Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cardiol J ; 26(5): 543-549, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29718532

RESUMO

BACKGROUND: The aim of the study was to evaluate subcutaneous implantable cardioverter-defibrillator (S-ICD) patients with regard to underlying etiology, peri-procedural outcome, appropriate/inappropriate shocks, and complications during follow-up. METHODS: All patients who underwent S-ICD implantation from February 2013 to March 2017 at an academic hospital in Vienna were included. Medical records were examined and follow-up interrogations of devices were conducted. RESULTS: A total of 79 S-ICD patients (58.2% males) with a mean age of 44.5 ± 17.2 years were followed for a mean duration of 12.8 ± 13.7 months. A majority of patients (58.2%) had S-ICD for primary prevention of sudden cardiac death. The most common of the 16 underlying etiologies were ischemic cardiomyopathy, non-ischemic cardiomyopathy, and idiopathic ventricular fibrillation. The lead was implanted to the left sternal border in 96.2% of cases, between muscular layers in 72.2%. Mean implant time was 45 min, 3 patients were induced, and all patients except one were programmed to two zones. Six (7.6%) patients experienced at least one appropriate therapy for ventricular arrhythmias and the time to first event ranged from 1 to 52 months. Seven patients experienced inappropriate shocks due to T-wave oversensing, atrial tachycardia with rapid atrioventricular conduction, external electromagnetic interference, and/or baseline oversensing due to lead movement. Four patients underwent revision for lead repositioning (n = 1), loose device suture (n = 1), and infection (n = 2). CONCLUSIONS: While S-ICDs are a feasible and effective treatment, issues remain with inappropriate shock and infection.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária , Adolescente , Adulto , Idoso , Arritmias Cardíacas/complicações , Arritmias Cardíacas/mortalidade , Áustria , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Fatores de Risco , Centros de Atenção Terciária , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA