Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 279
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747561

RESUMO

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

2.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38225168

RESUMO

AIMS: Conduction abnormalities post-transcatheter aortic valve implantation (TAVI) are common. Post-TAVI PR prolongation was mainly studied as an adjunct to new-onset bundle branch block. The net effect of isolated PR prolongation (IPRP) without post-TAVI QRS changes is not well known. The aim of this study was to define the incidence and clinical significance of post-TAVI IPRP. METHODS AND RESULTS: A total of 1108 consecutive TAVI patients were reviewed. Patients with IPRP were compared with patients without post-TAVI electrocardiogram (ECG) changes. Clinical outcomes included permanent pacemaker implantation (PPI) and overall mortality. A total of 146 patients with IPRP were compared with 290 patients without post-TAVI ECG changes. At 1 year follow-up, 4 (2.7%) and 7 (2.4%) patients underwent PPI (P = 0.838) and 10 (6.8%) and 25 (8.6%) died (P = 0.521), from the study and control groups, respectively. No patient with IPRP and narrow QRS underwent PPI during 1 year post-TAVI, and all death events were non-cardiac except one unknown cause. Permanent pacemaker implantation rates among patients with IPRP and wide QRS were higher (n = 4, 12.1%), compared with patients with wide QRS without post-TAVI ECG change (n = 3, 4%) however not reaching statistical significance (P = 0.126). Multivariate Cox proportional hazards model demonstrated that in patients with narrow QRS, neither PR prolongation nor baseline or maximal PR intervals was associated with the combined endpoint of PPI and mortality. However, in patients with wide QRS, baseline PR intervals and QRS width, but not PR prolongation were associated with the combined outcome. CONCLUSION: Post-TAVI IPRP in patients with narrow QRS is not associated with adverse outcome. This finding may translate clinically into a more permissive approach to these patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Incidência , Relevância Clínica , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/terapia , Eletrocardiografia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos
3.
Eur Heart J ; 43(7): 641-650, 2022 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-34463727

RESUMO

AIMS: Severe mitral regurgitation (MR) following acute myocardial infarction (MI) is associated with high mortality rates and has inconclusive recommendations in clinical guidelines. We aimed to report the international experience of patients with secondary MR following acute MI and compare the outcomes of those treated conservatively, surgically, and percutaneously. METHODS AND RESULTS: Retrospective international registry of consecutive patients with at least moderate-to-severe MR following MI treated in 21 centres in North America, Europe, and the Middle East. The registry included patients treated conservatively and those having surgical mitral valve repair or replacement (SMVR) or percutaneous mitral valve repair (PMVR) using edge-to-edge repair. The primary endpoint was in-hospital mortality. A total of 471 patients were included (43% female, age 73 ± 11 years): 205 underwent interventions, of whom 106 were SMVR and 99 PMVR. Patients who underwent mitral valve intervention were in a worse clinical state (Killip class ≥3 in 60% vs. 43%, P < 0.01), but yet had lower in-hospital and 1-year mortality compared with those treated conservatively [11% vs. 27%, P < 0.01 and 16% vs. 35%, P < 0.01; adjusted hazard ratio (HR) 0.28, 95% confidence interval (CI) 0.18-0.46, P < 0.01]. Surgical mitral valve repair or replacement was performed earlier than PMVR [median of 12 days from MI date (interquartile range 5-19) vs. 19 days (10-40), P < 0.01]. The immediate procedural success did not differ between SMVR and PMVR (92% vs. 93%, P = 0.53). However, in-hospital and 1-year mortality rates were significantly higher in SMVR than in PMVR (16% vs. 6%, P = 0.03 and 31% vs. 17%, P = 0.04; adjusted HR 3.75, 95% CI 1.55-9.07, P < 0.01). CONCLUSIONS: Early intervention may mitigate the poor prognosis associated with conservative therapy in patients with post-MI MR. Percutaneous mitral valve repair can serve as an alternative for surgery in reducing MR for high-risk patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Infarto do Miocárdio , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Estudos Retrospectivos , Resultado do Tratamento
4.
J Interv Cardiol ; 2022: 1683309, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35414797

RESUMO

Objectives: This study was planned for evaluating the safety and efficacy of SPAS (stent positioning assistance system) device in first-in-human procedures. Background: SPAS is a novel device that can be used for improved positioning of coronary stents. Methods: Consecutive patients underwent percutaneous coronary intervention (PCI) with the SPAS device. Device-related adverse and serious adverse events were evaluated in addition to a dedicated questionnaire completed by operators immediately after using SPAS. Results: The SPAS device was deployed in 55 PCI procedures, comprising of heavily calcified lesions (33.3%), totally occluded (7.4%), and severely tortuous vessels (7.4%). In these procedures, nonbifurcation and nonostial (53.7%), bifurcation (22.2%), and edge-to-edge (24.1%) stenting techniques were employed. Analysis of the pooled scores for the five satisfaction-related questions gave an average score of 5.6 ± 1.5, with 40 (75.5%) operators providing an average satisfaction grade of >5; the average operator-rated SPAS device accuracy performance scores exceeded 6 out of 7 (on visual analog score). The time spent for positioning the stent with the SPAS device averaged 41 ± 68.0 seconds. The SPAS device was rated as easy to use (6.1 ± 1.6) and reliable (6.1 ± 1.7). No device-related adverse events were reported. Conclusion: This stent positioning device was evaluated in a consecutive cohort of standard and complex PCI procedures. The device was shown to be safe, easy, and precise to use, both in standard and complex cases.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Estudos de Coortes , Angiografia Coronária , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/métodos , Stents , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 97(4): E580-E587, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32894804

RESUMO

OBJECTIVES: We sought to document aortic cusps fluoroscopic projections and their distributions using leaflet alignment which is a novel concept to optimize visualization of leaflets and for guiding BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent coronary artery obstruction) and determine whether these projections were feasible in catheter laboratory. BACKGROUND: Optimal fluoroscopic projections of aortic valve cusps have not been well described. METHODS: A total of 128 pre-transcatheter aortic valve replacement (pre-TAVR) computed tomographies (CT) (72 native valves and 56 bioprosthetic surgical valves) were analyzed. Using CT software (3Mensio, Pie medical imaging, the Netherlands), leaflet alignment was performed and the feasibility of these angles, which were defined as rate of obtainable with efforts (within LAO/RAO of 85° and CRA/CAU of 50°) were evaluated. RESULTS: High feasibility was seen in right coronary cusp (RCC) front view (100%) and left coronary cusp (LCC) side view (99.2%), followed by noncoronary cusp side view (95.3%). In contrast, low feasibility of RCC side view (7.8%) and LCC front view (47.6%) was observed. No statistical differences were seen between the distribution of native valves and bioprosthetic surgical valves. With patient/table tilt of 20°LAO and 10°CRA, the feasibility of RCC side view and LCC front view increased to 43.7 and 85.2%, respectively. CONCLUSION: Distributions of each cusp's leaflet alignment follows "sigmoid curve" which can provide better understanding of aortic valve cusp orientation in TAVR and BASILICA. RCC side view used in right cusp BASILICA is commonly unachievable in catheter laboratory and may improve with patient/table tilt.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 98(6): E862-E869, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33961729

RESUMO

OBJECTIVES: To evaluate the use and outcomes of percutaneous mechanical circulatory support (pMCS) utilized during transcatheter aortic valve implantation (TAVI) from high-volume centers. METHODS AND RESULTS: Our international multicenter registry including 13 high-volume TAVI centers with 87 patients (76.5 ± 11.8 years, 63.2% men) who underwent TAVI for severe aortic stenosis and required pMCS (75.9% VA-ECMO, 19.5% Impella CP, 4.6% TandemHeart) during the procedure (prior to TAVI 39.1%, emergent rescue 50.6%, following TAVI 10.3%). The procedures were considered high-risk, with 50.6% having severe left ventricular dysfunction, 24.1% biventricular dysfunction, and 32.2% severe pulmonary hypertension. In-hospital and 1-year mortality were 27.5% and 49.4%, respectively. Patients with prophylactic hemodynamic support had lower periprocedural mortality compared to patients with rescue insertion of pMCS (log rank = 0.013) and patients who did not undergo cardiopulmonary resuscitation during the TAVI procedure had better short and long term survival (log rank <0.001 and 0.015, respectively). CONCLUSIONS: Given the overall survival rate and low frequency of pMCS-related complications, our study results support the use of pMCS prophylactically or during the course of TAVI (bailout) in order to improve clinical outcomes in high-risk procedures or in case of acute life-threatening hemodynamic collapse.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Curr Cardiol Rep ; 22(4): 23, 2020 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-32067112

RESUMO

PURPOSE OF REVIEW: A combination of evolving 3D printing technologies, new 3D printable materials, and multi-disciplinary collaborations have made 3D printing applications for transcatheter aortic valve replacement (TAVR) a promising tool to promote innovation, increase procedural success, and provide a compelling educational tool. This review synthesizes the knowledge via publications and our group's experience in this area that exemplify uses of 3D printing for TAVR. RECENT FINDINGS: Patient-specific 3D-printed models have been used for TAVR pre-procedural device sizing, benchtop prediction of procedural complications, planning for valve-in-valve and bicuspid aortic valve procedures, and more. Recent publications also demonstrate how 3D printing can be used to test assumptions about why certain complications occur during THV implantation. Finally, new materials and combinations of existing materials are starting to bridge the large divide between current 3D material and cardiac tissue properties. Several studies have demonstrated the utility of 3D printing in understanding challenges of TAVR. Innovative approaches to benchtop testing and multi-material printing have brought us closer to being able to predict how a THV will interact with a specific patient's aortic anatomy. This work to date is likely to open the door for advancements in other areas of structural heart disease, such as interventions involving the mitral valve, tricuspid valve, and left atrial appendage.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Impressão Tridimensional , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
8.
Circulation ; 137(4): 388-399, 2018 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29358344

RESUMO

Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.


Assuntos
Bioprótese/classificação , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/classificação , Valvas Cardíacas/cirurgia , Falha de Prótese , Terminologia como Assunto , Substituição da Valva Aórtica Transcateter/instrumentação , Remoção de Dispositivo , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/fisiopatologia , Humanos , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 94(6): 863-869, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30856285

RESUMO

Bioprosthetic valve dysfunction was treated in the past with redo open heart surgery. The need to identify occult leaflet infection was not an important requirement as all valve tissue was removed during surgery. With the dramatic growth in transcatheter aortic valve replacement (TAVR) valve-in-valve (ViV) therapy, identification of occult infection is of major significance. TAVR should be rarely performed in infected prosthetic valves and the optimal approach should include open heart surgery and removal of infected tissue. With surgical implants, it can be challenging to distinguish infection from degeneration. The use of advanced imaging modalities, including 18F-fluorodeoxyglucose positron emission tomography/computed tomography, in the diagnosis of occult infection is emerging. We report the use of this imaging modality to identify or exclude endocarditis in patients with prosthetic valves who were candidates for ViV therapy.


Assuntos
Bioprótese/efeitos adversos , Endocardite/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese/diagnóstico por imagem , Adulto , Idoso , Tomada de Decisão Clínica , Remoção de Dispositivo , Diagnóstico Diferencial , Endocardite/etiologia , Endocardite/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Seleção de Pacientes , Valor Preditivo dos Testes , Falha de Prótese , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Substituição da Valva Aórtica Transcateter/instrumentação
10.
J Interv Cardiol ; 2019: 7598581, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31777471

RESUMO

OBJECTIVE: To identify outcomes of patients undergoing emergency transcatheter aortic valve replacement (TAVR) and determine predictors of in-hospital mortality. BACKGROUND: Emergency TAVR has emerged as a viable treatment strategy for patients with decompensated severe aortic stenosis and/or regurgitation; however, data on patients undergoing emergency TAVR are limited. METHODS: All emergency TAVR procedures were identified from a single tertiary academic center between January 2015 and August 2018. RESULTS: 31 patients underwent emergency TAVR due to cardiogenic shock (26 patients), electrical instability with incessant ventricular tachycardia (2 patients), severe refractory angina (2 patients), and decompensated heart failure with hypoxemic respiratory failure requiring mechanical ventilation (1 patient). Mechanical circulatory support (MCS) was used in 16 (51.6%). MCS initiation occurred immediately prior to TAVR in 10 patients and placed post-TAVR in 6 patients. 6 patients died before hospital discharge (in-hospital mortality 19.4%). 1-year and 2-year survival rates were 61.0% and 55.9%, respectively. Univariate predictors of in-hospital mortality were preprocedural pulmonary artery pulsatility index (PAPi) ≤1.8 (66.7% vs. 20.0%, p=0.01), intraprocedural cardiopulmonary resuscitation (CPR) (83.3% vs 4.0%, p ≤ 0.001), acute kidney injury post-TAVR (80.0% vs. 4.2%, p ≤ 0.001), initiation of dialysis post-TAVR (60.0% vs. 4.2%, p ≤ 0.001), and MCS initiation post-TAVR (50.0% vs. 12.0%, p=0.03). MCS initiation before TAVR was associated with improved survival compared with post-TAVR initiation. CONCLUSION: Emergency TAVR in extreme risk patients with acute decompensated heart failure or cardiogenic shock secondary to severe aortic valve disease is associated with high in-hospital mortality rates. Careful patient selection taking into account right heart function, assessed by PAPi, and early utilization of MCS may improve survival following emergency TAVR.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Emergências , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter/mortalidade , Injúria Renal Aguda/mortalidade , Idoso , Angina Instável/cirurgia , Reanimação Cardiopulmonar , Oxigenação por Membrana Extracorpórea , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Período Intraoperatório , Masculino , Fluxo Pulsátil , Diálise Renal/mortalidade , Insuficiência Respiratória/cirurgia , Choque Cardiogênico/cirurgia , Taquicardia Ventricular/cirurgia , Washington/epidemiologia
11.
Eur Heart J ; 39(8): 687-695, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29020413

RESUMO

Aims: There are limited data on coronary obstruction following transcatheter valve-in-valve (ViV) implantation inside failed aortic bioprostheses. The objectives of this study were to determine the incidence, predictors, and clinical outcomes of coronary obstruction in transcatheter ViV procedures. Methods and results: A total of 1612 aortic procedures from the Valve-in-Valve International Data (VIVID) Registry were evaluated. Data were subject to centralized blinded corelab computed tomography (CT) analysis in a subset of patients. The virtual transcatheter valve to coronary ostium distance (VTC) was determined. A total of 37 patients (2.3%) had clinically evident coronary obstruction. Baseline clinical characteristics in the coronary obstruction patients were similar to controls. Coronary obstruction was more common in stented bioprostheses with externally mounted leaflets or stentless bioprostheses than in stented with internally mounted leaflets bioprostheses (6.1% vs. 3.7% vs. 0.8%, respectively; P < 0.001). CT measurements were obtained in 20 (54%) and 90 (5.4%) of patients with and without coronary obstruction, respectively. VTC distance was shorter in coronary obstruction patients in relation to controls (3.24 ± 2.22 vs. 6.30 ± 2.34, respectively; P < 0.001). Using multivariable analysis, the use of a stentless or stented bioprosthesis with externally mounted leaflets [odds ratio (OR): 7.67; 95% confidence interval (CI): 3.14-18.7; P < 0.001] associated with coronary obstruction for the global population. In a second model with CT data, a shorter VTC distance predicted this complication (OR: 0.22 per 1 mm increase; 95% CI: 0.09-0.51; P < 0.001), with an optimal cut-off level of 4 mm (area under the curve: 0.943; P < 0.001). Coronary obstruction was associated with a high 30-day mortality (52.9% vs. 3.9% in the controls, respectively; P < 0.001). Conclusion: Coronary obstruction following aortic ViV procedures is a life-threatening complication that occurred more frequently in patients with prior stentless or stented bioprostheses with externally mounted leaflets and in those with a short VTC.


Assuntos
Oclusão Coronária/epidemiologia , Tomografia Computadorizada Multidetectores/métodos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Incidência , Masculino , Análise Multivariada , Sistema de Registros , Fatores de Risco
12.
Catheter Cardiovasc Interv ; 92(7): 1404-1411, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30024102

RESUMO

OBJECTIVE: To determine the safety and efficacy of valve-in-valve transcatheter aortic valve replacement (ViV) versus redo surgical aortic valve replacement (SAVR) for the treatment of previously failed aortic bioprostheses. BACKGROUND: Valve-in-valve has emerged as a treatment option for patients with a failed aortic bioprosthesis. Evidence for safety and efficacy remains limited to small studies. METHODS: Medline and Embase were searched to 2017 for studies that directly compared ViV to redo SAVR. A random effects meta-analysis was performed. RESULTS: Four unadjusted (n = 298) and two propensity-matched (n = 200) observational studies were included. Valve-in-valve patients were 2.85-years older (P = 0.03) and were 23% higher in predicted mortality risk (ratio of means: 1.23, 95% confidence interval (95%CI): 1.02-1.48). There was no difference in peri-operative mortality (4.4% vs. 5.7%, P = 0.83;I2 = 0%) or late mortality, reported at median one year follow-up (incident rate ratio (IRR) 0.93, 95%CI: 0.74-1.16, P = 0.51, I2 = 0%) between ViV and redo SAVR. The incidence of permanent pacemaker implantation (8.3% vs 14.6%; P = 0.05;I2 = 0%) and dialysis (3.2% vs. 10.3%; P = 0.03; I2 = 0%) were lower in ViV. There was a reduction in the incidence of severe patient-prosthesis mismatch (3.3% vs 13.5%; P = 0.03; I2 = 0%) and mild or greater paravalvular leak (5.5% vs 21.1%; P = 0.03; I2 = 37%) in the redo SAVR group compared to ViV. CONCLUSIONS: Despite higher predicted surgical risk of ViV patients, there was no difference in mortality but less permanent pacemaker implantation and dialysis compared to redo SAVR. Choice of treatment must be individualized for both anatomical and patient risk factors; in high risk patients with favorable previous prosthesis size, valve-in-valve may be preferred.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Remoção de Dispositivo , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Remoção de Dispositivo/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Desenho de Prótese , Recuperação de Função Fisiológica , Reoperação , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 92(6): 1163-1170, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-30079597

RESUMO

BACKGROUND: Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). OBJECTIVE: The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all-cause mortality after transcatheter aortic valve-in-valve (ViV) implantations, which was not assessed before. METHODS: Using the Valve-in-Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30-day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. RESULTS: Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (± 17.2), 14.59 (± 8.6), and 9.61 (± 8.51), respectively. All three risk scores overestimated 30-day mortality with ratios of 0.176 (95% CI 0.138-0.214), 0.342 (95% CI 0.264-0.419), and 0.536 (95% CI 0.421-0.651), respectively. 30-day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. CONCLUSIONS: All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Técnicas de Apoio para a Decisão , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
J Interv Cardiol ; 31(6): 861-869, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30009390

RESUMO

OBJECTIVE: To compare the safety and efficacy of transcathether aortic valve-in-valve implantation (ViV-TAVI) in degenerated stentless bioprostheses with failed stented valves and degenerated native aortic valves. INTRODUCTION: Little is known about ViV-TAVI in degenerated stentless valves. METHODS: Out of 45 ViV-TAVI procedures reported in the POL-TAVI registry, 20 failed stentless valves were compared with 25 stented prostheses and propensity-matched with 45 native TAVI cases. The mean follow-up was 633 (95% confidence interval [CI], 471-795) days and Valve Academic Research Consortium-2 (VARC-2) definitions were applied. RESULTS: Patients with degenerated stentless valves were younger (65.6, CI 58-73.1 years vs 75.6, CI 72.2-78 [stented] vs 80.1, CI 78.7-81.6 y. [native], P < 0.001). Implantation was required later after surgery (11.5, CI 8-14.9 years) in the stentless cohort as compared with the stented one (6.2, CI 4.7-7.6 years, P = 0.006). ViV-TAVI in the stentless group was also associated with larger amount of contrast (211, CI 157-266 mL vs 135, CI 104-167 mL [stented] vs 132 (119-145) mL [native], P = 0.022). Using VARC-2 composite endpoints, ViV-TAVI in stentless prostheses was characterized by a lower device success (50% vs 76% in stented vs 88.9% in native TAVI, P < 0.001), but comparable early safety up to 30 days (73.7% vs 84% vs 81.8%, respectively, log-rank P = 0.667) and long-term clinical efficacy beyond 30 days (72.2% vs 72% vs 73.8%, respectively, log-rank P = 0.963). CONCLUSIONS: Despite technical challenges and a lower device success, ViV-TAVI in stentless aortic bioprostheses achieves similar safety, efficacy, and functional improvement as in stented or degenerated native valves.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese/efeitos adversos , Desenho de Prótese/métodos , Sistema de Registros , Stents , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Artif Organs ; 42(11): E357-E368, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30198167

RESUMO

Transcatheter aortic valves provide superior systolic hemodynamic performance in terms of valvular pressure gradient and effective orifice area compared with equivalent size surgical bioprostheses. However, in depth investigation of the flow field structures is of interest to examine the flow field characteristics and provide experimental evidence necessary for validation of computational models. The goal of this study was to compare flow field characteristics of the three most commonly used transcatheter and surgical valves using phase-locked particle image velocimetry (PIV). 26-mm Edwards SAPIEN 3, 26-mm Medtronic CoreValve, and 25-mm Carpentier-Edwards PERIMOUNT Magna were examined in a pulse duplicator with input parameters matching ISO-5840, that is, heart rate of 70 beats/min, cardiac output of 5 L/min, and mean aortic pressure of 100 mm Hg. A 2D PIV system was used to obtain flow velocity and viscous shear stress fields during the entire cardiac cycle. In vitro testing showed that the mean transvalvular pressure gradient was lowest for SAPIEN 3, followed by CoreValve, and PERIMOUNT Magna surgical bioprosthesis. In addition, the viscous shear stress magnitude within the jet boundary layer was higher in PERIMOUNT Magna than CoreValve and SAPIEN 3 at the peak of the flow. However, the measured shear stress values were below the known threshold for platelet activation and red blood damage. Therefore, shear-induced platelet activation is unlikely to take place during systole in the three bioprosthetic heart valves. The PIV measurements can be used for verification and validation of computational simulations.


Assuntos
Próteses Valvulares Cardíacas , Hemodinâmica , Hidrodinâmica , Valva Aórtica/cirurgia , Bioprótese , Simulação por Computador , Humanos , Teste de Materiais , Modelos Cardiovasculares , Desenho de Prótese , Reologia , Estresse Mecânico , Substituição da Valva Aórtica Transcateter
16.
Circulation ; 133(16): 1582-93, 2016 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-26994123

RESUMO

BACKGROUND: Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. METHODS AND RESULTS: An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II (P<0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. CONCLUSIONS: TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.


Assuntos
Bioprótese/tendências , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Internacionalidade , Falha de Prótese/tendências , Insuficiência da Valva Tricúspide/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bioprótese/efeitos adversos , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Tempo de Internação/tendências , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico , Adulto Jovem
17.
Catheter Cardiovasc Interv ; 90(7): 1185-1191, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28471090

RESUMO

OBJECTIVES: To evaluate the association between markers of precapillary pulmonary hypertension (PH) and survival in transcatheter aortic valve replacement (TAVR). BACKGROUND: The importance of precapillary PH has been sparsely investigated in patients undergoing TAVR. It may prove an important risk factor for poor outcomes. METHODS: We identified patients at our institution undergoing TAVR with a baseline right heart catheterization (RHC) demonstrating PH. We evaluated the association between markers of precapillary PH and survival including the diastolic pulmonary gradient (DPG), transpulmonary gradient (TPG), and pulmonary vascular resistance (PVR). A multivariable analysis was performed using Cox Proportional Hazards Models, adjusting for age, gender, body mass index, and pulmonary artery systolic pressure (PASP) on echocardiography. RESULTS: We identified 133 patients with PH on RHC. Of these 111 had low DPG and 22 had high DPG. All 3 markers of precapillary PH were associated with worse survival post TAVR, with OR of 2.1 (95% CI 1.1-3.9, P = 0.02), 3.4 (95% CI 1.8-6.4, P < 0.001) and 2.5 (95% CI 1.4-4.5, P = 0.003) for high DPG, TPG, and PVR, respectively. On multivariable analysis, both TPG and PVR remained predictors of worse survival, with OR of 3.4 (95% CI 1.7-6.9, P = 0.001) and 2.5 (95% CI 1.4-4.5, P = 0.003). Echocardiographic PASP and DPG were not predictive of survival. CONCLUSIONS: In patients undergoing TAVR, parameters of precapillary PH are associated with lower survival, and provide incremental prognostication over echocardiographic PASP. RHC should continue to play an important role in risk stratification prior to TAVR. © 2017 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Pressão Arterial , Hipertensão Pulmonar/fisiopatologia , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar , Substituição da Valva Aórtica Transcateter , Resistência Vascular , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Colúmbia Britânica , Cateterismo Cardíaco , Distribuição de Qui-Quadrado , Ecocardiografia , Feminino , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Razão de Chances , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 89(2): 298-305, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27465501

RESUMO

BACKGROUND: The most common reason for reintervention after a Björk modification of the Fontan procedure, in which the right ventricle (RV) is incorporated into the pulmonary circulation by connecting the right atrial (RA) appendage to the RV directly or with an extra-anatomic graft, is obstruction or regurgitation of the RA-RV connection. Transcatheter implantation of a valved stent is an appealing option for the treatment of RA-RV conduit dysfunction in these patients. In the present study, we assessed early and intermediate results after transcatheter valve implantation within an obstructed or regurgitant RA-RV modified Fontan pathway. METHODS: Through a retrospective multicenter registry, we collected data from 16 patients with a modified Fontan circulation who were treated with percutaneous Melody or Sapien valve implantation for dysfunction of an extra-anatomic RA-RV conduit or valve. RESULTS: All patients had successful and uncomplicated implantation of a Melody (n = 15) or Sapien 3 (n = 1) valve with hemodynamic and, in most cases, clinical improvement. During a median follow-up of 3.3 years, 3 patients died of cardiovascular causes unrelated to the procedure or the valve, and no major valve dysfunction was observed. CONCLUSION: Percutaneous transcatheter valve deployment to treat a dysfunctional RA-RV connection after a Björk modification of the Fontan procedure is a viable alternative to surgery, with low procedural risk, and appears to offer good early and intermediate results.© 2016 Wiley Periodicals, Inc.


Assuntos
Implante de Prótese Vascular , Cateterismo Cardíaco/métodos , Técnica de Fontan/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Adulto , Bioprótese , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Canadá , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Europa (Continente) , Feminino , Técnica de Fontan/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
19.
Circulation ; 131(18): 1566-74, 2015 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-25753535

RESUMO

BACKGROUND: We aimed to determine the incidence, predictors, clinical characteristics, management, and outcomes of infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: This multicenter registry included 53 patients (mean age, 79±8 years; men, 57%) who suffered IE after TAVI of 7944 patients after a mean follow-up of 1.1±1.2 years (incidence, 0.67%, 0.50% within the first year after TAVI). Mean time from TAVI was 6 months (interquartile range, 1-14 months). Orotracheal intubation (hazard ratio, 3.87; 95% confidence interval, 1.55-9.64; P=0.004) and the self-expandable CoreValve system (hazard ratio, 3.12; 95% confidence interval, 1.37-7.14; P=0.007) were associated with IE (multivariate analysis including 3067 patients with individual data). The most frequent causal microorganisms were coagulase-negative staphylococci (24%), followed by Staphylococcus aureus (21%) and enterococci (21%). Vegetations were present in 77% of patients (transcatheter valve leaflets, 39%; stent frame, 17%; mitral valve, 21%). At least 1 complication of IE occurred in 87% of patients (heart failure in 68%). However, only 11% of patients underwent valve intervention (valve explantation and valve-in-valve procedure in 4 and 2 patients, respectively). The mortality rate in hospital was 47.2% and increased to 66% at the 1-year follow-up. IE complications such as heart failure (P=0.037) and septic shock (P=0.002) were associated with increased in-hospital mortality. CONCLUSIONS: The incidence of IE at 1 year after TAVI was 0.50%, and the risk increased with the use of orotracheal intubation and a self-expandable valve system. Staphylococci and enterococci were the most common agents. Although most patients presented at least 1 complication of IE, valve intervention was performed in a minority of patients, and nearly half of the patients died during the hospitalization period.


Assuntos
Endocardite Bacteriana/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Infecções Relacionadas à Prótese/etiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/cirurgia , Enterococcus , Contaminação de Equipamentos , Feminino , Infecções por Bactérias Gram-Positivas/etiologia , Infecções por Bactérias Gram-Positivas/cirurgia , Insuficiência Cardíaca/etiologia , Mortalidade Hospitalar , Humanos , Incidência , Intubação Intratraqueal/efeitos adversos , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Modelos de Riscos Proporcionais , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Sistema de Registros , Estudos Retrospectivos , Risco , Infecções Estafilocócicas/etiologia , Infecções Estafilocócicas/cirurgia , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 87(3): 549-50, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26919347

RESUMO

Transcatheter treatment of calcific mitral valve disease with commercially available balloon-expandable valves is feasible Current clinical outcomes are suboptimal, consequently this should be considered only in severely symptomatic patients without other options Purpose-specific mitral valves may allow for this therapy to achieve its full potential.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Mitral/cirurgia , Cateterismo Cardíaco , Próteses Valvulares Cardíacas , Humanos , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA