Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 202
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 62(5): 881-890, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37999931

RESUMO

OBJECTIVES: Blood microsampling, particularly dried blood spots (DBSs), is an attractive minimally-invasive approach that is well suited for home sampling and predictive medicine associated with longitudinal follow-up of the elderly. However, in vitro diagnostic quantification of biomarkers from DBS poses a major challenge. Clinical mass spectrometry can reliably quantify blood proteins in various research projects. Our goal here was to use mass spectrometry of DBS in a real-world clinical setting and compared it to the standard immunoassay method. We also sought to correlate DBS mass spectrometry measurements with clinical indices. METHODS: A clinical trial of diagnostic equivalence was conducted to compare conventional venous samples quantified by immunoassay and DBSs quantified by mass spectrometry in an elderly population. We assayed three protein biomarkers of nutritional and inflammatory status: prealbumin (transthyretin), C-reactive protein, and transferrin. RESULTS: The analysis of DBSs showed satisfactory variability and low detection limits. Statistical analysis confirmed that the two methods give comparable results at clinical levels of accuracy. In conclusion, we demonstrated, in a real-life setting, that DBSs can be used to measure prealbumin, CRP and transferrin, which are commonly used markers of nutritional status and inflammation in the elderly. However, there was no correlation with patient frailty for these proteins. CONCLUSIONS: Early detection and regular monitoring of nutritional and inflammatory problems using DBS appear to be clinically feasible. This could help resolve major public health challenges in the elderly for whom frailty leads to serious risks of health complications.


Assuntos
Fragilidade , Pré-Albumina , Idoso , Humanos , Espectrometria de Massas em Tandem/métodos , Biomarcadores , Teste em Amostras de Sangue Seco/métodos , Transferrinas
2.
Ren Fail ; 45(2): 2292152, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38078385

RESUMO

Tubular injury is the main cause of acute kidney injury (AKI) in critically ill COVID-19 patients. Proximal tubular dysfunction (PTD) and changes in urinary biomarkers, such as NGAL, TIMP-2, and IGFBP7 product ([TIMP-2]•[IGFBP7]), could precede AKI. We conducted a prospective cohort study from 2020/03/09 to 2020/05/03, which consecutively included all COVID-19 patients who had at least one urinalysis, to assess the incidence of PTD and AKI, and the effectiveness of PTD, NGAL, and [TIMP-2]•[IGFBP7] in AKI and persistent AKI prediction using the area under the receiver operating characteristic curves (AUCs), Kaplan-Meier methodology (log-rank tests), and Cox models. Among the 60 patients admitted to the ICU with proven COVID-19 (median age: 63-year-old (interquartile range: IQR, 55-74), 45 males (75%), median simplified acute physiology score (SAPS) II: 34 (IQR, 22-47) and median BMI: 25.7 kg/m2 (IQR, 23.3-30.8)) analyzed, PTD was diagnosed in 29 patients (48%), AKI in 33 (55%) and persistent AKI in 20 (33%). Urinary NGAL had the highest AUC for AKI prediction: 0.635 (95%CI: 0.491-0.779) and persistent AKI prediction: 0.681 (95%CI: 0.535-0.826), as compared to PTD and [TIMP-2]•[IGFBP7] (AUCs <0.6). AKI was independently associated with higher SAPSII (HR = 1.04, 95%CI: 1.01-1.06, p = 0.005) and BMI (HR = 1.07, 95%CI: 1.00-1.14, p = 0.04) and persistent AKI with higher SAPSII (HR = 1.03, 95%CI: 1.00-1.06, p = 0.048) and nephrotoxic drug use (HR = 3.88, 95%CI: 1.20-12.5, p = 0.02). In conclusion, in critically ill COVID-19 patients, the incidence of PTD and AKI was relatively high. NGAL was the best urinary biomarker for predicting AKI, but only clinical severity was independently associated with its occurrence.


Assuntos
Injúria Renal Aguda , COVID-19 , Masculino , Humanos , Pessoa de Meia-Idade , Inibidor Tecidual de Metaloproteinase-2 , Estudos Prospectivos , Estado Terminal , Lipocalina-2 , COVID-19/complicações , Rim , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Biomarcadores
3.
Int J Mol Sci ; 24(8)2023 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-37108152

RESUMO

Blood microsampling combined with large panels of clinically relevant tests are of major interest for the development of home sampling and predictive medicine. The aim of the study was to demonstrate the practicality and medical utility of microsamples quantification using mass spectrometry (MS) in a clinical setting by comparing two types of microsamples for multiplex MS protein detection. In a clinical trial based on elderly population, we compared 2 µL of plasma to dried blood spot (DBS) with a clinical quantitative multiplex MS approach. The analysis of the microsamples allowed the quantification of 62 proteins with satisfactory analytical performances. A total of 48 proteins were significantly correlated between microsampling plasma and DBS (p < 0.0001). The quantification of 62 blood proteins allowed us to stratify patients according to their pathophysiological status. Apolipoproteins D and E were the best biomarker link to IADL (instrumental activities of daily living) score in microsampling plasma as well as in DBS. It is, thus, possible to detect multiple blood proteins from micro-samples in compliance with clinical requirements and this allows, for example, to monitor the nutritional or inflammatory status of patients. The implementation of this type of analysis opens new perspectives in the field of diagnosis, monitoring and risk assessment for personalized medicine approaches.


Assuntos
Monitoramento Biológico , Espectrometria de Massas em Tandem , Idoso , Humanos , Atividades Cotidianas , Proteínas Sanguíneas , Manejo de Espécimes , Espectrometria de Massas em Tandem/métodos
4.
Allergy ; 77(6): 1885-1894, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34652831

RESUMO

BACKGROUND: Limited information exists on nursing home (NH) residents regarding BNT162b2 vaccine efficacy in preventing SARS-CoV-2 and severe COVID-19, and its association with post-vaccine humoral response. METHODS: 396 residents from seven NHs suffering a SARS-CoV-2 B.1.1.7 (VOC-α) outbreak at least 14 days after a vaccine campaign were repeatedly tested using SARS-CoV-2 real-time reverse-transcriptase polymerase chain reaction on nasopharyngeal swab test (RT-qPCR). SARS-CoV-2 receptor-binding domain (RBD) of the S1 subunit (RBD-IgG) was measured in all residents. Nucleocapsid antigenemia (N-Ag) was measured in RT-qPCR-positive residents and serum neutralizing antibodies in vaccinated residents from one NH. RESULTS: The incidence of positive RT-qPCR was lower in residents vaccinated by two doses (72/317; 22.7%) vs one dose (10/31; 32.3%) or non-vaccinated residents (21/48; 43.7%; p < .01). COVID-19-induced deaths were observed in 5 of the 48 non-vaccinated residents (10.4%), in 2 of the 31 who had received one dose (6.4%), and in 3 of the 317 (0.9%) who had received two doses (p = .0007). Severe symptoms were more common in infected non-vaccinated residents (10/21; 47.6%) than in infected vaccinated residents (15/72; 21.0%; p = .002). Higher levels of RBD-IgG (n = 325) were associated with a lower SARS-CoV-2 incidence. No in vitro serum neutralization activity was found for RBD-IgG levels below 1050 AU/ml. RBD-IgG levels were inversely associated with N-Ag levels, found as a risk factor of severe COVID-19. CONCLUSIONS: Two BNT162b2 doses are associated with a 48% reduction of SARS-CoV-2 incidence and a 91.3% reduction of death risk in residents from NHs facing a VOC-α outbreak. Post-vaccine RBD-IgG levels correlate with BNT162b2 protection against SARS-CoV-2 B.1.1.7.


Assuntos
COVID-19 , Vacinas , Anticorpos Antivirais , Vacina BNT162 , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Surtos de Doenças/prevenção & controle , Humanos , Imunoglobulina G , SARS-CoV-2
5.
Clin Chem Lab Med ; 60(2): 191-197, 2022 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-34850616

RESUMO

OBJECTIVES: Human growth hormone (hGH) provocation test is an essential tool to assess growth hormone deficiency (GHD) in children and young adults. It is important to have a robust method to determine the hGH peak of stimulation. This work aimed to compare three common automated immunoassays for hGH quantification and to ascertain whether there are still result-related differences which can impact clinical decision. METHODS: We analyzed the GH provocation test for 39 young subjects from pediatric department of Montpellier hospital, admitted for suspicion of growth hormone deficiency. The full range of measurements as well as the peak level of serum GH were compared using three automated immunoassays on three different immunoanalyzers: IDS-hGH on iSYS, LIAISON-hGH on Liaison XL and Elecsys ROCHE-hGH, on COBAS 8000. RESULTS: A good correlation was obtained between methods for all measurements (r2>0.99) by using Passing-Bablok regression analysis. Bland-Altman analysis showed the best agreement between IDS-hGH and LIAISON-hGH systems (bias=-14.5%) compared to Elecsys ROCHE-hGH (bias=28.3%). When considering stratification of the study population and a unique cutoff, there were some discrepancies in interpretation of the results especially concerning the more recent Elecsys ROCHE-hGH assay. Nevertheless, when the adequate cutoff for each method was taken into account results were well correlated for all systems. CONCLUSIONS: A cutoff for Elecsys Roche-hGH method was established to better explain the results. Clinician must be aware of the use of assay-specific cutoff to correctly integrate the results of GH tests in the GHD diagnosis.


Assuntos
Hormônio do Crescimento Humano , Imunoensaio , Criança , Hormônio do Crescimento Humano/análise , Humanos , Imunoensaio/métodos
6.
Clin Chem Lab Med ; 60(11): 1763-1771, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36096492

RESUMO

OBJECTIVES: Aldosterone and renin determinations play an important role in the etiological diagnosis of secondary hypertension. The analytical performances of new aldosterone and renin immunoassays on the Lumipulse G600II® system (Fujierbio) were investigated and compared with those of the iSYS® system (IDS) on patients concerned by medical investigations in a context of suspected or proven Primary aldosteronism. METHODS: By using the Lumipulse® G Aldosterone and Renin assays we performed imprecision study, linearity and method comparison (n=107). Accuracy of this new renin assay was tested using the International Standard (WHO IS 68/356). We also assessed the equivalence of the different samples types (n=29). RESULTS: The imprecision evaluation showed all CVs <3% and <6% for Lumipulse® G Aldosterone and Renin assays respectively. The linearity was excellent over the clinical range and the comparison with the iSYS® assays (n=79) showed a strong correlation (R2=1) despite a slight tendency to underestimation (bias of -17.53 pg/mL or 48.56 pmol/L for aldosterone and -15.395 pg/mL for renin). Moreover, the contingency studies based on diagnostic criteria showed that Lumipulse® G results lead to the same clinical diagnosis that iSYS® results. A clear correlation was obtained between EDTA and heparin plasma as well as with the serum for all range of measures. CONCLUSIONS: The Lumipulse® G Aldosterone and Renin assays present performances compatible with a routine use in medical laboratories. The precise quantification in the low range can be of interest in some clinical contexts especially standing/laying tests. However, the standardisation against the WHO International Standard Renin would be advisable.


Assuntos
Hiperaldosteronismo , Hipertensão , Aldosterona , Ácido Edético , Heparina , Humanos , Hiperaldosteronismo/diagnóstico , Imunoensaio/métodos , Renina
7.
J Oncol Pharm Pract ; 28(1): 55-63, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33427019

RESUMO

OBJECTIVES: Methotrexate requires therapeutic drug monitoring in oncology because of narrow therapeutic index, especially the metabolite 7-hydroxymethotrexate exhibits nephrotoxicity. The goal of this study was to evaluate different assays and their impact on clinical decisions. METHODS: Following routine measurement with Abbott TDxFLx® assay (MTX-TDX), 62 samples were analysed on Architect®i1000 (MTX-ARCHI), Xpand® (ARK/XPND), Indiko® (ARK/INDI), and HPLC (MTX-HPLC) as the reference method. The influence of 7-hydroxymethotrexate was explored on ARK reagent to document the cause of the observed bias. ROC curves were built to study the impact of the method on the discharge thresholds for the patients at three levels. RESULTS: Total imprecision was below 2.60% for the methotrexate-ARCHI and close to 10% for both ARK assays for plasma pools. The correlation coefficients were 0.93, 0.93, 0.89 and 0.95, the Bland-Altman difference plot revealed a bias of 0.075, 0.037, 0.049 and -0.002, and the number of results exceeding the TE criteria of 0.1 µM was 17 (27%), 13 (21%), 15 (24%) and 15 (24%) for MTX-TDX, ARK/INDI, ARK/XPND and MTX-ARCHI, respectively. Cross reactivity with 7-hydroxymethotrexate was between 1 and 9%. Overestimation of methotrexate concentration was between -4% and +32%. The most robust clinical level was found to be the highest level (0.2 µM) with ROC curves. CONCLUSIONS: The authors found the best results for imprecision with chemiluminescent microparticle immunoassay method on methotrexate-ARCHI, with bias below to the RICOS recommendations and best correlation to the reference method. Impact on the threshold values for clinical decision need to be clearly exposed to clinicians.


Assuntos
Monitoramento de Medicamentos , Metotrexato , Cromatografia Líquida de Alta Pressão , Imunoensaio de Fluorescência por Polarização , Humanos , Imunoensaio
8.
Clin Chem Lab Med ; 59(7): 1299-1306, 2021 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-33544524

RESUMO

OBJECTIVES: Inflammation is a hallmark of heart failure (HF) and among inflammatory biomarkers, the most studied remains the C-reactive protein (CRP). In recent years several biomarkers have emerged, such as sST2 and soluble urokinase-type plasminogen activator receptor (suPAR). This study set out to examine the relative importance of long-time prognostic strength of suPAR and the potential additive information on patient risk with chronic HF in comparison with pronostic value of CRP and sST2. METHODS: Demographics, clinical and biological variables were assessed in a total of 182 patients with chronic HF over median follow-up period of 80 months. Inflammatory biomarkers (i.e., CRP, sST2, and suPAR) were performed. RESULTS: In univariate Cox regression analysis age, NYHA class, MAGGIC score and the five biomarkers (N-terminal pro brain natriuretic peptide [NT-proBNP], high-sensitive cardiac troponin T [hs-cTnT], CRP, sST2, and suPAR) were associated with both all-cause and cardiovascular mortality. In the multivariate model, only NT-proBNP, suPAR, and MAGGIC score remained independent predictors of all-cause mortality as well as of cardiovascular mortality. Risk classification analysis was significantly improved with the addition of suPAR particularly for all-cause short- and long-term mortality. Using a classification tree approach, the same three variables could be considered as significant classifier variables to predict all-cause or cardiovascular mortality and an algorithm were reported. We demonstrated the favorable outcome associated with patients with a low MAGGIC score and a low suPAR level by comparison to patients with low MAGGIC score but high suPAR values. CONCLUSIONS: The main findings of our study are (1) that among the three inflammatory biomarkers, only suPAR levels were independently associated with 96-month mortality for patients with chronic HF and (2) that an algorithm based on clinical score, a cardiomyocyte stress biomarker and an inflammatory biomarker could help to a more reliable long term risk stratification in heart failure.


Assuntos
Insuficiência Cardíaca , Receptores de Ativador de Plasminogênio Tipo Uroquinase , Biomarcadores , Proteína C-Reativa/análise , Doença Crônica , Insuficiência Cardíaca/diagnóstico , Humanos , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Prognóstico , Troponina T
9.
Anal Bioanal Chem ; 413(19): 4707-4725, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33987701

RESUMO

The quantification of low abundant proteins in complex matrices by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) remains challenging. A measurement procedure based on optimized antibody-free sample preparation and isotope dilution coupled to LC-MS/MS was developed to quantify procalcitonin (PCT) in human serum at sub-microgram per liter level. A combination of sodium deoxycholate-assisted protein precipitation with acetonitrile, solid-phase extraction, and trypsin digestion assisted with Tween-20 enhanced the method sensitivity. Linearity was established through peptide-based calibration curves in the serum matrix (0.092-5.222 µg/L of PCT) with a good linear fit (R2 ≥ 0.999). Quality control materials spiked with known amounts of protein-based standards were used to evaluate the method's accuracy. The bias ranged from -2.6 to +4.3%, and the intra-day and inter-day coefficients of variations (CVs) were below 2.2% for peptide-based quality controls. A well-characterized correction factor was determined and applied to compensate for digestion incompleteness and material loss before the internal standards spike. Results with metrological traceability to the SI units were established using standard peptide of well-characterized purity determined by peptide impurity corrected amino acid analysis. The validated method enables accurate quantification of PCT in human serum at a limit of quantification down to 0.245 µg/L (bias -1.9%, precision 9.1%). The method was successfully applied to serum samples obtained from patients with sepsis. Interestingly, the PCT concentration reported implementing the isotope dilution LC-MS/MS method was twofold lower than the concentration provided by an immunoassay.


Assuntos
Calcitonina/química , Espectrometria de Massas/métodos , Pró-Calcitonina/química , Soro/química , Sequência de Aminoácidos , Calibragem , Cromatografia Líquida/métodos , Humanos , Sensibilidade e Especificidade
10.
Scand J Clin Lab Invest ; 81(4): 290-297, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33908840

RESUMO

Point of care testing makes it possible to obtain results in an extremely short time. Recently, radiometer has expanded the panel of tests available on its ABL90 FLEX PLUS blood gas analyzer (ABL90) by adding urea and creatinine. The aim of this study was to verify the performance of these new parameters. This included assessment of imprecision, linearity, accuracy by comparison with central laboratory standard assays and interferences. In addition, clinical utility in a dialysis center was evaluated. Within-lab coefficients of variation were close to 2%. The mean and limits of agreement (mean ± 1.96 SD) of the difference between ABL90 and Roche enzymatic assays on cobas 8000 were 0.5 (from -1.4 to 2.3) mmol/L and -0.9 (from -19.5 to 17.8) µmol/L for urea and creatinine, respectively. The ABL90 enzymatic urea and creatinine assays met the acceptance criteria based on biological variation for imprecision and showed good agreement with central laboratory. The two assays were unaffected by hematocrit variation between 20 and 70%, hemolysis and icterus interferences. It should be noted that the relationship between lab methods and ABL90 was conserved even for high pre-dialysis values allowing easy access to dialysis adequacy parameters (Kt/V) and muscle mass evaluation (creatinine index). Rapid measurement of creatinine and urea using whole blood specimens on ABL90 appears as a fast and convenient method. Analytical performances were in accordance with our expectations without any significant interferences by hemolysis or icterus.


Assuntos
Gasometria/instrumentação , Gasometria/métodos , Creatinina/sangue , Ureia/sangue , Idoso , Artefatos , Feminino , Hemólise , Humanos , Masculino , Testes Imediatos
11.
Medicina (Kaunas) ; 57(10)2021 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-34684033

RESUMO

Half of the patients with heart failure (HF) have preserved ejection fraction (HFpEF). To date, there are no specific markers to distinguish this subgroup. The main objective of this work was to stratify HF patients using current biochemical markers coupled with clinical data. The cohort study included HFpEF (n = 24) and heart failure with reduced ejection fraction (HFrEF) (n = 34) patients as usually considered in clinical practice based on cardiac imaging (EF ≥ 50% for HFpEF; EF < 50% for HFrEF). Routine blood tests consisted of measuring biomarkers of renal and heart functions, inflammation, and iron metabolism. A multi-test approach and analysis of peripheral blood samples aimed to establish a computerized Machine Learning strategy to provide a blood signature to distinguish HFpEF and HFrEF. Based on logistic regression, demographic characteristics and clinical biomarkers showed no statistical significance to differentiate the HFpEF and HFrEF patient subgroups. Hence a multivariate factorial discriminant analysis, performed blindly using the data set, allowed us to stratify the two HF groups. Consequently, a Machine Learning (ML) strategy was developed using the same variables in a genetic algorithm approach. ML provided very encouraging explorative results when considering the small size of the samples applied. The accuracy and the sensitivity were high for both validation and test groups (69% and 100%, 64% and 75%, respectively). Sensitivity was 100% for the validation and 75% for the test group, whereas specificity was 44% and 55% for the validation and test groups because of the small number of samples. Lastly, the precision was acceptable, with 58% in the validation and 60% in the test group. Combining biochemical and clinical markers is an excellent entry to develop a computer classification tool to diagnose HFpEF. This translational approach is a springboard for improving new personalized treatment methods and identifying "high-yield" populations for clinical trials.


Assuntos
Insuficiência Cardíaca , Biomarcadores , Estudos de Coortes , Insuficiência Cardíaca/diagnóstico , Humanos , Aprendizado de Máquina , Prognóstico , Volume Sistólico
12.
Medicina (Kaunas) ; 57(10)2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34684084

RESUMO

Inflammatory processes are deeply involved in ischemia-reperfusion injuries (IRI) and ventricular remodelling (VR) after a ST-segment elevation myocardial infarction (STEMI). They are associated with clinical adverse events (heart failure and cardiovascular death) adding damage to the myocardium after reperfusion. Moreover, acute myocardial infarction (AMI) induces a local sympathetic denervation leading to electrical instability and arrythmia. Colchicine, a well-known alkaloid with direct anti-inflammatory effects, was shown to reduce the myocardial necrosis size and limit the VR. In a recent proof of concept study, colchicine appears to prevent sympathetic denervation in a mice model of ischemia/reperfusion, but not in the necrosis or in the border zone areas. The Colchicine to Prevent Sympathetic Denervation after an AMI study (COLD-MI) is an ongoing, confirmative, prospective, monocentre, randomized, open-label trial. The COLD-MI trial aims to evaluate the intensity of sympathetic denervation after AMI and its potential modulation due to low dose colchicine. Sympathetic denervation will be noninvasively evaluated using single-photon emission computed tomography (SPECT). After a first episode of STEMI (Initial TIMI flow ≤ 1) and primary percutaneous coronary intervention (PPCI), patients will be randomized (n = 56) in a 1:1 ratio to either receive colchicine or not for 30 days. The primary end point will be the percentage of myocardial denervation measured by 123I-metaiodobenzylguanidine (123I-MIBG) SPECT at a 6-month follow-up. The main secondary end points will be basic ECG parameters (QRS duration, corrected QT) and HRV parameters from a 24 hour-recording Holter at 1- and 6-months follow-up. Results from this study will contribute to a better understanding of the cardioprotective effect of colchicine after AMI. The present study describes the rationale, design, and methods of the trial.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Animais , Colchicina/uso terapêutico , Humanos , Camundongos , Infarto do Miocárdio/tratamento farmacológico , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Simpatectomia
13.
Crit Care Med ; 48(4): e277-e284, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32205617

RESUMO

OBJECTIVES: Urinary biomarkers and renal Doppler sonography remain considered as promising tools to distinguish transient from persistent acute kidney injury. The performance of the urinary biomarker, tissue inhibitor of metalloproteinase-2 x insulin-like growth factor-binding protein 7 and of renal resistive index to predict persistent acute kidney injury showed contradictory results. Our aim was to evaluate the performance of tissue inhibitor of metalloproteinase-2 x insulin-like growth factor-binding protein 7 and renal resistive index in predicting reversibility of acute kidney injury in critically ill patients. DESIGN: Prospective observational study. SETTING: Twenty-bed medical ICU in an university hospital. PATIENTS: Consecutive patients with acute kidney injury. INTERVENTION: None. MEASUREMENTS AND MAIN RESULTS: Renal resistive index was measured within 12 hours after admission, and urinary tissue inhibitor of metalloproteinase-2 and insulin-like growth factor-binding protein 7 was measured at H0, H6, H12, and H24. Renal dysfunction reversibility was evaluated at day 3. Receiver operating characteristic curves were plotted to evaluate diagnostic performance of renal resistive index and tissue inhibitor of metalloproteinase-2 x insulin-like growth factor-binding protein 7 to predict a persistent acute kidney injury. Overall, 100 patients were included in whom 50 with persistent acute kidney injury. Renal resistive index was higher in persistent acute kidney injury group. Urinary tissue inhibitor of metalloproteinase-2 x insulin-like growth factor-binding protein 7 was not significantly different at each time between both groups. The performance of tissue inhibitor of metalloproteinase-2 x insulin-like growth factor-binding protein 7 was poor with respectively an area under the receiver operating characteristic curves of 0.57 (95% CI, 0.45-0.68), 0.58 (95% CI, 0.47-0.69), 0.61 (95% CI, 0.50-0.72), and 0.57 (95% CI, 0.46-0.68) at H0, H6, H12, and H24. The area under the receiver operating characteristic curve for renal resistive index was 0.93 (95% CI, 0.89-0.98). A renal resistive index greater than or equal to 0.685 predicting persistent acute kidney injury with 78% (95% CI, 64-88%) sensitivity and 90% (95% CI, 78-97%) specificity. CONCLUSIONS: Renal resistive index had a good performance for predicting the reversibility of acute kidney injury in critically ill patients. Urinary tissue inhibitor of metalloproteinase-2 x insulin-like growth factor-binding protein 7 was unable to differentiate transient from persistent acute kidney injury.


Assuntos
Injúria Renal Aguda/sangue , Estado Terminal , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/sangue , Inibidor Tecidual de Metaloproteinase-2/sangue , Biomarcadores/sangue , Testes Diagnósticos de Rotina , Feminino , Humanos , Rim/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resistência Vascular
14.
Clin Chem Lab Med ; 58(8): 1232-1241, 2020 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-32267242

RESUMO

Background All general biochemistry instruments allow the measure of hemolysis index (HI), and suppliers provide an acceptable HI for each assay without consideration of the analyte value or its clinical application. Our first objective was to measure the impact of hemolysis degree on plasma biochemical and immunochemical analytes to determine the maximum allowable HI for each of them using four calculation methods as significant bias in comparison to manufacturer's data. The second objective was to assess whether the maximum allowable HI varied according to the analyte values. Methods Twenty analytes were measured in hemolyzate-treated plasma to determine the HI leading to a significant change compared to baseline value. Analytes were assessed at one (3 analytes), two (5 analytes) and three (12 analytes) values according to their sensitivity to hemolysis and their clinical impact. We used four calculation methods as significant limit from baseline value: the total change limit (TCL), the 10% change (10%Δ), the analytical change limit and the reference change value. Results Allowable HI was significantly different according to the threshold chosen for most analytes and was also dependent on the analyte value for alkaline phosphatase, alanine aminotransferase, aspartate aminotransferase, creatine kinase, iron, haptoglobin and high sensitivity troponin T. No hemolysis interference was observed for albumin, creatinine, C-reactive protein, and procalcitonin even at an HI value of 11 g/L. Conclusions This study highlights that TCL is the most appropriate calculation method to determine allowable HI in practice for biochemical and immunochemical parameters using Cobas 8000© from Roche Diagnostics. In addition, different allowable HI were found according to analyte value leading to optimization of resampling to save time in patient care.


Assuntos
Hemólise , Humanos , Valores de Referência , Reprodutibilidade dos Testes
15.
Scand J Clin Lab Invest ; 80(7): 541-545, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33124916

RESUMO

To determine the analytical performance of Novel VITROS BRAHMS Procalcitonin Immunoassay on VITROS 3600 and correlation with BRAHMS PCT sensitive KRYPTOR reference method. Analytical performances including imprecision studies, linearity, limit of detection (LoD) and determination of hemolysis index were performed for VITROS BRAHMS PCT assay. Imprecision was assessed on plasma pool and internal control with 2 levels. The method comparison was performed using 162 plasma obtained from clinical departments. The total imprecision was acceptable and all CV were <5%. The LoD was in accordance with manufacturer's claims. The equation of linearity in the lower range was found to be y = 1.0014x - 0.0091, with r2 = 1. No interference to hemoglobin up to 11 g/L was observed. Correlation studies showed a good correlation between PCT measurements using VITROS BRAHMS PCT assay against KRYPTOR system including for values lower than 2 µg/L. The novel VITROS BRAHMS PCT assay from OrthoClinical Diagnostics shows analytical performances acceptable for clinical use. In addition, the concordance with KRYPTOR method was fine at all clinical cut-offs.


Assuntos
Imunoensaio/métodos , Pró-Calcitonina/sangue , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Análise de Regressão
17.
Eur J Nutr ; 58(8): 3091-3107, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30392135

RESUMO

PURPOSE: Palm (PO) and olive oils (OO) are the two most consumed and/or used oils in the world for food elaboration. These oils should not be confused with the solid palm stearin which is widely used in pastry making. Large number of studies was reported dealing with adverse/beneficial cardiovascular effects of PO and OO, whereas few studies were conducted to compare their potential effects on hepatic steatosis and liver lipid metabolism. The aim of this study was to compare the metabolic effects of high intake of POs (both crude and refined) and virgin OO on surrogate parameters of glucose tolerance, hepatic lipid metabolism and liver integrity. METHODS: Thirty-two young male Wistar rats were divided into four equal groups and fed either control diet (11% energy from fat) or three high-fat diets rich in crude or refined POs or in OO (56% energy from fat), during 12 weeks. Systemic blood and liver biochemical parameters linked to glucose and lipid metabolism as well as hepatic steatosis and liver fatty acid composition were explored. The inflammation and oxidative stress status as well as the expression of several genes/proteins were also analyzed. RESULTS: The major effects of POs intake concerned glucose metabolism and liver fatty acid composition, whereas the major effects of OO intake concerned hepatic TG accumulation, inflammation, and cytolysis. CONCLUSIONS: In conclusion, high dietary intake of PO compromises glucose tolerance whereas high dietary intake of OO compromises hepatic lipid composition and liver integrity. However, adverse hepatic effects of OO observed in this study may not be transposed to human since, (a) the rodent model could lead to different effects than those observed in humans and (b) the average normal OO amounts ingested in the population are lower than those corresponding to a high-fat diet. So, further studies are needed to determine a maximum non-invasive dietary intake of OO.


Assuntos
Dieta/métodos , Glucose/metabolismo , Metabolismo dos Lipídeos/fisiologia , Fígado/metabolismo , Azeite de Oliva/farmacologia , Óleo de Palmeira/farmacologia , Animais , Masculino , Modelos Animais , Azeite de Oliva/administração & dosagem , Óleo de Palmeira/administração & dosagem , Ratos , Ratos Wistar
18.
Clin Endocrinol (Oxf) ; 88(6): 863-872, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29633301

RESUMO

OBJECTIVE: This study compared the profiles of the two types of anorexia nervosa (AN; restrictive: AN-R, and binge eating/purging: AN-BP) in terms of body composition, gynaecological status, disease history and the potential effects on bone metabolism. DESIGN: Two hundred and eighty-six women with AN (21.8 ± 6.5 years; 204 AN-R and 82 AN-BP) and 130 age-matched controls (CON; 22.6 ± 6.8 years) were enrolled. Areal bone mineral density (aBMD) was determined using DXA and resting energy expenditure (REE) was indirectly assessed using calorimetry. Markers of bone formation (osteocalcin [OC], procollagen type I N-terminal propeptide [PINP] and resorption (type I-C telopeptide breakdown products [CTX]) and leptin were concomitantly evaluated. RESULTS: Anorexia nervosa patients presented an alteration in aBMD and bone turnover. When compared according to type, AN-BP were older than AN-R and showed less severe undernutrition, lower CTx levels, longer duration of AN, and higher REE levels and aBMD at radius and lumbar spine. After adjustment for age, weight and hormonal contraceptive use, the aBMD and CTx differences disappeared. In both AN groups, aBMD was positively correlated with anthropometric parameters and negatively correlated with durations of AN and amenorrhoea, the bone formation markers (OC and PINP) and the leptin/fat mass ratio. REE was positively correlated with aBMD in AN-R patients only. CONCLUSIONS: This study shows the profiles of AN patients according to AN type. However, the impact of the profile characteristics on bone status, although significant, was minor and disappeared after multiple adjustments. The positive correlation between REE and aBMD reinforces the concept that energy disposal and bone metabolism are strongly interdependent.


Assuntos
Anorexia Nervosa/metabolismo , Adolescente , Adulto , Antropometria , Biomarcadores/metabolismo , Composição Corporal/fisiologia , Peso Corporal/fisiologia , Densidade Óssea/fisiologia , Remodelação Óssea/fisiologia , Feminino , Humanos , Pessoa de Meia-Idade , Adulto Jovem
19.
Clin Chem Lab Med ; 57(2): 244-249, 2018 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-30183664

RESUMO

Background The determination of parathyroid hormone (PTH) is essential for exploring phosphocalcic disorders especially in patients with renal failure. At present, second or third generation PTH assays are available on the market from Roche Diagnostics as well as from others companies but the lack of standardization has complicated the interpretation. Methods We wanted to assess the clinical impact by measuring the PTH levels with the two generations concomitantly on different groups of populations including 46 healthy, 103 pre-dialyzed and 73 hemodialyzed (HD) patients. Results In healthy subjects, the PTH concentrations were not different whatever the generation used, whereas beyond 200 pg/mL, we reported an overestimation of the second generation PTH. In patients with chronic kidney disease (CKD) stage 3-5 the observed differences between the two generations increase with increasing PTH levels and decreasing glomerular filtration rate (GFR). Classification according to the kidney disease: improving global outcomes (KDIGO) revealed a high percentage of discordant results between the two generations (κ coefficient <0.20). These discrepancies are clinically relevant as PTH levels remain the cornerstone for diagnosis and treatment of the CKD-mineral and bone disorder (CKD-MBD). Conclusions The introduction of a new PTH assay generation in clinical practice should be carried out with caution.


Assuntos
Falência Renal Crônica/sangue , Hormônio Paratireóideo/sangue , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Taxa de Filtração Glomerular , Humanos , Falência Renal Crônica/fisiopatologia , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Diálise Renal
20.
Clin Chem Lab Med ; 56(3): 413-421, 2018 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-28888086

RESUMO

BACKGROUND: Blood specimens are transported from clinical departments to the biochemistry laboratory by hospital courier service, sometimes over long distances. The aim of this study was to assess the stability of common biochemical analytes in venous blood under our routine transport conditions and to evaluate analyte stability after prompt or delayed centrifugation. METHODS: We investigated pre- and postanalytical contributions of 32 biochemical analytes in plasma and serum samples from 10 patients (healthy adults and patients from intensive care units). Differences in analyte concentrations between baseline (T0) and different time intervals (2, 4, 6, 8, 12 and 24 h) following storage after prompt and delayed centrifugation were reported. Evaluation was against the total change limit as described by Oddoze et al. (Oddoze C, Lombard E, Portugal H. Stability study of 81 analytes in human whole blood, in serum and in plasma. Clin Biochem 2012;45:464-9). RESULTS: The majority of analytes were stable with delayed separation up to 12 h, except for potassium, C-peptide, osteocalcin, parathyroid hormone (PTH), bicarbonate and LDH. After prompt centrifugation and storage at 4°C, stability was greatly increased up to 48 h for most analytes. LDH and bicarbonate had the lowest stability after centrifugation; therefore, no reanalysis of these analytes in a centrifuged tube can be allowed. CONCLUSIONS: Knowledge of analyte stability is crucial to interpret biological analysis with confidence. However, centrifugation prior to transport is time consuming, and the transfer of plasma or serum from a primary tube to a secondary tube increases the risk of preanalytical errors. For analytes that are stable in whole blood for 24 h or more, it seems that there is no benefit to centrifuge before transport.


Assuntos
Análise Química do Sangue , Preservação de Sangue , Heparina/sangue , Lítio/sangue , Potássio/sangue , Coleta de Amostras Sanguíneas , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA