Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Rev Lett ; 115(25): 250402, 2015 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-26722906

RESUMO

We present a loophole-free violation of local realism using entangled photon pairs. We ensure that all relevant events in our Bell test are spacelike separated by placing the parties far enough apart and by using fast random number generators and high-speed polarization measurements. A high-quality polarization-entangled source of photons, combined with high-efficiency, low-noise, single-photon detectors, allows us to make measurements without requiring any fair-sampling assumptions. Using a hypothesis test, we compute p values as small as 5.9×10^{-9} for our Bell violation while maintaining the spacelike separation of our events. We estimate the degree to which a local realistic system could predict our measurement choices. Accounting for this predictability, our smallest adjusted p value is 2.3×10^{-7}. We therefore reject the hypothesis that local realism governs our experiment.

2.
Opt Express ; 20(4): 3456-66, 2012 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-22418104

RESUMO

We demonstrate a high-accuracy distributed fiber-optic temperature sensor using superconducting nanowire single-photon detectors and single-photon counting techniques. Our demonstration uses inexpensive single-mode fiber at standard telecommunications wavelengths as the sensing fiber, which enables extremely low-loss experiments and compatibility with existing fiber networks. We show that the uncertainty of the temperature measurement decreases with longer integration periods, but is ultimately limited by the calibration uncertainty. Temperature uncertainty on the order of 3 K is possible with spatial resolution of the order of 1 cm and integration period as small as 60 seconds. Also, we show that the measurement is subject to systematic uncertainties, such as polarization fading, which can be reduced with a polarization diversity receiver.

3.
Opt Express ; 17(12): 10290-7, 2009 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-19506682

RESUMO

We demonstrate an all-fiber photon pair source for the critical telecom C-band. We achieve high pair generation rates in excess of 10 MHz while maintaining coincidence-to-accidental ratios (CARs) greater than 100. This is one of the brightest and lowest-noise photon pair sources ever demonstrated. We achieve the high pair rate through CW-pumped spontaneous four-wave mixing in dispersion-shifted fiber. We achieve the high CAR by cooling the fiber to 4 K to suppress the Raman generation and detecting the photons with low jitter and low dark count superconducting single-photon detectors.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Telecomunicações/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Iluminação/instrumentação , Fótons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Opt Express ; 16(13): 9966-77, 2008 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-18575567

RESUMO

We demonstrate an all-fiber photon-pair source with the highest coincidence-to-accidental ratio (CAR) reported to date in the fiber-optic telecom C-band. We achieve this through careful optimization of pairproduction efficiency as well as careful characterization and minimization of all sources of background photons, including Raman generation in the nonlinear fiber, Raman generation in the single-mode fiber, and leakage of pump photons. We cool the nonlinear fiber to 4 K to eliminate most of the Raman scattering, and we reduce other noise photon counts through careful system design. This yields a CAR of 1300 at a pair generation rate of 2 kHz. This CAR is a factor of 12 higher than previously reported results in the C-band. Measured data agree well with theoretical predictions.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Iluminação/instrumentação , Modelos Teóricos , Análise Espectral Raman/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Dinâmica não Linear , Fibras Ópticas , Fótons , Espalhamento de Radiação
5.
J Biomed Opt ; 13(2): 024004, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18465967

RESUMO

We demonstrate the ability of multiple forms of optical coherence tomography (OCT) in the frequency domain to quantitatively size scatterers. Combined with a variety of distinct phantoms, we gain insight into the measurement uncertainties associated with using scattering spectra to size scatterers. We size spherical scatterers on a surface using swept-source OCT with an analysis based on a simple slab-mode resonance model. Automating this technique, a two-dimensional (2-D) image is created by raster scanning across a surface phantom designed to have a distinct size transition to demonstrate accuracy and repeatability. We also investigate the potential of a novel sphere-nanotube structure as a quantitative calibration artifact for use in comparing measured intensity and phase scattering spectra directly to Mie theory predictions. In another experiment, we demonstrate tissue-relevant sizing of scatterers as small as 5 microm on a surface by use of a Fourier domain OCT system with 280 nm of bandwidth from a supercontinuum source. We perform an uncertainty analysis for our high-resolution sizing system, estimating a sizing error of 9% for measurements of spheres with a diameter of 15 microm. With appropriate modifications, our uncertainty analysis has general applicability to other sizing techniques utilizing scattering spectra.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Análise Espectral/métodos , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos , Luz , Espalhamento de Radiação
6.
Opt Express ; 14(18): 8138-53, 2006 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-19529186

RESUMO

We demonstrate a novel technique to determine the size of Mie scatterers with high sensitivity. Our technique is based on spectral domain optical coherence tomography measurements of the dispersion that is induced by the scattering process. We use both Mie scattering predictions and dispersion measurements of phantoms to show that the scattering dispersion is very sensitive to small changes in the size and/or refractive index of the scatterer. We also show the light scattered from a single sphere is, in some cases, non-minimum phase, and therefore the phase of the scattered light is independent of the intensity. Phase dispersion measurements may have application to distinguishing the size and refractive index of scattering particles in biological tissue samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA