Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(19)2022 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-36236571

RESUMO

In this study, a piezoelectric micromachined ultrasonic transducer (PMUT) is integrated with a microliter-sized volume-tunable Helmholtz resonator. The passive Helmholtz resonator is constructed using an SU8 photolithography-defined square opening plate as the neck portion, a 3D-printed hollow structure with a threaded insert nut, and a precision set screw to form the volume-controllable cavity of the Helmholtz resonator. The fabricated piezoelectric films acted as ultrasonic actuators attached to the surface of the neck SU8 plate. Experimental results show that the sound pressure level (SPL) and operation bandwidth could be effectively tuned, and a 200% SPL increase and twofold bandwidth enhancement are achieved when setting the cavity length to 0.75 mm compared with the open-cavity case. A modified Helmholtz resonator model is proposed to explain the experimental results. The adjusting factors of the effective mass and viscous damper are created to modify the existing parameters in the conventional Helmholtz resonator model. The relationship between the adjusting factors and cavity length can be described well using a two-term power series curve. This modified Helmholtz resonator model not only provides insight into this active-type Helmholtz resonator operation but also provides a useful estimation for its optimal design and fabrication.


Assuntos
Transdutores , Ultrassom , Desenho de Equipamento , Pressão
2.
Appl Opt ; 58(4): 1073-1083, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30874157

RESUMO

In the automatic detection for surface defects of optical components, the digs and dust particles exhibit similar features: point-like shape and variable intensity reflectivity. On this condition, these two types with entirely different damages are easily confused so that misjudgments will be induced. To solve this problem, a polarization-characteristics-based classification method of digs and dust particles (PCCDD) is proposed based on the polarimetric imaging technique and dark-field imaging technique. First, a dark-field imaging system equipped with a polarization state generator (PSG) and a polarization state analyzer (PSA) is employed to measure and establish normalized Mueller matrices' datasets of digs and dust particles. And by a nonlinear global search combined with a separability evaluation method, the optimal number of acquisitions and corresponding polarization measurement states of the PSG and the PSA are obtained, as well as the parameters of classification function. Then, multiple polarization images are acquired under the optimal states to extract a multidimensional feature description that relates only to the polarization characteristics of the defect; this subsequently acts as the input vector of the classifier to finally achieve the classification. This method takes full advantage of both the difference in polarization properties between digs and dust particles and the characteristic that the polarization properties of digs are relatively invariant while those of dust particles have a large variability. The classification process involves only simple matrix operations. Compared to the traditional discrimination method based on intensity images, the features obtained by this method have a higher separability. Experiments show that the classification accuracy reaches over 90%. This method can be further applied to the recognition and discrimination of other defects in the field of surface defects' detection.

3.
Sensors (Basel) ; 19(18)2019 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-31487858

RESUMO

This paper presents a soft engine which performs up-and-down motion with four planar film-structured ionic polymer-metal composites (IPMC) actuators. This soft engine assembled with a stretchable Fresnel zone plate is capable of tuning the focus of ultrasonic beam. Instead of conventional clamps, we employ 3D printed frame pairs with magnets and a conductive gold cloth to provide an alternative solution for securing the IPMC actuators during assembly. The design and analysis of the zone plate are carefully performed. The zone plate allows the plane ultrasonic wave to be effectively focused. The motion of IPMC actuators stretch the metal-foil-made zone plate to tune the focal range of the ultrasonic beam. The zone plate, 3D frames and IPMC actuators were fabricated, assembled and tested. The stiffness normal to the stretchable zone plate with varied designs was investigated and the seven-zone design was selected for our experimental study. The force responsible for clamping the IPMC actuators, controlled by the magnetic attraction between the fabricated frames, was also examined. The driving voltage, current and resulting displacement of IPMC actuation were characterized. The developed soft engine stretching the zone plate to tune the focal point of the ultrasonic beam up to 10% was successfully demonstrated.

4.
Sensors (Basel) ; 19(21)2019 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-31671739

RESUMO

This study proposes a novel piezoelectric micromachined ultrasonic transducer (PMUT), fabricated on a metal foil. Using a bottom-up, cost-effective micromachining technique, the PMUTs made of electrodes, a piezoelectric film, or electrode-sandwiched structures with versatile patterns were implemented on a large-area foil thinner rather than regular paper. The proposed microfabrication facilitated the PMUT to be able to generate ultrasonic waves with fundamental and harmonic resonances. The fourth-order resonances of the fabricated PMUT functionally operated at an ultrasonic spectrum of approximately 30 kHz as an ultrasonic emitter. The developed PMUT was paired with a microelectromechanical system (MEMS) microphone module for range-finding applications in the range of several tens of millimeters. A signal-processing scheme was developed to extract the representative pattern from the acquired signals that were emitted and received. The pattern enabled finding the distance between the PMUT and the microphone using time-of-flight and strength-variation technology. The developed PMUT-microphone pair demonstrated its range-finding performance, displaying an error of less than 0.7% using the time-of-flight method.

5.
Sensors (Basel) ; 16(4): 433, 2016 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-27023549

RESUMO

This paper presents an innovative tuning fork-shaped ionic polymer metal composite (IPMC) actuator. With an integrated soft strain gauge and water supply mechanism (WSM), the surface strain of the actuator can be sensed in situ, and providing a continuous water supply maintains the water content inside the IPMC for long-term operation in air. The actuator was fabricated using a micromachining technique and plated with a nickel electrode. The device performance was experimentally characterized and compared with an actuator without a WSM. A large displacement of 1.5 mm was achieved for a 6 mm-long prong with 7-V dc actuation applied for 30 s. The measured current was analyzed using an electrochemical model. The results revealed that the faradaic current plays a crucial role during operation, particularly after 10 s. The measured strain confirms both the bending and axial strain generation during the open-and-close motion of the actuator prongs. Most of the water loss during device operation was due to evaporation rather than hydrolysis. The constructed WSM effectively maintained the water content inside the IPMC for long-term continuous operation.

6.
Pharm Biol ; 54(9): 1680-6, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26916555

RESUMO

Context Mangiferin has been reported to possess a potential hypouricaemic effect. However, the pharmacokinetic studies in rats showed that its oral bioavailability was only 1.2%, suggesting that mangiferin metabolites might exert the action. Objective The hypouricaemic effect and the xanthine oxidase inhibition of mangiferin and norathyriol, a mangiferin metabolite, were investigated. Inhibition of norathyriol analogues (compounds 3-9) toward xanthine oxidase was also evaluated. Materials and methods For a dose-dependent study, mangiferin (1.5-6.0 mg/kg) and norathyriol (0.92-3.7 mg/kg) were administered intragastrically to mice twice daily for five times. For a time-course study, mice received mangiferin and norathyriol both at a single dose of 7.1 µmol/kg. In vitro, inhibition of test compounds (2.4-2.4 mM) against xanthine oxidase activity was evaluated by the spectrophotometrical method. The inhibition type was identified from Lineweaver-Burk plots. Results Norathyriol (0.92, 1.85 and 3.7 mg/kg) dose dependently decreased the serum urate levels by 27.0, 33.6 and 37.4%, respectively. The action was more potent than that of mangiferin at the low dose, but was equivalent at the higher doses. Additionally, the hypouricaemic action of them exhibited a time dependence. In vitro, norathyriol markedly inhibited the xanthine oxidase activities, with the IC50 value of 44.6 µM, but mangiferin did not. The kinetic studies showed that norathyriol was an uncompetitive inhibitor by Lineweaver-Burk plots. The structure-activity relationships exhibited that three hydroxyl groups in norathyriol at the C-1, C-3 and C-6 positions were essential for maintaining xanthine oxidase inhibition. Discussion and conclusion Norathyriol was responsible for the hypouricaemic effect of mangiferin via inhibiting xanthine oxidase activity.


Assuntos
Inibidores Enzimáticos/farmacologia , Supressores da Gota/farmacologia , Hiperuricemia/tratamento farmacológico , Ácido Úrico/sangue , Xantenos/farmacologia , Xantina Oxidase/antagonistas & inibidores , Xantonas/farmacologia , Administração Oral , Animais , Biomarcadores/sangue , Biotransformação , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Esquema de Medicação , Inibidores Enzimáticos/administração & dosagem , Inibidores Enzimáticos/metabolismo , Supressores da Gota/administração & dosagem , Supressores da Gota/metabolismo , Hiperuricemia/sangue , Hiperuricemia/induzido quimicamente , Hiperuricemia/enzimologia , Cinética , Camundongos , Estrutura Molecular , Ácido Oxônico , Relação Estrutura-Atividade , Xantenos/administração & dosagem , Xantenos/metabolismo , Xantina Oxidase/metabolismo , Xantonas/administração & dosagem , Xantonas/metabolismo
7.
Eur J Immunol ; 43(7): 1953-62, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23589118

RESUMO

Dysfunctional hepatitis C virus (HCV) specific CD4(+) T cells are known to contribute to inadequate adaptive immunity in chronic hepatitis C (CHC), although the underlying mechanisms remain largely undefined. In this study, OX40 ligand (OX40L) expression was investigated in 41 treatment-naïve CHC patients, 20 sustained virological responders and 36 healthy subjects. We observed that OX40L expression was significantly upregulated in peripheral monocytes in CHC patients compared with sustained virological responders and healthy subjects. OX40L upregulation correlated significantly with plasma viral load rather than serum alanine aminotransaminase levels. Furthermore, longitudinal analyses indicated that upregulated OX40L expression on monocytes is closely associated with rapid or early virological responses in patients receiving pegylated IFN-α/ribavirin treatment. In vitro, HCV core antigen strongly stimulated monocyte expression of OX40L and blockade of TLR2 signaling significantly downregulated OX40L expression. More importantly, elevated OX40L expression was also shown to be closely associated with elevation of the HCV-specific CD4(+) T-cell response and in vitro blockade of OX40L expressed on monocytes led to impaired CD4(+) T-cell function. These findings, therefore, implicate OX40L expression can be used as a marker to evaluate antiviral treatment efficacy and extend the notion that enhancement of OX40L expression could be a good way for immunotherapy in CHC patients.


Assuntos
Hepatite C Crônica/imunologia , Monócitos/imunologia , Ligante OX40/imunologia , Adulto , Biomarcadores/metabolismo , Feminino , Genótipo , Hepatite C Crônica/genética , Hepatite C Crônica/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Monócitos/metabolismo , Ligante OX40/genética , Ligante OX40/metabolismo , Regulação para Cima , Adulto Jovem
8.
Hepatol Res ; 44(10): E198-205, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23905760

RESUMO

AIM: Interleukin-21 (IL-21) is involved in effective primary hepatic immune response against hepatitis B virus (HBV) and profibrotic function. However, the role of IL-21 in HBV-associated liver cirrhosis is poorly understood. This study aimed to investigate the role of IL-21 in HBV-associated liver cirrhosis and possible mechanisms. METHODS: The study subjects included 10 healthy controls and 30 patients with HBV-associated liver cirrhosis that categorized into three subgroups based on Child-Pugh score (A, 13; B, 10; C, 7). The frequencies of IL-21(+) CD4(+) T cells were detected by flow cytometry, and the level of IL-21 in plasma was measured by enzyme-linked immunoassay. The distribution of IL-21(+) cells in situ in liver was observed by immunohistochemistry. In addition, the in vitro expression of α-smooth muscle actin (α-SMA), apoptosis and proliferation markers of LX-2 cells were examined by flow cytometry and Cell Counting Kit-8 kit. Finally, the collagen levels in the supernatant were measured by chemiluminescence. RESULTS: Increased peripheral number of IL-21(+) CD4(+) cells, elevated plasma level of IL-21 and IL-21(+) cell accumulation in liver were observed in patients with HBV-associated liver cirrhosis. In vitro administration of IL-21 was accompanied with increased expression of α-SMA, inhibited LX-2 cells apoptosis and upregulated collagen production by LX-2 cells. CONCLUSION: IL-21 may contribute to the fibrogenesis of HBV-associated liver cirrhosis by activating the hepatic stellate cells. Therefore, neutralization of IL-21 could be a favorable new therapeutic strategy for liver cirrhosis treatment.

9.
Exp Parasitol ; 140: 18-23, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24632190

RESUMO

Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of P. falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8-24 h followed by routine culture. When cultures with 27-60% of ring stage were synchronized using this procedure, 70-93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled.


Assuntos
Testes de Sensibilidade Parasitária/métodos , Plasmodium falciparum/crescimento & desenvolvimento , Refrigeração , Antimaláricos/farmacologia , Temperatura Baixa , Relação Dose-Resposta a Droga , Eritrócitos/parasitologia , Indicadores e Reagentes , Concentração Inibidora 50 , Plasmodium falciparum/efeitos dos fármacos , Sorbitol
10.
Sensors (Basel) ; 14(5): 8380-97, 2014 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-24824370

RESUMO

This paper presents a swirl-shaped microfeatured ionic polymer-metal composite (IPMC) actuator. A novel micromachining process was developed to fabricate an array of IPMC actuators on a glass substrate and to ensure that no shortcircuits occur between the electrodes of the actuator. We demonstrated a microfluidic scheme in which surface tension was used to construct swirl-shaped planar IPMC devices of microfeature size and investigated the flow velocity of Nafion solutions, which formed the backbone polymer of the actuator, within the microchannel. The unique fabrication process yielded top and bottom electrodes that exhibited asymmetric surface resistance. A tool for measuring surface resistance was developed and used to characterize the resistances of the electrodes for the fabricated IPMC device. The actuator, which featured asymmetric electrode resistance, caused a nonzero-bias current when the device was driven using a zero-bias square wave, and we propose a circuit model to describe this phenomenon. Moreover, we discovered and characterized a bending and rotating motion when the IPMC actuator was driven using a square wave. We observed a strain rate of 14.6% and a displacement of 700 µm in the direction perpendicular to the electrode surfaces during 4.5-V actuation.

11.
Zhonghua Yi Xue Za Zhi ; 94(20): 1559-62, 2014 May 27.
Artigo em Zh | MEDLINE | ID: mdl-25146744

RESUMO

OBJECTIVE: To explore the expression of CD160, a costimulator, on CD4(+) and CD8(+) T cells in chronic human immunodeficiency virus-1 (HIV-1) infected patients. METHODS: A total of 23 chronic HIV-1 infected patients were enrolled into 302 Hospital of People's Liberation Army from January 2010 to December 2011. Meanwhile, 20 healthy individuals were selected as healthy controls (HC). Peripheral blood was collected, peripheral blood mononuclear cells (PBMC) were isolated by density gradient centrifugation and CD160 was stained with fluorescent antibody. The expressions of CD160 on CD4(+) and CD8(+) T cell subsets were detected by flow cytometry and its correlation with CD4(+) T cell absolute number and HIV RNA viral load were analyzed. RESULTS: The expressions of CD160 on CD4(+) and CD8(+) T cell increased versus HC (on CD4(+) T cells, percentage: (14.3 ± 7.5)% vs (3.9 ± 2.2)%, median fluorescent intensity (MFI): 26.4 ± 11.0 vs 12.4 ± 2.9; on CD8(+) T cells, percentage: (40.9 ± 13.2)% vs (12.9 ± 6.6)%, MFI: 52.5 ± 17.4 vs 18.2 ± 5.0). Furthermore, the expression of CD160 on CD4(+) T cells was negatively correlated with CD4(+) T cell absolute number (r = -0.550, P = 0.010) and positively with HIV RNA load (r = 0.522, P = 0.015). However, the expression of CD160 on CD8(+) T cells was not correlated with CD4(+) T cell absolute number or HIV RNA load. The expressions of CD160 on CD8(+) T cell subsets Tn, Tcm and Tem in patients with chronic HIV-1 infection increased compared with HC (25.3 ± 17.6 vs 5.0 ± 3.1, 45.8 ± 13.0 vs 20.4 ± 4.3, 37.0 ± 13.6 vs 20.0 ± 10.8). In addition, Tn subset decreased while Tcm subset increased in CD160(+) CD8(+) T cell subset distribution in patients with HIV-1 infection compared with HC subjects. CONCLUSION: CD160 may contribute to the exhaustion of CD4(+) and CD8(+) T cells and influence the distribution of memory CD8(+) T cell subsets.


Assuntos
Antígenos CD/metabolismo , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD8-Positivos/imunologia , Infecções por HIV/imunologia , HIV-1 , Receptores Imunológicos/metabolismo , Adulto , Estudos de Casos e Controles , Doença Crônica , Progressão da Doença , Feminino , Proteínas Ligadas por GPI/metabolismo , Infecções por HIV/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
12.
Eur Geriatr Med ; 15(1): 3-18, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37870707

RESUMO

PURPOSE: Dementia and Alzheimer's disease (AD) pose significant challenges to public health globally with no effective treatment strategies available. Therefore, the research focuses on developing effective prophylaxis to prevent the onset of these diseases. Recent studies have suggested that low-dose aspirin may help reduce the risk of dementia. Nonetheless, evidence regarding the correlation between aspirin consumption and the onset of dementia and AD is limited. This review aims to provide an up-to-date summary of the existing evidence and evaluate the association between aspirin and the onset of dementia and Alzheimer's disease. METHODS: A systematic search of PubMed, Embase, Web of Science, PsycINFO, and CINAHL databases was conducted to find eligible studies published until April 2023. A random-effects meta-analysis of the eligible studies was then performed to assess the link between aspirin use and the onset of dementia and Alzheimer's disease. Additionally, we conducted subgroup analyses to evaluate the overall effect of low-dose (75-100 mg) aspirin consumption on the onset of dementia and AD. RESULTS: A total of 875 studies were identified, with only 22 meeting the inclusion criteria. There was no statistically significant impact of aspirin consumption on the onset of dementia (HR 1.13, 11 studies) or Alzheimer's disease (HR 0.91, 3 studies). Additionally, subgroup analysis showed that taking low doses of aspirin (75-100 mg) did not significantly affect the onset of either dementia (HR 0.96, 13 studies) or Alzheimer's disease (HR 0.85, 2 studies). CONCLUSIONS: Aspirin use does not decrease the risk of dementia or AD, even when taken in low doses. However, the quality of the studies analyzed was inadequate, with only three randomized controlled trials included in the review. Future high-quality studies are needed to assess the effect of aspirin consumption on these diseases. These findings may assist clinicians in selecting appropriate prophylactic strategies for patients at risk of developing dementia and AD.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/epidemiologia , Doença de Alzheimer/prevenção & controle , Doença de Alzheimer/tratamento farmacológico , Aspirina/uso terapêutico
13.
Sci Rep ; 14(1): 8843, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632292

RESUMO

The primary goal of this study is to develop a wearable system for providing CNC machine operators with visual and tactile perception of triaxial cutting forces, thereby assisting operators in industrial environments to enhance work efficiency and prevent mechanical failures. To achieve this goal, we successfully integrated a virtual machining tool simulator with the remote-control wearable system (RCWS). Using the 'King Path' milling parameters, we employed the simulation software developed by the AIM-HI team to calculate static and dynamic cutting forces, converting this data into vibrational commands for the RCWS to generate corresponding tactile feedback. Furthermore, we conducted extensive experiments, testing various data conversion methods, including three sampling techniques and two data compression strategies, aiming to provide accurate tactile feedback related to cutting forces under different operating conditions.

14.
Appl Opt ; 52(4): 829-37, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23385925

RESUMO

This paper proposes a tunable-focus liquid lens implemented with a simple cylindrical container structure and liquid as the lens material. The cylindrical container was constructed using a Pb [Zr(0.52)Ti(0.48)]O(3) (PZT) ring transducer and a polydimethylsiloxane membrane that was attached to a flat side of the transducer. The free surface of the liquid in the cylindrical container can be driven as a static-like convex lens with different curvatures because the higher-order harmonic resonance of the PZT transducer was electrically controlled. Based on a capillary-force-dominant design, the activated liquid lens maintained surface curvature in an arbitrary orientation without a gravitational effect. Profiles of the liquid lenses were characterized with the driving voltages of the transducer ranging from 12 to 60 V peak-to-peak (Vpp) at a resonant frequency of 460 kHz. The temperature effects on the lenses caused by the continuous operation of the transducer were measured. Images showed the various curvatures of the lenses with a range of actuation voltages. A change in focal length of eight times (5.72 to 46.03 cm) was demonstrated within the 10 Vpp variation of the driving voltage. For the characterized liquid lenses, the distortion was less than 2%, and the modulation transfer function reached 63 line pairs per mm (lp/mm) using ZEMAX analysis.

15.
Sensors (Basel) ; 13(10): 13543-59, 2013 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-24113683

RESUMO

This paper presents the microfabrication of an acoustic impedance gradient matching layer on a spherically-shaped piezoelectric ultrasonic transducer. The acoustic matching layer can be designed to achieve higher acoustic energy transmission and operating bandwidth. Also included in this paper are a theoretical analysis of the device design and a micromachining technique to produce the novel transducer. Based on a design of a lead titanium zirconium (PZT) micropillar array, the constructed gradient acoustic matching layer has much better acoustic transmission efficiency within a 20-50 MHz operation range compared to a matching layer with a conventional quarter-wavelength thickness Parylene deposition. To construct the transducer, periodic microcavities are built on a flexible copper sheet, and then the sheet forms a designed curvature with a ball shaping. After PZT slurry deposition, the constructed PZT micropillar array is released onto a curved thin PZT layer. Following Parylene conformal coating on the processed PZT micropillars, the PZT micropillars and the surrounding Parylene comprise a matching layer with gradient acoustic impedance. By using the proposed technique, the fabricated transducer achieves a center frequency of 26 MHz and a -6 dB bandwidth of approximately 65%.


Assuntos
Aumento da Imagem/instrumentação , Membranas Artificiais , Transdutores , Ultrassonografia/instrumentação , Módulo de Elasticidade , Impedância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
PLoS One ; 17(6): e0269746, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35696403

RESUMO

The accurate prediction of reference crop evapotranspiration is of great significance to climate research and regional agricultural water management. In order to realize the high-precision prediction of ETO in the absence of meteorological data, this study use XGBoost to select key influencing factors and BP algorithm to construct ETO prediction model of 12 meteorological stations in South West China in this study. ACO, CSO and CS algorithms are used to optimize the model and improve the adaptability of the model. The results show that Tmax, n and Ra can be used as the input combination of ETO model construction, and Tmax is the primary factor affecting ETO. ETO model constructed by BP algorithm has good goodness of fit with the ETO calculated by FAO-56 PM and ACO, CSO and CS have significant optimization effect on BP algorithm, among which CSO algorithm has the best optimization ability on BP, with RMSE, R2, MAE, NSE, GPI ranging 0.200-0.377, 0.932-0.984, 0.140-0.261, 0.920-0.984, 1.472-2.000, GPI ranking is 1-23. Therefore, the input combination (Tmax, n and Ra) and CSO-BP model are recommended as a simplified model for ETO prediction in Southwest China.


Assuntos
Algoritmos , Meteorologia , Agricultura , China , Clima
17.
Biomed Microdevices ; 13(1): 169-77, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20978854

RESUMO

The present paper examined a novel micromachined column structured Ion Polymer Metal Composite (IPMC) actuator with multidirectional control capability. The developed 4-electrode transducer enclosed a section of optical fiber, thereby allowing electronic directional control of conducted laser light. The fabricated device with IPMC actuator dimensions of 5 mm x 2 mm x 1 mm reached a maximum displacement of 400 µm when a square wave of 9 V was applied to the top-bottom electrode pair. Displacements in different directions and moving angles were characterized with side-side and top-right electrode pairs connected to the actuating signals. Furthermore, the generating moment per volt per second by the transducer was analyzed. The maximum value of approximately 200 µN*m/V/s was displayed when the device actuated with the side-side electrode pair. Controlling the developed IPMC actuator moved the laser beam in multiple directions. This device could be promising for biomedical applications such as microendoscopic ocular surgery.


Assuntos
Tecnologia Biomédica/instrumentação , Microtecnologia/instrumentação , Fibras Ópticas , Compostos Organometálicos/química , Polímeros/química , Transdutores , Eletrodos , Endoscopia , Lasers
18.
Exp Parasitol ; 127(2): 460-6, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20971107

RESUMO

Controversy exists concerning whether cattle and water buffalo sustain infections with cysts of distinct arrays of species in the genus Sarcocystis. In particular, morphologically similar parasites have been alternately ascribed to Sarcocystis cruzi or to Sarcocystis levinei, depending on their occurrence in cattle or water buffalo. We used light and transmission electron microscopy, genetic analysis, and experimental infections of definitive canine hosts to determine whether consistent differences could be identified from parasites derived from several natural infections of each host, examining several tissue types (esophagus, skeletal muscles, and heart). Cysts derived from cattle and water buffalo shared similar structure; variation among 18S rRNA sequences did not segregate consistently according to intermediate host type; parasites derived from cattle and water buffalo induced similar outcomes in the canine definitive host. One cattle specimen harbored unusually large (macroscopic) sarcocysts which nonetheless conformed to previously reported ultrastructural and genetic features of S. cruzi. Finding no consistent basis to differentiate between them, we conclude that the parasites infecting each host and tissue type correspond to S. cruzi. In our sample, no phylogenetically distinct taxon was sampled which might correspond to a distinct taxon previously described as S. levinei. Either that taxon was missed by our sampling effort, or it may represent a junior synonym to S. cruzi, which would then cycle between dogs and a broader range of intermediate bovine hosts than was previously considered.


Assuntos
Búfalos/parasitologia , Sarcocystis/isolamento & purificação , Sarcocistose/veterinária , Animais , Bovinos , DNA de Protozoário/química , DNA Ribossômico/química , Cães , Esôfago/parasitologia , Coração/parasitologia , Dados de Sequência Molecular , Músculo Esquelético/parasitologia , Filogenia , RNA Ribossômico 18S/genética , Sarcocystis/classificação , Sarcocystis/genética , Sarcocystis/ultraestrutura , Sarcocistose/parasitologia
19.
Mater Sci Eng C Mater Biol Appl ; 114: 111047, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32994009

RESUMO

This study presents a state-of-the-art soft and biocompatible transducer capable of detecting vessel inner-wall pressure for biomedical applications. The device includes a 3D electroactive polymer core element encapsulated by polydimethylsiloxane with an ellipsoidal structure. The device produces a voltage output when its sensing mechanism experiences different pressures, resulting in deformation at different orientations. Thus, it can be employed to detect the pressure exerted by inner vessel walls of different stiffness values. The output voltage is induced by the strain experienced by the sensing mechanism of the device without the need for any external electrical power source. The core element, which is made of an ionic polymer-metal composite, possesses a unique hollow design; this allows a catheter to pass through, and the core element can be anchored at an arbitrary position on the catheter. We also demonstrate that the fabricated device can be integrated with a medically used percutaneous transluminal angioplasty balloon catheter to form a smart sensing module. This module can detect different levels of fat accumulation around the inner wall of a blood vessel phantom. Evaluating vessel blockage and stiffness using the signals acquired from the developed device is discussed.


Assuntos
Angioplastia com Balão , Catéteres , Polímeros , Transdutores de Pressão
20.
Appl Opt ; 48(18): 3284-90, 2009 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-19543333

RESUMO

Controlled injection of fluid into a flexible lens chamber has previously produced tunable spherical lenses with spherical aberration problems. This paper presents a novel fluidic-controlled meniscus/biconvex lens system with relatively low distortion. The lens fabrication method is described and manufactured lenses are characterized for different processing parameters. Images captured through one of our lenses for a range of different pressures are presented. A change in focal length of five times (19.1-80.8 cm) is demonstrated. The focal length shows a quadratic relation to the applied pressure (0-5 kPa). For the simple prototype lens, distortion is less than 5% and relative illumination is above 0.74 by ZEMAX analysis.


Assuntos
Lentes , Microfluídica/instrumentação , Desenho Assistido por Computador , Módulo de Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA