Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Med Humanit ; 49(2): 272-277, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36600592

RESUMO

Since its debut, Mary Shelley's Frankenstein has, fittingly, assumed a life of its own. In today's cultural landscape, the mere mention of 'mutant' evokes the language of Othering, including Frankensteinian metaphors, such as those used to describe the omicron variant of SARS-CoV-2. When scientists referred to omicron as a Frankenstein variant, they demonstrated the inherent mutability of the myth-a myth that is crucial in biomedicine. In this article, the authors examine the shifting nature of Frankenstein metaphors and consider how they function in what Priscilla Wald refers to as outbreak narratives in the context of the USA's COVID-19 policies. The authors point to the ready instatement of travel bans as evidence of how such a potent myth is used to create and sell public policy. In response to such xenophobic policies, the authors apply Donna Haraway's concept of 'boundary breakdowns' in order to reimagine relationships with mutancy. They examine how moving past the idea of mutant is other in contemporary virus narratives may offer a way to reconfigure our relationships of self and other and move beyond the hegemonic and nativist policies of the present.


Assuntos
COVID-19 , Medicina na Literatura , Humanos , Metáfora , SARS-CoV-2
3.
Fertil Steril ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38631505

RESUMO

OBJECTIVE: To study the development and clinical validation of the ART Pipetting Robot for the IVF Laboratory (APRIL), a liquid-handling robot customized for the precise preparation of microdroplet culture dishes in the field of in vitro fertilization (IVF). DESIGN: A prospective randomized study conducted at an academic IVF center comparing mouse and human embryo outcomes and quantitative measures of accuracy in embryo dishes prepared using APRIL compared with standard manual preparation. SETTING: Academic IVF center. SUBJECTS: The study involved the assessment of the automated culture dish preparation system, APRIL, compared with manual preparation methods in the context of IVF treatment. INTERVENTION: ART Pipetting Robot for the IVF Laboratory is an enclosed liquid-handling robot equipped with custom three-dimensional-printed adapters and designed to dispense embryo culture media and mineral oil into microdroplet culture dishes. MAIN OUTCOME MEASURES: The study evaluated the precision and consistency of APRIL in culture dish preparation by looking at droplet mass, pH of prepared media droplets, and mouse and human embryo development rates. Clinical implementation was assessed by comparing embryo development and outcomes in dishes prepared by APRIL and human embryologists. RESULTS: Compared with embryo culture dishes prepared using standard manual procedures, embryo culture dishes prepared using APRIL demonstrated a greater than 10-fold improvement in consistency (coefficient of variation, 0.46% vs. 6%-7%), maintained optimal pH levels (pH range, 7.281-7.33 vs. 7.275-7.311), and had a greater mouse embryo blastocyst rate (100% vs. 90%-91%). Human embryos cultured in dishes prepared by APRIL had a higher rate of development on days 3 (92.4% vs. 82.6%) and 5 (19.75% vs. 15.57%), and a total number of usable embryos (50.3% vs. 46.1%) compared with manually prepared dishes, although the last two outcomes did not reach statistical significance. CONCLUSION: The results suggest that the use of an automated robotic system for preparation of embryo culture dishes may improve accuracy and outcome measures while reducing the need for trained laboratory personnel to prepare the dishes manually.

4.
Sci Rep ; 11(1): 2402, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33510181

RESUMO

The COVID-19 pandemic has resulted in an urgent need for a rapid, point of care diagnostic testing that could be rapidly scaled on a worldwide level. We developed and tested a highly sensitive and robust assay based on reverse transcription loop mediated isothermal amplification (RT-LAMP) that uses readily available reagents and a simple heat block using contrived spike-in and actual clinical samples. RT-LAMP testing on RNA-spiked samples showed a limit of detection (LoD) of 2.5 copies/µl of viral transport media. RT-LAMP testing directly on clinical nasopharyngeal swab samples in viral transport media had an 85% positive percentage agreement (PPA) (17/20), and 100% negative percentage agreement (NPV) and delivered results in 30 min. Our optimized RT-LAMP based testing method is a scalable system that is sufficiently sensitive and robust to test for SARS-CoV-2 directly on clinical nasopharyngeal swab samples in viral transport media in 30 min at the point of care without the need for specialized or proprietary equipment or reagents. This cost-effective and efficient one-step testing method can be readily available for COVID-19 testing world-wide, especially in resource poor settings.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/isolamento & purificação , SARS-CoV-2/genética , Técnicas de Laboratório Clínico/métodos , Técnicas e Procedimentos Diagnósticos , Testes Diagnósticos de Rotina , Humanos , Limite de Detecção , Testes Imediatos , RNA Viral/genética , Transcrição Reversa , SARS-CoV-2/química , SARS-CoV-2/metabolismo , Sensibilidade e Especificidade
5.
Sci Rep ; 11(1): 5448, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33750853

RESUMO

To safely re-open economies and prevent future outbreaks, rapid, frequent, point-of-need, SARS-CoV-2 diagnostic testing is necessary. However, existing field-deployable COVID-19 testing methods require the use of uncomfortable swabs and trained providers in PPE, while saliva-based methods must be transported to high complexity laboratories for testing. Here, we report the development and clinical validation of High-Performance Loop-mediated isothermal Amplification (HP-LAMP), a rapid, saliva-based, SARS-CoV-2 test with a limit of detection of 1.4 copies of virus per µl of saliva and a sensitivity and specificity with clinical samples of > 96%, on par with traditional RT-PCR based methods using swabs, but can deliver results using only a single fluid transfer step and simple heat block. Testing of 120 patient samples in 40 pools comprised of 5 patient samples each with either all negative or a single positive patient sample was 100% accurate. Thus, HP-LAMP may enable rapid and accurate results in the field using saliva, without need of a high-complexity laboratory.


Assuntos
COVID-19/diagnóstico , SARS-CoV-2/genética , Saliva/virologia , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19 , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular , Nasofaringe/virologia , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/metabolismo , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Temperatura
6.
medRxiv ; 2020 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-32577685

RESUMO

The COVID-19 pandemic has resulted in an urgent global need for rapid, point-of-care diagnostic testing. Existing methods for nucleic acid amplification testing (NAAT) require an RNA extraction step prior to amplification of the viral RNA. This step necessitates the use of a centralized laboratory or complex and costly proprietary cartridges and equipment, and thereby prevents low-cost, scalable, point-of-care testing. We report the development of a highly sensitive and robust, easy-to-implement, SARS-CoV-2 test that utilizes isothermal amplification and can be run directly on viral transport media following a nasopharyngeal swab without the need for prior RNA extraction. Our assay provides visual results in 30 min with 85% sensitivity, 100% specificity, and a limit of detection (LoD) of 2.5 copies/µl, and can be run using a simple heat block.

7.
medRxiv ; 2020 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-32587984

RESUMO

Rapid, scalable, point-of-need, COVID-19 diagnostic testing is necessary to safely re-open economies and prevent future outbreaks. We developed an assay that detects single copies of SARS-CoV-2 virus directly from saliva and swab samples in 30 min using a simple, one-step protocol that utilizes only a heat block and microcentrifuge tube prefilled with a mixture containing the necessary reagents and has a sensitivity and specificity of 97% and 100%, respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA