1.
Eur Radiol ; 33(8): 5321-5330, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37014409

RESUMO

Since 1971 and Hounsfield's first CT system, clinical CT systems have used scintillating energy-integrating detectors (EIDs) that use a two-step detection process. First, the X-ray energy is converted into visible light, and second, the visible light is converted to electronic signals. An alternative, one-step, direct X-ray conversion process using energy-resolving, photon-counting detectors (PCDs) has been studied in detail and early clinical benefits reported using investigational PCD-CT systems. Subsequently, the first clinical PCD-CT system was commercially introduced in 2021. Relative to EIDs, PCDs offer better spatial resolution, higher contrast-to-noise ratio, elimination of electronic noise, improved dose efficiency, and routine multi-energy imaging. In this review article, we provide a technical introduction to the use of PCDs for CT imaging and describe their benefits, limitations, and potential technical improvements. We discuss different implementations of PCD-CT ranging from small-animal systems to whole-body clinical scanners and summarize the imaging benefits of PCDs reported using preclinical and clinical systems. KEY POINTS: • Energy-resolving, photon-counting-detector CT is an important advance in CT technology. • Relative to current energy-integrating scintillating detectors, energy-resolving, photon-counting-detector CT offers improved spatial resolution, improved contrast-to-noise ratio, elimination of electronic noise, increased radiation and iodine dose efficiency, and simultaneous multi-energy imaging. • High-spatial-resolution, multi-energy imaging using energy-resolving, photon-counting-detector CT has been used in investigations into new imaging approaches, including multi-contrast imaging.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Animais , Tomografia Computadorizada por Raios X/métodos , Fótons , Raios X , Imagens de Fantasmas
2.
Eur Radiol ; 33(8): 5309-5320, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37020069

RESUMO

The X-ray detector is a fundamental component of a CT system that determines the image quality and dose efficiency. Until the approval of the first clinical photon-counting-detector (PCD) system in 2021, all clinical CT scanners used scintillating detectors, which do not capture information about individual photons in the two-step detection process. In contrast, PCDs use a one-step process whereby X-ray energy is converted directly into an electrical signal. This preserves information about individual photons such that the numbers of X-ray in different energy ranges can be counted. Primary advantages of PCDs include the absence of electronic noise, improved radiation dose efficiency, increased iodine signal and the ability to use lower doses of iodinated contrast material, and better spatial resolution. PCDs with more than one energy threshold can sort the detected photons into two or more energy bins, making energy-resolved information available for all acquisitions. This allows for material classification or quantitation tasks to be performed in conjunction with high spatial resolution, and in the case of dual-source CT, high pitch, or high temporal resolution acquisitions. Some of the most promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value. These include imaging of the inner ear, bones, small blood vessels, heart, and lung. This review describes the clinical benefits observed to date and future directions for this technical advance in CT imaging. KEY POINTS: • Beneficial characteristics of photon-counting detectors include the absence of electronic noise, increased iodine signal-to-noise ratio, improved spatial resolution, and full-time multi-energy imaging. • Promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value and applications requiring multi-energy data simultaneous with high spatial and/or temporal resolution. • Future applications of PCD-CT technology may include extremely high spatial resolution tasks, such as the detection of breast micro-calcifications, and quantitative imaging of native tissue types and novel contrast agents.


Assuntos
Compostos de Iodo , Iodo , Humanos , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Meios de Contraste , Fótons , Imagens de Fantasmas
3.
Radiology ; 303(1): 130-138, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34904876

RESUMO

Background The first clinical CT system to use photon-counting detector (PCD) technology has become available for patient care. Purpose To assess the technical performance of the PCD CT system with use of phantoms and representative participant examinations. Materials and Methods Institutional review board approval and written informed consent from four participants were obtained. Technical performance of a dual-source PCD CT system was measured for standard and high-spatial-resolution (HR) collimations. Noise power spectrum, modulation transfer function, section sensitivity profile, iodine CT number accuracy in virtual monoenergetic images (VMIs), and iodine concentration accuracy were measured. Four participants were enrolled (between May 2021 and August 2021) in this prospective study and scanned using similar or lower radiation doses as their respective clinical examinations performed on the same day using energy-integrating detector (EID) CT. Image quality and findings from the participants' PCD CT and EID CT examinations were compared. Results All standard technical performance measures met accreditation and regulatory requirements. Relative to filtered back-projection reconstructions, images from iterative reconstruction had lower noise magnitude but preserved noise power spectrum shape and peak frequency. Maximum in-plane spatial resolutions of 125 and 208 µm were measured for HR and standard PCD CT scans, respectively. Minimum values for section sensitivity profile full width at half maximum measurements were 0.34 mm (0.2-mm nominal section thickness) and 0.64 mm (0.4-mm nominal section thickness) for HR and standard PCD CT scans, respectively. In a 120-kV standard PCD CT scan of a 40-cm phantom, VMI iodine CT numbers had a mean percentage error of 5.7%, and iodine concentration had root mean squared error of 0.5 mg/cm3, similar to previously reported values for EID CT. VMIs, iodine maps, and virtual noncontrast images were created for a coronary CT angiogram acquired with 66-msec temporal resolution. Participant PCD CT images showed up to 47% lower noise and/or improved spatial resolution compared with EID CT. Conclusion Technical performance of clinical photon-counting detector (PCD) CT is improved relative to that of a current state-of-the-art CT system. The dual-source PCD geometry facilitated 66-msec temporal resolution multienergy cardiac imaging. Study participant images illustrated the effect of the improved technical performance. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Willemink and Grist in this issue.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Fótons , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
4.
Eur Radiol ; 31(12): 9211-9220, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34050386

RESUMO

OBJECTIVES: The purpose of this study was twofold. First, the influence of a novel calcium-aware (Ca-aware) computed tomography (CT) reconstruction technique on coronary artery calcium (CAC) scores surrounded by a variety of tissues was assessed. Second, the performance of the Ca-aware reconstruction technique on moving CAC was evaluated with a dynamic phantom. METHODS: An artificial coronary artery, containing two CAC of equal size and different densities (196 ± 3, 380 ± 2 mg hydroxyapatite cm-3), was moved in the center compartment of an anthropomorphic thorax phantom at different heart rates. The center compartment was filled with mixtures, which resembled fat, water, and soft tissue equivalent CT numbers. Raw data was acquired with a routine clinical CAC protocol, at 120 peak kilovolt (kVp). Subsequently, reduced tube voltage (100 kVp) and tin-filtration (150Sn kVp) acquisitions were performed. Raw data was reconstructed with a standard and a novel Ca-aware reconstruction technique. Agatston scores of all reconstructions were compared with the reference (120 kVp) and standard reconstruction technique, with relevant deviations defined as > 10%. RESULTS: For all heart rates, Agatston scores for CAC submerged in fat were comparable to the reference, for the reduced-kVp acquisition with Ca-aware reconstruction kernel. For water and soft tissue, medium-density Agatston scores were again comparable to the reference for all heart rates. Low-density Agatston scores showed relevant deviations, up to 15% and 23% for water and soft tissue, respectively. CONCLUSION: CT CAC scoring with varying surrounding materials and heart rates is feasible at patient-specific tube voltages with the novel Ca-aware reconstruction technique. KEY POINTS: • A dedicated calcium-aware reconstruction kernel results in similar Agatston scores for CAC surrounded by fatty materials regardless of CAC density and heart rate. • Application of a dedicated calcium-aware reconstruction kernel allows for radiation dose reduction. • Mass scores determined with CT underestimated physical mass.


Assuntos
Cálcio , Doença da Artéria Coronariana , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Frequência Cardíaca , Humanos , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
5.
Eur Radiol ; 30(8): 4164-4174, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32189051

RESUMO

OBJECTIVE: To evaluate the feasibility of one-stop pancreatic perfusion CT with mean temporal (MT) imaging replacing the combination of a bi-phasic scan plus a perfusion scan to detect insulinoma. MATERIAL AND METHODS: Forty-five patients with suspected insulinoma, who underwent both biphasic and perfusion CT, were enrolled in this retrospective study. MT datasets including images for different delineation purposes were generated by averaging 3 dynamic datasets from perfusion CT, which are MTA for arterial, MTPV for portal vein and MTO for lesions. Two readers assessed the image quality and diagnostic performance separately for biphasic and MT datasets. Radiation doses were also assessed. Paired t tests, Wilcoxon signed-rank tests and McNemar's tests were applied for comparison. RESULTS: Compared with bi-phasic CT images, image noise, SNR and CNR of the MTA and MTPV datasets were all non-inferior (noise and CNR of the portal vein, p = 0.565 and p = 0.227, respectively) or superior (p ≤ 0.001). The subjective image quality was better in the MTA and MTPV images (p < 0.001 to p = 0.004). The sensitivity and NPV of MT images were also better (95% vs 75% and 75% vs 37.5% for reader 1; 97.5% vs 72.5% and 85.7% vs 35.3% for reader 2). Omitting the bi-phasic scan resulted in a dose reduction of 25% ± 4%. CONCLUSION: MT imaging can allow pancreatic perfusion CT to be used alone without the need for an additional bi-phasic CT in the detection of insulinoma. KEY POINTS: • Mean temporal images reconstructed from perfusion CT with an averaging technique reproduce usual bi-phasic images (arterial and portal phases). • The image quality of mean temporal images is non-inferior or superior to native bi-phasic CT. The sensitivity and NPV for the diagnosis of insulinoma are better for mean temporal images than for traditional bi-phasic CT. • Mean temporal imaging can allow pancreatic perfusion CT to be used alone without the need for an additional bi-phasic CT in the detection of insulinoma. Radiation dose saving is important.


Assuntos
Insulinoma/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Imagem de Perfusão/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Intensificação de Imagem Radiográfica , Estudos Retrospectivos , Adulto Jovem
6.
Radiology ; 291(2): 531-538, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30835189

RESUMO

Background Optimal timing of the CT scan relative to the contrast media bolus remains a challenging task given the shorter scan durations of modern CT scanners, as well as interpatient variability. Purpose To compare contrast opacification in CT angiography of the aorta between a cohort with fixed trigger delay and a cohort with patient-specific individualized trigger delay for contrast media timing with bolus tracking. Materials and Methods In this prospective study (January-August 2018), CT angiography of the thoracoabdominal aorta with bolus tracking was performed in two different study cohorts: one with a fixed trigger delay of 4 seconds (fixed cohort) and one with a patient-specific trigger delay (individualized cohort). All CT and contrast media protocol parameters were kept identical among cohorts. Objective image quality was evaluated by one reader; two readers assessed subjective image quality. Student t test was used to test for differences in mean attenuation; the Wilcoxon-Mann-Whitney test was used to test for differences in noise, contrast-to-noise ratio, and subjective image quality. Results The fixed cohort had 108 study participants (16 women; mean age ± standard deviation, 72 years ± 10); the individualized cohort had 108 participants (16 women; mean age, 72 years ± 12). The trigger delay in the individualized cohort ranged from 6.4-11.3 seconds (mean, 9.2 seconds). There was higher overall attenuation in the individualized cohort than in the fixed cohort (486 HU ± 92 for individualized vs 438 HU ± 99 for fixed; P < .001), with increasing differences from the aortic arch (8 HU) to the iliac arteries (95 HU). The regression model indicated uniform attenuation in the individualized cohort and decreasing attenuation in the fixed cohort (decrease of 87 HU by the iliac arteries; P < .001). There was no difference between cohorts for image noise (20 vs 19; P = .41), but contrast-to-noise ratio (21 vs 19; P = .04) and subjective image quality were higher in the individualized cohort than in the fixed cohort (excellent or good image quality, 100% vs 67%; P < .001). Conclusion Compared with a fixed delay time after bolus tracking, a patient-specific individualized trigger delay improves image quality and provides uniform contrast attenuation for CT angiography of the aorta. ©RSNA, 2019.


Assuntos
Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Aortografia/métodos , Feminino , Humanos , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
7.
Eur Radiol ; 27(5): 2047-2054, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27572809

RESUMO

OBJECTIVES: To evaluate detectability and quantification of coronary calcifications for CT with a tin filter for spectral shaping. METHODS: Phantom inserts with 100 small and 9 large calcifications, and a moving artificial artery with 3 calcifications (speed 0-30 mm/s) were placed in a thorax phantom simulating different patient sizes. The phantom was scanned in high-pitch spiral mode at 100 kVp with tin filter (Sn100 kVp), and at a reference of 120 kVp, with electrocardiographic (ECG) gating. Detectability and quantification of calcifications were analyzed for standard (130 HU) and adapted thresholds. RESULTS: Sn100 kVp yielded lower detectability of calcifications (9 % versus 12 %, p = 0.027) and lower Agatston scores (p < 0.008), irrespective of calcification, patient size and speed. Volume scores of the moving calcifications for Sn100 kVp at speed 10-30 mm/s were lower (p < 0.001), while mass scores were similar (p = 0.131). For Sn100 kVp with adapted threshold of 117 HU, detectability (p = 1.000) and Agatston score (p > 0.206) were similar to 120 kVp. Spectral shaping resulted in median dose reduction of 62.3 % (range 59.0-73.4 %). CONCLUSIONS: Coronary calcium scanning with spectral shaping yields lower detectability of calcifications and lower Agatston scores compared to 120 kVp scanning, for which a HU threshold correction should be developed. KEY POINTS: • Sn100kVp yields lower detectability and lower Agatston scores compared to 120kVp • Adapted HU threshold for Sn100kVp provides Agatston scores comparable to 120kVp • Sn100 kVp considerably reduces dose in calcium scoring versus 120 kVp.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
8.
AJR Am J Roentgenol ; 204(4): 743-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25794063

RESUMO

OBJECTIVE: The purpose of this study was to determine whether ultralow-radiation-dose chest CT can be used for quantification of lung density and for emphysema detection in participants undergoing lung cancer screening. SUBJECTS AND METHODS: Fifty-two patients were prospectively enrolled and underwent scanning twice with low-dose CT (reference parameters, 120 kV, 50 effective mAs) and ultralow-dose CT (reference parameters, 80 kV, 4-5 effective mAs). Images were reconstructed by filtered back projection (FBP) for low-dose CT and FBP and iterative reconstruction (IR) for ultralow-dose CT. Radiation dose was recorded. Image noise, mean lung attenuation, 15th percentile of lung attenuation, and emphysema index were measured in each image series and compared. Test characteristics of ultralow-dose CT in detecting more than subtle emphysema (emphysema index≥3%) were calculated. RESULTS: The effective dose of low-dose CT was 2.1±0.5 mSv, and that of ultralow-dose CT was 0.13±0.04 mSv. Compared with the findings for low-dose CT, absolute overestimation of emphysema index was 7% on ultralow-dose CT images reconstructed with FBP and 2% on those processed with IR. The 15th percentile of lung attenuation was underestimated by 21.3 HU on ultralow-dose FBP images and by 5.8 HU on IR images. No relevant bias was observed for mean lung attenuation. Four patients (8%) had more than subtle emphysema. The emphysema index measured at ultralow-dose CT with FBP and IR had 100% and 100% sensitivity and 92% and 96% specificity in identifying patients with more than subtle emphysema at a cutoff of greater than 12.1% for FBP and greater than 6.7% for IR. CONCLUSION: Ultralow-dose chest CT performed for lung cancer screening can be used for quantification of lung density and for emphysema detection. IR improves the accuracy of ultralow-dose CT in this setting.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Sensibilidade e Especificidade , Fumar/efeitos adversos
9.
Eur Radiol ; 24(2): 512-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24141716

RESUMO

PURPOSE: To assess the accuracy of dual-energy CT (DECT) for the quantification of iodine concentrations in a thoracic phantom across various cardiac DECT protocols and simulated patient sizes. MATERIALS AND METHODS: Experiments were performed on first- and second-generation dual-source CT (DSCT) systems in DECT mode using various cardiac DECT protocols. An anthropomorphic thoracic phantom was equipped with tubular inserts containing known iodine concentrations (0-20 mg/mL) in the cardiac chamber and up to two fat-equivalent rings to simulate different patient sizes. DECT-derived iodine concentrations were measured using dedicated software and compared to true concentrations. General linear regression models were used to identify predictors of measurement accuracy RESULTS: Correlation between measured and true iodine concentrations (n = 72) across CT systems and protocols was excellent (R = 0.994-0.997, P < 0.0001). Mean measurement errors were 3.0 ± 7.0% and -2.9 ± 3.8% for first- and second-generation DSCT, respectively. This error increased with simulated patient size. The second-generation DSCT showed the most stable measurements across a wide range of iodine concentrations and simulated patient sizes. CONCLUSION: Overall, DECT provides accurate measurements of iodine concentrations across cardiac CT protocols, strengthening the case for DECT-derived blood volume estimates as a surrogate of myocardial blood supply. KEY POINTS: • Dual-energy CT provides new opportunities for quantitative assessment in cardiac imaging. • DECT can quantify myocardial iodine as a surrogate for myocardial perfusion. • DECT measurements of iodine concentrations are overall very accurate. • The accuracy of such measurements decreases as patient size increases.


Assuntos
Coração/diagnóstico por imagem , Iodo , Miocárdio/metabolismo , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Humanos , Iodo/farmacocinética , Reprodutibilidade dos Testes , Software
10.
Eur Radiol ; 24(7): 1643-50, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24816937

RESUMO

OBJECTIVES: To assess the influence of tube potential on radiation dose and image quality of third-generation dual-source coronary CT angiography (CTA) in a phantom simulating an obese patient. METHODS: A thoracic phantom was equipped with tubular inserts containing iodine solution and water. A soft-tissue-equivalent ring around the phantom simulated an obese patient. Images were acquired at tube potentials of 80, 100, 120 and 140 kV with second-generation dual-source CT (DSCT) and 70-150 kV (in 10-kV increments) with third-generation DSCT. Contrast-to-noise ratio (CNR) was calculated and CT dose index was recorded. RESULTS: With second-generation DSCT, CNR was highest for 120 kV (19.0) and decreased with lower tube potential (12.0 at 80 kV) owing to disproportionately increased image noise. With third-generation DSCT, 70- and 80-kV acquisitions showed a smaller increase in noise. CNRs for third-generation DSCT were highest for 70 and 80 kV (21.1 and 21.2, respectively). Compared to 120 kV, radiation dose was 68% and 49% lower at 70 kV and 80 kV, respectively. CONCLUSION: Third-generation DSCT enables one to perform coronary CTA at 70-80 kV in obese patients without compromising CNR and thus reduces radiation dose by 49-68%. KEY POINTS: • Low tube potential CT angiography is currently not suitable for obese patients. • Third-generation DSCT offers substantially increased tube power at low tube potential. • This enables one to perform coronary CT angiography at 70-80 kV in obese patients. • Signal-to-noise ratio is maintained owing to increased tube current. • This approach can be expected to reduce radiation dose by 49-68%.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada Multidetectores/normas , Obesidade/complicações , Imagens de Fantasmas , Doença da Artéria Coronariana/complicações , Humanos , Doses de Radiação , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
11.
Invest Radiol ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38742928

RESUMO

OBJECTIVE: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. MATERIALS AND METHODS: A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. RESULTS: Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy (R2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. CONCLUSIONS: This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.

12.
Invest Radiol ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38526041

RESUMO

OBJECTIVES: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. MATERIALS AND METHODS: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. RESULTS: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions (R2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. CONCLUSIONS: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as-in distinction to iodine-both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.

13.
AJR Am J Roentgenol ; 201(1): 23-32, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23789655

RESUMO

OBJECTIVE: The purpose of this study was to compare image quality and lesion detectability in the evaluation of hypervascular hepatocellular carcinoma (HCC) on low-tube-voltage half-dose liver CT scans subjected to sinogram-affirmed iterative reconstruction (SAFIRE) with the quality and detectability on full-dose scans reconstructed with filtered back projection (FBP). MATERIALS AND METHODS: A total of 126 patients with suspected HCC who underwent liver CT including arterial phase scanning at 80 kVp in the dual-source mode (300 mAs for each tube) were included in the study. The half-dose arterial scans were reconstructed with FBP, iterative reconstruction in image space (IRIS), and five SAFIRE strengths (S1-S5) and were compared with full-dose virtual scans (600 mA) reconstructed with FBP. We assessed image noise, contrast-to-noise ratio (CNR) of the liver and blood vessels, and lesionto-liver CNR. Two radiologists evaluated image quality and lesion detectability attained with the different imaging sets. RESULTS: Image noise on SAFIRE images was significantly lower than that on the other images, and the CNRs on SAFIRE images were higher than those on half-dose FBP images (p < 0.001). In addition, lesion-to-liver CNR on the half-dose S5 SAFIRE images was higher than on IRIS and full-dose FBP images (p < 0.05). Among the half-dose scans, SAFIRE images had significantly better image quality than FBP images (p < 0.05). Regarding lesion detection, half-dose SAFIRE images were better than half-dose FBP images and were comparable with full-dose FBP images (observer 1, 91.8% vs 96%; observer 2, 98% vs 98%; p > 0.05). CONCLUSION: Performing half-dose 80-kVp liver CT with SAFIRE technique may increase image quality and afford comparable lesion detectability of hypervascular HCC at a reduced radiation dose compared with full-dose CT with FBP.


Assuntos
Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Razão Sinal-Ruído , Estatísticas não Paramétricas
14.
Diagnostics (Basel) ; 13(3)2023 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-36766563

RESUMO

Background: This study evaluated the feasibility of reducing the radiation dose in abdominal imaging of urolithiasis with a clinical photon-counting CT (PCCT) by gradually lowering the image quality level (IQL) without compromising the image quality and diagnostic value. Methods: Ninety-eight PCCT examinations using either IQL70 (n = 31), IQL60 (n = 31) or IQL50 (n = 36) were retrospectively included. Parameters for the radiation dose and the quantitative image quality were analyzed. Qualitative image quality, presence of urolithiasis and diagnostic confidence were rated. Results: Lowering the IQL from 70 to 50 led to a significant decrease (22.8%) in the size-specific dose estimate (SSDE, IQL70 4.57 ± 0.84 mGy, IQL50 3.53 ± 0.70 mGy, p < 0.001). Simultaneously, lowering the IQL led to a minimal deterioration of the quantitative quality, e.g., image noise increased from 9.13 ± 1.99 (IQL70) to 9.91 ± 1.77 (IQL50, p = 0.248). Radiologists did not notice major changes in the image quality throughout the IQLs. Detection rates of urolithiasis (91.3-100%) did not differ markedly. Diagnostic confidence was high and not influenced by the IQL. Conclusions: Adjusting the PCCT scan protocol by lowering the IQL can significantly reduce the radiation dose without significant impairment of the image quality. The detection rate and diagnostic confidence are not impaired by using an ultra-low-dose PCCT scan protocol.

15.
Clin Imaging ; 102: 109-115, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37672849

RESUMO

PURPOSE: Advantages of virtual monoenergetic images (VMI) have been reported for dual energy CT of the head and neck, and more recently VMIs derived from photon-counting (PCCT) angiography of the head and neck. We report image quality metrics of VMI in a PCCT angiography dataset, expanding the anatomical regions evaluated and extending observer-based qualitative methods further than previously reported. METHODS: In a prospective study, asymptomatic subjects underwent contrast enhanced PCCT of the head and neck using an investigational scanner. Image sets of low, high, and full spectrum (Threshold-1) energies; linear mix of low and high energies (Mix); and 23 VMIs (40-150 keV, 5 keV increments) were generated. In 8 anatomical locations, SNR and radiologists' preferences for VMI energy levels were measured using a forced-choice rank method (4 observers) and ratings of image quality using visual grading characteristic (VGC) analysis (2 observers) comparing VMI to Mix and Threshold-1 images. RESULTS: Fifteen subjects were included (7 men, 8 women, mean 57 years, range 46-75). Among all VMIs, SNRs varied by anatomic location. The highest SNRs were observed in VMIs. Radiologists preferred 50-60 keV VMIs for vascular structures and 75-85 keV for all other structures. Cumulative ratings of image quality averaged across all locations were higher for VMIs with areas under the curve of VMI vs Mix and VMI vs Threshold-1 of 0.67 and 0.68 for the first reader and 0.72 and 0.76 for the second, respectively. CONCLUSION: Preferred keV level and quality ratings of VMI compared to mixed and Threshold-1 images varied by anatomical location.


Assuntos
Cabeça , Pescoço , Masculino , Feminino , Humanos , Estudos Prospectivos , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia
16.
Radiology ; 265(1): 70-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22771886

RESUMO

PURPOSE: To investigate whether coronary artery calcium (CAC) scoring performed on three different workstations generates comparable and thus vendor-independent results. MATERIALS AND METHODS: Institutional review board and Federal Office for Radiation Protection approval were received, as was each patient's written informed consent. Fifty-nine patients (37 men, 22 women; mean age, 57 years±3 [standard deviation]) underwent CAC scoring with use of 64-section multidetector computed tomography (CT) with retrospective electrocardiographic gating (one examination per patient). Data sets were created at 10% increments of the R-R interval from 40%-80%. Two experienced observers in consensus calculated Agatston and volume scores for all data sets by using the calcium scoring software of three different workstations. Comparative analysis of CAC scores between the workstations was performed by using regression analysis, Spearman rank correlation (rs), and the Kruskal-Wallis test. RESULTS: Each workstation produced different absolute numeric results for Agatston and volume scores. However, statistical analysis revealed excellent correlation between the workstations, with highest correlation at 60% of the R-R interval (minimal rs=0.998; maximal rs=0.999) for both scoring methods. No significant differences were detected for Agatston and volume score results between the software platforms. At analysis of individual reconstruction intervals, each workstation demonstrated the same score variability, with the consequence that 12 of 59 patients were assigned to divergent cardiac risk groups by using at least one of the workstations. CONCLUSION: While mere numeric values might be different, commercially available software platforms produce comparable CAC scoring results, which suggests a vendor-independence of the method; however, none of the analyzed software platforms appears to provide a distinct advantage for risk stratification, as the variability of CAC scores depending on the reconstruction interval persists across platforms.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Tomografia Computadorizada por Raios X/normas , Técnicas de Imagem de Sincronização Cardíaca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Estatísticas não Paramétricas
17.
Radiology ; 265(2): 437-47, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23012467

RESUMO

PURPOSE: To retrospectively determine whether the combined use of automatic tube voltage selection (ATVS) and automatic tube current modulation (ATCM) can effectively reduce radiation dose at contrast material-enhanced liver computed tomography (CT) while maintaining acceptable image quality compared with the use of ATCM alone. MATERIALS AND METHODS: This study was approved by an institutional review board, and informed consent was waived. Three hundred fourteen consecutive patients suspected of having liver disease were divided into three groups. In two groups, both ATVS and ATCM were used (group A1, n=97; group A2, n=101) but with different contrast gain settings; in one group, only ATCM with a fixed tube potential of 120 kV (group B, n=116) was used. Weighted volume CT dose index and dose-length product, contrast-to-noise ratios (CNRs), and mean image noise were assessed. Qualitative analysis was performed by two board-certified radiologists and one radiology resident. Statistical analysis was performed by using the one-way analysis of variance test, two-tailed paired t test, Kruskal-Wallis test, and noninferiority test. RESULTS: In groups A1 and A2, a significant dose reduction was obtained compared with that in group B (P<.0001). The mean dose reduction was 20% in group A1 and 31% in group A2. Furthermore, CNRs were significantly higher in groups A1 and A2 than in group B (P<.0001). Despite the higher image noise in groups A1 and A2, the overall image quality was acceptable. CONCLUSION: Compared with the use of ATCM alone, the combined use of ATVS and ATCM allowed reduction of radiation exposure while maintaining good image quality at contrast-enhanced liver CT.


Assuntos
Hepatopatias/diagnóstico por imagem , Hepatopatias/epidemiologia , Doses de Radiação , Proteção Radiológica/métodos , Proteção Radiológica/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Intensificação de Imagem Radiográfica/métodos , Radiometria , Reprodutibilidade dos Testes , República da Coreia/epidemiologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
18.
Acad Radiol ; 29(5): 689-697, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34389259

RESUMO

RATIONALE AND OBJECTIVES: To determine quantitative and qualitative image quality of contrast-enhanced abdominal photon-counting detector CT (PCD-CT) compared to energy-integrating detector CT (EID-CT) in the same patients. MATERIAL AND METHODS: Thirty-nine patients (mean age 63 ± 10 years, 10 females, mean BMI 26.0 ± 5.7 kg/m2) were retrospectively included who underwent clinically indicated, contrast-enhanced abdominal CT in portal-venous phase with first-generation dual-source PCD-CT and who underwent previous abdominal CT with EID-CT. For both scan, same contrast media protocol was used. PCD-CT was performed in QuantumPlus mode (obtaining full spectral information) at 120kVp. EID-CT was performed using automated tube voltage selection (reference tube voltage 100kVp). In PCD-CT, virtual monoenergetic images (VMI) were reconstructed in 10keV intervals (40-90 keV). Tube current-time product in PCD-CT was modified in each patient to obtain same volume CT-dose-index (CTDIvol) as with EID-CT. Attenuation of organs and vascular structures were measured, noise quantified, and contrast-to-noise ratio (CNR) calculated. Two independent, blinded radiologists assessed subjective image quality using a 5-point Likert scale (overall image quality, image noise, contrast, and liver lesion conspicuity). RESULTS: Median time interval between the scan was 12 months. BMI (p = 0.905) and CTDIvol (p = 0.984) were similar between scans. CNRparenchymal and CNRvascular of VMI from PCD-CT at 40 and 50keV were significantly higher than EID-CT (all, p < 0.05). Overall, inter-reader agreement for all subjective image quality readings was substantial (Krippendorff's alpha = 0.773). Overall image quality of VMI was rated similar at 50 and 60 keV compared to EID-CT (all, p > 0.05). Subjective image noise was significantly higher at 40-50 keV, contrast significantly higher at 40-60 keV (all, p < 0.05). Lesion conspicuity was rated similar on all images. CONCLUSION: Our intra-individual analysis of abdominal PCD-CT indicates that VMI at 50 keV shows significantly higher CNR at similar subjective image quality as compared to EID-CT at identical radiation dose.


Assuntos
Abdome , Tomografia Computadorizada por Raios X , Abdome/diagnóstico por imagem , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
19.
Diagnostics (Basel) ; 12(2)2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35204611

RESUMO

The aim of this study was to characterize image quality and to determine the optimal strength levels of a novel iterative reconstruction algorithm (quantum iterative reconstruction, QIR) for low-dose, ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) of the lung. Images were acquired on a clinical dual-source PCD-CT in the UHR mode and reconstructed with a sharp lung reconstruction kernel at different strength levels of QIR (QIR-1 to QIR-4) and without QIR (QIR-off). Noise power spectrum (NPS) and target transfer function (TTF) were analyzed in a cylindrical phantom. 52 consecutive patients referred for low-dose UHR chest PCD-CT were included (CTDIvol: 1 ± 0.6 mGy). Quantitative image quality analysis was performed computationally which included the calculation of the global noise index (GNI) and the global signal-to-noise ratio index (GSNRI). The mean attenuation of the lung parenchyma was measured. Two readers graded images qualitatively in terms of overall image quality, image sharpness, and subjective image noise using 5-point Likert scales. In the phantom, an increase in the QIR level slightly decreased spatial resolution and considerably decreased noise amplitude without affecting the frequency content. In patients, GNI decreased from QIR-off (202 ± 34 HU) to QIR-4 (106 ± 18 HU) (p < 0.001) by 48%. GSNRI increased from QIR-off (4.4 ± 0.8) to QIR-4 (8.2 ± 1.6) (p < 0.001) by 87%. Attenuation of lung parenchyma was highly comparable among reconstructions (QIR-off: -849 ± 53 HU to QIR-4: -853 ± 52 HU, p < 0.001). Subjective noise was best in QIR-4 (p < 0.001), while QIR-3 was best for sharpness and overall image quality (p < 0.001). Thus, our phantom and patient study indicates that QIR-3 provides the optimal iterative reconstruction level for low-dose, UHR PCD-CT of the lungs.

20.
Invest Radiol ; 57(2): 115-121, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34352805

RESUMO

PURPOSE: The aims of this study were to determine the objective and subjective image quality of high-pitch computed tomography (CT) angiography of the aorta in clinical dual-source photon-counting detector CT (PCD-CT) and to compare the image quality to conventional dual-source energy-integrating detector CT (EID-CT) in the same patients at equal radiation dose. MATERIALS AND METHODS: Patients with prior CT angiography of the thoracoabdominal aorta acquired on third-generation dual-source EID-CT in the high-pitch mode and with automatic tube voltage selection (ATVS, reference tube voltage 100 kV) were included. Follow-up imaging was performed on a first-generation, clinical dual-source PCD-CT scanner in the high-pitch and multienergy (QuantumPlus) mode at 120 kV using the same contrast media protocol as with EID-CT. Radiation doses between scans were matched by adapting the tube current of PCD-CT. Polychromatic images for both EID-CT and PCD-CT (called T3D) and virtual monoenergetic images at 40, 45, 50, and 55 keV for PCD-CT were reconstructed. Computed tomography attenuation was measured in the aorta; noise was defined as the standard deviation of attenuation; contrast-to-noise ratio (CNR) was calculated. Subjective image quality (noise, vessel attenuation, vessel sharpness, and overall quality) was rated by 2 blinded, independent radiologists. RESULTS: Forty patients were included (mean age, 63 years; 8 women; mean body mass index [BMI], 26 kg/m2). There was no significant difference in BMI, effective diameter, or radiation dose between scans (all P's > 0.05). The ATVS in EID-CT selected 70, 80, 90, 100, 110, and 120 kV in 2, 14, 14, 7, 2, and 1 patients, respectively. Mean CNR was 17 ± 8 for EID-CT and 22 ± 7, 20 ± 6, 18 ± 5, 16 ± 5, and 12 ± 4 for PCD-CT at 40, 45, 50, 55 keV, and T3D, respectively. Contrast-to-noise ratio was significantly higher for 40 and 45 keV of PCD-CT as compared with EID-CT (both P's < 0.05). The linear regression model (adjusted R2, 0.38; P < 0.001) revealed that PCD-CT reconstruction (P < 0.001), BMI group (P = 0.007), and kV of the EID-CT scan (P = 0.01) were significantly associated with CNR difference, with an increase by 34% with PCD-CT for overweight as compared with normal weight patients. Subjective image quality reading revealed slight differences between readers for subjective vessel attenuation and sharpness, whereas subjective noise was rated significantly higher for 40 and 45 keV (P < 0.001) and overall quality similar (P > 0.05) between scans. CONCLUSIONS: High-pitch PCD-CT angiography of the aorta with VMI at 40 and 45 keV resulted in significantly increased CNR compared with EID-CT with ATVS at matched radiation dose. The CNR gain of PCD-CT increased in overweight patients. Taking into account the subjective analysis, VMI at 45 to 50 keV is proposed as the best trade-off between objective and subjective image quality.


Assuntos
Angiografia por Tomografia Computadorizada , Sobrepeso , Angiografia , Aorta , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Fótons , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos