Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 96(15): 5940-5950, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38562013

RESUMO

Peptide-based supramolecules exhibit great potential in various fields due to their improved target recognition ability and versatile functions. However, they still suffer from numerous challenges for the biopharmaceutical analysis, including poor self-assembly ability, undesirable ligand-antibody binding rates, and formidable target binding barriers caused by ligand crowding. To tackle these issues, a "polyvalent recognition" strategy employing the CD20 mimotope peptide derivative NBD-FFVLR-GS-WPRWLEN (acting on the CDR domains of rituximab) was proposed to develop supramolecular nanofibers for target antibody recognition. These nanofibers exhibited rapid self-assembly within only 1 min and robust stability. Their binding affinity (179 nM) for rituximab surpassed that of the monomeric peptide (7 µM) by over 38-fold, highlighting that high ligand density and potential polyvalent recognition can efficiently overcome the target binding barriers of traditional supramolecules. Moreover, these nanofibers exhibited an amazing "instantaneous capture" rate (within 15 s), a high recovery (93 ± 3%), and good specificity for the target antibody. High-efficiency enrichment of rituximab was achieved from cell culture medium with good recovery and reproducibility. Intriguingly, these peptide nanofibers combined with bottom-up proteomics were successful in tracking the deamidation of asparagine 55 (from 10 to 16%) on the rituximab heavy chain after 21 day incubation in human serum. In summary, this study may open up an avenue for the development of versatile mimotope peptide supramolecules for biorecognition and bioanalysis of biopharmaceuticals.


Assuntos
Produtos Biológicos , Nanofibras , Humanos , Rituximab , Nanofibras/química , Ligantes , Reprodutibilidade dos Testes , Peptídeos/química
2.
J Chem Inf Model ; 64(19): 7447-7456, 2024 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-39284310

RESUMO

QSRR is a valuable technique for the retention time predictions of small molecules. This aims to bridge the gap between molecular structure and chromatographic behavior, offering invaluable insights for analytical chemistry. Given the challenge of simultaneous target prediction with variable experimental conditions and the scarcity of comprehensive data sets for such predictive modelings in chromatography, this study introduces a transfer learning-based multitarget QSRR approach to enhance retention time prediction. Through a comparative study of four models, both with and without the transfer learning approach, the performance of both single and multitarget QSRR was evaluated based on Mean Squared Error (MSE) and R2 metrics. Individual models were also tested for their performance against benchmark studies in this field. The findings suggest that transfer learning based multitarget models exhibit potential for enhanced accuracy in predicting retention times of small molecules, presenting a promising avenue for QSRR modeling. These models will be highly beneficial for optimizing experimental conditions in method development by better retention time predictions in Reversed-Phase Liquid Chromatography (RPLC). The reliable and effective predictive capabilities of these models make them valuable tools for pharmaceutical research and development endeavors.


Assuntos
Cromatografia de Fase Reversa , Relação Quantitativa Estrutura-Atividade , Aprendizado de Máquina
3.
Int J Mol Sci ; 24(11)2023 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-37298669

RESUMO

Estetrol (E4) is a natural estrogen with promising therapeutic applications in humans. The European Medicines Agency and the Food and Drug Administration have approved the use of 15 mg E4/3 mg drospirenone for contraceptive indication. Phase III clinical trials with 15-20 mg E4 for the relief of climacteric complaints are currently running. Relevant data from preclinical animal models are needed to characterize the molecular mechanisms and the pharmacological effects of E4 and possibly to reveal new therapeutic applications and to anticipate potential adverse effects. Therefore, it is important to design experimental procedures in rodents that closely mimic or anticipate human E4 exposure. In this study, we compared the effects of E4 exposure after acute or chronic administration in women and mice. Women who received chronic E4 treatment per os at a dose of 15 mg once daily reached a steady state within 6 to 8 days, with a mean plasma concentration of 3.20 ng/mL. Importantly, with subcutaneous, intraperitoneal or oral administration of E4 in mice, a stable concentration over time that would mimic human pharmacokinetics could not be achieved. The use of osmotic minipumps continuously releasing E4 for several weeks provided an exposure profile mimicking chronic oral administration in women. Measurements of the circulating concentration of E4 in mice revealed that the mouse equivalent dose necessary to mimic human treatment does not fit with the allometric prediction. In conclusion, this study highlights the importance of precise definition of the most appropriate dose and route of administration to utilize when developing predictive preclinical animal models to mimic or anticipate specific human treatment.


Assuntos
Estetrol , Estados Unidos , Humanos , Feminino , Camundongos , Animais , Estetrol/efeitos adversos , Estrogênios
4.
Molecules ; 28(4)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36838689

RESUMO

Reversed-Phase Liquid Chromatography (RPLC) is a common liquid chromatographic mode used for the control of pharmaceutical compounds during their drug life cycle. Nevertheless, determining the optimal chromatographic conditions that enable this separation is time consuming and requires a lot of lab work. Quantitative Structure Retention Relationship models (QSRR) are helpful for doing this job with minimal time and cost expenditures by predicting retention times of known compounds without performing experiments. In the current work, several QSRR models were built and compared for their adequacy in predicting the retention times. The regression models were based on a combination of linear and non-linear algorithms such as Multiple Linear Regression, Support Vector Regression, Least Absolute Shrinkage and Selection Operator, Random Forest, and Gradient Boosted Regression. Models were built for five pH conditions, i.e., at pH 2.7, 3.5, 6.5, and 8.0. In the end, the model predictions were combined using stacking and the performances of all models were compared. The k-nearest neighbor-based application domain filter was established to assess the reliability of the prediction for further compound prioritization. Altogether, this study can be insightful for analytical chemists working with RPLC to begin with the computational prediction modeling such as QSRR to predict the separation of small molecules.


Assuntos
Cromatografia de Fase Reversa , Relação Quantitativa Estrutura-Atividade , Reprodutibilidade dos Testes , Cromatografia Líquida/métodos , Algoritmos , Cromatografia Líquida de Alta Pressão/métodos
5.
Clin Chem ; 68(11): 1399-1409, 2022 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-36056745

RESUMO

BACKGROUND: Parathyroid hormone (PTH) measurement is important for patients with disorders of calcium metabolism, including those needing bone-turnover monitoring due to chronic kidney disease-mineral bone disorder. There are currently 2 generations of PTH immunoassays on the market, both having cross-reactivity issues and lacking standardization. Therefore, we developed an LC-MS/MS higher-order method for PTH analysis. METHODS: The method was calibrated against the international standard for 1-84 PTH (WHO 95/646). Antibody-free sample preparation with the addition of an isotope-labeled internal standard was performed by solid-phase extraction. Extracts were analyzed by LC-MS/MS. EDTA-K2 plasma was used throughout the development and validation. Bias and uncertainty sources were tested according to ISO 15193. Clinical Laboratory Standards Institute guidelines and reference measurement procedures were consulted for the design of the validation. Patient samples and external quality controls were compared between LC-MS/MS and 2 third-generation immunoassays. RESULTS: The method was validated for 1-84 PTH from 5.7 to 872.6 pg/mL. The interassay imprecision was between 1.2% and 3.9%, and the accuracy ranged from 96.2% to 103.2%. The measurement uncertainty was <5.6%. The comparison between LC-MS/MS and the immunoassays showed a proportional bias but moderate to substantial correlation between methods. CONCLUSIONS: This LC-MS/MS method, which is independent of antibodies, is suitable for a wide range of PTH concentrations. The obtained analytical performance specifications demonstrate that development of a reference measurement procedure will be possible once a higher order reference standard is available.


Assuntos
Hormônio Paratireóideo , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Extração em Fase Sólida , Padrões de Referência , Reprodutibilidade dos Testes
6.
Int J Mol Sci ; 23(14)2022 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-35886845

RESUMO

Proteomics is one of the most significant methodologies to better understand the molecular pathways involved in diseases and to improve their diagnosis, treatment and follow-up. The investigation of the proteome of complex organisms is challenging from an analytical point of view, because of the large number of proteins present in a wide range of concentrations. In this study, nanofluidic chromatography, using a micropillar array column, was coupled to drift-tube ion mobility and time-of-flight mass spectrometry to identify as many proteins as possible in a protein digest standard of HeLa cells. Several chromatographic parameters were optimized. The high interest of drift-tube ion mobility to increase the number of identifications and to separate isobaric coeluting peptides was demonstrated. Multiplexed drift-tube ion mobility spectrometry was also investigated, to increase the sensitivity in proteomics studies. This innovative proteomics platform will be useful for analyzing patient samples to better understand unresolved disorders.


Assuntos
Espectrometria de Mobilidade Iônica , Proteômica , Células HeLa , Humanos , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Massas/métodos , Proteoma , Proteômica/métodos
7.
Int J Mol Sci ; 23(21)2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36362139

RESUMO

The discovery of new antigens specific to multiple myeloma that could be targeted by novel immunotherapeutic approaches is currently of great interest. To this end, it is important to increase the number of proteins identified in the sample by combining different separation strategies. A capillary zone electrophoresis (CZE) method, coupled with drift tube ion mobility (DTIMS) and quadrupole time-of-flight mass spectrometry (QTOF), was developed for antigen discovery using the human myeloma cell line LP-1. This method was first optimized to obtain a maximum number of identifications. Then, its performance in terms of uniqueness of identifications was compared to data acquired by a microfluidic reverse phase liquid chromatography (RPLC) method. The orthogonality of these two approaches and the physicochemical properties of the entities identified by CZE and RPLC were evaluated. In addition, the contribution of DTIMS to CZE was investigated in terms of orthogonality as well as the ability to provide unique information. In conclusion, we believe that the combination of CZE-DTIMS-QTOF and microfluidic RPLC provides unique information in the context of antigen discovery.


Assuntos
Cromatografia de Fase Reversa , Mieloma Múltiplo , Humanos , Espectrometria de Massas em Tandem/métodos , Microfluídica , Linhagem Celular Tumoral , Eletroforese Capilar/métodos
8.
Molecules ; 27(23)2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36500399

RESUMO

In the pharmaceutical field, and more precisely in quality control laboratories, robust liquid chromatographic methods are needed to separate and analyze mixtures of compounds. The development of such chromatographic methods for new mixtures can result in a long and tedious process even while using the design of experiments methodology. However, developments could be accelerated with the help of in silico screening. In this work, the usefulness of a strategy combining response surface methodology (RSM) followed by multicriteria decision analysis (MCDA) applied to predictions from a quantitative structure-retention relationship (QSRR) model is demonstrated. The developed strategy shows that selecting equations for the retention time prediction models based on the pKa of the compound allows flexibility in the models. The MCDA developed is shown to help to make decisions on different criteria while being robust to the user's decision on the weights for each criterion. This strategy is proposed for the screening phase of the method lifecycle. The strategy offers the possibility to the user to select chromatographic conditions based on multiple criteria without being too sensitive to the importance given to them. The conditions with the highest desirability are defined as the starting point for further optimization steps.


Assuntos
Cromatografia de Fase Reversa , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida , Preparações Farmacêuticas
9.
Am J Physiol Endocrinol Metab ; 320(1): E19-E29, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33135461

RESUMO

Estetrol (E4), a natural estrogen synthesized by the human fetal liver, is currently evaluated in phase III clinical studies as a new menopause hormone therapy. Indeed, E4 significantly improves vasomotor and genito-urinary menopausal symptoms and prevents bone demineralization. Compared with other estrogens, E4 was found to have limited effects on coagulation factors in the liver of women allowing to expect less thrombotic events. To fully delineate its clinical potential, the aim of this study was to assess the effect of E4 on metabolic disorders. Here, we studied the pathophysiological consequences of a Western diet (42% kcal fat, 0.2% cholesterol) in ovariectomized female mice under chronic E4 treatment. We showed that E4 reduces body weight gain and improves glucose tolerance in both C57Bl/6 and LDLR-/- mice. To evaluate the role of hepatic estrogen receptor (ER) α in the preventive effect of E4 against obesity and associated disorders such as atherosclerosis and steatosis, mice harboring a hepatocyte-specific ERα deletion (LERKO) were crossed with LDLR-/- mice. Our results demonstrated that, whereas liver ERα is dispensable for the E4 beneficial actions on obesity and atheroma, it is necessary to prevent steatosis in mice. Overall, these findings suggest that E4 could prevent metabolic, hepatic, and vascular disorders occurring at menopause, extending the potential medical interest of this natural estrogen as a new hormonal treatment.NEW & NOTEWORTHY Estetrol prevents obesity, steatosis, and atherosclerosis in mice fed a Western diet. Hepatic ERα is necessary for the prevention of steatosis, but not of obesity and atherosclerosis.


Assuntos
Dieta Ocidental/efeitos adversos , Estetrol/uso terapêutico , Receptor alfa de Estrogênio/genética , Fígado/metabolismo , Obesidade/prevenção & controle , Placa Aterosclerótica/prevenção & controle , Tecido Adiposo/patologia , Animais , Estetrol/administração & dosagem , Feminino , Teste de Tolerância a Glucose , Hepatócitos/metabolismo , Lipídeos/sangue , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Obesidade/patologia , Ovariectomia , Placa Aterosclerótica/patologia , Receptores de LDL/genética
10.
Anal Chem ; 93(44): 14802-14809, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34694784

RESUMO

Fragment-based lead discovery is a usual strategy in drug discovery to identify innovative lead compounds. The success of this approach strongly relies on the capacity to detect weak binders and characterize their binding site. NMR and X-ray crystallography are the conventional technologies used to tackle this challenge. However, their large protein consumption and the cost of equipment reduce their accessibility. Here, an affinity capillary electrophoresis methodology was developed that enables the detection of mM binders, the determination of dissociation constants, and the characterization of the fragment binding site. On the basis of multiple equilibrium theory, dissociation constants in the µM-mM range were determined, and a new methodology is proposed to establish graphically if two fragments bind the same protein pocket. The applicability of this methodology was demonstrated experimentally on coagulation factor XIIa by evaluating pairs of fragments with expected behavior. This study reinforces the significance of using affinity capillary electrophoresis to gather valuable information for medicinal chemistry projects.


Assuntos
Descoberta de Drogas , Fator XIIa , Sítios de Ligação , Cristalografia por Raios X , Eletroforese Capilar , Ligação Proteica
11.
Electrophoresis ; 42(9-10): 1127-1134, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33482013

RESUMO

Synthetic cathinones are phenylalkylamine compounds related to natural cathinone from Catha edulis leaves. Due to their sympathomimetic effects comparable to common illicit drugs, these substances are mainly drugs of abuse and constitute the second most frequently seized group of new psychoactive substances. In order to ensure their regulation and to promote public health, reliable analytical tools are required to track these substances. In the present study, we developed a CE hyphenated to laser-induced fluorescence detection method to demonstrate its suitability to perform fast and cost-effective synthetic cathinones analysis. Fourteen compounds including isobaric compounds and position isomers were selected to encompass the large panel of chemical structures. To separate the FITC-labeled analytes (presenting the same negative charge and close mass to charge ratios), MEKC separation mode was selected. Method selectivity was not suitable using common surfactants. In this context, alkyl polyethylene glycol ether surfactants were successfully used as neutral surfactant to overcome this analytical challenge. The effect of surfactant nature on separation performances and migration behaviors of the analytes was also studied. Optimal BGE composition included 75 mM borate buffer at pH 9.3 and 0.4 mM of C12E10 surfactant. Final MEKC separation conditions were proposed to analyze a large panel of synthetic cathinones. This method helped to reach a sensitivity with LOD from 0.1 to 0.4 nM (pg/mL order).


Assuntos
Alcaloides/análise , Cromatografia Capilar Eletrocinética Micelar , Drogas Ilícitas , Tensoativos
12.
Horm Behav ; 134: 105024, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34256221

RESUMO

Enduring sex differences in the brain are established during a developmental process known as brain sexual differentiation and are mainly driven by estrogens during a critical period. In rodents, the masculinization of the preoptic area by estrogens derived from the central aromatization of testosterone depends in part on the interaction between microglia and prostaglandin E2 (PGE2), a pro-inflammatory hormone of the prostanoid subclass. In contrast, in birds, estrogens produced by females induce a demasculinization, but whether an interaction with the neuro-immune system is involved in this process is unknown. This study addressed this question by testing the effects of blockade of cyclo­oxygenases (COX), the rate-limiting enzymes for prostanoid synthesis, on embryonic microglia and the sexual differentiation of brain and behavior using the Japanese quail as an animal model. The results show that COX inhibition does not affect the behavior of females, but impairs male sexual behavior and suppresses the sex difference in microglial profiles at embryonic day 12 (E12) in the medial preoptic nucleus by increasing the number of microglia in males only. However, neither prostanoid concentrations nor PGE2 receptors differed between sexes in the hypothalamus and preoptic area (HPOA) during development. Overall, these results uncovered a potential role of prostanoids in the demasculinization of Japanese quail. Moreover, the parallel effect of COX inhibition on behavior and microglia suggests an interaction between prostanoids and microglia in brain demasculinization, thus fueling the hypothesis of a conserved role of the neuroimmune system in the organization of the brain by estrogens.


Assuntos
Coturnix , Diferenciação Sexual , Animais , Encéfalo , Feminino , Masculino , Microglia , Prostaglandina-Endoperóxido Sintases , Comportamento Sexual Animal
13.
Am J Hematol ; 96(10): 1275-1286, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34310730

RESUMO

Hematopoietic cell transplantation (HCT) brings important alterations in erythropoiesis and iron metabolism. Hepcidin, which regulates iron metabolism, increases in iron overload or inflammation and decreases with iron deficiency or activated erythropoiesis. Erythroferrone (ERFE) is the erythroid regulator of hepcidin. We investigated erythropoiesis and iron metabolism after allogeneic HCT in 70 patients randomized between erythropoietin (EPO) treatment or no EPO, by serially measuring hepcidin, ERFE, CRP (inflammation), soluble transferrin receptor (sTfR, erythropoiesis), serum iron and transferrin saturation (Tsat; iron for erythropoiesis) and ferritin (iron stores). We identified biological and clinical factors associated with serum hepcidin and ERFE levels. Serum ERFE correlated overall with sTfR and reticulocytes and inversely with hepcidin. Erythroferrone paralleled sTfR levels, dropping during conditioning and recovering with engraftment. Inversely, hepcidin peaked after conditioning and decreased during engraftment. Erythroferrone and hepcidin were not significantly different with or without EPO. Multivariate analyses showed that the major determinant of ERFE was erythropoiesis (sTfR, reticulocytes or serum Epo). Pretransplant hepcidin was associated with previous RBC transfusions and ferritin. After transplantation, the major determinants of hepcidin were iron status (ferritin at all time points and Tsat at day 56) and erythropoiesis (sTfR or reticulocytes or ERFE), while the impact of inflammation was less clear and clinical parameters had no detectable influence. Hepcidin remained significantly higher in patients with high compared to low pretransplant ferritin. After allogeneic HCT with or without EPO therapy, significant alterations of hepcidin occur between pretransplant and day 180, in correlation with iron status and inversely with erythroid ERFE.


Assuntos
Eritropoese , Transplante de Células-Tronco Hematopoéticas , Hepcidinas/metabolismo , Ferro/metabolismo , Hormônios Peptídicos/metabolismo , Adulto , Idoso , Eritropoese/efeitos dos fármacos , Eritropoetina/uso terapêutico , Feminino , Hepcidinas/sangue , Humanos , Ferro/sangue , Masculino , Pessoa de Meia-Idade , Hormônios Peptídicos/sangue , Transplante Homólogo
14.
Anal Chem ; 92(20): 14103-14112, 2020 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-32961048

RESUMO

Capillary zone electrophoresis-mass spectrometry (CE-MS) is a mature analytical tool for the efficient profiling of (highly) polar and ionizable compounds. However, the use of CE-MS in comparison to other separation techniques remains underrepresented in metabolomics, as this analytical approach is still perceived as technically challenging and less reproducible, notably for migration time. The latter is key for a reliable comparison of metabolic profiles and for unknown biomarker identification that is complementary to high resolution MS/MS. In this work, we present the results of a Metabo-ring trial involving 16 CE-MS platforms among 13 different laboratories spanning two continents. The goal was to assess the reproducibility and identification capability of CE-MS by employing effective electrophoretic mobility (µeff) as the key parameter in comparison to the relative migration time (RMT) approach. For this purpose, a representative cationic metabolite mixture in water, pretreated human plasma, and urine samples spiked with the same metabolite mixture were used and distributed for analysis by all laboratories. The µeff was determined for all metabolites spiked into each sample. The background electrolyte (BGE) was prepared and employed by each participating lab following the same protocol. All other parameters (capillary, interface, injection volume, voltage ramp, temperature, capillary conditioning, and rinsing procedure, etc.) were left to the discretion of the contributing laboratories. The results revealed that the reproducibility of the µeff for 20 out of the 21 model compounds was below 3.1% vs 10.9% for RMT, regardless of the huge heterogeneity in experimental conditions and platforms across the 13 laboratories. Overall, this Metabo-ring trial demonstrated that CE-MS is a viable and reproducible approach for metabolomics.


Assuntos
Eletroforese Capilar/métodos , Compostos Orgânicos/sangue , Compostos Orgânicos/urina , Espectrometria de Massas em Tandem/métodos , Cátions/química , Bases de Dados de Compostos Químicos , Eletrólitos/química , Humanos , Metaboloma , Metabolômica , Reprodutibilidade dos Testes
15.
Clin Chem Lab Med ; 59(2): 315-323, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33001847

RESUMO

Objectives: Hepcidin measurement advances insights in pathophysiology, diagnosis, and treatment of iron disorders, but requires analytically sound and standardized measurement procedures (MPs). Recent development of a two-level secondary reference material (sRM) for hepcidin assays allows worldwide standardization. However, no proficiency testing (PT) schemes to ensure external quality assurance (EQA) exist and the absence of a high calibrator in the sRM set precludes optimal standardization. Methods: We developed a pilot PT together with the Dutch EQA organization Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek (SKML) that included 16 international hepcidin MPs. The design included 12 human serum samples that allowed us to evaluate accuracy, linearity, precision and standardization potential. We manufactured, value-assigned, and validated a high-level calibrator in a similar manner to the existing low- and middle-level sRM. Results: The pilot PT confirmed logistical feasibility of an annual scheme. Most MPs demonstrated linearity (R2>0.99) and precision (duplicate CV>12.2%), although the need for EQA was shown by large variability in accuracy. The high-level calibrator proved effective, reducing the inter-assay CV from 42.0% (unstandardized) to 14.0%, compared to 17.6% with the two-leveled set. The calibrator passed international homogeneity criteria and was assigned a value of 9.07±0.24 nmol/L. Conclusions: We established a framework for future PT to enable laboratory accreditation, which is essential to ensure quality of hepcidin measurement and its use in patient care. Additionally, we showed optimized standardization is possible by extending the current sRM with a third high calibrator, although international implementation of the sRM is a prerequisite for its success.


Assuntos
Hepcidinas/sangue , Acreditação , Coleta de Amostras Sanguíneas , Calibragem , Cromatografia Líquida de Alta Pressão , Ensaio de Imunoadsorção Enzimática , Humanos , Laboratórios/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Controle de Qualidade , Padrões de Referência , Espectrometria de Massas em Tandem
16.
Int J Mol Sci ; 21(11)2020 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-32503311

RESUMO

Several clinical reports indicate that the use of amphetaminic anorectic drugs or ergot derivatives could cause valvular heart disease (VHD). We sought to investigate whether valvular lesions develop in response to long-term oral administration of these drugs and to identify drug-targeted biological processes that may lead to VHD. Treatment of New Zealand White rabbits with pergolide, dexfenfluramine, or high-dose serotonin for 16 weeks induced valvular alterations characterized by extracellular matrix remodeling. Transcriptome profiling of tricuspid valves using RNA sequencing revealed distinct patterns of differentially expressed genes (DEGs) that clustered according to the different treatments. Genes that were affected by the three treatments were functionally enriched for reduced cell metabolism processes. The two drugs yielded more changes in gene expression than serotonin and shared most of the DEGs. These DEGs were mostly enriched for decreased biosynthetic processes, increased cell-matrix interaction, and cell response to growth factors, including TGF-ß, which was associated with p38 MAPK activation. Treatment with pergolide specifically affected genes involved in homeostasis, which was corroborated by the activation of the master regulator of cell energy homeostasis, AMPK-α, as well as decreased levels of metabolism-related miR-107. Thus, both pergolide and dexfenfluramine may cause VHD through valve metabolic reprogramming and matrix remodeling.


Assuntos
Dexfenfluramina/efeitos adversos , Matriz Extracelular/efeitos dos fármacos , Regulação da Expressão Gênica/efeitos dos fármacos , Doenças das Valvas Cardíacas/induzido quimicamente , Pergolida/efeitos adversos , Valva Tricúspide/efeitos dos fármacos , Proteínas Quinases Ativadas por AMP/metabolismo , Administração Oral , Animais , Proliferação de Células , Análise por Conglomerados , Ativação Enzimática , Feminino , Doenças das Valvas Cardíacas/metabolismo , Doenças das Valvas Cardíacas/patologia , Homeostase , MicroRNAs/genética , Coelhos , Análise de Sequência de RNA , Serotonina/efeitos adversos , Transcriptoma , Fator de Crescimento Transformador beta/metabolismo , Valva Tricúspide/metabolismo , Proteínas Quinases p38 Ativadas por Mitógeno/metabolismo
17.
BMC Biotechnol ; 19(1): 81, 2019 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-31752839

RESUMO

BACKGROUND: Virus-like particle (VLP) platform represents a promising approach for the generation of efficient and immunogenic subunit vaccines. Here, the feasibility of using grapevine fanleaf virus (GFLV) VLPs as a new carrier for the presentation of human papillomavirus (HPV) L2 epitope was studied. To achieve this goal, a model of the HPV L2 epitope secondary structure was predicted and its insertion within 5 external loops in the GFLV capsid protein (CP) was evaluated. RESULTS: The epitope sequence was genetically inserted in the αB-αB" domain C of the GFLV CP, which was then over-expressed in Pichia pastoris and Escherichia coli. The highest expression yield was obtained in E. coli. Using this system, VLP formation requires a denaturation-refolding step, whereas VLPs with lower production yield were directly formed using P. pastoris, as confirmed by electron microscopy and immunostaining electron microscopy. Since the GFLV L2 VLPs were found to interact with the HPV L2 antibody under native conditions in capillary electrophoresis and in ELISA, it can be assumed that the inserted epitope is located at the VLP surface with its proper ternary structure. CONCLUSIONS: The results demonstrate that GFLV VLPs constitute a potential scaffold for surface display of the epitope of interest.


Assuntos
Proteínas do Capsídeo/imunologia , Epitopos/imunologia , Ensaio de Imunoadsorção Enzimática , Escherichia coli/virologia , Humanos , Microscopia Eletrônica , Nepovirus/imunologia , Nepovirus/patogenicidade , Papillomaviridae/imunologia , Papillomaviridae/patogenicidade , Dobramento de Proteína
18.
Electrophoresis ; 40(11): 1550-1557, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30815902

RESUMO

Parathyroid hormone (PTH) is a common clinical marker whose quantification relies on immunoassays, giving variable results as batch, brand, or target epitope changes. Sheathless CE-ESI-MS, combining CE resolution power and low-flow ESI sensitivity, was applied to the analysis of PTH in its native conformation in the presence of related forms. Fused silica and neutral-coated capillaries were investigated, as well as preconcentration methods such as transient isotachophoresis, field-amplified sample injection (FASI), and electrokinetic supercharging (EKS). The method for the separation of PTH and its variants was first developed using fused-silica capillary with UV detection. An acidic BGE was used to separate 1-84 PTH (full length), 7-84 PTH, and 1-34 PTH. Acetonitrile was added to the BGE to reduce peptide adsorption onto the capillary wall and transient isotachophoresis was used as analyte preconcentration method. The method was then transferred to a sheathless CE-ESI-MS instrument. When using a fused silica capillary, CE-MS was limited to µg/mL levels. The use of a neutral coating combined with FASI or EKS allowed a significant increase in sensitivity. Under these conditions, 1-84 PTH, 7-84 PTH, and 1-34 PTH were detected at concentrations in the low ng/mL (FASI) or pg/mL (EKS) range.


Assuntos
Eletroforese Capilar/métodos , Hormônio Paratireóideo/isolamento & purificação , Fragmentos de Peptídeos/isolamento & purificação , Desenho de Equipamento , Humanos , Isotacoforese/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos
19.
Clin Chem Lab Med ; 57(6): 864-872, 2019 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-30485171

RESUMO

Background Hepcidin concentrations measured by various methods differ considerably, complicating interpretation. Here, a previously identified plasma-based candidate secondary reference material (csRM) was modified into a serum-based two-leveled sRM. We validated its functionality to increase the equivalence between methods for international standardization. Methods We applied technical procedures developed by the International Consortium for Harmonization of Clinical Laboratory Results. The sRM, consisting of lyophilized serum with cryolyoprotectant, appeared commutable among nine different measurement procedures using 16 native human serum samples in a first round robin (RR1). Harmonization potential of the sRM was simulated in RR1 and evaluated in practice in RR2 among 11 measurement procedures using three native human plasma samples. Comprehensive purity analysis of a candidate primary RM (cpRM) was performed by state of the art procedures. The sRM was value assigned with an isotope dilution mass spectrometry-based candidate reference method calibrated using the certified pRM. Results The inter-assay CV without harmonization was 42.1% and 52.8% in RR1 and RR2, respectively. In RR1, simulation of harmonization with sRM resulted in an inter-assay CV of 11.0%, whereas in RR2 calibration with the material resulted in an inter-assay CV of 19.1%. Both the sRM and pRM passed international homogeneity criteria and showed long-term stability. We assigned values to the low (0.95±0.11 nmol/L) and middle concentration (3.75±0.17 nmol/L) calibrators of the sRM. Conclusions Standardization of hepcidin is possible with our sRM, which value is assigned by a pRM. We propose the implementation of this material as an international calibrator for hepcidin.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Hepcidinas/sangue , Espectrometria de Massas em Tandem , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Ensaio de Imunoadsorção Enzimática/normas , Hepcidinas/normas , Humanos , Marcação por Isótopo , Padrões de Referência , Espectrometria de Massas em Tandem/normas
20.
J Sep Sci ; 42(2): 609-618, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30411490

RESUMO

Rapeseed plants, known for oil production, are also known to contain phenolic compounds such as phenolic acids and flavonoids, with potential antioxidant and anticancer activities. The separation and identification of 11 phenolic acids in rapeseed extracts (including leaves, flowers, Chinese seeds, Belgian seeds, and cake) by capillary electrophoresis were investigated. The results were compared with those obtained with high-performance liquid chromatography and thin-layer chromatography and showed that the capillary electrophoresis technique offers several advantages for the identification of phenolic compounds in various rapeseed extracts. The antioxidant activity of rapeseed extracts and reference compounds was evaluated using four different approaches, namely, 2,2'-azinobis- (3-ethylbenzohiazoline-6-sulfonic acid assay, free radical 2,2-diphenyl-1-picrylhydrazyl assay, electron paramagnetic resonance spectroscopy and the measurement of the total polyphenol content. The contents of total polyphenols in the tested extracts were ranging between 5.4 and 21.1% m/m and ranked as follows: Chinese seeds ˃ Belgian seeds ˃ Flowers ˃ Cake ˃ Leaves.


Assuntos
Antioxidantes/análise , Brassica rapa/química , Fenóis/análise , Antioxidantes/farmacologia , Benzotiazóis/antagonistas & inibidores , Compostos de Bifenilo/antagonistas & inibidores , Cromatografia Líquida de Alta Pressão , Cromatografia em Camada Fina , Relação Dose-Resposta a Droga , Eletroforese Capilar , Flores/química , Fenóis/farmacologia , Picratos/antagonistas & inibidores , Extratos Vegetais/química , Folhas de Planta/química , Sementes/química , Ácidos Sulfônicos/antagonistas & inibidores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA