Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Sep Sci ; 35(18): 2390-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22997029

RESUMO

In this study, the mass transport resistance in liquid-phase microextraction (LPME) in a single hollow fiber was investigated. A mathematical model has been developed for the determination of the overall mass transfer coefficient based on the acceptor phase in an unsteady state. The overall mass transfer coefficient in LPME in a single hollow fiber has been estimated from time-dependent concentration of extracted analyte in the acceptor phase while maintaining a constant analyte concentration in the donor phase. It can be achieved either using a high volume of donor to acceptor phase ratio or tuning the extraction conditions to obtain a low-enrichment factor, so that the analyte concentration in the sample is not significantly influenced by the mass transfer. Two extraction systems have been used to test experimentally the developed model: the extraction of Lu(III) from a buffer solution and the extraction of three local anesthetics from a buffer or plasma solution. The mass transfer resistance, defined as a reciprocal values of the mass transfer coefficient, was found to be 1.2 × 10(3) cm(-1) min for Lu(III) under optimal conditions and from 1.96 to 3.3 × 10(3) cm(-1) min for the local anesthetics depending on the acceptor pH and the hydrophobicity of the drug.


Assuntos
Microextração em Fase Líquida , Lutécio/análise , Concentração de Íons de Hidrogênio , Porosidade , Propriedades de Superfície
2.
J Sep Sci ; 33(13): 2002-9, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20506430

RESUMO

Transport behaviour of Lu(III) across a polypropylene hollow fibre-supported liquid membrane containing di(2-ethylhexyl)phosphoric acid (DEHPA) in dihexyl ether as a carrier has been studied. The donor phase was LuCl(3) in the buffer solution consisting of 0.2 M sodium acetate at pH 2.5-5.0. A miniaturised system with a single hollow fibre has been operated in a batch mode. The concentration of Lu(III) was determined by indirect voltammetric method using Zn-EDTA complex. The effect of pH and volume of the donor phase, DEHPA concentration in the organic (liquid membrane) phase, the time of extraction and the content of the acceptor phase on the Lu(III) extraction and stripping behaviour was investigated. The results were discussed in terms of the pertraction and removal efficiency, the memory effect and the mean flux of Lu(III). The optimal conditions for the removal of (177)Lu(III) from labelled (177)Lu-radiopharmaceuticals were discussed and identified. The removal efficiency of Lu(III) greater than 99% was achieved at pH of the donor phase between 3.5 and 5.0 using DEHPA concentration in the organic phase of 0.47 M and the ratio of the donor to the acceptor phase of 182.


Assuntos
Lutécio/isolamento & purificação , Membranas Artificiais , Organofosfatos/química , Concentração de Íons de Hidrogênio , Soluções , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA