Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Vasc Med ; 17(4): 223-30, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22738758

RESUMO

We studied associations of the number and size of magnetic resonance angiography (MRA)-assessed lower extremity collateral vessels with the ankle-brachial index (ABI), severity of superficial femoral artery (SFA) plaque, and leg symptoms in participants with peripheral artery disease (PAD). A total of 303 participants with PAD underwent time-resolved MRA at the thigh station. Collaterals were categorized by number (Category 1: 0-3 collaterals; Category 2: 4-7 collaterals; Category 3: ≥ 8 collateral vessels) and size (Grade 1: ≤ 5 small collaterals; Grade 2: > 5 small vessels; Grade 3: ≤ 5 large collaterals; Grade 4: > 5 large collaterals). Adjusting for age, sex, race, comorbidities and other covariates, more numerous collateral vessels were associated with lower ABI values (Category 1: 0.79; Category 2: 0.67; Category 3: 0.60; p trend < 0.001). Similarly, larger collateral vessels were associated with lower ABI values (Grade 1: 0.75; Grade 2: 0.65; Grade 3: 0.62; Grade 4: 0.59; p trend < 0.001). More numerous (p < 0.001) and larger (p < 0.001) collateral vessels were associated with greater mean SFA plaque area (p trend < 0.001). More numerous (p trend = 0.007) and larger (p trend = 0.017) collateral vessels were associated with a lower prevalence of asymptomatic PAD. In conclusion, among participants with PAD, larger and more numerous collaterals, measured by MRA, were associated with lower ABI values, greater plaque area in the SFA, and a lower prevalence of asymptomatic PAD. Further study is needed to determine the role of collateral vessels in maintaining functional performance in PAD.


Assuntos
Índice Tornozelo-Braço , Artéria Femoral/patologia , Doença Arterial Periférica/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Artéria Femoral/fisiopatologia , Humanos , Claudicação Intermitente/etiologia , Claudicação Intermitente/patologia , Perna (Membro)/irrigação sanguínea , Perna (Membro)/fisiopatologia , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/complicações , Doença Arterial Periférica/fisiopatologia , Placa Aterosclerótica/patologia , Índice de Gravidade de Doença
2.
AJR Am J Roentgenol ; 197(5): 1064-72, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22021497

RESUMO

OBJECTIVE: The purpose of this study was to investigate the utility of bolus-triggering data from pulmonary CT angiography for predicting the diagnosis of pulmonary hypertension (PH) and right ventricular dysfunction (RVD) and to test its performance against previously established CT signs of PH. MATERIALS AND METHODS: Automated bolus-triggering data from pulmonary CT angiograms of 101 patients were correlated with echocardiographic findings and a variety of CT-derived indexes of PH and RVD, including right and left ventricular minor axis diameter; pulmonary artery (PA), aortic, and superior vena caval diameters; right ventricular thickness; contrast reflux; and configuration of the interventricular septum. For bolus triggering, a region of interest was placed in the main PA. Time to threshold, defined as the time from the beginning of contrast injection to the time attenuation exceeded the threshold (100 HU), was measured. On the basis of results of two consecutive echocardiographic studies, subjects were divided into control and PH groups. The latter group was subdivided into PH without RVD and PH with RVD. Time to threshold values were compared between groups and correlated with standard CT-derived parameters. RESULTS: Significant differences between groups were found in time to threshold, PA and right ventricular diameters, and PA-to-aorta and right ventricular-to-left ventricular ratios. Time to threshold had an incremental pattern from the control group (6.6 ± 1.0 seconds) to PH without RVD (9.2 ± 2.4 seconds) and PH with RVD (12.1 ± 3.4 seconds) (p < 0.001). The optimal diagnostic performance of time to threshold for revealing the presence of PH and RVD was at cutoff values of 7.75 and 8.75 seconds, respectively. Time to threshold had a strong direct correlation with PA diameter. In multivariable analyses, time to threshold was identified as a significant predictor of PH and RVD. The specificity of time to threshold and PA diameter together was higher than that of PA diameter alone. CONCLUSION: Measurement of time to threshold of contrast enhancement derived from bolus-timing data at MDCT may be a useful adjunctive tool for diagnosing PH and consequent RVD.


Assuntos
Angiografia/métodos , Meios de Contraste , Hipertensão Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Idoso , Análise de Variância , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Fatores de Tempo
3.
Radiology ; 254(1): 98-108, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20019138

RESUMO

PURPOSE: To compare accelerated real-time two-dimensional (2D) and segmented three-dimensional (3D) cine steady-state free precession magnetic resonance (MR) imaging techniques by using a 32-channel coil with a conventional 2D cine imaging approach for imaging the heart and to evaluate any difference caused by free breathing and breath holding for real-time imaging. MATERIALS AND METHODS: In this institutional review board-approved HIPAA-compliant study, 10 healthy volunteers and 22 consecutive patients who were suspected of having or were known to have heart disease underwent cardiac MR imaging by using a 32-channel coil. A conventional multisection 2D real-time cine sequence was used as the reference standard, and three additional accelerated cine sequences were implemented. Volumetric parameters, including ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume(SV), and myocardial mass, were derived. Wall motion and image quality were assessed by two radiologists. In addition, image time was registered. An additional set of images was acquired by using real-time sequences with free breathing, and quantitative measurements were compared with measurements on images obtained with breath holding. For quantitative analysis, repeated-measures analysis of variance, paired t test, and Bland-Altman analysis were used; for qualitative analysis, nonparametric Wilcoxon signed-rank test was used. RESULTS: All volumetric measurements were significantly correlated with those of the standard sequence (r > 0.80, P < .01). No significant difference among protocols was observed in terms of mean levels for EF or ESV (P > .05). However, a significant difference was indicated for EDV and SV (P < .01).The accelerated protocols had significantly shorter image times (P < .001). Wall motion scores were concordant with the standard sequence in 43-44 (93%-96%) segments for the accelerated protocols, with a strong interreader agreement (intraclass correlation coefficient, > or =0.93). No significant difference was identified between real-time protocols with free breathing and those with breath holding for measurement of volumetric parameters. CONCLUSION: Accelerated real-time 2D and segmented 3D cine techniques are comparable to the standard clinical protocol in assessment of left ventricular global and regional parameters in substantially shorter image times.


Assuntos
Cardiopatias/diagnóstico , Aumento da Imagem/instrumentação , Imagem Cinética por Ressonância Magnética/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Estudos de Casos e Controles , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/instrumentação , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas
4.
Cardiovasc Intervent Radiol ; 39(12): 1765-1769, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27491405

RESUMO

PURPOSE: Transradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device. MATERIALS AND METHODS: A retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complications were recorded. RESULTS: Two diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15-20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded. CONCLUSIONS: Haemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.


Assuntos
Fístula Arteriovenosa/terapia , Hemostasia/fisiologia , Dispositivos de Compressão Pneumática Intermitente , Diálise Renal/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Fístula Arteriovenosa/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
5.
6.
Int J Cardiovasc Imaging ; 27(4): 527-37, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20499279

RESUMO

The purpose of this study was to compare a navigator gated free breathing 3D Phase Sensitive Inversion Recovery (PSIR) TurboFLASH to an established 2D PSIR TurboFLASH method for detecting myocardial late gadolinium hyperenhanced lesions caused by infiltrative and non-ischemic cardiomyopathy. Under an IRB approved protocol; patients with suspected non-ischemic infiltrative myocardial heart disease were examined on a 1.5T MR scanner for late enhancement after the administration of gadolinium using a segmented 2D PSIR TurboFLASH sequence followed by a navigator-gated 3D PSIR TurboFLASH sequence. Two independent readers analyzed image quality using a four point Likert scale for qualitative analysis (0 = poor, non diagnostic; 1 = fair, diagnostic may be impaired; 2 = good, some artifacts but not interfering in diagnostics, 3 = excellent, no artifacts) and also reported presence or absence of scar. Detected scars were classified based on area and location and also compared quantitatively in volume. Twenty-seven patients were scanned using both protocols. Image quality score did not differ significantly (p = 0.358, Wilcoxon signed rank test) for both technique. Scars were detected in 24 patients. Larger numbers of hyperenhanced scars were detected with 3D PSIR (200) compared to 2D PSIR (167) and scar volume were significant larger in 3D PSIR (p = 0.004). The mean scar volume over all cases was 49.95 cm(3) for 2D PSIR and 70.02 cm(3) for 3D PSIR. The navigator gated free breathing 3D PSIR approach is a suitable method for detecting myocardial late gadolinium hyperenhanced lesions caused by non-ischemic cardiomyopathy due to its complete isotropic coverage of the left ventricle, improving detection of scar lesions compared to 2D PSIR imaging.


Assuntos
Cardiomiopatias/diagnóstico , Cicatriz/diagnóstico , Ventrículos do Coração/patologia , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Artefatos , Cardiomiopatias/patologia , Chicago , Cicatriz/patologia , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
J Cardiovasc Med (Hagerstown) ; 12(7): 460-8, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21610507

RESUMO

AIMS: In patients undergoing orthotopic liver transplantation (OLT), coronary artery disease (CAD), obstructive and nonobstructive, is associated with high morbidity and mortality. In OLT candidates, stress testing for detecting ischemia is often inaccurate, and this patient population often has relative contraindications for cardiac catheterization. The objective of this study was to describe the methods, assess the feasibility and determine the extent and severity of CAD in OLT candidates without a prior history of CAD using coronary multidetector computer tomographic angiography (MDCTA). METHODS: Sixty-five OLT candidates without known CAD underwent coronary MDCTA with dual source cardiac computed tomography (Siemens Definition). Coronary arteries were divided into 17 segments based on American Heart Association guidelines and evaluated independently by two blinded reviewers. Image quality of coronary MDCTA was assessed on a four-point Likert scale (0 = poor, 1 = fair, 2 = good, and 3 = excellent). Atherosclerotic lesions were evaluated for severity [mild (0-50%), moderate (51-70%), and severe (71-100%)], morphology, extent, location and consistency. RESULTS: Image quality was graded as good or excellent in 73.8%. In this cohort of OLT candidates without known CAD, 9% had normal coronary arteries, 58% had mild CAD and 34% had moderate to severe CAD. Plaque severity and burden scores were high. CONCLUSION: The prevalence of asymptomatic CAD is high in OLT candidates. Coronary MDCTA is feasible in OLT candidates and appears to be a useful technique to diagnose occult CAD in this patient population.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença Hepática Terminal/cirurgia , Transplante de Fígado , Tomografia Computadorizada por Raios X , Adulto , Doenças Assintomáticas , Calcinose/diagnóstico por imagem , Chicago/epidemiologia , Doença da Artéria Coronariana/epidemiologia , Doença Hepática Terminal/epidemiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Placa Aterosclerótica/diagnóstico por imagem , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA