1.
N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37634148

RESUMO

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/classificação , Fibrilação Atrial/cirurgia , Teorema de Bayes , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva , Método Simples-Cego , Taquicardia/etiologia , Resultado do Tratamento
2.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563835

RESUMO

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Compostos Organotiofosforados , Veias Pulmonares , Humanos , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Teorema de Bayes , Estudos Prospectivos , Veias Pulmonares/cirurgia , Ablação por Cateter , Cateterismo
3.
J Cardiovasc Electrophysiol ; 34(1): 135-141, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36300705

RESUMO

INTRODUCTION: BNP elevation in patients with AF is observed in the absence of heart failure; however, prior mechanistic studies have not included direct left atrial pressure measurements. This study sought to understand how emptying function of the left atrial appendage (LAA) and LAA dimension contributes to brain-natriuretic peptide elevations (BNP) in atrial fibrillation (AF) accounting for left atrial pressure (LAP). METHODS: 132 patients referredfor left atrial appendage occlusion (LAAO) were prospectively enrolled in this study. BNP levels and LAP were measured just before LAAO. Statistical analysis considered BNP, rhythm at time of procedure, LAP, LAA morphology, LAA size (ostial diameter, depth, volume), LAA emptying velocity, CHADS2-VASc score, body mass index (BMI), left ventricular ejection fraction (LVEF), estimated glomerular filtration rate (eGFR), and obstructive sleep apnea (OSA) diagnosis as covariates. RESULTS: Bivariate statistical analysis demonstrated positive associations with age, LAA ostial diameter, depth, and volume, LAP, AF status at time of measurement, OSA, and CHADS2-VASc score. BNP was negatively associated with LVEF, eGFR, LAA emptying velocity and BMI. With multivariate logistic regression including LAP as covariate, significant relationships between BNP and AF/AFL(OR 1.99 [1.03, 3.85]), LAP (OR 1.13 [1.06, 1.20]), LAA diameter (OR 1.14 [1.03, 1.27]), LAA depth (OR 1.14 [1.07, 1.22]), and LAA emptying velocity (OR 0.97 [0.96,0.99]) were observed; however, no significant associations were seen with LAA morphology or CHADS2-VASc score. CONCLUSIONS: BNP elevations in AF are associated with LAA size and function, but not CHADS2-VASc score or appendage morphology after accounting for changes in LAP.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Peptídeo Natriurético Encefálico , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/patologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/metabolismo , Ecocardiografia Transesofagiana , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/química , Apneia Obstrutiva do Sono/diagnóstico , Volume Sistólico , Função Ventricular Esquerda
4.
J Chem Inf Model ; 63(7): 2196-2206, 2023 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-36977188

RESUMO

The nation's opioid overdose deaths reached an all-time high in 2021. The majority of deaths are due to synthetic opioids represented by fentanyl. Naloxone, which is a FDA-approved reversal agent, antagonizes opioids through competitive binding at the µ-opioid receptor (mOR). Thus, knowledge of the opioid's residence time is important for assessing the effectiveness of naloxone. Here, we estimated the residence times (τ) of 15 fentanyl and 4 morphine analogs using metadynamics and compared them with the most recent measurement of the opioid kinetic, dissociation, and naloxone inhibitory constants (Mann et al. Clin. Pharmacol. Therapeut. 2022, 120, 1020-1232). Importantly, the microscopic simulations offered a glimpse at the common binding mechanism and molecular determinants of dissociation kinetics for fentanyl analogs. The insights inspired us to develop a machine learning approach to analyze the kinetic impact of fentanyl's substituents based on the interactions with mOR residues. This proof-of-concept approach is general; for example, it may be used to tune ligand residence times in computer-aided drug discovery.


Assuntos
Analgésicos Opioides , Naloxona , Analgésicos Opioides/farmacologia , Naloxona/farmacologia , Naloxona/metabolismo , Fentanila/metabolismo , Fentanila/farmacologia , Morfina/química , Receptores Opioides mu/metabolismo , Antagonistas de Entorpecentes
5.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37584233

RESUMO

AIMS: Incomplete left atrial appendage occlusion (LAAO) due to peri-device leak (PDL) is a limitation of the therapy. The Amulet IDE trial is the largest randomized head-to-head trial comparing the Amulet and Watchman 2.5 LAAO devices with fundamentally different designs. The predictors and mechanistic factors impacting differences in PDLs within the Amulet IDE trial are assessed in the current analysis. METHODS AND RESULTS: An independent core lab analysed all images for the presence or absence of severe PDL (>5 mm). The incidence, mechanistic factors, predictors using propensity score-matched controls, and evolution of severe PDLs through 18 months were assessed. Of the 1878 patients randomized in the trial, the Amulet occluder had significantly fewer severe PDLs than the Watchman device at 45 days (1.1 vs. 3.2%, P < 0.001) and 12 months (0.1 vs. 1.1%, P < 0.001). Off-axis deployment or missed lobes were leading mechanistic PDL factors in each device group. Larger left atrial appendage (LAA) dimensions including orifice diameter, landing zone diameter, and depth predicted severe PDL with the Watchman device, with no significant anatomical limitations noted with the Amulet occluder. Procedural and device implant predictors were found with the Amulet occluder attributed to the learning curve with the device. A majority of Watchman device severe PDLs did not resolve over time through 18 months. CONCLUSION: The dual-occlusive Amplatzer Amulet LAA occluder provided improved LAA closure compared with the Watchman 2.5 device. Predictors and temporal observations of severe PDLs were identified in the Amulet IDE trial. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov Unique identifier NCT02879448.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Dispositivo para Oclusão Septal/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Acidente Vascular Cerebral/etiologia
6.
Circulation ; 144(19): 1543-1552, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34459659

RESUMO

BACKGROUND: Percutaneous closure of the left atrial appendage (LAA) is an alternative to chronic oral anticoagulation to reduce stroke risk in patients with nonvalvular atrial fibrillation. The Amulet IDE trial (Amplatzer Amulet Left Atrial Appendage Occluder IDE Trial) was designed to evaluate the safety and effectiveness of the dual-seal mechanism of the Amulet LAA occluder compared with the Watchman device. METHODS: Patients with nonvalvular atrial fibrillation at increased risk of stroke were randomly assigned (1:1) to undergo percutaneous implantation of a LAA occluder with the Amulet occluder or Watchman device. The primary end points included safety (composite of procedure-related complications, all-cause death, or major bleeding at 12 months), effectiveness (composite of ischemic stroke or systemic embolism at 18 months), and the rate of LAA occlusion at 45 days. Prespecified secondary end points included a composite of all stroke, systemic embolism, or cardiovascular/unexplained death at 18 months, major bleeding at 18 months, and superiority test of the 3 primary end points. RESULTS: A total of 1878 patients were enrolled. The Amulet occluder was noninferior to the Watchman device for the primary safety end point (14.5% versus 14.7%; difference=-0.14 [95% CI, -3.42 to 3.13]; P<0.001 for noninferiority). Major bleeding and all-cause death were similar between groups (10.6% versus 10.0% and 3.9% versus 5.1%, respectively). Procedure-related complications were higher for the Amulet occluder (4.5% versus 2.5%), largely related to more frequent pericardial effusion and device embolization. The Amulet occluder was noninferior to the Watchman device for the primary effectiveness end point (2.8% versus 2.8%; difference=0.00 [95% CI, -1.55 to 1.55]; P<0.001 for noninferiority), and the composite of stroke, systemic embolism, or cardiovascular/unexplained death (5.6% versus 7.7%, difference=-2.12 [95% CI, -4.45 to 0.21]; P<0.001 for noninferiority). The rate of major bleeding was similar between groups (11.6% versus 12.3%; difference=-0.71 [95% CI, -3.72 to 2.31]; P=0.32 for superiority). LAA occlusion was higher for the Amulet occluder than for the Watchman device (98.9% versus 96.8%; difference=2.03 [95% CI, 0.41-3.66]; P<0.001 for noninferiority; P=0.003 for superiority). CONCLUSIONS: The Amulet occluder was noninferior for safety and effectiveness of stroke prevention for nonvalvular atrial fibrillation compared with the Watchman device and superior for LAA occlusion. Procedure-related complications were higher with the Amulet occluder and decreased with operator experience. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02879448.


Assuntos
Dispositivo para Oclusão Septal/normas , Acidente Vascular Cerebral/terapia , Idoso , Feminino , Humanos , Masculino
7.
J Cardiovasc Electrophysiol ; 33(8): 1881-1887, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35175683

RESUMO

Recently receiving Food and Drug Administration approval, the Amplatzer Amulet™ left atrial appendage occluder device (Abbott Medical Inc.) provides a dual seal mechanism alternative to the commercially available Watchman FLX or Watchman 2.5 device for embolic stroke prevention in patients with nonvalvular atrial fibrillation. This step-by-step review will cover patient selection, preprocedure imaging assessment, device sizing, device preparation, implant target position assessment, implant technique and troubleshooting, and immediate postimplant follow-up.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
8.
Europace ; 24(7): 1119-1126, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35025987

RESUMO

AIMS: There is limited information on what clinical factors are associated with the development of pericardial effusion after leadless pacemaker implantation. We sought to determine predictors of and to develop a risk score for pericardial effusion in patients undergoing Micra leadless pacemaker implantation attempt. METHODS AND RESULTS: Patients (n = 2817) undergoing implant attempt from the Micra global trials were analysed. Characteristics were compared between patients with and without pericardial effusion (including cardiac perforation and tamponade). A risk score for pericardial effusion was developed from 18 pre-procedural clinical variables using lasso logistic regression. Internal validation and future prediction performance were estimated using bootstrap resampling. The scoring system was also externally validated using data from the Micra Acute Performance European and Middle East (MAP EMEA) registry. There were 32 patients with a pericardial effusion [1.1%, 95% confidence interval (CI): 0.8-1.6%]. Following lasso logistic regression, 11 of 18 variables remained in the model from which point values were assigned. The C-index was 0.79 (95% CI: 0.71-0.88). Patient risk score profile ranged from -4 (lowest risk) to 5 (highest risk) with 71.8% patients considered low risk (risk score ≤0), 16.6% considered medium risk (risk score = 1), and 11.7% considered high risk (risk score ≥2) for effusion. The median C-index following bootstrap validation was 0.73 (interquartile range: 0.70-0.75). The C-index based on 9 pericardial effusions from the 928 patients in the MAP EMEA registry was 0.68 (95% CI: 0.52-0.83). The pericardial effusion rate increased significantly with additional Micra deployments in medium-risk (P = 0.034) and high-risk (P < 0.001) patients. CONCLUSION: The overall rate of pericardial effusion following Micra implantation attempt is 1.1% and has decreased over time. The risk of pericardial effusion after Micra implant attempt can be predicted using pre-procedural clinical characteristics with reasonable discrimination. CLINICAL TRIAL REGISTRATION: The Micra Post-Approval Registry (ClinicalTrials.gov identifier: NCT02536118), Micra Continued Access Study (ClinicalTrials.gov identifier: NCT02488681), and Micra Transcatheter Pacing Study (ClinicalTrials.gov identifier: NCT02004873).


Assuntos
Marca-Passo Artificial , Derrame Pericárdico , Ensaios Clínicos como Assunto , Desenho de Equipamento , Humanos , Marca-Passo Artificial/efeitos adversos , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/epidemiologia , Derrame Pericárdico/etiologia , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
9.
Circulation ; 139(20): e967-e989, 2019 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-30943783

RESUMO

Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure with reduced ejection fraction. Although these devices effectively improve survival, atrial and ventricular arrhythmias are common, predispose these patients to additional risk, and complicate patient management. However, there is no consensus on best practices for the medical management of these arrhythmias or on the optimal timing for procedural interventions in patients with refractory arrhythmias. Although the vast majority of these patients have preexisting cardiovascular implantable electronic devices or cardiac resynchronization therapy, given the natural history of heart failure, it is common practice to maintain cardiovascular implantable electronic device detection and therapies after LVAD implantation. Available data, however, are conflicting on the efficacy of and optimal device programming after LVAD implantation. Therefore, the primary objective of this scientific statement is to review the available evidence and to provide guidance on the management of atrial and ventricular arrhythmias in this unique patient population, as well as procedural interventions and cardiovascular implantable electronic device and cardiac resynchronization therapy programming strategies, on the basis of a comprehensive literature review by electrophysiologists, heart failure cardiologists, cardiac surgeons, and cardiovascular nurse specialists with expertise in managing these patients. The structure and design of commercially available LVADs are briefly reviewed, as well as clinical indications for device implantation. The relevant physiological effects of long-term exposure to continuous-flow circulatory support are highlighted, as well as the mechanisms and clinical significance of arrhythmias in the setting of LVAD support.


Assuntos
Arritmias Cardíacas/terapia , Baixo Débito Cardíaco/terapia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Baixo Débito Cardíaco/etiologia , Terapia de Ressincronização Cardíaca , Ablação por Cateter , Desfibriladores Implantáveis , Desenho de Equipamento , Falha de Equipamento , Átrios do Coração/fisiopatologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Humanos , Comunicação Interdisciplinar , Relações Profissional-Família , Análise de Sobrevida
10.
J Cardiovasc Electrophysiol ; 31(3): 718-722, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32003095

RESUMO

INTRODUCTION: The optimal approach to the extraction of leads with large vegetations remains uncertain. METHODS: High-risk patients with lead associated vegetations undergoing device extraction at Vanderbilt Hospital with concomitant use of the Penumbra Aspiration System (Penumbra Inc, Alameda, CA) are described. An 8.5 Fr Agilis NXT (Abbott Inc, St. Paul, MN) was advanced to the right atrium, through which a Penumbra Indigo Cat-8 catheter was advanced. Using intracardiac echocardiography, the Penumbra was positioned directly on the vegetation, suction was applied until adherent, and the Indigo catheter and Agilis sheath were then removed en-bloc and aspirated debris flushed out. This was repeated until debulking was considered successful. RESULTS: Eight cases were performed. The median vegetation size was 2 cm. Pathogens were Enterococcus, Staphylococcus, Candida, Cutibacterium, and Enterobacter. In seven of eight cases, aspiration successfully reduced vegetations to less than 1 cm before successful percutaneous cardiac implantable electronic device removal. One patient underwent surgical removal via thoracotomy. There were no acute complications related to the Penumbra catheter. Three patients had CT evidence of small pulmonary emboli postprocedure. The length of stay was 3 to 27 days. One patient died on POD 1 of refractory ventricular tachycardia unrelated to the procedure. One patient died of ongoing sepsis 2 weeks postextraction. CONCLUSIONS: The Penumbra Indigo Aspiration system can be useful for vegetation debulking before transvenous lead extraction.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/instrumentação , Endocardite Bacteriana/cirurgia , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Trombectomia/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Remoção de Dispositivo/efeitos adversos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/microbiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Fatores de Risco , Sucção/instrumentação , Trombectomia/efeitos adversos , Resultado do Tratamento
11.
N Engl J Med ; 374(6): 533-41, 2016 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-26551877

RESUMO

BACKGROUND: A leadless intracardiac transcatheter pacing system has been designed to avoid the need for a pacemaker pocket and transvenous lead. METHODS: In a prospective multicenter study without controls, a transcatheter pacemaker was implanted in patients who had guideline-based indications for ventricular pacing. The analysis of the primary end points began when 300 patients reached 6 months of follow-up. The primary safety end point was freedom from system-related or procedure-related major complications. The primary efficacy end point was the percentage of patients with low and stable pacing capture thresholds at 6 months (≤2.0 V at a pulse width of 0.24 msec and an increase of ≤1.5 V from the time of implantation). The safety and efficacy end points were evaluated against performance goals (based on historical data) of 83% and 80%, respectively. We also performed a post hoc analysis in which the rates of major complications were compared with those in a control cohort of 2667 patients with transvenous pacemakers from six previously published studies. RESULTS: The device was successfully implanted in 719 of 725 patients (99.2%). The Kaplan-Meier estimate of the rate of the primary safety end point was 96.0% (95% confidence interval [CI], 93.9 to 97.3; P<0.001 for the comparison with the safety performance goal of 83%); there were 28 major complications in 25 of 725 patients, and no dislodgements. The rate of the primary efficacy end point was 98.3% (95% CI, 96.1 to 99.5; P<0.001 for the comparison with the efficacy performance goal of 80%) among 292 of 297 patients with paired 6-month data. Although there were 28 major complications in 25 patients, patients with transcatheter pacemakers had significantly fewer major complications than did the control patients (hazard ratio, 0.49; 95% CI, 0.33 to 0.75; P=0.001). CONCLUSIONS: In this historical comparison study, the transcatheter pacemaker met the prespecified safety and efficacy goals; it had a safety profile similar to that of a transvenous system while providing low and stable pacing thresholds. (Funded by Medtronic; Micra Transcatheter Pacing Study ClinicalTrials.gov number, NCT02004873.).


Assuntos
Arritmias Cardíacas/terapia , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrodos Implantados , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Adulto Jovem
12.
J Cardiovasc Electrophysiol ; 30(11): 2501-2507, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31515883

RESUMO

INTRODUCTION: Hyponatremia commonly follows percutaneous exclusion of the left atrial appendage (LAA) with the LARIAT suture delivery device. The aim of this study was to evaluate for clinical predictors hyponatremia following ligation of the appendage with the LARIAT device. METHODS AND RESULTS: A retrospective analysis was conducted on 61 consecutive patients (average age 69.7 ± 9.8 years, 55.7% male) who underwent successful appendage ligation with the LARIAT device. Acute hyponatremia (AH) was defined as a drop in serum sodium (Na) by greater than or equal to 4 mmol/L within 48 hours of ligation while exaggerated acute hyponatremia (EAH) was defined as a drop greater than or equal to 10 mmol/L. Among all patients, there was a significant decrease in [Na] at 24 hours (3.26 ± 2.77 mmol/L) and 48 hours (4.98 ± 3.74 mmol/L). Thirty-two patients (52.4%) had AH while six patients (9.8%) experienced EAH. A body mass index (BMI) of less than 28.4 kg/m2 was associated with AH (P = .037) while a BMI < 25 kg/m2 was associated with EAH (P = .021). A linear regression analysis comparing the maximum sodium decrease to the indexed left atrial (LA) diameter found that for every 1 cm/m2 increase in indexed LA diameter, there was a 2.5 mEq/L decrease in serum sodium (P = .04). CONCLUSIONS: Hyponatremia frequently occurs following LAA ligation with the LARIAT device. A low BMI < 25 kg/m2 is associated with a drop in serum sodium of greater than 10 mmol/L while increasing indexed LA diameter predicts any AH. AH is also associated with a significantly lower systolic blood pressure 48 to 72 hours post LAA exclusion with the LARIAT device.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Hiponatremia/etiologia , Sódio/sangue , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Biomarcadores/sangue , Pressão Sanguínea , Índice de Massa Corporal , Feminino , Humanos , Hiponatremia/sangue , Hiponatremia/diagnóstico , Ligadura , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
Pacing Clin Electrophysiol ; 42(7): 965-969, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31045260

RESUMO

BACKGROUND: Boston Scientific (Marlborough, MA, USA) implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds) manufactured between 2008 and 2014 are potentially subject to premature battery depletion through a low-voltage capacitor malfunction occurring as a result of hydrogen buildup within the device. Although some of these devices are currently under advisory, other devices manufactured during this timeframe carry a lower risk of the same malfunction. These same devices are known to have superior longevity in general, and the overall mean lifespan of the devices remains long. METHODS: All patients implanted or followed at our two centers who experienced premature battery depletion and had a Boston Scientific ICD or CRT-D potentially at risk for low-voltage capacitor malfunction were studied retrospectively. RESULTS: Nineteen out of 838 patients (2.3%) with devices potentially at risk have had premature battery depletion: 5.7% of those under advisory and 1.1% of those not under advisory. None of our patients had compromised therapy, and all had >27 days of projected battery longevity remaining. CONCLUSIONS: Undetected premature battery depletion in this population of ICDs has the potential to expose a patient to an interval of time where the device is unable to provide therapy. However, with enrollment in remote monitoring, regular follow-up, and attention to audible alerts, the risk of therapy loss due to low-voltage state can be effectively mitigated. For these reasons, prophylactic generator replacement is not recommended.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Fontes de Energia Elétrica , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Retrospectivos
15.
J Cardiovasc Electrophysiol ; 29(1): 17-21, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28877379

RESUMO

INTRODUCTION: Left atrial appendage (LAA) closure with the WATCHMAN device, according to FDA labelling, is recommended in patients with a maximal LAA ostial width between 17 and 31 mm. The safety and efficacy of LAA closure in patients with a maximal LAA ostial width < 17 mm has not been evaluated. The goal of this study was to determine the acute and short-term safety and efficacy of LAA closure with the WATCHMAN device in patients with a maximal LAA ostial width < 17 mm. METHODS AND RESULTS: Thirty-two consecutive patients with a maximal LAA ostial width < 17 mm as determined by a screening transesophageal echocardiogram (TEE) underwent LAA closure with the WATCHMAN device between March 2015 and November 2016 at five medical centers, and were included in this study. Mean age, body mass index (BMI), and CHA2 DS2 -VASC score were 70.8 ± 8.6 years, 29.3 ± 6.5 kg/m2 , and 3.9 ±1.2, respectively. At the screening TEE, mean maximal LAA ostial width and depth were 15.6 ± 0.6 mm (range 14-16) and 23.2 ± 4.5 mm (range 13-31), respectively. Successful LAA closure with the WATCHMAN device was achieved in 31 of 32 patients (97%), with no major complications. TEE performed 45 days after LAA closure demonstrated no peridevice leak > 5 mm and no device related thrombi. Warfarin was discontinued in all 31 patients 45 days after LAA closure. CONCLUSIONS: LAA closure with the WATCHMAN device can be successfully and safely achieved in patients with a maximal LAA ostial width < 17 mm.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Potenciais de Ação , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Bases de Dados Factuais , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Desenho de Equipamento , Frequência Cardíaca , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
J Comput Chem ; 38(15): 1260-1269, 2017 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-28370344

RESUMO

BACE1 is a major therapeutic target for prevention and treatment of Alzheimer's disease. Developing inhibitors that can selectively target BACE1 in favor of other proteases, especially cathepsin D (CatD), has presented significant challenges. Here, we investigate the conformational dynamics and protonation states of BACE1 and CatD using continuous constant pH molecular dynamics with pH replica-exchange sampling protocol. Despite similar structure, BACE1 and CatD exhibit markedly different active site dynamics. BACE1 displays pH-dependent flap dynamics that controls substrate accessibility, while the CatD flap is relatively rigid and remains open in the pH range 2.5-6. Interestingly, although each protease hydrolyzes peptide bonds, the protonation states of the catalytic dyads are different within the active pH range. The acidic and basic components of the BACE1 catalytic dyad are clear, while either aspartic acid of the CatD catalytic dyad could play the role of acid or base. Finally, we investigate binding of the inhibitor LY2811376 developed by Eli Lilly to BACE1 and CatD. Surprisingly, in the enzyme active pH range, LY2811376 forms a stronger salt bridge with the catalytic dyad in CatD than in BACE1, which might explain the retinal toxicity of the inhibitor related to off-target inhibition of CatD. This work highlights the complexity and challenge in structure-based drug design where receptor-ligand binding induces protonation state change in both the protein and the inhibitor. © 2017 Wiley Periodicals, Inc.


Assuntos
Secretases da Proteína Precursora do Amiloide/antagonistas & inibidores , Secretases da Proteína Precursora do Amiloide/metabolismo , Ácido Aspártico Endopeptidases/antagonistas & inibidores , Ácido Aspártico Endopeptidases/metabolismo , Catepsina D/metabolismo , Inibidores Enzimáticos/farmacologia , Bibliotecas de Moléculas Pequenas/farmacologia , Doença de Alzheimer/tratamento farmacológico , Doença de Alzheimer/metabolismo , Sequência de Aminoácidos , Secretases da Proteína Precursora do Amiloide/química , Ácido Aspártico Endopeptidases/química , Domínio Catalítico/efeitos dos fármacos , Catepsina D/antagonistas & inibidores , Catepsina D/química , Desenho de Fármacos , Inibidores Enzimáticos/química , Humanos , Simulação de Dinâmica Molecular , Ligação Proteica , Conformação Proteica/efeitos dos fármacos , Bibliotecas de Moléculas Pequenas/química
17.
Pacing Clin Electrophysiol ; 40(6): 644-647, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28369957

RESUMO

Transvenous leads are a known source of iatrogenic tricuspid regurgitation. It is commonly held that extraction of chronic pacing and defibrillator leads will not reduce this, due to the inevitable trauma to the valve associated with the procedure. We demonstrate three cases of clinically significant reductions in tricuspid regurgitation after extraction of leads that were looped across the tricuspid valve.


Assuntos
Remoção de Dispositivo/métodos , Eletrodos Implantados/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/prevenção & controle , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem
18.
J Cardiovasc Electrophysiol ; 32(3): 726-728, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33533146
19.
J Cardiovasc Electrophysiol ; 27(4): 428-34, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26725742

RESUMO

INTRODUCTION: Totally thoracoscopic (TT) epicardial ablation combined with endocardial catheter ablation is an emerging treatment for persistent AF. The effects of timing of the TT and endocardial portion on AT/AF recurrence are not known. METHODS: We retrospectively analyzed patients undergoing TT staged versus simultaneous hybrid AF ablation at our institution. Arrhythmia-free outcome was compared using time to recurrence (AF or AT greater than 30 seconds after a 3-month blanking period from endocardial ablation) at 12 months. All subjects had continuous ILR or PM monitoring. RESULTS: Eighty-three patients (52 same-day, 31 staged) underwent TT hybrid AF ablation. Recurrence was observed in 23 (29%) patients at a median time of 147 days (IQR 91,238). In univariate analysis, a staged approach significantly increased the likelihood of detecting incomplete PVI (OR 6 [95% CI 2-17] P = 0.001). However, only longstanding persistent AF (LSP-AF) status predicted recurrence (HR 4 [95% CI 1.4-12] P = 0.01). Neither a staged approach (HR 1.0 [95% CI 0.4-2.4] P = 0.9), nor detection of incomplete PVI (HR 0.9 [95% CI 0.4-2.3] P = 0.8) predicted time to first AF/AT recurrence. CONCLUSIONS: Staged hybrid ablation of AF significantly increases the likelihood of discovering incomplete PVI at the time of endocardial mapping versus a same-day procedure. However, the staged approach did not improve time to first AT/AF recurrence.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Toracoscopia/métodos , Toracoscopia/estatística & dados numéricos , Idoso , Fibrilação Atrial/diagnóstico , Doença Crônica , Terapia Combinada/métodos , Terapia Combinada/estatística & dados numéricos , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Recidiva , Reoperação/métodos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Tennessee/epidemiologia , Resultado do Tratamento
20.
J Cardiovasc Electrophysiol ; 27(1): 60-4, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26515657

RESUMO

INTRODUCTION: Left atrial appendage (LAA) can be effectively and safely excluded using a novel percutaneous LARIAT ligation system. However, due to pericardial catheter manipulation and LAA ligation and subsequent necrosis, postprocedural course is complicated by pericarditis. We intended to evaluate the preprocedural use of colchicine on the incidence of postprocedural pericardial complications. METHODS AND RESULTS: In this multicenter observational study, we included all consecutive patients who underwent LARIAT procedure at the participating centers. Many patients received periprocedural colchicine at the discretion of the physician. We compared the postprocedural outcomes of patients who received prophylactic periprocedural colchicine (colchicine group) with those who did not receive colchicine (standard group). A total of 344 consecutive patients, 243 in the "colchicine group" and 101 in the "standard group," were included. The mean age, median CHADS2VASc score, and HASBLED scores were 70 ± 11 years, 3 ± 1.7, and 3 ± 1.1, respectively. There were no significant differences in major baseline characteristics between the two groups. Severe pericarditis was significantly lower in the "colchicine group" compared to the "standard group" (10 [4%] vs. 16 [16%] P<0.0001). The colchicine group, compared to the standard group, had lesser pericardial drain output (186 ± 84 mL vs. 351 ± 83, P<0.001), shorter pericardial drain duration (16 ± 4 vs. 23 ± 19 hours, P<0.04), and similar incidence of delayed pericardial effusion (4 [1.6%] to 3 [3%], P = 0.42) when compared to the standard group. CONCLUSION: Use of colchicine periprocedurally was associated with significant reduction in postprocedural pericarditis and associated complications.


Assuntos
Anti-Inflamatórios/administração & dosagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Colchicina/administração & dosagem , Pericardite/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Feminino , Humanos , Ligadura , Masculino , Pessoa de Meia-Idade , Pericardite/diagnóstico , Pericardite/etiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Estados Unidos