Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(3)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36772679

RESUMO

Sensor signals are physical, chemical, or biological quantities that evolve over time [...].

2.
Sensors (Basel) ; 23(16)2023 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-37631814

RESUMO

Rockfalls and landslide events are caused by different factors among which are included geomorphological and climatic factors and also human interaction. Therefore, the economic and social impacts can be significant and the remote monitoring of such hazards has become an essential topic in various applications. Wireless sensor networks (WSNs) are well suited for the deployment of monitoring systems, benefiting from the different technologies and topologies that are available and evolving nowadays. This review paper aims to summarize and overview the up-to-date state of the art of rockfall and landslide monitoring systems based on WSNs. The implementation and methods were analyzed for each solution, along with the system architecture and relevant hardware aspects. All the retrieved data were used to analyze the current trends and future possibilities in the field of WSN geohazard monitoring.

3.
Sensors (Basel) ; 23(6)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36991905

RESUMO

In this study, a review of second-generation voltage conveyor (VCII) and current conveyor (CCII) circuits for the conditioning of bio signals and sensors is presented. The CCII is the most known current-mode active block, able to overcome some of the limitations of the classical operational amplifier, which provides an output current instead of a voltage. The VCII is nothing more than the dual of the CCII, and for this reason it enjoys almost all the properties of the CCII but also provides an easy-to-read voltage as an output signal. A broad set of solutions for relevant sensors and biosensors employed in biomedical applications is considered. This ranges from the widespread resistive and capacitive electrochemical biosensors now used in glucose and cholesterol meters and in oximetry to more specific sensors such as ISFETs, SiPMs, and ultrasonic sensors, which are finding increasing applications. This paper also discusses the main benefits of this current-mode approach over the classical voltage-mode approach in the realization of readout circuits that can be used as electronic interfaces for different types of biosensors, including higher circuit simplicity, better low-noise and/or high-speed performance, and lower signal distortion and power consumption.


Assuntos
Técnicas Biossensoriais , Eletrônica
4.
Sensors (Basel) ; 22(9)2022 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-35591268

RESUMO

This study reviews second-generation voltage conveyor (VCII)-based read-out circuits for sensors and bioelectrical signal conditioning from existing literature. VCII is the dual circuit of a second-generation current conveyor (CCII), which provides the possibility of processing signals in the current domain while providing output signals in the voltage form. The scope of this paper is to discuss the benefits and opportunities of new VCII-based read-out circuits over traditional ones and bioelectrical signals. The achieved main benefits compared to conventional circuits are the simpler read-out circuits, producing an output signal in a voltage form that can be directly used, improved accuracy, possibility of gain adjustment using a single grounded resistor, and the possibility of connecting several SiPM sensors to the readout circuit. The circuits studied in this paper include VCII- based read-out circuits suitable for all types of sensors configured in the current-mode Wheatstone bridge (CMWB) topology, the VCII-based read-out circuits solutions reported for silicon photomultiplier, spiral-shaped ultrasonic PVDF and differential capacitive sensors, and, finally, a simple readout circuitry for sensing bioelectrical signals. There are still not many VCII-based readout circuits, and we hope that the outcome of this study will enhance this area of research and inspire new ideas.

5.
Sensors (Basel) ; 22(22)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36433281

RESUMO

It is necessary to ensure safety in terms of health and accidents through the real-time monitoring of the construction site environment and workers. This problem has become of great importance due to the economic and social implications. Therefore, a sensor-based approach has been found to be beneficial in Building Information Modeling (BIM). Wireless Sensor Network (WSN) technologies are well-suited for the deployment of monitoring systems. A suitable technical solution for node communication in a WSN is Long Range (LoRa) modulation technology. In this study, an autonomous LoRa-based system for the monitoring of a construction site in Lungro, Calabria, Italy, is presented. The spatial monitoring of working personnel is achieved by employing a tracker device with an Inertial Measurement Unit (IMU) and a Global Positioning System (GPS) device. Accesses of personnel and gear to the site are registered using Radio Frequency Identification (RFID) tags equipped with protective gear. Fixed-position solar-powered sensor nodes are also employed for structural monitoring, i.e., movement sensors are used to monitor the variation of scaffolding, building structures, and under-work housing inclinations. Long Range Wide Area Network (LoRaWAN) gateways interface with the nodes and the internet for data exchange, enabling an Internet of Things (IoT) paradigm for the monitoring solution. A comprehensive overview of the workers and structural nodes, along with the RFID access management system and LoRaWAN gateway features, is provided in this article. A description of the web interface is also reported.


Assuntos
Dispositivo de Identificação por Radiofrequência , Tecnologia sem Fio , Humanos , Monitorização Fisiológica , Tecnologia , Itália
6.
Sensors (Basel) ; 21(6)2021 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-33806723

RESUMO

Research on systems and circuits for interfacing sensors has always been, and will surely be, a highly prioritized, widespread, and lively topic [...].

7.
Sensors (Basel) ; 21(8)2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33920787

RESUMO

The use of wearable sensors for health monitoring is rapidly growing. Over the past decade, wearable technology has gained much attention from the tech industry for commercial reasons and the interest of researchers and clinicians for reasons related to its potential benefit on patients' health. Wearable devices use advanced and specialized sensors able to monitor not only activity parameters, such as heart rate or step count, but also physiological parameters, such as heart electrical activity or blood pressure. Electrocardiogram (ECG) monitoring is becoming one of the most attractive health-related features of modern smartwatches, and, because cardiovascular disease (CVD) is one of the leading causes of death globally, the use of a smartwatch to monitor patients could greatly impact the disease outcomes on health care systems. Commercial wearable devices are able to record just single-lead ECG using a couple of metallic contact dry electrodes. This kind of measurement can be used only for arrhythmia diagnosis. For the diagnosis of other cardiac disorders, additional ECG leads are required. In this study, we characterized an electronic interface to be used with multiple contactless capacitive electrodes in order to develop a wearable ECG device able to perform several lead measurements. We verified the ability of the electronic interface to amplify differential biopotentials and to reject common-mode signals produced by electromagnetic interference (EMI). We developed a portable device based on the studied electronic interface that represents a prototype system for further developments. We evaluated the performances of the developed device. The signal-to-noise ratio of the output signal is favorable, and all the features needed for a clinical evaluation (P waves, QRS complexes and T waves) are clearly readable.


Assuntos
Perna (Membro) , Dispositivos Eletrônicos Vestíveis , Arritmias Cardíacas , Eletrocardiografia , Eletrodos , Humanos
8.
Sensors (Basel) ; 20(17)2020 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-32877996

RESUMO

In the last decades, the applications of structural monitoring are moving toward the field of civil engineering and infrastructures. Nevertheless, if the structures have damages, it does not mean that they have a complete loss of functionality, but rather that the system is no longer in an optimal condition so that, if the damage increases, the structure can collapse. Structural Health Monitoring (SHM), a process for the identification of damage, periodically collects data from suitable sensors that allow to characterize the damage and establishes the health status of the structure. Therefore, this monitoring will provide information on the structure condition, mostly about its integrity, in a short time, and, for infrastructures and civil structures, it is necessary to assess performance and health status. The aim of this work is to design an Internet of Things (IoT) system for Structural Health Monitoring to find possible damages and to see how the structure behaves over time. For this purpose, a customized datalogger and nodes have been designed. The datalogger is able to acquire the data coming from the nodes through RS485 communication and synchronize acquisitions. Furthermore, it has an internal memory to allow for the post-processing of the collected data. The nodes are composed of a digital triaxial accelerometer, a general-purpose microcontroller, and an external memory for storage measures. The microcontroller communicates with an accelerometer, acquires values, and then saves them in the memory. The system has been characterized and the damage indicator has been evaluated on a testing structure. Experimental results show that the estimated damage indicator increases when the structure is perturbed. In the present work, the damage indicator increased by a maximum value of 24.65 when the structure is perturbed by a 2.5 mm engraving.

9.
Sensors (Basel) ; 19(16)2019 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-31416211

RESUMO

In this paper, a novel approach to implement a stray insensitive CMOS interface for differential capacitive sensors is presented. The proposed circuit employs, for the first time, second-generation voltage conveyors (VCIIs) and produces an output voltage proportional to differential capacitor changes. Using VCIIs as active devices inherently allows the circuit to process the signal in the current domain, and hence, to benefit from its intrinsic advantages, such as high speed and simple implementation, while still being able to natively interface with voltage mode signal processing stages at necessity. The insensitiveness to the effects of parasitic capacitances is achieved through a simple feedback loop. In addition, the proposed circuit shows a very simple and switch-free structure (which can be used for both linear and hyperbolic sensors), improving its accuracy. The readout circuit was designed in a standard 0.35 µm CMOS technology under a supply voltage of ±1.65 V. Before the integrated circuit fabrication, to produce tangible proof of the effectiveness of the proposed architecture, a discrete version of the circuit was also prototyped using AD844 and LF411 to implement a discrete VCII. The achieved measurement results are in good agreement with theory and simulations, showing a constant sensitivity up to 412 mV/pF, a maximum linearity error of 1.9%FS, and acknowledging a good behavior with low baseline capacitive sensors (10 pF in the proposed measurements). A final table is also given to summarize the key specs of the proposed work comparing them to the available literature.

10.
Sensors (Basel) ; 17(11)2017 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-29143768

RESUMO

The aim of this work is the development of a contactless capacitive sensory system for the detection of (Electrocardiographic) ECG-like signals. The acquisition approach is based on a capacitive coupling with the patient body performed by electrodes integrated in a front-end circuit. The proposed system is able to detect changes in the electric charge related to the heart activity. Due to the target signal weakness and to the presence of other undesired signals, suitable amplification stages and analogue filters are required. Simulated results allowed us to evaluate the effectiveness of the approach, whereas experimental measurements, recorded without contact to the skin, have validated the practical effectiveness of the proposed architecture. The system operates with a supply voltage of ±9 V with an overall power consumption of about 10 mW. The analogue output of the electronic interface is connected to an ATmega328 microcontroller implementing the A/D conversion and the data acquisition. The collected data can be displayed on any multimedia support for real-time tracking applications.


Assuntos
Eletrocardiografia , Eletrodos , Desenho de Equipamento , Humanos , Processamento de Sinais Assistido por Computador
11.
Micromachines (Basel) ; 13(9)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36144063

RESUMO

The need for accurate information and the availability of novel tool and technological advances in agriculture have given rise to innovative autonomous systems. The aim is to monitor key parameters for optimal water and fertilizer management. A key issue in precision agriculture is the in situ monitoring of soil macronutrients. Here, a proof-of-concept study was conducted that tested two types of sensors capable of capturing both the electrochemical response of the soil and the electrical potential generated by the interaction between the soil and plants. These two sensors can be used to monitor large areas using a network approach, due to their small size and low power consumption. The voltammetric sensor (BIONOTE-L) proved to be able to characterize different soil samples. It was able, indeed, to provide a reproducible voltammetric fingerprint specific for each soil type, and to monitor the concentration of CaCl2 and NaCl in the soil. BIONOTE-L can be coupled to a device capable of capturing the energy produced by interactions between plants and soil. As a consequence, the functionality of the microsystem node when applied in a large-area monitoring network can be extended. Additional calibrations will be performed to fully characterize the instrument node, to implement the network, and to specialize it for a particular application in the field.

12.
Micromachines (Basel) ; 12(2)2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33498360

RESUMO

Exploiting the transmission and reception of low frequency ultrasounds in air is often associated with the innate echolocating abilities of some mammals, later emulated with sophisticated electronic systems, to obtain information about unstructured environments. Here, we present a novel approach for the reception of ultrasounds in air, which exploits a piezopolymer broadband sensor and an electronic interface based on a second-generation voltage conveyor (VCII). Taking advantage of its capability to manipulate both voltage and current signals, in this paper, we propose an extremely simple interface that presents a sensitivity level of about -100 dB, which is in line with commercially available references. The presented results are obtained without any filtration stage. The second-generation voltage conveyor active device is implemented through a commercially available AD844, with a supply voltage of ±15 V.

13.
Micromachines (Basel) ; 9(10)2018 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-30424460

RESUMO

Recent advances in sensing technologies, especially those for Microsensor Integrated Systems, have led to several new commercial applications. [...].

14.
Micromachines (Basel) ; 9(7)2018 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-30424276

RESUMO

The study of ladder networks made by sequences of directly coupled inductor⁻capacitor single cells has led us to discover a new property, which may be of certain interest in the sensor field. In the case of n cells, the n-frequencies vector characterizing each node may allow for the identification of that capacitor (sensor), which has experienced a variation of its nominal value. This localization is possible independently from the observable node of the ladder network as proven by the application of the following multivariate data analysis techniques: principal component analysis and partial least square discriminant analysis. This property can be applied on a large scale down to micrometric dimensions in agreement with the technologic ability to shrink the capacitive sensor dimensions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA