BACKGROUND: The subcutaneous implantable-defibrillator (S-ICD) is a relatively new alternative to the transvenous ICD system to minimize intravascular lead-related complications. This paper presents outcome of SICD implantation in patients enrolled in Iran S-ICD registry. METHODS: Between October 2015 and June 2022, this prospective multicenter national registry included 223 patients with a standard indication for an ICD, who neither required bradycardia pacing nor needed cardiac resynchronization to evaluate the early post-implant complications and long-term follow-up results of the S-ICD system. RESULTS: The mean age of the patients was 45 ± 17 years. The majority (79.4%) were male. Ischemic cardiomyopathy (39.5%) was the most common underlying disorder among patients selected for S-ICD implant. Most study patients (68.6%) had ICD for primary prevention of sudden cardiac death. Seven patients (3.1%) were found to have suboptimal lead positions. Six patients (2.7%) developed a pocket hematoma; all were managed medically. During a mean follow-up of 2 years, the appropriate therapy was recorded in 13% of the patients and inappropriate ICD intervention mainly due to supraventricular tachycardia in 8.9%. Pocket infection was observed in four patients (1.8%) and five patients (2.2%) died mainly due to heart failure. CONCLUSION: S-ICDs were effective at detecting and treating both induced and spontaneous ventricular arrhythmias. Major clinical complications were rare.


Assuntos
Desfibriladores Implantáveis , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Irã (Geográfico) , Resultado do Tratamento , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Sistema de Registros
2.
J Cardiovasc Electrophysiol ; 33(1): 117-122, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34674347

RESUMO

INTRODUCTION: Single-center observational studies have shown promising results with fragmented electrogram (FE)-guided ganglionated plexus (GP) ablation in patients with vagally mediated bradyarrhythmia (VMB). We aimed to compare the acute procedural characteristics during FE-guided GP ablation in patients with VMB performed by first-time operators and those of a single high-volume operator. METHODS AND RESULTS: This international multicenter cohort study included data collected over 2 years from 16 cardiac hospitals. The primary operators were classified according to their prior GP ablation experience: a single high-volume operator who had performed > 50 GP ablation procedures (Group 1), and operators performing their first GP ablation cases (Group 2). Acute procedural characteristics and syncope recurrence were compared between groups. Forty-seven consecutive patients with VMB who underwent FE-guided GP ablation were enrolled, n = 31 in Group 1 and n = 16 in Group 2. The mean number of ablation points in each GP was comparable between groups. The ratio of positive vagal response during ablation on the left superior GP was higher in Group 1 (90.3% vs. 62.5%, p = .022). Ablation of the right superior GP increased heart rate acutely without any vagal response in 45 (95.7%) cases. The procedure time was longer in group 2 (83.4 ± 21 vs. 118.0 ± 21 min, respectively, p < .001). Over a mean follow-up duration of 8.0 ± 3 months (range 2-24 months), none of the patients suffered from syncope. CONCLUSION: This multi-center pilot study shows for the first time the feasibility of FE-guided GP ablation across a large group of procedure-naïve operators.