Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Am Coll Emerg Physicians Open ; 5(3): e13187, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38846102

RESUMO

This article provides a report of a case of organ dysfunction, myonecrosis, rhabdomyolysis, multifocal ischemic cerebral infarcts, and cerebral edema after a patient's use of xylazine and fentanyl. Within the US opioid epidemic, xylazine is emerging as a troubling national sub-story. The prevalence of xylazine within illicitly manufactured opioids and the proportion of opioid-involved overdose deaths with detected xylazine are rising dramatically, the latter increasing 276% between 2019 and 2022. A 27-year-old woman with opioid use disorder, active intravenous drug use, and prior bacteremia presented to our institution's emergency department (ED) with left lower extremity pain and associated weakness, new acute bilateral hearing loss, multiple electrolyte derangements, and cerebral infarcts followed by cerebral edema, leading to an emergent sub-occipital decompressive craniectomy and placement of an external ventricular drain. A definitive mechanism was not determined; however, we hypothesized that xylazine toxicity played a role in her clinical presentation, which could have future clinical implications, including the possibility to incorporate xylazine as part of toxicology screens.

2.
Am J Vet Res ; : 1-8, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38113642

RESUMO

OBJECTIVE: To investigate the mechanisms underlying the improved arterial oxygenation described with flow-limited expiration (FLEX) ventilation in anesthetized horses. ANIMALS: 5 healthy adult research horses. METHODS: Horses underwent volume-controlled ventilation for 60 minutes (VCV1), followed by 60 minutes of FLEX, and 30 minutes of VCV (VCV2). Main outcomes included the arterial partial pressure of oxygen-to-Fio2 (PF) ratio and electrical impedance tomography (EIT)-derived functional indices at the end of each phase. The EIT data were used to create regional maps of relative lung ventilation and perfusion as well as regional maps of ventilation/perfusion (V/Q) ratios. Ventilation indices derived from EIT included the fraction of expired volume in 1 second (FEV1; %) and the time it took for the EIT signal to drop to 50% of the peak signal at end-inspiration (TClose50; seconds). Data were analyzed with 2-way ANOVA for repeated measures. P < .05 was considered significant. RESULTS: The PF ratio increased significantly with FLEX compared to both VCV1 and VCV2 (P < .01). There were no differences in the relative distribution of ventilation nor perfusion between ventilation strategies. However, when ventilation and perfusion were superimposed and V/Q ratio maps were constructed, FLEX had a homogenizing effect toward values of 1.0. The FEV1 was shorter (P < .01) and the TClose50 was longer (P < .001) in all regions during FLEX compared to both VCV1 and VCV2. CLINICAL RELEVANCE: Our findings suggest that FLEX ventilation in anesthetized horses enhances regional V/Q matching, likely by prolonging expiratory aeration and reducing airway closure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA