Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
2.
J Am Coll Cardiol ; 81(9): 849-863, 2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36858705

RESUMO

BACKGROUND: Mesenchymal precursor cells (MPCs) are allogeneic, immunoselected cells with anti-inflammatory properties that could improve outcomes in heart failure with reduced ejection fraction (HFrEF). OBJECTIVES: This study assessed the efficacy and safety of MPCs in patients with high-risk HFrEF. METHODS: This randomized, double-blind, multicenter study evaluated a single transendocardial administration procedure of MPCs or sham-control in 565 intention-to-treat patients with HFrEF on guideline-directed therapies. The primary endpoint was time-to-recurrent events caused by decompensated HFrEF or successfully resuscitated symptomatic ventricular arrhythmias. Hierarchical secondary endpoints included components of the primary endpoint, time-to-first terminal cardiac events, and all-cause death. Separate and composite major adverse cardiovascular events analyses were performed for myocardial infarction or stroke or cardiovascular death. Baseline and 12-month echocardiography was performed. Baseline plasma high-sensitivity C-reactive protein levels were evaluated for disease severity. RESULTS: The primary endpoint was similar between treatment groups (HR: 1.17; 95% CI: 0.81-1.69; P = 0.41) as were terminal cardiac events and secondary endpoints. Compared with control subjects, MPCs increased left ventricular ejection fraction from baseline to 12 months, especially in patients with inflammation. MPCs decreased the risk of myocardial infarction or stroke by 58% (HR: 0.42; 95% CI: 0.23-0.76) and the risk of 3-point major adverse cardiovascular events by 28% (HR: 0.72; 95% CI: 0.51-1.03) in the analysis population (n = 537), and by 75% (HR: 0.25; 95% CI: 0.09-0.66) and 38% (HR: 0.62; 95% CI: 0.39-1.00), respectively, in patients with inflammation (baseline high-sensitivity C-reactive protein ≥2 mg/L). CONCLUSIONS: The primary and secondary endpoints of the trial were negative. Positive signals in prespecified, and post hoc exploratory analyses suggest MPCs may improve outcomes, especially in patients with inflammation.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Acidente Vascular Cerebral , Humanos , Proteína C-Reativa , Volume Sistólico , Função Ventricular Esquerda , Inflamação , Terapia Baseada em Transplante de Células e Tecidos
3.
Circulation ; 106(18): 2340-5, 2002 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-12403664

RESUMO

BACKGROUND: Although (192)Ir intracoronary brachytherapy has been demonstrated to dramatically reduce the recurrence of in-stent restenosis, up to 24% of these patients will still require repeat target-vessel revascularization. The short- and long-term outcomes of repeat percutaneous intervention in this population have not been characterized. METHODS AND RESULTS: Analysis was performed of all patients enrolled in the GAMMA-I and GAMMA-II brachytherapy trials who underwent repeat percutaneous target lesion revascularization (TLR) because of restenosis. Subjects were divided into 2 cohorts: those who had received (192)Ir brachytherapy and those randomized to placebo. Forty-five (17.6%) of a total of 256 patients whose index treatment was intracoronary radiation therapy and 36 (29.8%) of 121 patients whose index treatment was placebo required repeat percutaneous TLR. The mean time to this first TLR was 295+/-206 days in the irradiated group and 202+/-167 days in the placebo group (P=0.03). Acute procedural success occurred in 100% of irradiated patients and 94% of placebo controls (P=0.19). After the first TLR, a subsequent TLR was required in 15 (33.3%) of 45 brachytherapy patients versus 17 (47.2%) of 36 placebo failure patients (P=0.26). There was no significant difference in time to second TLR between the 2 groups. Other long-term major adverse event rates in both groups were comparable to those of other contemporary angioplasty/stenting series. CONCLUSIONS: In those patients who "fail" (192)Ir intracoronary brachytherapy for in-stent restenosis, treatment with (192)Ir delays the time to first TLR. Additionally, repeat percutaneous intervention in these patients is safe and efficacious in the short term, with acceptable long-term results.


Assuntos
Angioplastia Coronária com Balão , Braquiterapia/efeitos adversos , Reestenose Coronária/radioterapia , Reestenose Coronária/cirurgia , Stents/efeitos adversos , Angioplastia Coronária com Balão/efeitos adversos , Estudos de Coortes , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Radioisótopos de Irídio/efeitos adversos , Radioisótopos de Irídio/uso terapêutico , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Recidiva , Reoperação , Tempo , Resultado do Tratamento
4.
Tex Heart Inst J ; 32(3): 393-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16392228

RESUMO

The transcatheter route is an emerging approach to treating valvular disease in high-risk patients. The 1st clinical antegrade transcatheter placement of an aortic valve prosthesis was reported in 2002. We describe the first retrograde transcatheter implantation of a new aortic valve prosthesis, in a 62-year-old man with inoperable calcific aortic stenosis and multiple severe comorbidities. Via the right femoral artery, a Cook introducer was advanced into the abdominal aorta. The aortic valve was crossed with a straight wire, and a pigtail catheter was advanced into the left ventricle to obtain pressure-gradient and anatomic measurements. An 18-mm valvuloplasty balloon was then used to predilate the aortic valve. Initial attempts to position the prosthetic valve caused a transient cardiac arrest. Implantation was achieved by superimposing the right coronary angiogram onto fluoroscopic landmarks in the same radiographic plane. A balloon-expandable frame was used to deliver the valve. After device implantation, the transvalvular gradient was <5 mmHg. The cardiac output increased from 1 to 5 L/min, and urine production increased to 200 mL/h. The patient was extubated on the 2nd postimplant day. Twelve hours later, he had to be reintubated because of respiratory distress and high pulmonary pressures. His condition deteriorated, and he died of biventricular failure and refractory hypotension on day 5. Despite the severe hypotension, valve function was satisfactory on echo-Doppler evaluation. In our patient, retrograde transcatheter implantation of a prosthetic aortic valve yielded excellent hemodynamic results and paved the way for further use of this technique in selected high-risk patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Animais , Estenose da Valva Aórtica/diagnóstico por imagem , Bovinos , Modelos Animais de Doenças , Ecocardiografia Doppler , Fluoroscopia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
5.
Tex Heart Inst J ; 42(2): 144-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25873826

RESUMO

We describe transcatheter aortic valve implantation in a patient who had severe peripheral artery disease. The patient's vascular condition required additional preliminary peripheral intervention to enable adequate vascular access. A 78-year-old man with severe aortic stenosis, substantial comorbidities, and severe heart failure symptoms was referred for aortic valve replacement. The patient's 20-mm aortic annulus necessitated the use of a 23-mm Edwards Sapien valve inserted through a 22F sheath, which itself needed a vessel diameter of at least 7 mm for percutaneous delivery. The left common femoral artery was selected for valve delivery. The left iliac artery and infrarenal aorta underwent extensive intervention to achieve an intraluminal diameter larger than 7 mm. After aortic valvuloplasty, valve deployment was successful, and the transaortic gradient decreased from 40 mmHg to less than 5 mmHg. The patient was discharged from the hospital 4 days postoperatively. We conclude that transcatheter aortic valve implantation can be successfully performed in patients with obstructed vascular access, including stenosis of the infrarenal aorta and the subclavian and coronary arteries.


Assuntos
Substituição da Valva Aórtica Transcateter , Idoso , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Estenose da Valva Aórtica/terapia , Calcinose/terapia , Cineangiografia , Comorbidade , Contraindicações , Ecocardiografia Transesofagiana , Humanos , Processamento de Imagem Assistida por Computador , Isquemia , Masculino , Doença Arterial Periférica , Stents , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/métodos , Ultrassonografia de Intervenção
6.
Am Heart J ; 144(4): 693-701, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12360167

RESUMO

BACKGROUND: Postinterventional ischemic myocardial dysfunction and its sequelae are still not well understood. METHODS AND RESULTS: To gain further insight into the immediate physiologic consequences of coronary interventions and to better understand the nature of changes that result from such interventions, we analyzed 96 electromechanical maps from 48 patients before and after successful, uncomplicated percutaneous coronary interventions (PCI). A NOGA system was used to construct the map of the endocardial surface. Reproducibility was confirmed by constructing 10 additional maps in 5 patients who did not undergo an intervening procedure. Discordant areas were defined as those with preserved unipolar voltage (> or =7.5 mV) and diminished linear local shortening (< or =12.5%). On the basis of comparison of the variations in the discordance values (%) in the reproducibility group, patients were considered improved (lower values), worsened (higher values), or unchanged. In the reproducibility group, the mean variation in discordance was 2.18% +/- 1.26%, whereas in the PCI group, it was 21.97% +/- 18.47%. In the PCI group (rotational atherectomy subgroup [n = 10] and stent subgroup [n = 38]), left ventricular discordance values improved in 19 patients (39.6%), worsened in 24 (50%), and remained the same in 5 (10.4%). Of all variables analyzed, only abciximab was significantly associated with postintervention improvement in discordance (P =.02; odds ratio 0.165, 95% CI 0.03-0.88), regardless of the type of intervention performed (P =.61), whereas heparin alone was associated with more discordance after intervention (odds ratio 6.07, 95% CI 1.14-32.40). CONCLUSIONS: We assessed the effect of percutaneous revascularization on myocardium by use of electromechanical data. For the first time, changes in linear local shortening in areas of preserved unipolar voltage were quantified, and worsening after successful Thrombolysis In Myocardial Infarction grade III coronary interventions was registered. The only variable associated with improvement on electromechanical data after interventions was the use of abciximab. This raises the question of the possible potential of this new diagnostic tool in assessing and quantifying postinterventional microvasculature pathological changes.


Assuntos
Angioplastia Coronária com Balão , Eletrocardiografia , Isquemia Miocárdica/fisiopatologia , Função Ventricular Esquerda/fisiologia , Abciximab , Idoso , Análise de Variância , Anticorpos Monoclonais/uso terapêutico , Anticoagulantes/uso terapêutico , Aterectomia , Feminino , Humanos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Razão de Chances , Análise de Regressão , Reprodutibilidade dos Testes , Stents
7.
Am J Cardiol ; 90(3): 243-7, 2002 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-12127611

RESUMO

Catheter-based intracoronary radiation therapy using iridium-192 (Ir-192) has been shown to be effective in reducing recurrent coronary restenosis after initial percutaneous treatment of in-stent restenosis. Patients with diabetes mellitus (DM) have a higher risk of recurrent restenosis than nondiabetics for nonstented and in-stent restenosis coronary lesions. The use of Ir-192 for preventing recurrent restenosis in such patients remains undefined. The GAMMA I trial was a prospective, randomized, double-blind, multicenter trial of 252 patients with in-stent restenosis who underwent percutaneous coronary intervention and were assigned to receive either Ir-192 (131 patients) or catheter-based placebo (121 patients). DM was present in 79 patients (31%) (41 patients received Ir-192 and 38 patients received placebo) and was absent in 173 patients (90 patients received Ir-192 and 83 patients received placebo). At 6-month follow-up in the GAMMA I trial, the angiographic in-lesion binary restenosis rate was lower in the Ir-192 arm than in the placebo arm (32.4 vs 55.3, p = 0.01). When patients were stratified by the presence of DM, the antirestenosis effect of Ir-192 was larger for diabetic patients than for nondiabetic patients (absolute in-lesion restenosis rate was reduced by 40% for diabetics and 16% for nondiabetics). Thus, adjunctive Ir-192 intracoronary radiation therapy reduces recurrent restenosis after intervention for in-stent restenosis in patients with and without DM. The relative impact of this treatment is more pronounced in diabetic patients because it appears to neutralize the added risk of recurrent restenosis seen in proliferative diabetic lesions.


Assuntos
Braquiterapia/efeitos adversos , Doença das Coronárias/terapia , Complicações do Diabetes , Radioisótopos de Irídio/administração & dosagem , Stents , Doença das Coronárias/etiologia , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva
10.
Tex Heart Inst J ; 39(3): 342-50, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22719142

RESUMO

We sought to evaluate the restoration of microcirculatory patency after primary percutaneous coronary intervention (PCI) in an unselected cohort of patients at a tertiary center.We retrospectively evaluated distributions of the Thrombolysis in Myocardial Infarction (TIMI) myocardial perfusion grade (TMPG) and the myocardial blush grade (MBG) in all primary PCI procedures performed at our institution during 2008. We defined optimal microvascular perfusion as simultaneous TMPG 3 and MBG 3 at procedure's end.Ninety-nine patients (mean age, 61.5 ± 12.7 yr; 64 men) underwent primary PCI. Microvascular perfusion was optimal in 69 patients (69.7%) and was associated with lower peaks of enzymes than those occurring in patients with suboptimal perfusion. When optimal microvascular perfusion was achieved, early spontaneous recanalization was more frequently observed, as expressed by a higher frequency of TIMI-3 flow (34.8% vs 10%; P=0.006), TMPG 3 (26% vs 3.3%; P=0.004), and MBG 3 (24.6% vs 3.3%; P=0.004) on the initial angiogram before primary PCI. A higher frequency of MBG 3 (50% vs 20%; P=0.005) was seen after initial recanalization in patients with optimal microvascular perfusion. Multiple regression analysis showed that MBG after initial recanalization and the use of drug-eluting stents were associated with optimal perfusion.Despite successful recanalization of the culprit coronary artery, optimal microvascular perfusion was achieved in less than 75% of the patients. Restoration of the microvasculature was associated with smaller infarcts. Procedure-related variables associated with suboptimal perfusion were unlikely to be causative.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Circulação Coronária , Microcirculação , Infarto do Miocárdio/terapia , Idoso , Angioplastia Coronária com Balão/instrumentação , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Stents Farmacológicos , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Imagem de Perfusão do Miocárdio , Razão de Chances , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Texas , Fatores de Tempo , Resultado do Tratamento
12.
Tex Heart Inst J ; 38(5): 491-501, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22163122

RESUMO

The mechanical behavior of endovascular coronary stents influences their therapeutic efficacy. Through computational studies, researchers can analyze device performance and improve designs. We developed a 1-dimensional finite element method, net-based algorithm and used it to analyze the effects of radial loading and bending in commercially available stents. Our computational study included designs modeled on the Express, Cypher, Xience, and Palmaz stents.We found that stents that did not fully expand were less rigid than the fully expanded stents and, therefore, exhibited larger displacement. Stents with an open-cell design, such as Express-like or Xience-like stents, had a higher bending flexibility. Stents with in-phase circumferential rings, such as the Xience-like stent, had the smallest longitudinal extension when exposed to radial compression forces. Thus, the open-cell model that had in-phase circumferential rings connected by straight horizontal struts exhibited radial stiffness, bending flexibility, and the smallest change in stent length during radial forcing. The Palmaz-like stent was the most rigid of all. These findings are supported by clinical experience.Computer simulations of the mechanical properties of endovascular stents offer sophisticated insights into the mechanical behavior of different stent designs and should be used whenever possible to help physicians decide which stent is best for treating a given lesion. Our 1-dimensional finite element method model is incomparably simpler, faster, and more accurate than the classical 3-dimensional approaches. It can facilitate stent design and may aid in stent selection in the clinical setting.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Simulação por Computador , Doença da Artéria Coronariana/terapia , Modelos Teóricos , Desenho de Prótese , Stents , Algoritmos , Angioplastia Coronária com Balão/efeitos adversos , Análise de Elementos Finitos , Humanos , Seleção de Pacientes , Falha de Prótese , Estresse Mecânico
13.
Tex Heart Inst J ; 38(3): 229-33, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21720458

RESUMO

Matrix metalloproteinases degrade the collagen content of atherosclerotic plaque and reduce plaque stability. In tissue sections of atherosclerotic plaque, the expression of matrix metalloproteinases is increased. 3-Hydroxy-3-methylglutaryl coenzyme A reductase inhibitors (statins) decrease the tissue expression of matrix metalloproteinases-1, -2, -3, and -9 in atheromatous plaque by attenuating the inflammatory process that leads to increased expression. However, it is not known whether statins decrease levels of matrix metalloproteinase-13--an enzyme crucial to the initiation of collagen degradation-as part of their plaque-stabilizing effect.We prospectively examined the effect of statin therapy on serum levels of matrix metalloproteinase-13, tissue inhibitor of metalloproteinase-1, and low-density-lipoprotein cholesterol in 14 patients with hypercholesterolemia. All were at low risk for adverse cardiovascular events and were given 20 mg/d of rosuvastatin for 4 weeks. Post-therapy levels of matrix metalloproteinase-13 and tissue inhibitor of metalloproteinase-1 were compared with baseline levels. Although low-density-lipoprotein cholesterol levels were significantly decreased in the 14 patients (mean baseline level, 152 ± 21 mg/dL vs mean post-therapy level, 73 ± 45 mg/dL; P < 0.001), matrix metalloproteinase-13 and tissue inhibitor of metalloproteinase-1 levels were unchanged (matrix metalloproteinase-13, 0.295 ± 0.06 ng/mL vs 0.323 ± 0.11 ng/mL, P = 0.12; and tissue inhibitor of metalloproteinase-1, 400.8 ± 43.4 ng/mL vs 395.3 ± 47.5 ng/mL, P = 0.26). We conclude that even though there was a decrease in low-density-lipoprotein cholesterol, short-term, high-dose rosuvastatin therapy has no effect on matrix metalloproteinase-13 and tissue inhibitor of metalloproteinase-1 levels in hypercholesterolemic patients. However, further investigation is warranted.


Assuntos
Fluorbenzenos/uso terapêutico , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipercolesterolemia/tratamento farmacológico , Metaloproteinase 13 da Matriz/sangue , Pirimidinas/uso terapêutico , Sulfonamidas/uso terapêutico , Inibidor Tecidual de Metaloproteinase-1/sangue , Adulto , Idoso , LDL-Colesterol/sangue , Feminino , Humanos , Hipercolesterolemia/enzimologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Rosuvastatina Cálcica , Texas , Fatores de Tempo , Resultado do Tratamento
17.
Clin Cardiol ; 33(5): 254-60, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20513063

RESUMO

Implantable cardioverter defibrillator (ICD) therapy reduces sudden cardiac death rates and reduces mortality in patients with ischemic heart disease and low ejection fractions. One-third of the deaths in patients with nonischemic cardiomyopathy are sudden. However, the efficacy of ICDs in the primary prevention of death in these patients is less clear. The most common cause of mortality in patients treated with ICDs is heart failure progression. ICD shocks can cause direct myocardial injury, fibrosis, inflammation, and adverse psychological outcomes, and these changes may contribute to the ventricular dysfunction in patients who already have a significantly depressed ejection fraction. We have reviewed the published randomized controlled trials and meta-analysis of prophylactic ICD therapy in the primary prevention of death in patients with nonischemic cardiomyopathy. The individual randomized controlled trials do not report a statistically significant reduction of mortality unless the ICD treatment is added to cardiac resynchronization therapy, but the meta-analysis did show a significant mortality reduction and favored ICD therapy in these patients. Medical management of many study participants was suboptimal, at least based on current guidelines. The patients with non-ischemic cardiomyopathy have good outcomes with medical therapy, and ICD therapy in this relatively low-risk population needs better selection criteria.


Assuntos
Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Cardiomiopatias/complicações , Cardiomiopatias/economia , Cardiomiopatias/mortalidade , Análise Custo-Benefício , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/economia , Cardioversão Elétrica/economia , Medicina Baseada em Evidências , Humanos , Metanálise como Assunto , Seleção de Pacientes , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA