Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Neuroimage ; 297: 120689, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38880311

RESUMO

A new MRI technique is presented for three-dimensional fast simultaneous whole brain mapping of myelin water fraction (MWF), T1, proton density (PD), R2*, magnetic susceptibility (QSM), and B1 transmit field (B1+). Phantom and human (N = 9) datasets were acquired using a dual-flip-angle blipped multi-gradient-echo (DFA-mGRE) sequence with a stack-of-stars (SOS) trajectory. Images were reconstructed using a subspace-based algorithm with a locally low-rank constraint. A novel joint-sparsity-constrained multicomponent T2*-T1 spectrum estimation (JMSE) algorithm is proposed to correct for the T1 saturation effect and B1+/B1- inhomogeneities in the quantification of MWF. A tissue-prior-based B1+ estimation algorithm was adapted for B1 correction in the mapping of T1 and PD. In the phantom study, measurements obtained at an acceleration factor (R) of 12 using prospectively under-sampled SOS showed good consistency (R2 > 0.997) with Cartesian reference for R2*/T1app/M0app. In the in vivo study, results of retrospectively under-sampled SOS with R = 6, 12, 18, showed good quality (structure similarity index measure > 0.95) compared with those of fully-sampled SOS. Besides, results of prospectively under-sampled SOS with R = 12 showed good consistency (intraclass correlation coefficient > 0.91) with Cartesian reference for T1/PD/B1+/MWF/QSM/R2*, and good reproducibility (coefficient of variation < 7.0 %) in the test-retest analysis for T1/PD/B1+/MWF/R2*. This study has demonstrated the feasibility of simultaneous whole brain multiparametric mapping with a two-minute scan using the DFA-mGRE SOS sequence, which may overcome a major obstacle for neurological applications of multiparametric MRI.


Assuntos
Encéfalo , Imagens de Fantasmas , Humanos , Masculino , Adulto , Encéfalo/diagnóstico por imagem , Algoritmos , Feminino , Processamento de Imagem Assistida por Computador/métodos , Mapeamento Encefálico/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética Multiparamétrica/métodos
2.
Polymers (Basel) ; 16(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38611271

RESUMO

Stretchable ionogels, as soft ion-conducting materials, have generated significant interest. However, the integration of multiple functions into a single ionogel, including temperature tolerance, self-adhesiveness, and stability in diverse environments, remains a challenge. In this study, a new class of fluorine-containing ionogels was synthesized through photo-initiated copolymerization of fluorinated hexafluorobutyl methacrylate and butyl acrylate in a fluorinated ionic liquid 1-butyl-3-methyl imidazolium bis (trifluoromethylsulfonyl) imide. The resulting ionogels demonstrate good stretchability with a fracture strain of ~1300%. Owing to the advantages of the fluorinated network and the ionic liquid, the ionogels show excellent stability in air and vacuum, as well as in various solvent media such as water, sodium chloride solution, and hexane. Additionally, the ionogels display impressive wide temperature tolerance, functioning effectively within a wide temperature range from -60 to 350 °C. Moreover, due to their adhesive properties, the ionogels can be easily attached to various substrates, including plastic, rubber, steel, and glass. Sensors made of these ionogels reliably respond to repetitive tensile-release motion and finger bending in both air and underwater. These findings suggest that the developed ionogels hold great promise for application in wearable devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA