Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Am J Perinatol ; 37(1): 112-118, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31905408

RESUMO

OBJECTIVE: We evaluate diagnostic accuracy of the ARCHITECT chemiluminescent immunoassay (CIA) screening test in pregnancy, and evaluate pregnancy outcomes among screen-positive women. STUDY DESIGN: Samples from routine prenatal rapid plasma reagin (RPR) tests were collected between June 22 and August 18, 2017 and frozen. Samples were batch-tested with the Abbott ARCHITECT syphilis TP immunoassay (CIA, index test). We calculated sensitivity, specificity, predictive value, and false positivity. We compared pregnancy and neonatal outcomes among screen-positive women. RESULTS: Of 1,602 specimens, 35 (2.2%) were RPR + ; of those, 24 (69%) were CIA +/Treponema pallidum particle agglutination assay (TPPA)+ and 11 (31%) were CIA-/TPPA-. Of 1,567 RPR- specimens, 14 (0.9%) were CIA + ; of those, 13 (93%) were TPPA + , and one (7%) had a false positive CIA test. Sensitivity of the CIA (95% CI) was 100% (90.5-100%), specificity 99.9% (99.6-100%), positive predictive value 97.4% (86.2-99.9%), and false positive rate 0.06% (0.002-0.4%) for current or past syphilis. Among 37 CIA +/TPPA+ women, seven (19%) had RPR-negative status (Group 1), 11 (30%) had previously treated syphilis (Group 2), and 19 (51%) had active infection (Group 3). One stillbirth occurred in a woman with early, active syphilis identified at delivery; no adverse perinatal outcomes occurred among women in Groups 1 or 2. CONCLUSION: The ARCHITECT syphilis TP immunoassay accurately diagnoses current or past syphilis in pregnancy. Clinical history and staging remain essential using a reverse algorithm.


Assuntos
Algoritmos , Imunoensaio/métodos , Complicações Infecciosas na Gravidez/diagnóstico , Sífilis/diagnóstico , Treponema pallidum/isolamento & purificação , Adulto , Feminino , Teste de Absorção do Anticorpo Treponêmico Fluorescente , Humanos , Luminescência , Gravidez , Resultado da Gravidez , Sorodiagnóstico da Sífilis , Treponema pallidum/imunologia
2.
Clin Chem ; 65(1): 170-179, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30518663

RESUMO

BACKGROUND: For transgender individuals taking hormone therapy (HT), data on laboratory values are limited, and the effects on laboratory values cannot be easily predicted. We evaluated the impact on common laboratory analytes in transgender individuals before and after initiation of HT. METHODS: We conducted a retrospective chart review of transgender patients identified at transgender-specific clinics at an urban county hospital and community clinic. Laboratory data were collected on hormone concentrations, hematologic parameters, electrolytes, lipids, and liver and renal markers before and after initiation of HT. RESULTS: We identified 183 transgender women (TW) and 119 transgender men (TM) for whom laboratory data were available. In all, 87 TW and 62 TM had baseline laboratory data, and data were also available for 133 TW and 89 TM on HT for >6 months. The most significant changes were seen in red blood cell count, hemoglobin concentration, hematocrit, and creatinine levels after >6 months of HT, which increased in TM and decreased in TW after HT (P < 0.005; d index > 0.6). Alkaline phosphatase, aspartate aminotransferase, and alanine aminotransferase levels increased in TM; however, the effect size was small (d index < 0.5). Calcium, albumin, and alkaline phosphatase levels significantly decreased in TW (P < 0.001; d > 0.6). Additionally, TM were found to have increased triglycerides and decreased HDL levels (P < 0.005; d > 0.6). CONCLUSIONS: Changes occur in several common laboratory parameters for patients on HT. Some laboratory values changed to match the gender identity, whereas others remained unchanged or were intermediate from the baseline values. These findings will help guide interpretation of laboratory test results in transgender patients taking HT.


Assuntos
Técnicas de Laboratório Clínico , Terapia de Reposição Hormonal , Pessoas Transgênero , Adulto , Feminino , Testes Hematológicos , Humanos , Testes de Função Renal , Testes de Função Hepática , Masculino , Estudos Retrospectivos
5.
J Biol Chem ; 288(31): 22576-83, 2013 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-23754276

RESUMO

A representative of a new class of potent antimalarials with an unknown mode of action was recently described. To identify the molecular target of this class of antimalarials, we employed a photo-reactive affinity capture method to find parasite proteins specifically interacting with the capture compound in living parasitized cells. The capture reagent retained the antimalarial properties of the parent molecule (ACT-213615) and accumulated within parasites. We identified several proteins interacting with the capture compound and established a functional interaction between ACT-213615 and PfMDR1. We surmise that PfMDR1 may play a role in the antimalarial activity of the piperazine-containing compound ACT-213615.


Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP/fisiologia , Antimaláricos/farmacologia , Plasmodium falciparum/fisiologia , Raios Ultravioleta , Animais
7.
Infect Control Hosp Epidemiol ; 43(11): 1719-1721, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-34247662

RESUMO

We observed a higher rate of blood-culture contamination during the COVID-19 pandemic at our institution compared to a prepandemic period. Given the potential implications of blood contamination in antibiotic and diagnostic test utilization as well as added cost, it is imperative to continue efforts to minimize these episodes during the pandemic.


Assuntos
COVID-19 , Pandemias , Humanos , Pandemias/prevenção & controle , SARS-CoV-2 , Hemocultura
8.
J Appl Lab Med ; 5(5): 889-896, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32483586

RESUMO

BACKGROUND: Detection of SARS-CoV-2 viral RNA is important for the diagnosis and management of COVID-19. METHODS: We present a clinical validation of a reverse transcription PCR (RT-PCR) assay for the SARS-CoV-2 nucleocapsid (N1) gene. Off-board lysis on an automated nucleic acid extraction system was optimized with endemic coronaviruses (OC43 and NL63). Genomic RNA and SARS-CoV-2 RNA in a recombinant viral protein coat were used as control materials and compared for recovery from nucleic acid extraction. RESULTS: Nucleic acid extraction showed decreased recovery of endemic Coronavirus in vitro transcribed RNA (NL63) compared with attenuated virus (OC43). SARS-CoV-2 RNA had more reliable recovery from extraction through amplification than genomic RNA. Recovery of genomic RNA was improved by combining lysis buffer with clinical matrix before adding RNA. The RT-PCR assay demonstrated 100% in silico sensitivity and specificity. The accuracy across samples was 100% (75 of 75). Precision studies showed 100% intra-run, inter-run, and inter-technologist concordance. The limit of detection was 264 copies per milliliter (estimated 5 copies per reaction; 35.56 mean threshold cycle value). CONCLUSIONS: This SARS-CoV-2 assay demonstrates appropriate characteristics for use under an Emergency Use Authorization. Endemic coronavirus controls were useful in optimizing the extraction procedure. In the absence of live or attenuated virus, recombinant virus in a protein coat is an appropriate control specimen type for assay validation during a pandemic.


Assuntos
Betacoronavirus , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Proteínas do Nucleocapsídeo , Pneumonia Viral/diagnóstico , Betacoronavirus/genética , Betacoronavirus/isolamento & purificação , COVID-19 , Teste para COVID-19 , Vacinas contra COVID-19 , Infecções por Coronavirus/terapia , Serviços Médicos de Emergência/métodos , Humanos , Proteínas do Nucleocapsídeo/análise , Proteínas do Nucleocapsídeo/genética , Pandemias , Pneumonia Viral/terapia , RNA Viral/análise , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2
9.
Am J Clin Pathol ; 151(5): 486-493, 2019 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-30715102

RESUMO

OBJECTIVES: To investigate biotin interference on three cardiac troponin (cTn) assays and demonstrate a method to overcome biotin interference. METHODS: cTn levels were measured in (1) plasma from healthy volunteers on 10-mg daily biotin supplementation mixed with a plasma with known elevated troponin, (2) plasmas with known elevated cTn after mixing in reagent biotin to simulate supplementation, and (3) biotin-spiked plasma specimens pretreated with streptavidin-agarose beads. RESULTS: Daily biotin ingestion (10 mg) and studies simulating daily biotin use resulted in significant interference in the Gen5 cardiac troponin T (cTnT) assay; the contemporary Gen 4 cTnT and high-sensitivity cardiac troponin I (hs-cTnI) assays were unaffected. The biotin interference threshold was 31, 315, and more than 2,000 ng/mL for Gen5 cTnT, cTnT, and hs-cTnI assays, respectively. Streptavidin pretreatment blocked biotin interference in cTn assays. CONCLUSIONS: Biotin interference is possible at plasma concentrations achievable by ingestion of over-the-counter supplements that may lead to delayed or missed diagnosis of myocardial injury with the Gen5 cTnT assay.


Assuntos
Biotina/sangue , Troponina T/sangue , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA