Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Card Surg ; 37(12): 4833-4840, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36403275

RESUMO

BACKGROUND AND AIM: Bioprosthetic surgical aortic valve replacement (SAVR) is increasingly adopted in younger patients. We aimed to analyze mid-term follow-up data after SAVR to assess the performance of the prosthesis. METHODS: Data were collected from a single-center series of 154 patients, who underwent SAVR with a bioprosthetic heart valve with the RESILIA tissue at our Heart Centre in Siegburg. All procedural and midterm patient outcomes were documented. RESULTS: Patients had a mean age of 56.8 ± 9.9 years, 35.7% were female, and the mean logistic European system for cardiac operative risk evaluation (EuroSCORE) was 3.4 ± 3.6%. Diabetes (12.3%), atrial fibrillation (10.4%), and chronic obstructive pulmonary disease (COPD) (5.8%) were common comorbidities. The mean surgery duration was 163.8 ± 73.4 min, with the 23 mm (34.4%) and 25 mm (33.8%) heart valves being most frequently implanted. At 3-year follow-up, mean pressure gradient was 13.9 ± 5.9 mmHg, peak gradient was 23.6 ± 7.7 mmHg, and effective orifice area (EOA) was 1.9 ± 0.4 cm². No patient died during the operation, 3 (2.1%) patients within 30 days, and 4 (2.7%) thereafter with an overall mortality of n = 7. Of the surviving patients, 97.8% were in New York Heart Association (NYHA) class I/II and none had structural valve deterioration (SVD). CONCLUSION: Results of our single-center study indicate favorable procedural outcomes. The safety outcomes confirm preliminary earlier results of this novel bioprosthesis but include more patients and a longer midterm follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
2.
JACC Cardiovasc Imaging ; 15(2): 212-220, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34656470

RESUMO

OBJECTIVES: The aim of this study was to explore the association between mechanical dyssynchrony of the left ventricle before cardiac resynchronization therapy (CRT) and improvement of mitral regurgitation (MR) after CRT. BACKGROUND: MR is very frequent among patients with dilated cardiomyopathy and conduction delay. METHODS: Echocardiograms (pre-CRT and 12 ± 3.8 months thereafter) of 314 patients with dilated cardiomyopathy and any degree of MR, who underwent CRT device implantation according to guidelines, were analyzed. Left ventricular (LV) mechanical dyssynchrony was assessed by apical rocking (ApRock) and septal flash (SF), while MR severity was graded from I to IV on the basis of vena contracta width, regurgitation jet size, and proximal isovelocity surface area. RESULTS: At baseline, 30% of patients presented with severe MR (grade III or IV). In 62% of patients, MR decreased after CRT, and these patients more frequently had left bundle branch block, had more severe MR, had more dilated left ventricles, had lower ejection fractions, and more often had ApRock and SF. Reverse remodeling was more frequent among patients with MR reduction (ΔLV end-systolic volume -35.5% ± 27.2% vs -4.1% ± 33.2%; P < 0.001). In a multivariable logistic stepwise regression, only ApRock (odds ratio [OR]: 3.8; 95% CI: 1.7-8.5; P = 0.001), SF (OR: 3.6; 95% CI: 1.6-7.9; P = 0.002), and baseline MR (OR: 1.4; 95% CI: 1.0-1.9; P = 0.046) remained significantly associated with MR reduction. CONCLUSIONS: ApRock, SF, and severity of MR at baseline are strongly associated with MR reduction after CRT, while LV reverse remodeling is its underlying mechanism. Therefore, in patients with heart failure with LV dyssynchrony on optimal medical treatment, CRT should be the primary treatment attempt for relevant MR.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/terapia , Valor Preditivo dos Testes , Resultado do Tratamento , Remodelação Ventricular
3.
PLoS One ; 17(10): e0276369, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36301863

RESUMO

OBJECTIVE: The aim of this study was to investigate the impact of left atrial diverticula (LADs), left sided septal pouches (LSSPs) and middle right pulmonary veins (MRPVs) on recurrent atrial fibrillation (rAF) in patients undergoing laser pulmonary vein isolation procedure (PVI). MATERIAL AND METHODS: This retrospective study enrolled 139 patients with pre-procedural multiple detector computed tomography (MDCT) imaging and 12 months follow-up examination. LADs, LSSPs and MRPV were identified by two radiologists on a dedicated workstation using multiplanar reconstructions and volume rendering technique. Univariate and bivariate regression analyses with patient demographics and cardiovascular risk factors as covariates were performed to reveal independent factors associated with rAF. RESULTS: LADs were recorded in 41 patients (29%), LSSPs in 20 (14%) and MRPVs in 15 (11%). The right anterosuperior wall of the left atrium was the most prevalent location of LADs (68%). rAF occured in 20 patients, thereof, 15 exhibited an outpouching structure of the left atrium (LAD: 9, LSSP: 2 and MRPV: 3). Presence of an LAD (HR: 2.7, 95%CI: 1.0-8.4, p = 0.04) and permanent AF (HR: 4.8, 95%CI: 1.5-16.3, p = 0.01) were independently associated with rAF. CONCLUSIONS: LAD, LSSP and MRPV were common findings on pre-procedural cardiac computed tomography. LADs were revealed as potential independent risk factor of rAF, which might be considered for treatment planning and post-treatment observation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Divertículo , Veias Pulmonares , Humanos , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Recidiva , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia
4.
Circ Cardiovasc Imaging ; 15(11): e014296, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36330792

RESUMO

BACKGROUND: Septal strain patterns measured by echocardiography reflect the severity of left bundle branch block (LBBB)-induced left ventricular (LV) dysfunction. We investigated whether these LBBB strain stages predicted the response to cardiac resynchronization therapy in an observational study and developed a sheep model of LBBB-induced cardiomyopathy. METHODS: The clinical study enrolled cardiac resynchronization therapy patients who underwent echocardiographic examination with speckle-tracking strain analysis before cardiac resynchronization therapy implant. In an experimental sheep model with pacing-induced dyssynchrony, LV remodeling and strain were assessed at baseline, at 8 and 16 weeks. Septal strain curves were classified into 5 patterns (LBBB-0 to LBBB-4). RESULTS: The clinical study involved 250 patients (age 65 [58; 72] years; 79% men; 89% LBBB) with a median LV ejection fraction of 25 [21; 30]%. Across the stages, cardiac resynchronization therapy resulted in a gradual volumetric response, ranging from no response in LBBB-0 patients (ΔLV end-systolic volume 0 [-12; 15]%) to super-response in LBBB-4 patients (ΔLV end-systolic volume -44 [-64; -18]%) (P<0.001). LBBB-0 patients had a less favorable long-term outcome compared with those in stage LBBB≥1 (log-rank P=0.003). In 13 sheep, acute right ventricular pacing resulted in LBBB-1 (23%) and LBBB-2 (77%) patterns. Over the course of 8-16 weeks, continued pacing resulted in progressive LBBB-induced dysfunction, coincident with a transition to advanced strain patterns (92% LBBB-2 and 8% LBBB-3 at week 8; 75% LBBB-3 and 25% LBBB-4 at week 16) (P=0.023). CONCLUSIONS: The strain-based LBBB classification reflects a pathophysiological continuum of LBBB-induced remodeling over time and is associated with the extent of reverse remodeling in observational cardiac resynchronization therapy-eligible patients.


Assuntos
Bloqueio de Ramo , Terapia de Ressincronização Cardíaca , Ovinos , Animais , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Bloqueio de Ramo/diagnóstico , Remodelação Ventricular , Eletrocardiografia , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Resultado do Tratamento
5.
Clin Res Cardiol ; 109(3): 271-288, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31482241

RESUMO

According to recent recommendations on echocardiographic assessment of aortic valve stenosis direct measurement of transvalvular peak jet velocity, calculation of transvalvular mean gradient from the velocities using the Bernoulli equation and calculation of the effective aortic valve area by continuity equation are the appropriate primary key instruments for grading severity of aortic valve stenosis. It is obvious that no gold standard can be declared for grading the severity of aortic stenosis. Thus, conclusions of the exclusive evaluation of aortic stenosis by Doppler echocardiography seem to be questionable due to the susceptibility to errors caused by methodological limitations, mathematical simplifications and inappropriate documentation. The present paper will address practical issues of echocardiographic documentation to satisfy the needs to analyze different scenarios of aortic stenosis due to various flow conditions and pressure gradients. Transesophageal and multidimensional echocardiography should be implemented for reliable measurement of geometric aortic valve area and of cardiac dimensions at an early stage of the diagnostic procedure to avoid misinterpretation due to inconsistent results.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Erros Médicos/prevenção & controle , Estenose da Valva Aórtica/fisiopatologia , Documentação , Ecocardiografia Doppler/métodos , Humanos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
6.
Int J Cardiovasc Imaging ; 36(8): 1507-1514, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32356183

RESUMO

Setting up a randomized trial to assess the association of mechanical dyssynchrony (MD) and the success of cardiac resynchronization therapy (CRT) in heart failure with a wide QRS complex is ethically challenging. We therefore investigated this association in a retrospective cohort study observing different treatment strategies which were chosen based on the availability of health care resources. The survival of 500 patients from six Western European centers treated with CRT was compared to their 137 Eastern European counterparts not treated with CRT, with regard to the presence of MD. MD was visually assessed and was defined as the presence of apical rocking and/or septal flash. Patients were followed for a mean of 26 ± 8 months for the occurrence of death of any cause. As compared with medical therapy alone, CRT was associated with a more favorable survival (hazard ratio (HR), 0.53; 95% confidence interval (CI) 0.35-0.79; P = 0.002). Patients with MD treated by CRT had better survival than patients belonging to all other groups-they showed 72%, 66% and 56% reduction in all-cause mortality, respectively, compared to patients with MD not treated by CRT (HR 0.28; 95% CI 0.17-0.44), patients without MD treated by CRT (HR 0.34; 95% CI 0.22-0.52) and patients without MD not treated by CRT (HR 0.44; 95% CI 0.25-0.76). Patients with wide QRS complex who are treated with CRT have a significantly better survival when MD is present.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Fármacos Cardiovasculares/uso terapêutico , Ecocardiografia , Europa (Continente) , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
7.
Eur Heart J Cardiovasc Imaging ; 21(6): 619-628, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32031587

RESUMO

AIMS: Investigating the acute impact of cardiac resynchronization therapy (CRT) on regional myocardial work distribution in the left ventricle (LV) and to which extent it is related to long-term reverse remodelling. METHODS AND RESULTS: One hundred and thirty heart failure patients, referred for CRT implantation, were recruited in our prospective multicentre study. Regional myocardial work was calculated from non-invasive segmental stress-strain loop area before and immediately after CRT. The magnitude of volumetric reverse remodelling was determined from the change in LV end-systolic volume, 11 ± 2 months after implantation. CRT caused acute redistribution of myocardial work across the LV, with an increase in septal work, and decrease in LV lateral wall work (all P < 0.05). Amongst all LV walls, the acute change in work in the septum and lateral wall of the four-chamber view correlated best and significantly with volumetric reverse remodelling (r = 0.62, P < 0.0001), with largest change seen in patients with most volumetric reverse remodelling. In multivariate linear regression analysis, including conventional parameters, such as pre-implant QRS morphology and duration, LV ejection fraction, ischaemic origin of cardiomyopathy, and the redistribution of work across the septal and lateral walls, the latter appeared as the strongest determinant of volumetric reverse remodelling after CRT (model R2 = 0.414, P < 0.0001). CONCLUSION: The acute redistribution of regional myocardial work between the septal and lateral wall of the LV is an important determinant of reverse remodelling after CRT implantation. Our data suggest that the treatment of the loading imbalance should, therefore, be the main aim of CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Remodelação Ventricular
8.
JACC Cardiovasc Imaging ; 12(11 Pt 1): 2225-2244, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30878428

RESUMO

Reconstructive surgery of the aortic valve is being increasingly used in patients with aortic regurgitation and/or aortic aneurysm. Its success depends on restoring normal aortic valve and root form. Echocardiography is the most reliable and precise imaging technique because it defines abnormal morphology and function, essential for selecting appropriate substrates and guiding the surgical strategy. Despite technical advances in echocardiography, aortic valve and aortic root morphology and function are still assessed mainly using 2-dimensional echocardiography in clinical practice. This review focuses on the need to use 3-dimensional echocardiography to characterize different forms of aortic valve and root abnormalities and attempts to define echocardiographic predictors of successful valve-root complex repair.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional , Aneurisma Aórtico/fisiopatologia , Aneurisma Aórtico/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos , Hemodinâmica , Humanos , Valor Preditivo dos Testes , Procedimentos de Cirurgia Plástica , Recuperação de Função Fisiológica , Resultado do Tratamento
9.
Int J Cardiovasc Imaging ; 35(5): 881-895, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30701439

RESUMO

The assessment of aortic valve (AV) morphology is paramount for planning transcatheter AV implantation (TAVI). Nowadays, pre-TAVI sizing is routinely performed at one cardiac phase only, usually at mid-systole. Nonetheless, the AV is a dynamic structure that undergoes changes in size and shape throughout the cardiac cycle, which may be relevant for prosthesis selection. Thus, the aim of this study was to present and evaluate a novel software tool enabling the automatic sizing of the AV dynamically in three-dimensional (3D) transesophageal echocardiography (TEE) images. Forty-two patients who underwent preoperative 3D-TEE images were retrospectively analyzed using the software. Dynamic measurements were automatically extracted at four levels, including the aortic annulus. These measures were used to assess the software's ability to accurately and reproducibly quantify the conformational changes of the aortic root and were validated against automated sizing measurements independently extracted at distinct time points. The software extracted physiological dynamic measurements in less than 2 min, that were shown to be accurate (error 2.2 ± 26.3 mm2 and 0.0 ± 2.53 mm for annular area and perimeter, respectively) and highly reproducible (0.85 ± 6.18 and 0.65 ± 7.90 mm2 of intra- and interobserver variability, respectively, in annular area). Using the maximum or minimum measured values rather than mid-systolic ones for device sizing resulted in a potential change of recommended size in 7% and 60% of the cases, respectively. The presented software tool allows a fast, automatic and reproducible dynamic assessment of the AV morphology from 3D-TEE images, with the extracted measures influencing the device selection depending on the cardiac moment used to perform its sizing. This novel tool may thus ease and potentially increase the observer's confidence during prosthesis' size selection at the preoperative TAVI planning.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Hemodinâmica , Interpretação de Imagem Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Automação , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Design de Software , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação
10.
PLoS One ; 14(3): e0213261, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30856204

RESUMO

BACKGROUND: Psychological distress is common in patients with cardiovascular disease and negatively impacts outcome. HYPOTHESIS: Psychological distress is high in acute high risk cardiac patients eligible for a WCD, and associated with low quality of life. Distress is aggravated by WCD. METHODS: Consecutive patients eligible for a WCD were included in the prospective, multicenter "Cologne Registry of External Defibrillator" registry. Quality of life (Short Form-12), depressive symptoms (Beck-Depression Inventory II) and anxiety (State Trait Anxiety Inventory) were assessed at enrollment and 6-weeks, and associations with WCD prescription were analyzed. RESULTS: 123 patients (mean [SD] age 59 [± 14] years, 75% male) were included, 85 (69%) of whom received a WCD. At enrollment 21% showed clinically significant depressive symptoms and 52% anxiety symptoms, respectively. At 6 weeks, depressive and anxious symptoms significantly decreased to 7% and 25%, respectively. Depressive symptoms at enrollment and changes at 6 weeks showed significant associations with health-related quality of life, whereas anxious symptoms did not. There was a trend for better improvement of depression scores in patients with WCD (mean [SD] change in score points: -4.1 [6.1] vs -1.8 [3.9]; p = 0.09), whereas change of the anxiousness score was not different (-4.6 [9.5]) vs -3.7 [9.1], p = 0.68). CONCLUSION: In patients eligible for a WCD, depressive and anxiety symptoms were initially common and depressive symptoms showed a strong association with reduced health-related quality of life contributing to their clinical relevance. WCD recipients showed at least similar improvement of depression and anxiety at 6 weeks when compared to non recipients.


Assuntos
Transtornos de Ansiedade/diagnóstico , Desfibriladores Implantáveis , Transtorno Depressivo/diagnóstico , Cardiopatias/psicologia , Qualidade de Vida , Adulto , Idoso , Transtornos de Ansiedade/complicações , Transtorno Depressivo/complicações , Feminino , Cardiopatias/complicações , Cardiopatias/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Risco , Dispositivos Eletrônicos Vestíveis
11.
Eur Heart J Cardiovasc Imaging ; 20(1): 66-74, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29481687

RESUMO

Aim: To determine if incorporation of assessment of mechanical dyssynchrony could improve the prognostic value of patient selection based on current guidelines. Methods and results: Echocardiography was performed in 1060 patients before and 12 ± 6 months after cardiac resynchronization therapy (CRT) implantation. Mechanical dyssynchrony, defined as the presence of apical rocking or septal flash was visually assessed at the baseline examination. Response was defined as ≥15% reduction in left ventricular end-systolic volume at follow-up. Patients were followed for a median of 59 months (interquartile range 37-86 months) for the occurrence of death of any cause. Applying the latest European guidelines retrospectively, 63.4% of the patients had been implanted with a Class I recommendation, 18.2% with Class IIa, 9.4% with Class IIb, and in 9% no clear therapy recommendation was present. Response rates were 65% in Class I, 50% in IIa, 38% in IIb patients, and 40% in patients without a clear guideline-based recommendation. Assessment of mechanical dyssynchrony improved response rates to 77% in Class I, 75% in IIa, 62% in IIb, and 69% in patients without a guideline-based recommendation. Non-significant difference in survival among guideline recommendation classes was found (Log-rank P = 0.2). Presence of mechanical dyssynchrony predicted long-term outcome better than guideline Classes I, IIa, IIb (Log-rank P < 0.0001, 0.006, 0.004, respectively) and in patients with no guideline recommendation (P = 0.02). Comparable results were observed using the latest American Guidelines. Conclusion: Our data suggest that current guideline criteria for CRT candidate selection could be improved by incorporating assessment of mechanical asynchrony.


Assuntos
Terapia de Ressincronização Cardíaca , Fidelidade a Diretrizes , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Seleção de Pacientes , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento
12.
Eur Heart J Cardiovasc Imaging ; 20(5): 504-511, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30649246

RESUMO

AIMS: Observation of better outcome in women after cardiac resynchronization therapy (CRT) has led to controversies about a potential sex-specific response. In this study, we investigated to which extent this sex-specific difference in CRT outcome could be explained by differences in baseline characteristics between both sexes. METHODS AND RESULTS: We retrospectively analysed data from a multicentre registry of 1058 patients who received CRT. Patients were examined by echocardiography before and 12 ± 6 months after implantation. Response was defined as ≥15% reduction of left ventricular end-systolic volume at follow-up. Patient's characteristics at baseline, including New York Heart Association class, ejection fraction, QRS width and morphology, ischaemic aetiology of cardiomyopathy (ICM), number of scarred segments, age at implantation, atrial fibrillation, and mechanical dyssynchrony (Dyss) were analysed. Patients were followed for a median duration of 59 months. Primary end point was all-cause mortality. Women (24% of the population) had less ICM (23% vs. 49%, P < 0.0001), less scarred segments (0.4 ± 1.3 vs. 1.0 ± 2.1, P < 0.0001), more left bundle branch block (LBBB; 87% vs. 80%, P = 0.01), and more Dyss at baseline (78% vs. 57%, P < 0.0001). Without matching baseline differences, women showed better survival (log rank P < 0.0001). After matching, survival was similar (log rank P = 0.58). In multivariable analysis, female sex was no independent predictor of neither volumetric response (P = 0.06) nor survival (P = 0.31). CONCLUSION: Our data suggest that the repeatedly observed better outcome in women after CRT is mainly due to the lower rate ICM and smaller scars. When comparing patients with similar baseline characteristics, the response of both sexes to CRT is similar.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia Doppler , Avaliação de Resultados em Cuidados de Saúde , Idoso , Causas de Morte , Angiografia Coronária , Eletrocardiografia , Feminino , Testes de Função Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores Sexuais
13.
Circulation ; 116(11 Suppl): I240-5, 2007 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-17846311

RESUMO

BACKGROUND: To evaluate initial multicenter results with minimally invasive transapical aortic valve implantation (TAP-AVI) for high risk patients with aortic stenosis. METHODS AND RESULTS: TAP-AVI was performed via a small anterolateral minithoracotomy with or without femoro-femoral extracorporeal circulation (ECC) on the beating heart. A pericardial xenograft fixed within a stainless steel, balloon expandable stent (Edwards SAPIEN THV, Edwards Lifesciences) was used. Fifty-nine consecutive patients (81+/-6 years, 44 female) were operated on from 02/06 until 10/06 at 4 centers using fluoroscopic and echocardiographic visualization. Average EuroSCORE predicted risk for mortality was 27+/-14%. TAP valve positioning was performed successfully in 53 patients, 4 required early conversion to sternotomy. Implantation (23-mm valves in 19 and 26-mm valves in 40 patients) was performed on the beating heart during brief periods of rapid ventricular pacing. Thirty-one patients were operated on without cardiopulmonary bypass. Neither coronary artery obstruction nor migration of the prosthesis was observed, and all valves had good hemodynamic function. Echocardiography revealed minor paravalvular leakage in 26 patients (trace in 11, mild in 12, and severe in 3). Eight patients died in-hospital (13.6%) without any valve dysfunction. Actuarial survival was 75.7+/-5.9% at a follow-up interval of 110+/-77 days (range 1 to 255 days). CONCLUSIONS: TAP-AVI can be performed safely with good early results in high risk patients. Long-term valve performance as well as broader based applications of this promising approach will need to be studied.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Animais , Valva Aórtica/patologia , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Bovinos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Masculino , Desenho de Prótese/instrumentação , Desenho de Prótese/métodos , Desenho de Prótese/tendências
14.
Eur Heart J Cardiovasc Imaging ; 19(8): 941-949, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29272366

RESUMO

Aims: The interaction between asynchronous regional myocardial activation and left ventricular (LV) wall remodelling has not been well established. We investigated the relationship between time of onset of longitudinal shortening (Tonset), regional myocardial work, and segmental LV wall thickness (SWT) in patients treated with cardiac resynchronization therapy (CRT). Methods and results: We analysed 26 patients with sinus rhythm, non-ischaemic cardiomyopathy (63 ± 9 years, 69% male, QRS duration 174 ± 18 ms) and positive response to CRT (15% reduction in end-systolic volume). Longitudinal strain was obtained by 2D speckle-tracking echocardiography before and after [14.5 (7-29) months] CRT. Tonset and SWT were measured in 18 segments per LV. Segmental myocardial work was calculated from non-invasive segmental stress-strain loop area. Before CRT, Tonset was the shortest in septal and anteroseptal and the longest in lateral and posterior walls (P < 0.001) and not different after CRT (P = 0.733). Before CRT, septal and anteroseptal walls were significantly thinner than lateral and posterior. After CRT, reverse remodelling increased thickness in septal and anteroseptal and thinned lateral and posterior segments (P < 0.001). Before CRT, non-uniformity in work distribution with reduced work in septal and anteroseptal and increased work in lateral and posterior walls (P < 0.001) was observed. After CRT, distribution of myocardial work was uniform (P = 0.215). Conclusion: Dys-synchronous myocardial shortening is related to thinning of early and thickening of late activated segments in heart failure with conduction delay. Correction of dys-synchrony leads to regression of inhomogeneity towards more evenly distributed wall thickness. Regional differences in myocardial work load that are homogenized by successful CRT are considered as the underlying pathophysiological mechanism.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Disfunção Ventricular Esquerda/diagnóstico por imagem , Remodelação Ventricular/fisiologia , Idoso , Análise de Variância , Estudos de Coortes , Bases de Dados Factuais , Eletrocardiografia/métodos , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Prognóstico , Volume Sistólico/fisiologia , Fatores de Tempo , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/terapia
15.
J Am Soc Echocardiogr ; 31(4): 515-525.e5, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29625649

RESUMO

BACKGROUND: Accurate aortic annulus (AoA) sizing is crucial for transcatheter aortic valve implantation planning. Three-dimensional (3D) transesophageal echocardiography (TEE) is a viable alternative to the standard multidetector row computed tomography (MDCT) for such assessment, with few automatic software solutions available. The aim of this study was to present and evaluate a novel software tool for automatic AoA sizing by 3D TEE. METHODS: One hundred one patients who underwent both preoperative MDCT and 3D TEE were retrospectively analyzed using the software. The automatic software measurements' accuracy was compared against values obtained using standard manual MDCT, as well as against those obtained using manual 3D TEE, and intraobserver, interobserver, and test-retest reproducibility was assessed. Because the software can be used as a fully automatic or as an interactive tool, both options were addressed and contrasted. The impact of these measures on the recommended prosthesis size was then evaluated to assess if the software's automated sizes were concordant with those obtained using an MDCT- or a TEE-based manual sizing strategy. RESULTS: The software showed very good agreement with manual values obtained using MDCT and 3D TEE, with the interactive approach having slightly narrower limits of agreement. The latter also had excellent intra- and interobserver variability. Both fully automatic and interactive analyses showed excellent test-retest reproducibility, with the first having a faster analysis time. Finally, either approach led to good sizing agreement against the true implanted sizes (>77%) and against MDCT-based sizes (>88%). CONCLUSIONS: Given the automated, reproducible, and fast nature of its analyses, the novel software tool presented here may potentially facilitate and thus increase the use of 3D TEE for preoperative transcatheter aortic valve implantation sizing.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Tomografia Computadorizada Multidetectores/métodos , Software , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
17.
Heart Surg Forum ; 10(2): E105-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17597030

RESUMO

Tissue ingrowth of a prosthetic heart valve usually leads to a stenosis. We report a rare case of a patient with a fixation of the prosthetic leaflet due to tissue ingrowth. This state caused a total prosthetic insufficiency. The therapy used to treat this prosthetic heart valve with tissue ingrowth is discussed in this report.


Assuntos
Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese , Valva Aórtica/cirurgia , Remoção de Dispositivo , Feminino , Seguimentos , Tecido de Granulação/crescimento & desenvolvimento , Tecido de Granulação/patologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pessoa de Meia-Idade , Reoperação , Medição de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Eur Heart J Cardiovasc Imaging ; 18(10): 1109-1117, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28950379

RESUMO

AIMS: Clinical experience indicates that limited or no reverse left ventricular (LV) remodelling may not necessarily imply non-response to cardiac resynchronization therapy (CRT). We investigated the association of the extent of LV remodelling, mechanical dyssynchrony, and survival in patients undergoing CRT. METHODS AND RESULTS: In 356 CRT candidates, three blinded readers visually assessed the presence of mechanical dyssynchrony (either apical rocking and/or septal flash) before device implantation and also its correction by CRT 12 ± 3 months post-implantation. To assess LV reverse remodelling, end-systolic volumes (ESV) were measured at the same time points. Patients were divided into four subgroups: no LV remodelling (ESV change 0 ± 5%), mild LV reverse remodelling (ESV reduction 5-15%), significant LV reverse remodelling (ESV reduction ≥15%), and LV volume expansion (ESV increase ≥5%). Patients were followed for all-cause mortality during the median follow-up of 36 months. Patients with LV remodelling as in the above defined groups showed 58, 54, and 84% reduction in all-cause mortality compared to patients with volume expansion. In multivariable analysis, LVESV change remained independently associated with survival, with an 8% reduction in mortality for every 10% decrease in LVESV (P = 0.0039), but an optimal cut-off point could not be established. In comparison, patients with corrected mechanical dyssynchrony showed 71% reduction in all-cause mortality (P < 0.001). CONCLUSION: Volumetric response assessed at 1-year after CRT is strongly associated with long-term mortality. However, an optimal cut-off cannot be established. The association of the correction of mechanical dyssynchrony with survival was stronger than that of any volumetric cut-off.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Causas de Morte , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/terapia , Idoso , Análise de Variância , Estudos de Coortes , Ecocardiografia/métodos , Europa (Continente) , Feminino , Hemodinâmica/fisiologia , Humanos , Internacionalidade , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Remodelação Ventricular/fisiologia
19.
JACC Cardiovasc Imaging ; 10(10 Pt A): 1091-1099, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28017393

RESUMO

OBJECTIVES: The aim of this study was to compare the volumetric response and the long-term survival after cardiac resynchronization therapy (CRT) in patients with intrinsic left bundle branch block (LBBB) versus chronic right ventricular pacing (RVP) with respect to the presence of mechanical dyssynchrony (MD). BACKGROUND: Chronic RVP induces an iatrogenic LBBB and asynchronous left ventricular contraction that is potentially reversible by upgrading to CRT. METHODS: A total of 914 patients eligible for CRT (117 with conventional pacemakers and 797 with intrinsic LBBB) were included in the study. MD was visually assessed before CRT and was defined as the presence of either apical rocking and/or septal flash on baseline echocardiograms. Patients with a left ventricular end-systolic volume decrease of ≥15% during the follow-up were considered responders. Patients were followed for all-cause mortality during the median follow-up of 48 months (interquartile range: 29 to 66 months). RESULTS: MD was observed in 51% of patients with RVP versus 77% in patients with intrinsic LBBB (p < 0.001). Patients with RVP and MD had a similar likelihood of volumetric response as did patients with intrinsic LBBB and MD (adjusted odds ratio: 0.71; 95% confidence interval: 0.33 to 1.53; p = 0.385). There was no significant difference in long-term survival between patients with RVP and intrinsic LBBB (adjusted hazard ratio: 1.101; 95% confidence interval: 0.658 to 1.842; p = 0.714). Patients with visual MD and either intrinsic LBBB or RVP had a more favorable survival than those without MD (p < 0.001). CONCLUSIONS: The likelihood of volumetric response and a favorable long-term survival of patients with RVP was similar to those of patients with intrinsic LBBB and were mainly determined by the presence of MD and not by the nature of LBBB.


Assuntos
Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca , Contração Miocárdica , Função Ventricular Esquerda , Função Ventricular Direita , Idoso , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Ecocardiografia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
20.
PLoS One ; 11(6): e0156769, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27258655

RESUMO

AIMS: The impact of type of first medical contact (FMC) in the setting of a guideline conform metropolitan ST-elevation myocardial infarction (STEMI) network providing obligatory primary percutaneous coronary intervention (PCI) is unclear. METHODS AND RESULTS: 3,312 patients were prospectively included between 2006 and 2012 into a registry accompanying the "Cologne Infarction Model" STEMI network, with 68.4% primarily presenting to emergency medical service (EMS), 17.6% to non-PCI-capable hospitals, and 14.0% to PCI-capable hospitals. Median contact-to-balloon time differed significantly by FMC with 89 minutes (IQR 72-115) for EMS, 107 minutes (IQR 85-148) for non-PCI- and 65 minutes (IQR 48-91) for PCI-capable hospitals (p < 0.001). TIMI-flow grade III and in-hospital mortality were 75.7% and 10.4% in EMS, 70.3% and 8.6% in non-PCI capable hospital and 84.4% and 5.6% in PCI-capable hospital presenters, respectively (p both < 0.01). The association of FMC with in-hospital mortality was not significant after adjustment for baseline characteristics, but risk of TIMI-flow grade < III remained significantly increased in patients presenting to non-PCI capable hospitals. CONCLUSION: Despite differences in treatment delay by type of FMC in-hospital mortality did not differ significantly. The increased risk of TIMI-flow grade < III in patients presenting to non PCI-capable hospitals needs further study.


Assuntos
Modelos Teóricos , Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Angiografia Coronária , Eletrocardiografia , Feminino , Frequência Cardíaca/fisiologia , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA