Radiology ; 306(1): 229-236, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36066364

RESUMO

Background Photon-counting detector (PCD) CT and deep learning noise reduction may improve spatial resolution at lower radiation doses compared with energy-integrating detector (EID) CT. Purpose To demonstrate the diagnostic impact of improved spatial resolution in whole-body low-dose CT scans for viewing multiple myeloma by using PCD CT with deep learning denoising compared with conventional EID CT. Materials and Methods Between April and July 2021, adult participants who underwent a whole-body EID CT scan were prospectively enrolled and scanned with a PCD CT system in ultra-high-resolution mode at matched radiation dose (8 mSv for an average adult) at an academic medical center. EID CT and PCD CT images were reconstructed with Br44 and Br64 kernels at 2-mm section thickness. PCD CT images were also reconstructed with Br44 and Br76 kernels at 0.6-mm section thickness. The thinner PCD CT images were denoised by using a convolutional neural network. Image quality was objectively quantified in two phantoms and a randomly selected subset of participants (10 participants; median age, 63.5 years; five men). Two radiologists scored PCD CT images relative to EID CT by using a five-point Likert scale to detect findings reflecting multiple myeloma. The scoring for the matched reconstruction series was blinded to scanner type. Reader-averaged scores were tested with the null hypothesis of equivalent visualization between EID and PCD. Results Twenty-seven participants (median age, 68 years; IQR, 61-72 years; 16 men) were included. The blinded assessment of 2-mm images demonstrated improvement in viewing lytic lesions, intramedullary lesions, fatty metamorphosis, and pathologic fractures for PCD CT versus EID CT (P < .05 for all comparisons). The 0.6-mm PCD CT images with convolutional neural network denoising also demonstrated improvement in viewing all four pathologic abnormalities and detected one or more lytic lesions in 21 of 27 participants compared with the 2-mm EID CT images (P < .001). Conclusion Ultra-high-resolution photon-counting detector CT improved the visibility of multiple myeloma lesions relative to energy-integrating detector CT. © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Aprendizado Profundo , Mieloma Múltiplo , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X/métodos , Feminino
2.
Eur Radiol ; 33(8): 5309-5320, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37020069

RESUMO

The X-ray detector is a fundamental component of a CT system that determines the image quality and dose efficiency. Until the approval of the first clinical photon-counting-detector (PCD) system in 2021, all clinical CT scanners used scintillating detectors, which do not capture information about individual photons in the two-step detection process. In contrast, PCDs use a one-step process whereby X-ray energy is converted directly into an electrical signal. This preserves information about individual photons such that the numbers of X-ray in different energy ranges can be counted. Primary advantages of PCDs include the absence of electronic noise, improved radiation dose efficiency, increased iodine signal and the ability to use lower doses of iodinated contrast material, and better spatial resolution. PCDs with more than one energy threshold can sort the detected photons into two or more energy bins, making energy-resolved information available for all acquisitions. This allows for material classification or quantitation tasks to be performed in conjunction with high spatial resolution, and in the case of dual-source CT, high pitch, or high temporal resolution acquisitions. Some of the most promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value. These include imaging of the inner ear, bones, small blood vessels, heart, and lung. This review describes the clinical benefits observed to date and future directions for this technical advance in CT imaging. KEY POINTS: • Beneficial characteristics of photon-counting detectors include the absence of electronic noise, increased iodine signal-to-noise ratio, improved spatial resolution, and full-time multi-energy imaging. • Promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value and applications requiring multi-energy data simultaneous with high spatial and/or temporal resolution. • Future applications of PCD-CT technology may include extremely high spatial resolution tasks, such as the detection of breast micro-calcifications, and quantitative imaging of native tissue types and novel contrast agents.


Assuntos
Compostos de Iodo , Iodo , Humanos , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Meios de Contraste , Fótons , Imagens de Fantasmas
3.
AJR Am J Roentgenol ; 220(4): 551-560, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36259593

RESUMO

Photon-counting detector (PCD) CT has emerged as a novel imaging modality that represents a fundamental shift in the way that CT systems detect x-rays. After pre-clinical and clinical investigations showed benefits of PCD CT for a range of imaging tasks, the U.S. FDA in 2021 approved the first commercial PCD CT system for clinical use. The technologic features of PCD CT are particularly well suited for musculo-skeletal imaging applications. Advantages of PCD CT compared with conventional energy-integrating detector (EID) CT include smaller detector pixels and excellent geometric dose efficiency that enable imaging of large joints and central skeletal anatomy at ultrahigh spatial resolution; advanced multienergy spectral postprocessing that allows quantification of gout deposits and generation of virtual noncalcium images for visualization of bone edema; improved metal artifact reduction for imaging of orthopedic implants; and higher CNR and suppression of electronic noise. Given substantially improved cortical and trabecular detail, PCD CT images more clearly depict skeletal abnormalities, including fractures, lytic lesions, and mineralized tumor matrix. The purpose of this article is to review, by use of clinical examples comparing EID CT and PCD CT, the technical features of PCD CT and their associated impact on musculoskeletal imaging applications.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Raios X
4.
Acta Haematol ; 146(5): 419-423, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37339614

RESUMO

Photon counting detector (PCD) computed tomography (CT) is a paradigm-shifting innovation in CT imaging which was recently granted approval for clinical use by the US Food and Drug Administration. PCD-CT allows the generation of multi-energy images with increased contrast and scanning speed or ultra-high spatial resolution (UHR) images with lower radiation doses, compared to the currently used energy integrating detector (EID) CT. Since the recognition of bone disease related to multiple myeloma is important for the diagnosis and management of patients, the advent of PCD-CT heralds a new era in superior diagnostic evaluation of myeloma bone disease. In a first-in-human pilot study, patients with multiple myeloma were imaged with UHR-PCD-CT to validate and establish the utility of this technology in routine imaging and clinical care. We describe 2 cases from that cohort to highlight the superior imaging performance and diagnostic potential of PCD-CT for multiple myeloma compared to clinical standard EID-CT. We also discuss how the advanced imaging capabilities from PCD-CT enhances clinical diagnostics to improve care and overall outcomes for patients.


Assuntos
Mieloma Múltiplo , Humanos , Mieloma Múltiplo/diagnóstico por imagem , Projetos Piloto , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X/métodos
5.
Skeletal Radiol ; 52(9): 1651-1659, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36971838

RESUMO

OBJECTIVE: The feasibility of low-dose photon-counting detector (PCD) CT to measure alpha and acetabular version angles of femoroacetabular impingement (FAI). MATERIAL AND METHODS: FAI patients undergoing an energy-integrating detector (EID) CT underwent an IRB-approved prospective ultra-high-resolution (UHR) PCD-CT between 5/2021 and 12/2021. PCD-CT was dose-matched to the EID-CT or acquired at 50% dose. Simulated 50% dose EID-CT images were generated. Two radiologists evaluated randomized EID-CT and PCD-CT images and measured alpha and acetabular version angles on axial image slices. Image quality (noise, artifacts, and visualization of cortex) and confidence in non-FAI pathology were rated on a 4-point scale (3 = adequate). Preference tests of standard dose PCD-CT, 50% dose PCD-CT, and 50% dose EID-CT relative to standard dose EID-CT were performed using Wilcoxon Rank test. RESULTS: 20 patients underwent standard dose EID-CT (~ CTDIvol, 4.5 mGy); 10 patients, standard dose PCD-CT (4.0 mGy); 10 patients, 50% PCD-CT (2.6 mGy). Standard dose EID-CT images were scored as adequate for diagnostic task in all categories (range 2.8-3.0). Standard dose PCD-CT images scored higher than the reference in all categories (range 3.5-4, p < 0.0033). Half-dose PCD-CT images also scored higher for noise and cortex visualization (p < 0.0033) and equivalent for artifacts and visualization of non-FAI pathology. Finally, simulated 50% EID-CT images scored lower in all categories (range 1.8-2.4, p < 0.0033). CONCLUSIONS: Dose-matched PCD-CT is superior to EID-CT for alpha angle and acetabular version measurement in the work up of FAI. UHR-PCD-CT enables 50% radiation dose reduction compared to EID while remaining adequate for the imaging task.


Assuntos
Impacto Femoroacetabular , Humanos , Impacto Femoroacetabular/diagnóstico por imagem , Estudos Prospectivos , Estudos de Viabilidade , Fótons , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Doses de Radiação
6.
J Appl Clin Med Phys ; 24(7): e14074, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37335819

RESUMO

PURPOSE: To determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon-counting-detector (PCD) CT system. METHODS: A daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra-high-resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low-energy-threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi-energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc. RESULTS: The daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc. CONCLUSION: Protocols and parameters must be properly selected on PCD-CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi-energy phantom scans are also recommended to comprehensively evaluate PCD-CT scanner performance.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Fótons , Protocolos Clínicos
7.
Radiology ; 303(1): 130-138, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34904876

RESUMO

Background The first clinical CT system to use photon-counting detector (PCD) technology has become available for patient care. Purpose To assess the technical performance of the PCD CT system with use of phantoms and representative participant examinations. Materials and Methods Institutional review board approval and written informed consent from four participants were obtained. Technical performance of a dual-source PCD CT system was measured for standard and high-spatial-resolution (HR) collimations. Noise power spectrum, modulation transfer function, section sensitivity profile, iodine CT number accuracy in virtual monoenergetic images (VMIs), and iodine concentration accuracy were measured. Four participants were enrolled (between May 2021 and August 2021) in this prospective study and scanned using similar or lower radiation doses as their respective clinical examinations performed on the same day using energy-integrating detector (EID) CT. Image quality and findings from the participants' PCD CT and EID CT examinations were compared. Results All standard technical performance measures met accreditation and regulatory requirements. Relative to filtered back-projection reconstructions, images from iterative reconstruction had lower noise magnitude but preserved noise power spectrum shape and peak frequency. Maximum in-plane spatial resolutions of 125 and 208 µm were measured for HR and standard PCD CT scans, respectively. Minimum values for section sensitivity profile full width at half maximum measurements were 0.34 mm (0.2-mm nominal section thickness) and 0.64 mm (0.4-mm nominal section thickness) for HR and standard PCD CT scans, respectively. In a 120-kV standard PCD CT scan of a 40-cm phantom, VMI iodine CT numbers had a mean percentage error of 5.7%, and iodine concentration had root mean squared error of 0.5 mg/cm3, similar to previously reported values for EID CT. VMIs, iodine maps, and virtual noncontrast images were created for a coronary CT angiogram acquired with 66-msec temporal resolution. Participant PCD CT images showed up to 47% lower noise and/or improved spatial resolution compared with EID CT. Conclusion Technical performance of clinical photon-counting detector (PCD) CT is improved relative to that of a current state-of-the-art CT system. The dual-source PCD geometry facilitated 66-msec temporal resolution multienergy cardiac imaging. Study participant images illustrated the effect of the improved technical performance. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Willemink and Grist in this issue.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Fótons , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
8.
AJR Am J Roentgenol ; 218(6): 1041-1050, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35080455

RESUMO

BACKGROUND. Dual-energy CT (DECT) allows noninvasive detection of monosodium urate (MSU) crystal deposits and has become incorporated into the routine clinical evaluation for gout at many institutions over the past decade. OBJECTIVE. The purpose of this study was to compare two time periods over the past decade in terms of radiologists' interpretations of DECT examinations performed for the evaluation of gout and subsequent clinical actions. METHODS. This retrospective study included 100 consecutive adult patients who underwent DECT to evaluate for gout in each of two periods (one beginning in March 2013 and one beginning in September 2019). Examinations performed in 2013 were conducted using a second-generation DECT scanner (80 kV [tube A] and 140 kV [tube B] with a 0.4-mm tin filter), and those performed in 2019 were conducted using a third-generation DECT scanner (80 kV [tube A] and 150 kV [tube B] with a 0.6-mm tin filter) that provides improved spectral separation. Original DECT reports were classified as positive, negative, or equivocal for MSU crystals indicative of gout. Joint aspirations occurring after the DECT examinations were recorded on the basis of findings from medical record review. A single radiologist performed a post hoc retrospective blinded image review, classifying examinations as positive, negative, or equivocal. RESULTS. In 2013, 44.0% of DECT examinations were interpreted as positive, 23.0% as negative, and 33.0% as equivocal; in 2019, 37.0% were interpreted as positive, 47.0% as negative, and 16.0% as equivocal (p < .001). The frequency of joint aspiration after DECT was 14.0% in 2013 versus 2.0% in 2019 (p = .002), and that after DECT examinations with negative interpretations was 17.4% in 2013 versus 2.1% in 2019 (p = .02). In post hoc assessment by a single radiologist, the distribution of interpretations in 2013 was positive in 49.0%, negative in 22.0%, and equivocal in 29.0%, and in 2019 it was positive in 39.0%, negative in 50.0%, and equivocal in 11.0% (p < .001). CONCLUSION. When DECT examinations performed for gout in 2013 and 2019 were compared, the frequency of equivocal interpretations was significantly lower in 2019, possibly in relation to interval technologic improvements. Negative examinations were less frequently followed by joint aspirations in 2019, possibly reflecting increasing clinical acceptance of the DECT results. CLINICAL IMPACT. The findings indicate an evolving role for DECT in the evaluation of gout after an institution's routine adoption of the technology for this purpose.


Assuntos
Gota , Ácido Úrico , Adulto , Gota/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Estanho , Tomografia Computadorizada por Raios X/métodos
9.
Catheter Cardiovasc Interv ; 97(4): E502-E509, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33016648

RESUMO

OBJECTIVES: The purpose of this study was to investigate the influence of simulated reduced-dose three-dimensional angiography (3DA) on the accuracy and precision of linear measurements derived from 3DA datasets. BACKGROUND: Three-dimensional angiography is performed during X-ray guided interventional procedures to aid diagnosis and inform treatment strategies for children and adults with congenital heart disease. However, 3DA contributes substantially to patient radiation dose and may lead to an increased radiation-induced cancer risk. METHODS: Reduced-dose patient 3DA images were simulated by adding quantum noise to the 2D projection angiograms, then reconstructing the projection angiograms into the 3DA dataset. Dose reduction in the range 33-72% was simulated. Five observers performed 46 vessel diameter measurements along prespecified axes within 23 vessel segments from 11 patient 3DA datasets. Statistical tests were performed to assess the influence of radiation dose reduction on the accuracy and precision of vessel diameter measurements. RESULTS: Vessel diameter measurements were in the range 5.9- 22.7 mm. Considering all vessel segments and observers, the influence of dose level on the accuracy of diameter measurements was in the range 0.02 - 0.15 mm (p .05-.8). Interobserver variability increased modestly with vessel diameter, but was not influence by dose level (p = .52). The statistical test for observer recall bias was negative (p = .51). CONCLUSIONS: Simulated dose reduction up to 72% did not affect the accuracy or precision of the diameter measurements acquired from 3DA images. These findings may embolden 3DA radiation dose reduction for pediatric and congenital heart disease patients.


Assuntos
Cardiologia , Redução da Medicação , Adulto , Angiografia Digital , Criança , Humanos , Imageamento Tridimensional , Resultado do Tratamento
10.
Emerg Radiol ; 28(4): 781-788, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33644833

RESUMO

PURPOSE: To evaluate the ability of a semi-automated radiomic analysis software in predicting the likelihood of spontaneous passage of urinary stones compared with manual measurements. METHODS: Symptomatic patients visiting the emergency department with suspected stones in either kidney or ureters who underwent a CT scan were included. Patients were followed for up to 6 months for the outcome of a trial of passage. Maximum stone diameters in axial and coronal images were measured manually. Stone length, width, height, max diameter, volume, the mean and standard deviation of the Hounsfield units, and morphologic features were also measured using automated radiomic analysis software. Multivariate models were developed using these data to predict subsequent spontaneous stone passage, with results expressed as the area under a receiver operating curve (AUC). RESULTS: One hundred eighty-four patients (69 females) with a median age of 56 years were included. Spontaneous stone passage occurred in 114 patients (62%). Univariate analysis demonstrated an AUC of 0.83 and 0.82 for the maximum stone diameter determined manually in the axial and coronal planes, respectively. Multivariate models demonstrated an AUC of 0.82 for a model including manual measurement of maximum stone diameter in axial and coronal planes. The same AUC was found for a model including automatic measurement of maximum height and diameter of the stone. Further addition of morphological parameters measured automatically did not increase AUC beyond 0.83. CONCLUSION: The semi-automated radiomic analysis of urinary stones shows similar accuracy compared with manual measurements for predicting urinary stone passage. Further studies are needed to predict clinical impacts of reporting the likelihood of urinary stone passage and improving inter-observer variation using automatic radiomic analysis software.


Assuntos
Ureter , Cálculos Ureterais , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Probabilidade , Tomografia Computadorizada por Raios X
11.
Radiology ; 289(2): 436-442, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30084728

RESUMO

Purpose To compare a research photon-counting-detector (PCD) CT scanner to a dual-source, dual-energy CT scanner for the detection and characterization of renal stones in human participants with known stones. Materials and Methods Thirty study participants (median age, 61 years; 10 women) underwent a clinical renal stone characterization scan by using dual-energy CT and a subsequent research PCD CT scan by using the same radiation dose (as represented by volumetric CT dose index). Two radiologists were tasked with detection of stones, which were later characterized as uric acid or non-uric acid by using a commercial dual-energy CT analysis package. Stone size and contrast-to-noise ratio were additionally calculated. McNemar odds ratios and Cohen k were calculated separately for all stones and small stones (≤3 mm). Results One-hundred sixty renal stones (91 stones that were ≤ 3 mm in axial length) were visually detected. Compared with 1-mm-thick routine images from dual-energy CT, the odds of detecting a stone at PCD CT were 1.29 (95% confidence interval: 0.48, 3.45) for all stones. Stone segmentation and characterization were successful at PCD CT in 70.0% (112 of 160) of stones versus 54.4% (87 of 160) at dual-energy CT, and was superior for stones 3 mm or smaller at PCD CT (45 vs 25 stones, respectively; P = .002). Stone characterization agreement between scanners for stones of all sizes was substantial (k = 0.65). Conclusion Photon-counting-detector CT is similar to dual-energy CT for helping to detect renal stones and is better able to help characterize small renal stones. © RSNA, 2018.


Assuntos
Cálculos Renais/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Fótons , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/instrumentação
12.
Foot Ankle Surg ; 24(4): 271-281, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29409240

RESUMO

BACKGROUND: The treatment of Morton's neuroma (MN) can be operative, conservative and infiltrative. Our aim was the evaluation of evidence on outcomes with different types of conservative, infiltrative and surgical treatment in patients affected by primary MN. METHODS: The bibliographic search was conducted in MEDLINE, Cochrane Library, DARE. Only studies in English were collected. The last search was in August 2015. Case series and randomized controlled trials (RCTs) assessing patients' satisfaction or pain improvement at an average follow-up of at least 6 months after treatment of primary MN were included. Two reviewers selected the studies, evaluated their methodological quality, and retrieved data independently. RESULTS: Of 283 titles found, only 29 met the inclusion criteria. Data showed better outcomes with operative treatment. CONCLUSIONS: The evaluated case series and few RCTs showed better results with invasive treatment. More and better RCTs which evaluate risk-benefit ratio are required to confirm these results.


Assuntos
Neuroma Intermetatársico/cirurgia , Humanos
13.
BMC Psychiatry ; 16: 253, 2016 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-27439471

RESUMO

BACKGROUND: Symptoms description is often not enough to provide clinicians with guidelines for treatments and patients' clinical history does not represent an exhaustive source of data. Psychopathological dysfunctions are known to relate to the core disturbances that underlie different forms of psychopathology so the identification of such dysfunctions could be helpful for treatments. Some tools are available although highly complex and lengthy. This study aimed to provide clinicians with an easy-to-administer instrument able to capture different levels of impairment in psychopathological functioning, namely the Psychopathological Functioning Levels - Rating Scale (PFL-RS). METHODS: The Psychopathological Functioning Level - Research and Training Committee (PFL-RTC) has been established in Turin since 2002 including psychiatrists and clinical psychologists with extensive clinical and research experience. Our research was grounded on the Qualitative Research Criteria (QRC) 1-7 and conducted with subsequent steps in order to identify those core psychopathological dysfunctions to be rated by this tool. RESULTS: From 2002 until 2014, 316 outpatients were administered the clinical interview on at least two different occasions. Diagnoses were mixed and included: Schizophrenic and Psychotic Disorders, Depressive Disorders, Anxiety Disorders, Obsessive-Compulsive Disorder, Post- Traumatic Stress Disorder, Somatic Symptoms Disorders, Eating Disorders and Personality Disorders. Focus groups were conducted to identify those psychopathological dysfunctions which needed to be rated, according to two Phenomenological Selection Criteria (PhSC) and four Etiopathogenetic Selection Criteria (EtSC). As a result, five dysfunctional areas emerged: Identity (ID); Comprehension (CO); Negative Emotions (NE); Action-Regulation (AR); Social Skills (SS). After checking such dimensions for consistency with the existing instruments, 7 levels of severity were identified for each area. Finally, a provisional Italian schedule of Psychopathological Functioning Levels - Rating Scale (PFL-RS) was obtained and checked for semantic comprehension and then administered gathering preliminary data. CONCLUSIONS: Psychopathological dysfunctions underlying mental disorders have been recognized in the present study with the PFL-RS. This instrument seems promising to inform in a specific way treatments strategies and goals, specifically concerning psychotherapy. Notwithstanding, further research is needed in order to confirm validity, sensitivity and reliability of this instrument.


Assuntos
Transtornos Mentais/diagnóstico , Psicopatologia , Adulto , Feminino , Grupos Focais , Humanos , Masculino , Escalas de Graduação Psiquiátrica , Psiquiatria , Psicoterapia , Pesquisa Qualitativa , Reprodutibilidade dos Testes , Adulto Jovem
14.
Phys Med Biol ; 69(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38688289

RESUMO

Objective. Conventional computed tomography (CT) imaging does not provide quantitative information on local thermal changes during percutaneous ablative therapy of cancerous and benign tumors, aside from few qualitative, visual cues. In this study, we have investigated changes in CT signal across a wide range of temperatures and two physical phases for two different tissue mimicking materials, each.Approach. A series of experiments were conducted using an anthropomorphic phantom filled with water-based gel and olive oil, respectively. Multiple, clinically used ablation devices were applied to locally cool or heat the phantom material and were arranged in a configuration that produced thermal changes in regions with inconsequential amounts of metal artifact. Eight fiber optic thermal sensors were positioned in the region absent of metal artifact and were used to record local temperatures throughout the experiments. A spectral CT scanner was used to periodically acquire and generate electron density weighted images. Average electron density weighted values in 1 mm3volumes of interest near the temperature sensors were computed and these data were then used to calculate thermal volumetric expansion coefficients for each material and phase.Main results. The experimentally determined expansion coefficients well-matched existing published values and variations with temperature-maximally differing by 5% of the known value. As a proof of concept, a CT-generated temperature map was produced during a heating time point of the water-based gel phantom, demonstrating the capability to map changes in electron density weighted signal to temperature.Significance. This study has demonstrated that spectral CT can be used to estimate local temperature changes for different materials and phases across temperature ranges produced by thermal ablations.


Assuntos
Técnicas de Ablação , Estudos de Viabilidade , Imagens de Fantasmas , Termometria , Tomografia Computadorizada por Raios X , Termometria/métodos , Técnicas de Ablação/métodos , Cirurgia Assistida por Computador/métodos , Temperatura , Humanos
15.
Polymers (Basel) ; 16(5)2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38475260

RESUMO

This study delves into the rheological and mechanical properties of a 3D-printable composite solid propellant with 80% wt solids loading. Polybutadiene is used as a binder with ammonium sulfate, which is added as an inert replacement for the ammonium perchlorate oxidizer. Further additives are introduced to allow for UV curing. An in-house illumination system made of four UV-A LEDs (385 nm) is employed to cure the resulting slurry. Rheological and mechanical tests are conducted to evaluate the viscosity, ultimate tensile strength and strain, and compression behavior. Viscosity tests are performed for both pure resin and complete propellant composition. A viscosity reduction factor is obtained for the tested formulations when pre-heating slurry. Uniaxial tensile and compression tests reveal that the mechanical properties are consistent with previous research. Results emphasize the critical role of temperature and solid loading percentage. Pre-heating resin composites may grant a proper viscosity reduction while keeping mechanical properties in the applicability range. Overall, these findings pave the way for the development of a 3D printer prototype for composite solid propellants.

16.
Radiol Case Rep ; 19(8): 3517-3521, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38881625

RESUMO

Dual-energy or spectral computed tomography (CT) information may be obtained by either sending X-ray beams of different energy spectra through the patient or by discriminating the energy of the X-rays that reach the detector. The spectral signal is then used to generate multiple results: conventional, virtual monoenergetic (MonoE), effective atomic number, electron density, and other material specific (e.g., iodine, calcium, or uric acid). This report demonstrates the potential benefits of spectral CT imaging during percutaneous tumor ablation procedures, specifically regarding visualization of inconspicuous tumors, accurate probe placement, and assessment of treatment efficacy.

17.
Phys Med Biol ; 69(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38648795

RESUMO

Objective. Photon-counting detector (PCD) CT enables routine virtual-monoenergetic image (VMI) reconstruction. We evaluated the performance of an automatic VMI energy level (keV) selection tool on a clinical PCD-CT system in comparison to an automatic tube potential (kV) selection tool from an energy-integrating-detector (EID) CT system from the same manufacturer.Approach.Four torso-shaped phantoms (20-50 cm width) containing iodine (2, 5, and 10 mg cc-1) and calcium (100 mg cc-1) were scanned on PCD-CT and EID-CT. Dose optimization techniques, task-based VMI energy level and tube-potential selection on PCD-CT (CARE keV) and task-based tube potential selection on EID-CT (CARE kV), were enabled. CT numbers, image noise, and dose-normalized contrast-to-noise ratio (CNRd) were compared.Main results. PCD-CT produced task-specific VMIs at 70, 65, 60, and 55 keV for non-contrast, bone, soft tissue with contrast, and vascular settings, respectively. A 120 kV tube potential was automatically selected on PCD-CT for all scans. In comparison, EID-CT used x-ray tube potentials from 80 to 150 kV based on imaging task and phantom size. PCD-CT achieved consistent dose reduction at 9%, 21% and 39% for bone, soft tissue with contrast, and vascular tasks relative to the non-contrast task, independent of phantom size. On EID-CT, dose reduction factor for contrast tasks relative to the non-contrast task ranged from a 65% decrease (vascular task, 70 kV, 20 cm phantom) to a 21% increase (soft tissue with contrast task, 150 kV, 50 cm phantom) due to size-specific tube potential adaptation. PCD-CT CNRdwas equivalent to or higher than those of EID-CT for all tasks and phantom sizes, except for the vascular task with 20 cm phantom, where 70 kV EID-CT CNRdoutperformed 55 keV PCD-CT images.Significance. PCD-CT produced more consistent CT numbers compared to EID-CT due to standardized VMI output, which greatly benefits standardization efforts and facilitates radiation dose reduction.


Assuntos
Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Fótons , Doses de Radiação , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Automação , Humanos , Razão Sinal-Ruído
18.
Personal Disord ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38573656

RESUMO

Mentalization, that is the capacity to understand our and others' behaviors in terms of intentional mental states, represents one of the core features of personality disorders (PDs) and can be related to therapists' countertransference (CT) and interventions. AIMS: The aim of the present work was to study the relationship between therapists' technique, therapists' CT, and patients' mentalization, in a sample of patients with PDs undergoing a 40-session program of sequential brief-adlerian psychodynamic psychotherapy, a psychodynamic therapeutic model specifically developed for the treatment of PDs in public mental health services. METHOD: Eighty-seven patients with PD and their therapists completed ratings of mentalization (mentalization imbalances scale and reflective functioning questionnaire), CT (therapist response questionnaire), and therapists' intervention (comparative psychotherapy process scale) at five different time points (Sessions 5, 10, 20, 30, and 40). RESULTS: Results showed that patients' mentalizing problematics decreased over time. Moreover, we found a reduction of therapists' disengaged CT, and an increase in positive CT over time. Regarding therapists' techniques, psychodynamic-interpersonal interventions were on average higher than cognitive-behavioral, but both techniques were used increasingly over time. Our results also showed significant and clinically coherent interactions between therapist's CT and techniques and between patient's mentalization imbalance and therapist's response. Our results highlighted the importance of early stages in therapy, since the most significant relationships between the various process variables (patient's mentalizing imbalances, therapist's techniques, and emotional responses) are observed between t1 and t2, corresponding to the initial phases of the treatments. Clinical implications will be discussed. (PsycInfo Database Record (c) 2024 APA, all rights reserved).

19.
Br J Radiol ; 97(1153): 93-97, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38263843

RESUMO

OBJECTIVES: To describe the feasibility and evaluate the performance of multiphasic photon-counting detector (PCD) CT for detecting breast cancer and nodal metastases with correlative dynamic breast MRI and digital mammography as the reference standard. METHODS: Adult females with biopsy-proven breast cancer undergoing staging breast MRI were prospectively recruited to undergo a multiphasic PCD-CT using a 3-phase protocol: a non-contrast ultra-high-resolution (UHR) scan and 2 intravenous contrast-enhanced scans with 50 and 180 s delay. Three breast radiologists compared CT characteristics of the index malignancy, regional lymphadenopathy, and extramammary findings to MRI. RESULTS: Thirteen patients underwent both an MRI and PCD-CT (mean age: 53 years, range: 36-75 years). Eleven of thirteen cases demonstrated suspicious mass or non-mass enhancement on PCD-CT when compared to MRI. All cases with metastatic lymphadenopathy (3/3 cases) demonstrated early avid enhancement similar to the index malignancy. All cases with multifocal or multicentric disease on MRI were also identified on PCD-CT (3/3 cases), including a 4 mm suspicious satellite lesion. Four of five patients with residual suspicious post-biopsy calcifications on mammograms were detected on the UHR PCD-CT scan. Owing to increased field-of-view at PCD-CT, a 5 mm thoracic vertebral metastasis was identified at PCD-CT and not with the breast MRI. CONCLUSIONS: A 3-phase PCD-CT scan protocol shows initial promising results in characterizing breast cancer and regional lymphadenopathy similar to MRI and detects microcalcifications in 80% of cases. ADVANCES IN KNOWLEDGE: UHR and spectral capabilities of PCD-CT may allow for comprehensive characterization of breast cancer and may represent an alternative to breast MRI in select cases.


Assuntos
Neoplasias da Mama , Calcinose , Linfadenopatia , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Mama , Linfonodos , Tomografia Computadorizada por Raios X
20.
J Virol ; 86(7): 3564-73, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22278240

RESUMO

We investigated the synergism between influenza virus and Streptococcus pneumoniae, particularly the role of deletions in the stalk region of the neuraminidase (NA) of H2N2 and H9N2 avian influenza viruses. Deletions in the NA stalk (ΔNA) had no effect on NA activity or on the adherence of S. pneumoniae to virus-infected human alveolar epithelial (A549) and mouse lung adenoma (LA-4) cells, although it delayed virus elution from turkey red blood cells. Sequential S. pneumoniae infection of mice previously inoculated with isogenic recombinant H2N2 and H9N2 influenza viruses displayed severe pneumonia, elevated levels of intrapulmonary proinflammatory responses, and death. No differences between the WT and ΔNA mutant viruses were detected with respect to effects on postinfluenza pneumococcal pneumonia as measured by bacterial growth, lung inflammation, morbidity, mortality, and cytokine/chemokine concentrations. Differences were observed, however, in influenza virus-infected mice that were treated with oseltamivir prior to a challenge with S. pneumoniae. Under these circumstances, mice infected with ΔNA viruses were associated with a better prognosis following a secondary bacterial challenge. These data suggest that the H2N2 and H9N2 subtypes of avian influenza A viruses can contribute to secondary bacterial pneumonia and deletions in the NA stalk may modulate its outcome in the context of antiviral therapy.


Assuntos
Deleção de Genes , Vírus da Influenza A Subtipo H2N2/enzimologia , Vírus da Influenza A Subtipo H9N2/enzimologia , Influenza Humana/virologia , Neuraminidase/genética , Pneumonia Bacteriana/microbiologia , Streptococcus pneumoniae/fisiologia , Proteínas Virais/genética , Motivos de Aminoácidos , Animais , Aderência Bacteriana , Linhagem Celular , Galinhas , Coinfecção/microbiologia , Coinfecção/virologia , Feminino , Humanos , Vírus da Influenza A Subtipo H2N2/química , Vírus da Influenza A Subtipo H2N2/genética , Vírus da Influenza A Subtipo H9N2/química , Vírus da Influenza A Subtipo H9N2/genética , Influenza Aviária/virologia , Influenza Humana/complicações , Pulmão/microbiologia , Pulmão/virologia , Camundongos , Camundongos Endogâmicos BALB C , Neuraminidase/química , Neuraminidase/metabolismo , Pneumonia Bacteriana/complicações , Proteínas Virais/química , Proteínas Virais/metabolismo