RESUMO
Aiming at the difficulty of detecting the modulation transfer function (MTF) of Bayer color cameras during focusing, the traditional scheme is modified in this paper. First, through analysis, it is found that the MTF of the Bayer detector decreased substantially compared to the monochromatic detector, which was caused by the loss of a large amount of light from the Bayer detector. When the MTF is calculated for the color image after de-mosaicing, the degradation of image quality leads to the inability to obtain the full-frequency MTF curve. Therefore, this paper proposes a solution to detect the MTFs of the three primary colors in the Bayer image individually, and then weight the MTFs of each primary color to obtain the MTF of the color image based on the calibration results of the light source. Then, considering the steps of differentiation and Fourier transform in the slanted-edge method, this paper solves the problem of non-uniform sampling of edge spread function by using the modification of the slanted-edge method with non-uniform Fourier transform. Finally, the optimal imaging position of a certain type of Bayer color camera is determined using the methods proposed in this paper. Simulation and test results verify the effectiveness and accuracy of the methods in this paper.
RESUMO
Bayer filter color cameras are more and more widely used in the field of aerospace remote sensing, but the Bayer filter causes great degradation in image quality; therefore, obtaining a means of achieving the high-precision measurement of the modulation transfer function (MTF) of Bayer filter color cameras is an urgent problem. In order to solve this problem, this paper develops a slanted-edge method via three steps: the detection of the slanted edge, the acquisition and processing of the edge spread function (ESF), and the acquisition and processing of the line spread function (LSF). A combination of the Canny operator and Hough transform is proposed for the detection of the slanted edge, which improves the fitting accuracy and anti-interference ability of the algorithm. Further, the Canny operator is improved by constructing an adaptive filter function and introducing the Otsu method, which can more effectively smooth the image and remove its false edges. A method of processing ESF data by combining cubic spline interpolation and Savitzky-Golay (SG) filtering is proposed, which reduces the effects of noise and the non-uniform sampling of ESF on MTF. A method of LSF processing using Gaussian function fitting is proposed to further reduce the effect of noise on MTF. The improved algorithm is verified by the MTF measurement test applied to a specific type of Bayer filter color space camera. The simulation and test results show that the improved slanted-edge method discussed in this paper has greater precision and a better anti-interference ability, and it can effectively solve the difficult problem associated with MTF detection in Bayer filter color space cameras.
RESUMO
The stray-light suppression of a large off-axis three-mirror anastigmatic space camera has been a hot topic, and this study proposes a composite stray-light suppression strategy that effectively suppresses stray light using the combination of a baffle, retaining ring, and internal antistray light measures. Additionally, the light barrier of the third mirror with a three-layered structure was designed to further optimize the composite stray-light suppression system. At the stray-light simulation analysis stage, in view of the limitations of the Torrance-Sparrow scattering analysis model, an analysis model with wide adaptability is proposed, which can be applied to the stray-light simulation analysis of large-size mirrors with rough surfaces. The simulation results indicate that the point source transmittance of the composite stray-light suppression strategy proposed in this paper is of the order of 10-5 before installing the light barrier of the third mirror, and the veiling glare index of the full field of view is less than 5.8%. After installing the light barrier of the third mirror, the point source transmittance reached the order of 10-8, and the veiling glare index of the full field of view was less than 1.31%. Moreover, the influence of the light barrier of the third mirror on the modulation transfer function of the system was less than 2.3%. The modulation transfer function test of the large-width off-axis three-mirror anastigmatic space camera in a simulated vacuum on-orbit environment was completed, and the test results indicated that the negative impact of the light barrier of the third mirror on the modulation transfer function was less than 3.6%. Moreover, an out-of-field imaging test of the space camera was conducted and the results showed that the image was clear, and the SNR reached 80 dB. The simulation and experimental results prove that the solution in this study can effectively solve the problem of stray-light suppression for large off-axis three-mirror anastigmatic space cameras.