Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 104(2): 203-212, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38932584

RESUMO

BACKGROUND: Intravascular lithotripsy (IVL) combined with rotational atherectomy (RA), known as Rotatripsy, is used to treat severe coronary artery calcification (CAC), though data on efficacy, midterm safety and use sequence is limited. We aimed to identify indicators for Rotatripsy use and to assess its safety and success rates, both acutely and at 1-year follow-up. METHODS: Patients undergoing Rotatripsy for severe CAC across six centers from May 2019 to December 2023 were included. Demographic, clinical, procedural and follow-up data were collected. Efficacy endpoints included device success (delivery of the RA-burr and IVL-balloon across the target lesion and administration of therapy without related complications), technical success (TIMI 3 flow and residual stenosis <30% by quantitative coronary analysis) and procedural success [composite of technical success with absence of in-hospital major adverse cardiovascular events (MACE: cardiac death, myocardial infarction or target vessel revascularization). Safety endpoints comprised Rotatripsy-related complications and MACE at 1-year follow-up. RESULTS: A total of 114 patients (75 ± 9 years, 78% male) underwent Rotatripsy for 120 lesions. In the majority of procedures RA was followed by IVL, mostly electively (n = 68, 57%) but also for balloon underexpansion (n = 37, 31%) and stent crossing failure (n = 1, 1%). Diverse and complex target lesions were addressed with an average SYNTAX score of 24.6 ± 13.0. Device, technical and procedural success were 97%, 94% and 93%, respectively. Therapy-related complications included two (2%) coronary perforations, one (1%) coronary dissection and one (1%) burr entrapment. At 1-year follow-up(present in 77(67%) patients), MACE occurred in 7(9%) cases. CONCLUSIONS: Over a 1-year follow-up period, Rotatripsy was safe and effective, predominantly using RA electively before IVL.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Litotripsia , Índice de Gravidade de Doença , Calcificação Vascular , Humanos , Masculino , Feminino , Idoso , Fatores de Tempo , Aterectomia Coronária/efeitos adversos , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Calcificação Vascular/mortalidade , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Idoso de 80 Anos ou mais , Litotripsia/efeitos adversos , Fatores de Risco , Estudos Retrospectivos , Estados Unidos
2.
Eur Heart J ; 43(2): 153-163, 2022 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-34580705

RESUMO

AIM: Using proteomics, we previously found that serum levels of glycosylated (Glyc) forms of apolipoprotein J (ApoJ), a cytoprotective and anti-oxidant protein, decrease in the early phase of acute myocardial infarction (AMI). We aimed to investigate: (i) ApoJ-Glyc intracellular distribution and secretion during ischaemia; (ii) the early changes in circulating ApoJ-Glyc during AMI; and (iii) associations between ApoJ-Glyc and residual ischaemic risk post-AMI. METHODS AND RESULTS: Glycosylated apolipoprotein J was investigated in: (i) cells from different organ/tissue origin; (ii) a pig model of AMI; (iii) de novo AMI patients (n = 38) at admission within the first 6 h of chest pain onset and without troponin T elevation at presentation (early AMI); (iv) ST-elevation myocardial infarction patients (n = 212) who were followed up for 6 months; and (v) a control group without any overt cardiovascular disease (n = 144). Inducing simulated ischaemia in isolated cardiac cells resulted in an increased intracellular accumulation of non-glycosylated ApoJ forms. A significant decrease in ApoJ-Glyc circulating levels was seen 15 min after ischaemia onset in pigs. Glycosylated apolipoprotein J levels showed a 45% decrease in early AMI patients compared with non-ischaemic patients (P < 0.0001), discriminating the presence of the ischaemic event (area under the curve: 0.934; P < 0.0001). ST-elevation myocardial infarction patients with lower ApoJ-Glyc levels at admission showed a higher rate of recurrent ischaemic events and mortality after 6-month follow-up (P = 0.008). CONCLUSIONS: These results indicate that ischaemia induces an intracellular accumulation of non-glycosylated ApoJ and a reduction in ApoJ-Glyc secretion. Glycosylated apolipoprotein J circulating levels are reduced very early after ischaemia onset. Its continuous decrease indicates a worsening in the evolution of the cardiac event, likely identifying patients with sustained ischaemia after AMI.


Assuntos
Clusterina , Doença da Artéria Coronariana , Infarto do Miocárdio , Animais , Clusterina/sangue , Clusterina/química , Doença da Artéria Coronariana/sangue , Glicosilação , Humanos , Isquemia , Infarto do Miocárdio/sangue , Suínos , Troponina T
3.
Eur Heart J ; 43(7): 641-650, 2022 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-34463727

RESUMO

AIMS: Severe mitral regurgitation (MR) following acute myocardial infarction (MI) is associated with high mortality rates and has inconclusive recommendations in clinical guidelines. We aimed to report the international experience of patients with secondary MR following acute MI and compare the outcomes of those treated conservatively, surgically, and percutaneously. METHODS AND RESULTS: Retrospective international registry of consecutive patients with at least moderate-to-severe MR following MI treated in 21 centres in North America, Europe, and the Middle East. The registry included patients treated conservatively and those having surgical mitral valve repair or replacement (SMVR) or percutaneous mitral valve repair (PMVR) using edge-to-edge repair. The primary endpoint was in-hospital mortality. A total of 471 patients were included (43% female, age 73 ± 11 years): 205 underwent interventions, of whom 106 were SMVR and 99 PMVR. Patients who underwent mitral valve intervention were in a worse clinical state (Killip class ≥3 in 60% vs. 43%, P < 0.01), but yet had lower in-hospital and 1-year mortality compared with those treated conservatively [11% vs. 27%, P < 0.01 and 16% vs. 35%, P < 0.01; adjusted hazard ratio (HR) 0.28, 95% confidence interval (CI) 0.18-0.46, P < 0.01]. Surgical mitral valve repair or replacement was performed earlier than PMVR [median of 12 days from MI date (interquartile range 5-19) vs. 19 days (10-40), P < 0.01]. The immediate procedural success did not differ between SMVR and PMVR (92% vs. 93%, P = 0.53). However, in-hospital and 1-year mortality rates were significantly higher in SMVR than in PMVR (16% vs. 6%, P = 0.03 and 31% vs. 17%, P = 0.04; adjusted HR 3.75, 95% CI 1.55-9.07, P < 0.01). CONCLUSIONS: Early intervention may mitigate the poor prognosis associated with conservative therapy in patients with post-MI MR. Percutaneous mitral valve repair can serve as an alternative for surgery in reducing MR for high-risk patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Infarto do Miocárdio , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Estudos Retrospectivos , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 99(7): 2008-2015, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35373887

RESUMO

BACKGROUND: Discordant physiology and anatomy may occur when nonsevere angiographic stenosis has positive physiology as well as the opposite situation. AIM: To underline the reasons behind the discrepancy in physiology and anatomy and to summarize the information that coronary imaging may add to physiology. METHODS: A review of the published literature on physiology and intravascular imaging assessment of intermediate lesions was carried out. RESULTS: The limitations of angiography, the possibility of an underlying diffuse disease, the presence of a "grey zone" in both techniques, the amount of myocardial mass that subtends the stenosis, and plaque vulnerability may play a role in such discrepancy. Intracoronary imaging has a poor diagnostic accuracy compared to physiology. However, it may add information about plaque vulnerability that might be useful in deciding whether to treat or not a certain lesion. CONCLUSIONS: Coronary revascularization is recommended for patients with ischemia based on physiology. Intracoronary imaging adds information on plaque vulnerability and can help on the decision whether to revascularize or not a lesion.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Constrição Patológica/patologia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/terapia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 99(7): 2018-2025, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35366386

RESUMO

BACKGROUND: The index of microvascular resistance (IMR) is an established tool to assess the status of coronary microcirculation. However, the need for a pressure wire and hyperemic agents have limited its routine use and have led to the development of angiography-derived pressure-wire-free methods (angiography-derived IMR [IMRAngio]). In this review and meta-analysis, we aim to assess the global diagnosis accuracy of IMRAngio versus IMR. METHODS: A systematic review of the literature was performed. Studies directly evaluating IMRAngio versus IMR were considered eligible. Pooled values of diagnostic test and summary receiver operator curve were calculated. RESULTS: Seven studies directly comparing IMRAngio versus IMR were included (687 patients; 807 vessels). Pooled sensitivity, specificity, +likelihood ratio (LR), and -LR were 82%, 83%, 4.5, and 0.26 respectively. Pooled accuracy was 83% while pooled positive predictive value and negative predictive value were 76% and 85%, respectively. Comparable results were obtained when analyzing by clinical scenario (acute and nonacute coronary syndromes). CONCLUSION: IMRAngio shows a good diagnostic performance for the prediction of abnormal IMR.


Assuntos
Circulação Coronária , Vasos Coronários , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Humanos , Microcirculação , Valor Preditivo dos Testes , Resultado do Tratamento , Resistência Vascular
6.
Catheter Cardiovasc Interv ; 99(5): 1619-1625, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35043543

RESUMO

BACKGROUND AND OBJECTIVES: Evidence regarding redo percutaneous interventions for recurrent mitral regurgitation is scarce. We ought to evaluate procedural and clinical outcomes of repeated edge-to-edge transcatheter mitral valve repair (TMVR) interventions. METHODS: This multicenter study collected individual data from eight high-volume TMVR Centers in Spain. Between 2012 and 2020, all patients undergoing a second edge-to-edge TMVR intervention (Redo) were included in the study. RESULTS: Among a total of 1028 procedures, 31 patients (3%) with residual MR ≥ 3 at follow-up underwent a second procedure (Redo). Redo intervention was mainly conducted between the first and second year after the first procedure. The most common cause of MR progression was partial detachment (46.7%) followed by LV remodeling (35.5%). Procedural success was achieved in 87% of cases. After a mean follow-up of 1.75 ± 1.54 years, all-cause and cardiovascular mortality were 48.1% and 25%, respectively. Nearly half of the patients (48.1%) required at least one hospital admission for CHF within the follow-up period. However, most of the patients presented symptomatic improvement as depicted by an NYHA class ≤2. Elective mitral surgery was conducted in only one patient at follow-up due to insufficient MR reduction. CONCLUSIONS: According to our findings, redo edge-to-edge TMVR interventions were feasible and safe with a high procedural success rate. Clinical and echocardiographic follow-up showed however modest long-term results in this specific setting.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 100(2): 199-206, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35723684

RESUMO

AIM: Microvascular resistance reserve (MRR) as derived from continuous intracoronary thermodilution specifically quantifies microvasculature function. As originally described, the technique necessitates reinstrumentation of the artery and manual reprogramming of the infusion pump when performing resting and hyperemic measurements. To simplify and to render this procedure operator-independent, we developed a fully automated method. The aim of the present study is to validate the automated procedure against the originally described one. METHODS AND RESULTS: For the automated procedure, an infusion pump was preprogrammed to allow paired resting-hyperemic thermodilution assessment without interruption. To validate the accuracy of this new approach, 20 automated measurements were compared to those obtained in the same vessels with conventional paired resting-hyperemic thermodilution measurements (i.e., with a sensor pullback at each infusion rate and manual reprogramming of the infusion pump).  A close correlation between the conventional and the automated measuring technique was found for resting flow (Qrest : r = 0.89, mean bias = 2.52; SD = 15.47), hyperemic flow (Qhyper : r = 0.88, mean bias = -2.65; SD = 27.96), resting microvascular resistance (Rµ-rest : r = 0.90, mean bias = 52.14; SD = 228.29), hyperemic microvascular resistance Rµ-hyper : r = 0.92, mean bias = 12.95; SD = 57.80), and MRR (MRR: r = 0.89, mean bias = 0.04, SD = 0.59).  Procedural time was significantly shorter with the automated method (5'25″ ± 1'23″ vs. 4'36″ ± 0'33″, p = 0.013). CONCLUSION: Continuous intracoronary thermodilution-derived measurements of absolute flow, absolute resistance, and MRR can be fully automated. This further shortens and simplifies the procedure when performing paired resting-hyperemic measurements.


Assuntos
Hiperemia , Termodiluição , Automação , Circulação Coronária , Vasos Coronários , Humanos , Microcirculação , Termodiluição/métodos , Resultado do Tratamento , Resistência Vascular
8.
Catheter Cardiovasc Interv ; 97(6): 1259-1267, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33600072

RESUMO

OBJECTIVES: To assess outcomes in patients with acute mitral regurgitation (MR) following acute myocardial infarction (AMI) who received percutaneous mitral valve repair (PMVR) with the MitraClip device and to compare outcomes of patients who developed cardiogenic shock (CS) to those who did not (non-CS). BACKGROUND: Acute MR after AMI may lead to CS and is associated with high mortality. METHODS: This registry analyzed patients with MR after AMI who were treated with MitraClip at 18 centers within eight countries between January 2016 and February 2020. Patients were stratified into CS and non-CS groups. Primary outcomes were mortality and rehospitalization due to heart failure. Secondary outcomes were acute procedural success, functional improvement, and MR reduction. Multivariable Cox regression analysis evaluated association of CS with clinical outcomes. RESULTS: Among 93 patients analyzed (age 70.3 ± 10.2 years), 50 patients (53.8%) experienced CS before PMVR. Mortality at 30 days (10% CS vs. 2.3% non-CS; p = .212) did not differ between groups. After median follow-up of 7 months (IQR 2.5-17 months), the combined event mortality/re-hospitalization was similar (28% CS vs. 25.6% non-CS; p = .793). Likewise, immediate procedural success (90% CS vs. 93% non-CS; p = .793) and need for reintervention (CS 6% vs. non-CS 2.3%, p = .621) or re-admission due to HF (CS 13% vs. NCS 23%, p = .253) at 3 months did not differ. CS was not independently associated with the combined end-point (hazard ratio 1.1; 95% CI, 0.3-4.6; p = .889). CONCLUSIONS: Patients found to have significant MR during their index hospitalization for AMI had similar clinical outcomes with PMVR whether they presented in or out of cardiogenic shock, provided initial hemodynamic stabilization was first achieved before PMVR.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Infarto do Miocárdio , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Infarto do Miocárdio/complicações , Sistema de Registros , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
9.
Expert Rev Med Devices ; 21(3): 187-196, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38155555

RESUMO

INTRODUCTION: Over the last two decades, mitral transcatheter edge-to-edge repair (M-TEER) has become a safe and effective therapy for severe mitral regurgitation in patients deemed at high surgical risk. AREAS COVERED: This review aims to encompass the most relevant and updated evidence in the field of M-TEER from its inception, focusing on clinical and anatomical features for proper patient and device selection. EXPERT OPINION: Growing operator experience and device iterations have resulted in improved clinical outcomes and an expansion of the therapy to patients with complex anatomies and clinical scenarios. Future investigations are warranted to determine the best management options and the most suitable device for every patient with MR.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Seleção de Pacientes , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
10.
Cardiovasc Revasc Med ; 61: 44-51, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37949720

RESUMO

BACKGROUND: The impact on age on the short-term and long-term prognosis in patients with Takotsubo syndrome (TTS) is unclear. We aimed to evaluate whether age has prognostic implications during hospital stay and long-term follow-up of TTS patients. METHODS: 688 consecutive patients were admitted for TTS in 7 tertiary centers from January-2008 to June-2021. We divided our cohort into two groups (patients <75 years and ≥75 years). Clinical, analytical, and hemodynamic variables as well as in-hospital management were registered and compared between groups. Mortality rates during hospital stay and follow-up were assessed. Adverse cardiovascular events (ACE) were defined as the composite of cardiovascular death, heart failure event, acute myocardial infarction, stroke and symptomatic arrhythmia. RESULTS: Median age was 74.7 years and 49.4 % were ≥75 years. 86.9 % were women and 22.3 % were secondary forms of TTS. In-hospital mortality was 3.6 % (1.5 % cardiovascular). Median clinical follow-up was 4.3 years. Mortality during the follow-up period was 23 % (5.0 % cardiovascular) while ACE were 22.5 %, mainly due to heart failure events. Kaplan-Meier curves showed both higher rates of mortality and ACE in ≥75 years group (30.2 % vs 15.8 %; p < 0.001 and 28.3 % vs 16.7 %; p < 0.001). Age was independently associated with higher rates of overall mortality and ACE in patients with TTS. Hypertension, absence of sinus rhythm, Killip class > I and a more impaired coronary microvascular resistance were also associated to ACE in TTS patients. CONCLUSIONS: Advanced age was associated with higher rate of overall mortality and ACE during long-term follow-up in TTS patients.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Cardiomiopatia de Takotsubo , Humanos , Feminino , Idoso , Masculino , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/terapia , Cardiomiopatia de Takotsubo/complicações , Prognóstico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Infarto do Miocárdio/complicações , Hospitalização , Arritmias Cardíacas/complicações
11.
Int J Cardiovasc Imaging ; 40(8): 1671-1682, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38848005

RESUMO

Many lesions in patients undergoing percutaneous coronary intervention (PCI) exhibit significant calcification. Several techniques have been developed to improve outcomes in this setting. However, their impact on coronary microcirculation remains unknown. The aim of this study is to evaluate the influence of plaque modification techniques on coronary microcirculation across patients with severely calcified coronary artery disease. In this multicenter retrospective study, consecutive patients undergoing PCI with either Rotablation (RA) or Shockwave-intravascular-lithotripsy (IVL) were included. Primary endpoint was the impairment of coronary microvascular resistances assessed by Δ angiography-derived index of microvascular resistance (ΔIMRangio) which was defined as the difference in IMRangio value post- and pre-PCI. Secondary endpoints included the development of peri procedural PCI complications (flow-limiting coronary dissection, slow-flow/no reflow during PCI, coronary perforation, branch occlusion, failed PCI, stroke and shock developed during PCI) and 12-month follow-up adverse events. 162 patients were included in the analysis. Almost 80% of patients were male and the left descending anterior artery was the most common treated vessel. Both RA and IVL led to an increase in ΔIMRangio (22.3 and 10.3; p = 0.038, respectively). A significantly higher rate of PCI complications was observed in patients with ΔIMRangio above the median of the cohort (21.0% vs. 6.2%; p = 0.006). PCI with RA was independently associated with higher ΔIMRangio values (OR 2.01, 95% CI: 1.01-4.03; p = 0.048). Plaque modification with IVL and RA during PCI increases microvascular resistance. Evaluating the microcirculatory status in this setting might help to predict clinical and procedural outcomes and to optimize clinical results.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Circulação Coronária , Vasos Coronários , Microcirculação , Intervenção Coronária Percutânea , Placa Aterosclerótica , Valor Preditivo dos Testes , Calcificação Vascular , Resistência Vascular , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Intervenção Coronária Percutânea/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Pessoa de Meia-Idade , Resultado do Tratamento , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Fatores de Risco , Fatores de Tempo , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/fisiopatologia , Calcificação Vascular/terapia , Índice de Gravidade de Doença , Aterectomia Coronária/efeitos adversos
12.
J Clin Med ; 13(15)2024 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-39124675

RESUMO

Background: Patients with cardiogenic shock (CS) and mitral regurgitation (MI) have a prohibitive risk that contraindicates surgical treatment. Although the feasibility of transcatheter edge-to-edge therapy (TEER) has been demonstrated in this setting, the benefit of the combined use of TEER with mechanical circulatory support devices (MCS) has not been studied. The aim of this study was to evaluate the clinical outcomes of TEER in patients with MCS. Methods: The MITRA-ASSIST study is a retrospective multicentre Spanish registry that included patients with MR and CS who underwent TEER in combination with MCS. The primary endpoint was death from any cause at 12 months. The secondary endpoint was a composite of death from any cause or hospitalisation for heart failure at 12 months. Results: A total of twenty-four patients in nine high-volume Spanish centres (66.2 (51-82) years, 70.8% female, EuroSCORE II 20.4 ± 17.8) were included. Acute ST-elevation myocardial infarction was the main CS aetiology (56%), and the most implanted MCS was the intra-aortic balloon pump (82.6%), followed by ECMO (8.7%), IMPELLACP® (4.3%), or a combination of both (4.3%). Procedural success was 95.8%, with 87.5% in-hospital survival. At 12-month follow-up, 25.0% of patients died, and 33.3% had a composite event of death from any cause or hospitalisation for heart failure. Conclusions: TEER in patients with concomitant CS and MR who require MCS appears to be a promising therapeutic alternative with a high device procedural success rate and acceptable mortality and heart failure readmission rates at follow-up.

13.
Expert Rev Cardiovasc Ther ; 21(10): 703-712, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37815845

RESUMO

INTRODUCTION: With the expanding indications of transcatheter aortic valve replacement (TAVR) to younger and low-risk patients, the life expectancy of patients currently undergoing TAVR will likely outlive the durability of transcatheter bioprosthesis. Consequently, the number of failed transcatheter bioprosthesis requiring surgical valve explant or redo TAVR is expected to increase. AREAS COVERED: The aim of this review is to provide an updated overview of redo TAVR for treating degenerated transcatheter bioprosthesis, focusing on pre-procedural planning, potential challenges of coronary reaccess during TAVR-in-TAVR and main outcomes of TAVR explant and redo TAVR. EXPERT OPINION: Patient-tailored device selection and individualized implantation height should be carefully assessed during the index TAVR procedure (weighting between pacemaker avoidance and the potential risk of coronary occlusion in future TAVR-in-TAVR). Future prospective studies comparing safety and clinical outcomes between redo TAVR vs TAVR explant are eagerly awaited.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
14.
Int J Cardiovasc Imaging ; 39(4): 683-693, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36471105

RESUMO

BACKGROUND: Global longitudinal strain (GLS) allows an accurate assessment of left ventricular function with prognostic value. We aimed to evaluate whether the assessment of GLS in the acute phase of Takotsubo syndrome (TTS) provides incremental prognostic value to the degree of impaired microvascular resistance (MR) in TTS patients at 1-year follow-up. METHODS: We recruited patients admitted for TTS who underwent cardiac angiography and echocardiography from January 2017 to June 2020. Left anterior descending coronary artery non-hyperaemic angiography-derived index of microcirculatory resistance (LAD NH-IMRangio) was calculated. NT-proBNP, high-sensitive cardiac troponin T (hs-cTnT), left ventricular ejection fraction (LVEF) and GLS were measured at admission. Major adverse cardiac events (MACE) were defined as the composite of cardiovascular death, repeat hospitalizations for heart failure (HF) and acute myocardial infarctions. RESULTS: 67 patients had both GLS and NH-IMRangio available and were included in the study. Median age was 75.2 years and 88% were women. Rate of MACE at 1-year was 13.4%. Kaplan-Meier curves showed higher rates of MACE at 1-year in patients with both higher LAD NH-IMRangio and GLS values compared with those with higher LAD NH-IMRangio and lower GLS values (33.3% vs. 11.1%; p = 0.049). NT-proBNP levels at admission and the recovery of LVEF were correlated with GLS values while MR and hs-cTnT were not. CONCLUSION: GLS provides incremental prognostic value to the degree of impaired MR in TTS patients. The combination of a poorer GLS with a higher degree of impaired MR was associated with a higher rate of MACE in these patients.


Assuntos
Cardiomiopatia de Takotsubo , Função Ventricular Esquerda , Humanos , Feminino , Idoso , Masculino , Prognóstico , Volume Sistólico , Microcirculação , Deformação Longitudinal Global , Valor Preditivo dos Testes , Cardiomiopatia de Takotsubo/diagnóstico por imagem
15.
J Clin Med ; 12(18)2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37762965

RESUMO

Transcatheter aortic valve replacement (TAVR) is currently the treatment of choice for patients aged ≥75 years with severe aortic stenosis. Preoperative anemia is present in a large proportion of patients and may increase the risk of post-procedural complications. The purpose of this prognostic systematic review was to analyze the impact of baseline anemia on short- and mid-term outcomes following TAVR. A computerized search was performed on PubMed and Web of Science databases for studies published between January 2013 and December 2022. Primary outcomes were 30-day need for transfusion, acute renal failure, 30-day and mid-term mortality, and readmission during the first year post-TAVR. Data were analyzed via random effects model using inverse variance method with 95% confidence intervals. Eleven observational studies met our eligibility criteria and included a total of 12,588 patients. The prevalence of baseline anemia ranged between 39% and 72%, with no relevant sex differences. Patients with preprocedural anemia received more blood transfusions [OR: 2.95 (2.13-4.09)]), and exhibited increased rates of acute kidney injury [OR:1.74 (1.45-2.10)], short-term mortality [OR: 1.47 (1.07-2.01], and mid-term [OR: 1.89 (1.58-2.25)] mortality following TAVR compared with those without anemia. Baseline anemia determined an increased risk for blood transfusion, acute kidney injury, and short/mid-term mortality among TAVR recipients.

16.
Rev Esp Cardiol (Engl Ed) ; 76(10): 767-773, 2023 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36804557

RESUMO

INTRODUCTION AND OBJECTIVES: The cusp overlap technique (COT) has been proposed to reduce conduction disturbances (CD) after transcatheter aortic valve implantation (TAVI) with self-expanding supra-annular devices, but there are scarce data on COT with intra-annular valves. The aim of this study was to determine whether the use of the COT during Portico implantation results in higher valve implantation and lower rates of CD. METHODS: We included 85 patients undergoing TAVI with the Portico FlexNav system: 43 retrospective patients using the standard 3-cusp view and 42 prospective patients with the COT. Primary endpoints were implantation depth and new-onset CD (composite outcome of new-onset left bundle branch block and new permanent pacemaker implantation). RESULTS: COT resulted in a higher implantation depth (noncoronary cusp: 4.9±3.9 vs 7.4±3.0; P=.005) and lower new-onset CD (31.0% vs 58.1%; P=.012), with a tendency toward a lower need for permanent pacemaker implantation (14.3% vs 30.2%, P=.078; 7.7% vs 31.0%; P=.011 in patients without pre-existing right bundle branch block). Transvalvular aortic gradients were slightly lower with COT (8.7±3.7 vs 11.0±6.1; P=.044). There were no differences in technical success or major procedure-related complications. On multivariate analysis, COT use was associated with a lower risk of new-onset CD. CONCLUSIONS: Use of the COT during Portico implantation is feasible and facilitates a higher valve implant, which in turn may help to reduce rates of new-onset CD.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
17.
Cardiovasc Revasc Med ; 47: 40-45, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36182565

RESUMO

BACKGROUND: Takotsubo syndrome (TTS) is often associated with symptoms of heart failure (HF) during the acute phase of the disease. 3-dimensional optical coherence tomography (OCT) may be used to assess the extent of angiographically silent underlying coronary artery disease (CAD). This study aims to use an artificial intelligence algorithm to analyze OCT findings and to determine whether the presence of pre-existing CAD predisposes TTS patients to present HF at admission. METHODS: This is an observational and retrospective study that enrolled TTS patients who underwent coronary angiography and OCT examination of left anterior descending (LAD) coronary artery. Plaque characterization was automatically analyzed via an artificial intelligence model from OCT images. An angiography-derived index of microcirculatory resistance (IMRangio) using the optic flow ratio (OFR) was calculated to assess its correlation with plaque volumes. RESULTS: Thirty-seven patients were included (94.6 % women) with a median age of 82.0 years. Ten patients (27 %) showed some degree of HF at admission. Sixty-seven coronary non-obstructive plaques were analyzed. Tissue compositional analysis showed that patients with HF had an increased overall plaque volume (79.0 mm3 vs 28.6 mm3; p = 0.011) and longer plaque lesion length (12.8 mm vs 7.2 mm; p = 0.006). Patients with HF also showed an increased percentage of lipidic and calcified plaque tissue (26.4 % vs 13.4 %; p = 0.019 and 4.5 % vs 0.0 %; p = 0.001, respectively). A moderate positive correlation was found between global overall plaque volume and IMRangio. CONCLUSION: Increased overall plaque volume was associated with the development of HF during the acute phase of TTS, suggesting that the presence of angiographically silent underlying CAD may play a prognostic role in these patients.


Assuntos
Doença da Artéria Coronariana , Insuficiência Cardíaca , Placa Aterosclerótica , Cardiomiopatia de Takotsubo , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/diagnóstico por imagem , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Inteligência Artificial , Microcirculação , Angiografia Coronária/métodos , Placa Aterosclerótica/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Insuficiência Cardíaca/etiologia , Hospitais
18.
EuroIntervention ; 19(2): e155-e166, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-36809253

RESUMO

BACKGROUND: A bolus thermodilution-derived index of microcirculatory resistance (IMR) has emerged as the standard for assessing coronary microvascular dysfunction (CMD). Continuous thermodilution has recently been introduced as a tool to quantify absolute coronary flow and microvascular resistance directly. Microvascular resistance reserve (MRR) derived from continuous thermodilution has been proposed as a novel metric of microvascular function, which is independent of epicardial stenoses and myocardial mass. AIMS: We aimed to assess the reproducibility of bolus and continuous thermodilution in assessing coronary microvascular function. METHODS: Patients with angina and non-obstructive coronary artery disease (ANOCA) at angiography were prospectively enrolled. Bolus and continuous intracoronary thermodilution measurements were obtained in duplicate in the left anterior descending artery (LAD). Patients were randomly assigned in a 1:1 ratio to undergo either bolus thermodilution first or continuous thermodilution first. RESULTS: A total of 102 patients were enrolled. The mean fractional flow reserve (FFR) was 0.86±0.06. Coronary flow reserve (CFR) calculated with continuous thermodilution (CFRcont) was significantly lower than bolus thermodilution-derived CFR (CFRbolus; 2.63±0.65 vs 3.29±1.17; p<0.001). CFRcont showed a higher reproducibility than CFRbolus (variability: 12.7±10.4% continuous vs 31.26±24.85% bolus; p<0.001). MRR showed a higher reproducibility than IMR (variability 12.4±10.1% continuous vs 24.2±19.3% bolus; p<0.001). No correlation was found between MRR and IMR (r=0.1, 95% confidence interval: -0.09 to 0.29; p=0.305). CONCLUSIONS: In the assessment of coronary microvascular function, continuous thermodilution demonstrated significantly less variability on repeated measurements than bolus thermodilution.


Assuntos
Circulação Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Termodiluição , Microcirculação , Reprodutibilidade dos Testes , Resistência Vascular , Cateterismo Cardíaco , Vasos Coronários , Angiografia Coronária
19.
Rev Esp Cardiol (Engl Ed) ; 76(1): 25-31, 2023 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35691867

RESUMO

INTRODUCTION AND OBJECTIVES: The PASCAL system is a novel device for transcatheter mitral valve repair based on the edge-to-edge concept. The unique features of this device might have a relevant impact on the repair outcomes. There are few data on clinical outcomes in real-life registries. The aim of this study was to report the early Iberian experience (Spain and Portugal) of the PASCAL system. METHODS: Procedural and 30-day outcomes were investigated in consecutive patients with symptomatic severe mitral regurgitation (MR) treated with the PASCAL system at 10 centers. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE) at 30 days. RESULTS: We included 68 patients (age, 75 [68-81] years; 38% women; EuroSCORE II 4.5%). MR etiology was degenerative in 25%, functional in 65%, and mixed in 10%. A total of 71% of patients were in New York Heart Association (NYHA) functional class≥III. Technical success was achieved in 96% and independent capture was used in 73% of procedures. In the treated population, MR at discharge was≤2+ in 100%, with no in-hospital deaths. At 30 days, the MAE rate was 5.9%, the all-cause mortality rate was 1.6%, 98% were in NYHA functional class≤II, and 95% had MR≤2+ (P<.001). CONCLUSIONS: Transcatheter mitral valve repair with the PASCAL system was safe and effective, with high procedural success and low rates of MAE. At 30 days, MR was significantly reduced, with a significant improvement in functional status.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento
20.
J Clin Med ; 12(12)2023 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-37373808

RESUMO

BACKGROUND: The timing and selection of optimal candidates for mitral transcatheter edge-to-edge valve repair remains to be fully determined, especially in cases with severely depressed left ventricular ejection fraction (LVEF). The objective of this study is to evaluate the prognostic value of myocardial strain (LVGLS) in this setting. METHODS: Retrospectively, 172 consecutive patients with LVEF ≤40% and severe MR treated with MitraClip were included. Four groups were generated according to the LVEF (<30% or ≥30%) and median LVGLS. The primary end-point was cardiovascular mortality. RESULTS: Procedural success was high (96.5%) and complications were rare. At one-year follow-up, 82.5% of patients maintained MR grade ≤2, 79.2% were at a NYHA class ≤II and a reduction of 80% in heart failure admissions was observed in all groups. Interestingly, among patients with a more depressed LVEF, LVGLS was found to be an independent predictor for cardiovascular mortality (HR: 3.3; 95% CI: 1.1-10, p = 0.023). CONCLUSIONS: Mitral valve repair with MitraClip is safe and it improves the mid-term functional class of patients regardless of LVEF. LVGLS can help in the selection of optimal candidates and timing for this procedure, as well as in the recognition of those patients with worse prognoses.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA