Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Europace ; 21(5): 724-731, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30649273

RESUMO

AIMS: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) may define left atrial (LA) anatomy and structural remodelling, and facilitate atrial fibrillation (AF) ablation. We aimed to assess the intra- and inter-observer reproducibility and agreement of LGE-CMR parameters with direct application to AF ablation techniques. METHODS AND RESULTS: One experienced and one non-experienced observer performed complete LGE-CMR data analysis twice, on different days, in 40 randomly selected LGE-CMR examinations [20 performed before ablation (pre-ablation) and 20 performed 3 months after ablation (post-ablation)]. Four additional observers (two experienced and two non-experienced) performed complete LGE-CMR data analysis in a subgroup of 30 patients (15 pre-ablation and 15 post-ablation). All LGE-CMR were performed in sinus rhythm. Intra- and inter-observer reproducibility of LA volume, LA area, and sphericity index (SI) was high: coefficient of variation <10% and intraclass correlation coefficient >0.71. Geometric congruency of repeated reconstruction of LA shape was high: maximal error <5 mm for intra-observer and <8 mm for inter-observer. The precision of scar location increased with extent of scar, and was high (Dice coefficient >0.75) when the scar area was >5 cm2 for a single observer and >15 cm2 for multiple observers. Non-experienced observers performed equally well to experienced observers. CONCLUSION: Late gadolinium enhancement cardiac magnetic resonance measurements of LA area, volume, and SI were reproducible, and geometric congruency of LA shape was high. Location of scar was precise for scar areas >5 cm2 for single observers and >15 cm2 for multiple observers, regardless of the observers' experience. These results may serve as a reference for future studies on the role for substrate-based AF ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter/métodos , Gadolínio/farmacologia , Átrios do Coração , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Remodelamento Atrial , Meios de Contraste/farmacologia , Feminino , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/métodos , Reprodutibilidade dos Testes
2.
J Cardiovasc Electrophysiol ; 29(8): 1065-1072, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29722466

RESUMO

INTRODUCTION: The purpose of this study was to compare the anatomical characteristics of scar formation achieved by visual-guided laser balloon (Laser) and radiofrequency (RF) pulmonary vein isolation (PVI), using late-gadolinium-enhanced cardiac magnetic resonance imaging (LGE-CMR). METHODS AND RESULTS: We included 17 patients with paroxysmal or early persistent drug resistant AF who underwent Laser ablation; 2 were excluded due to procedure-related complications. The sample was matched with a historical group of 15 patients who underwent PVI using RF. LGE-CMR sequences were acquired before and 3 months post-PVI. Ablation gaps were defined as pulmonary vein (PV) perimeter sections showing no gadolinium enhancement. The number of ablation gaps was lower in Laser versus RF ablations (median 7 vs. 14, P  =  0.015). Complete anatomical PVI (circumferential scar around PV, without gaps) was more frequently achieved with Laser than with RF (39% vs. 19% of PVs, P  =  0.025). Fewer gaps were present at the superior and anterior left PV and posterior right PV antral regions in the Laser group, compared to RF. Scar extension into the PVs was similar in both groups, although RF produced more extensive ablation scar toward the LA body. AF recurrences at 1 year were similar in both groups (Laser 36% vs. RF 27%, P  =  1.00). CONCLUSIONS: Compared to RF, Laser ablation achieved more complete anatomical PVI, with less LA scar extension. However, AF recurrence appears to be similar after Laser compared to RF ablation. Further studies are needed to assess whether the anatomical advantages of Laser ablation translate into clinical benefit in patients with AF.


Assuntos
Gadolínio , Imagem Cinética por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Ablação por Radiofrequência/tendências , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Coortes , Feminino , Seguimentos , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/tendências , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/efeitos adversos
3.
Circ Arrhythm Electrophysiol ; 11(12): e006659, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30562102

RESUMO

BACKGROUND: There is limited knowledge about the impact of anatomic gaps as assessed by delayed gadolinium enhancement cardiac magnetic resonance on atrial fibrillation (AF) recurrence after first pulmonary vein (PV) isolation. METHODS: Consecutive patients underwent delayed gadolinium enhancement cardiac magnetic resonance 3 months after radiofrequency circumferential PV isolation. Delayed gadolinium enhancement cardiac magnetic resonance images were assessed from 360 PV resulting in 2880 segments in the 2×8-segment model from 94 patients (52±11 years, 62% paroxysmal AF). Left atria were segmented using dedicated software. Anatomic gap was defined as discontinuation of the ablation line by ≥3 mm. Relative gap length was calculated as absolute gap length divided by the total length of the ablation line. AF recurrence was assessed after a mean follow-up duration of 15±10 months Results: Mean number of anatomic gaps was 5.4 per patient. Recurrence within the first year of ablation was observed in 21 patients with paroxysmal AF (36%) and 19 patients with persistent AF (53%). In the univariate analysis, CHA2DS2-VASc score, AF type, and relative gap length were predictive of recurrence. In the multivariate analysis, only relative gap length was significantly associated with recurrence (hazard ratio, 1.16 [1.02-1.31] per each 10% of gap). CONCLUSIONS: The total relative gap length but not the number of anatomic gaps in the PV ablation line as assessed by delayed gadolinium enhancement cardiac magnetic resonance was associated with AF recurrence 1 year after first PV isolation. An increase of 10% relative gap length increased the likelihood of AF recurrence by 16%.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Gadolínio , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Veias Pulmonares/cirurgia , Adulto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/mortalidade , Ablação por Cateter/mortalidade , Estudos de Coortes , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Recidiva , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Espanha , Estatísticas não Paramétricas , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA