accuracy of echocardiographic red flags of AC among consecutive adult patients undergoing transthoracic echocardiogram for reason other than AC in 13 Italian institutions. METHODS AND RESULTS: This is an Italian prospective multicentre study, involving a clinical and instrumental work-up to assess AC prevalence among patients ≥55 years old with an echocardiogram suggestive of AC (i.e. at least one echocardiographic red flag of AC in hypertrophic, non-dilated left ventricles with preserved ejection fraction). The study was registered at ClinicalTrials.gov (NCT04738266). Overall, 381 patients with an echocardiogram suggestive of AC were identified among a cohort of 5315 screened subjects, and 217 patients completed the investigations. A final diagnosis of AC was made in 62 patients with an estimated prevalence of 29% (95% confidence interval 23%-35%). Transthyretin-related AC (ATTR-AC) was diagnosed in 51 and light chain-related AC (AL-AC) in 11 patients. Either apical sparing or a combination of ≥2 other echocardiographic red flags, excluding interatrial septum thickness, provided a diagnostic accuracy >70%. CONCLUSION: In a cohort of consecutive adults with echocardiographic findings suggestive of AC and preserved left ventricular ejection fraction, the prevalence of AC (either ATTR or AL) was 29%. Easily available echocardiographic red flags, when combined together, demonstrated good diagnostic accuracy.


Assuntos
Amiloidose , Cardiomiopatias , Insuficiência Cardíaca , Amiloidose/diagnóstico , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/epidemiologia , Humanos , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA