Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 605(7911): 659-662, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35614244

RESUMO

The possibility to accelerate electron beams to ultra-relativistic velocities over short distances by using plasma-based technology holds the potential for a revolution in the field of particle accelerators1-4. The compact nature of plasma-based accelerators would allow the realization of table-top machines capable of driving a free-electron laser (FEL)5, a formidable tool to investigate matter at the sub-atomic level by generating coherent light pulses with sub-ångström wavelengths and sub-femtosecond durations6,7. So far, however, the high-energy electron beams required to operate FELs had to be obtained through the use of conventional large-size radio-frequency (RF) accelerators, bound to a sizeable footprint as a result of their limited accelerating fields. Here we report the experimental evidence of FEL lasing by a compact (3-cm) particle-beam-driven plasma accelerator. The accelerated beams are completely characterized in the six-dimensional phase space and have high quality, comparable with state-of-the-art accelerators8. This allowed the observation of narrow-band amplified radiation in the infrared range with typical exponential growth of its intensity over six consecutive undulators. This proof-of-principle experiment represents a fundamental milestone in the use of plasma-based accelerators, contributing to the development of next-generation compact facilities for user-oriented applications9.

2.
Phys Rev Lett ; 133(3): 035001, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39094175

RESUMO

The space-charge field of a relativistic charged bunch propagating in plasma is screened due to the presence of mobile charge carriers. We experimentally investigate such screening by measuring the effect of dielectric wakefields driven by the bunch in a uncoated dielectric capillary where the plasma is confined. We show that the plasma screens the space-charge field and therefore suppresses the dielectric wakefields when the distance between the bunch and the dielectric surface is much larger than the plasma skin depth. Before full screening is reached, the effects of dielectric and plasma wakefields are present simultaneously.

3.
Phys Rev Lett ; 132(21): 215001, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38856283

RESUMO

We present a new approach that demonstrates the deflection and guiding of relativistic electron beams over curved paths by means of the magnetic field generated in a plasma-discharge capillary. We experimentally prove that the guiding is much less affected by the beam chromatic dispersion with respect to a conventional bending magnet and, with the support of numerical simulations, we show that it can even be made dispersionless by employing larger discharge currents. This proof-of-principle experiment extends the use of plasma-based devices, that revolutionized the field of particle accelerators enabling the generation of GeV beams in few centimeters. Compared to state-of-the-art technology based on conventional bending magnets and quadrupole lenses, these results provide a compact and affordable solution for the development of next-generation tabletop facilities.

4.
Phys Rev Lett ; 129(23): 234801, 2022 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-36563228

RESUMO

The breakthrough provided by plasma-based accelerators enabled unprecedented accelerating fields by boosting electron beams to gigaelectronvolt energies within a few centimeters [1-4]. This, in turn, allows the realization of ultracompact light sources based on free-electron lasers (FELs) [5], as demonstrated by two pioneering experiments that reported the observation of self-amplified spontaneous emission (SASE) driven by plasma-accelerated beams [6,7]. However, the lack of stability and reproducibility due to the intrinsic nature of the SASE process (whose amplification starts from the shot noise of the electron beam) may hinder their effective implementation for user purposes. Here, we report a proof-of-principle experiment using plasma-accelerated beams to generate stable and reproducible FEL light seeded by an external laser. FEL radiation is emitted in the infrared range, showing the typical exponential growth of its energy over six consecutive undulators. Compared to SASE, the seeded FEL pulses have energies 2 orders of magnitude larger and stability that is 3 times higher.

5.
Opt Lett ; 46(12): 2844-2847, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-34129555

RESUMO

Photoemission is one of the fundamental processes that describes the generation of charged particles from materials irradiated by photons. The continuous progress in the development of ultrashort lasers allows investigation into the dynamics of the process at the femtosecond timescale. Here we report about experimental measurements using two ultrashort ultraviolet laser pulses to temporally probe the electrons release from a copper cathode in a radio-frequency photoinjector. By changing their relative delay, we studied how the release mechanism is affected by two-photon photoemission when tens of GW/cm2 intensities are employed. We evaluated the limits it poses on the achievable beam brightness and analyzed the resulting emission yield in terms of the electronic temperature by modeling the cathode as a two-temperature system.

6.
Opt Lett ; 45(16): 4420-4423, 2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32796973

RESUMO

High-intensity ultrashort laser pulses interacting with thin solid targets are able to produce energetic ion beams by means of extremely large accelerating fields set by the energetic ejected electrons. The characterization of such electrons is thus important in view of a complete understanding of the acceleration process. Here, we present a complete temporal-resolved characterization of the fastest escaping hot electron component for different target materials and thicknesses, using temporal diagnostics based on electro-optical sampling with 100 fs temporal resolution. Experimental evidence of scaling laws for ultrafast electron beam parameters have been retrieved with respect to the impinging laser energy (0.4-4 J range) and to the target material, and an empirical law determining the beam parameters as a function of the target thickness is presented.

7.
Opt Lett ; 45(19): 5575-5578, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33001957

RESUMO

The interaction of an ultra-intense laser with a solid state target allows the production of multi-MeV proton and ion beams. This process is explained by the target normal sheath acceleration (TNSA) model, predicting the creation of an electric field on the target rear side, due to an unbalanced positive charge. This process is related to the emission of relativistic ultrafast electrons, occurring at an earlier time. In this work, we highlight the correlations between the ultrafast electron component and the protons by their simultaneous detection by means of an electro-optical sampling and a time-of-flight diagnostics, respectively, supported by numerical simulations showing an excellent agreement.

8.
Opt Express ; 24(26): 29512-29520, 2016 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-28059338

RESUMO

The interaction of a high-intensity short-pulse laser with thin solid targets produces electron jets that escape the target and positively charge it, leading to the formation of the electrostatic potential that in turn governs the ion acceleration. The typical timescale of such phenomena is on the sub-picosecond level. Here we show, for the first time, temporally-resolved measurements of the first released electrons that escaped from the target, so-called fast electrons. Their total charge, energy and temporal profile are provided by means of a diagnostics based on Electro-Optical Sampling with temporal resolution below 100 fs.

9.
Curr Oncol ; 23(3): e165-70, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27330353

RESUMO

BACKGROUND: Unlike cytotoxic agents, novel antineoplastic drugs can variably affect thyroid function and so impair patient outcomes. However, the widely used standard thyroid tests have demonstrated low sensitivity for detecting early thyroid damage that leads to dysfunction of the gland. To find a more reliable thyroid marker, we assessed the presence of antibodies binding thyroid hormones (thAbs) in a cancer population undergoing potentially thyrotoxic treatment. METHODS: From April 2010 to September 2013, 82 patients with hematologic malignancies treated with tyrosine kinase inhibitors or immunoregulatory drugs were recruited. Healthy volunteers (n = 104) served as control subjects. Thyroid function, autoimmunity tests, thAbs, and thyroid sonography were assessed once during treatment. RESULTS: Overall, thAb positivity was recorded in 13% of the entire cohort. In most cases, the thAbs were of a single type, with a predominance of T3 immunoglobulin G. More specifically, thAbs were detected in 11 cancer patients; and abnormal levels of thyroid-stimulating hormone, thyroglobulin antibody, and thyroperoxidase antibody were detected in 6 (p = 0.05), 0 (p = 0.0006), and 2 cancer patients (p = 0.001) respectively. Ultrasonographic alterations of the thyroid were observed in 12 cancer patients. In contrast, of the 104 healthy control subjects, only 1 was positive for thAbs (1%). CONCLUSIONS: We have demonstrated for the first time that thAbs are a reliable marker of early thyroid dysfunction when compared with the widely used standard thyroid tests. A confirmatory prospective trial aiming at evaluating thAbs at various time points during treatment could clarify the incidence and timing of antibody appearance.

10.
Phys Rev E ; 109(5-2): 055202, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38907494

RESUMO

Plasma wakefield acceleration represented a breakthrough in the field of particle accelerators by pushing beams to gigaelectronvolt energies within centimeter distances. The large electric fields excited by a driver pulse in the plasma can efficiently accelerate a trailing witness bunch paving the way toward the realization of laboratory-scale applications like free-electron lasers. However, while the accelerator size is tremendously reduced, upstream and downstream of it the beams are still handled with conventional magnetic optics with sizable footprints and rather long focal lengths. Here we show the operation of a compact device that integrates two active-plasma lenses with short focal lengths to assist the plasma accelerator stage. We demonstrate the focusing and energy gain of a witness bunch whose phase space is completely characterized in terms of energy and emittance. These results represent an important step toward the accelerator miniaturization and the development of next-generation table-top machines.

11.
Sci Rep ; 11(1): 3071, 2021 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-33542470

RESUMO

Time-Of-Flight (TOF) methods are very effective to detect particles accelerated in laser-plasma interactions, but they show significant limitations when used in experiments with high energy and intensity lasers, where both high-energy ions and remarkable levels of ElectroMagnetic Pulses (EMPs) in the radiofrequency-microwave range are generated. Here we describe a novel advanced diagnostic method for the characterization of protons accelerated by intense matter interactions with high-energy and high-intensity ultra-short laser pulses up to the femtosecond and even future attosecond range. The method employs a stacked diamond detector structure and the TOF technique, featuring high sensitivity, high resolution, high radiation hardness and high signal-to-noise ratio in environments heavily affected by remarkable EMP fields. A detailed study on the use, the optimization and the properties of a single module of the stack is here described for an experiment where a fast diamond detector is employed in an highly EMP-polluted environment. Accurate calibrated spectra of accelerated protons are presented from an experiment with the femtosecond Flame laser (beyond 100 TW power and ~ 1019 W/cm2 intensity) interacting with thin foil targets. The results can be readily applied to the case of complex stack configurations and to more general experimental conditions.

12.
Eur Rev Med Pharmacol Sci ; 24(9): 5162-5166, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32432781

RESUMO

OBJECTIVE: Over the ongoing pandemic of coronavirus disease 2019 (COVID-19), the demand for critical care beds among medical services has rapidly exceeded its supply. Elective surgery has comprehensively been drastically limited and allocating intensive care beds to emergency cases or to high risk scheduled elective cases has become an even more difficult task. Here we present our experience which could help to handle undelayable surgical procedures during this emergency. PATIENTS AND METHODS: In 2019, eight patients (4 men, 4 women) with a mean age of 88 years, needing emergency abdominal surgery underwent awake open surgery at our Department of Surgery. All of them were identified as fragile patients at preoperative evaluation by the anesthesiologist. In all cases, locoregional anesthesia (spinal, epidural or combined spinal-epidural anesthesia) was performed. Intraoperative and postoperative pain has been monitored and regularly assessed. RESULTS: None of the patients was intubated. Mean operative time was 80 minutes (minimum 30 minutes, maximum 130 minutes). Intraoperative and postoperative pain were both well controlled. None of them required postoperative intensive care support. No perioperative complications were observed. CONCLUSIONS: Based on our preliminary case series, awake open surgery has resulted feasible and safe. This approach has allowed to perform undelayable major abdominal surgeries on fragile patients when intensive care beds were not available. Surely, it represents a helpful alternative in the COVID-19 era. A streamlining of workflows would fast-track both fragile patients management, as well as healthcare workers' tasks and activity.


Assuntos
Anestesia Local/métodos , Infecções por Coronavirus , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Laparotomia , Pandemias , Pneumonia Viral , Vigília , Idoso de 80 Anos ou mais , Anestesia Epidural/métodos , Raquianestesia/métodos , Betacoronavirus , COVID-19 , Feminino , Humanos , Masculino , Duração da Cirurgia , Dor Pós-Operatória/terapia , Dor Processual/terapia , SARS-CoV-2
13.
Environ Pollut ; 256: 113388, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31662258

RESUMO

The most significant risk factor for organisms living in an environment contaminated by heavy metals is the metal bioavailability. Therefore, an efficient ecotoxicological approach to metal contamination is the measure of bioaccumulation level in target organisms. In this work, we characterized the heavy metal bioaccumulation in honey bees, Apis mellifera ligustica, collected at 35 sites from Umbria (Central Italy). The comparison of our data with selected Italian investigations revealed metal bioaccumulation in honey bee matrix of the same order of magnitude, with Cd showing a higher variability. To generalize the results, we developed a Honeybee Contamination Index (HCI) based on metal bioaccumulation in honey bees. An application of the HCI to the present dataset revealed cases of low (sixteen sites), intermediate (eighteen sites), and high (one site) metal contaminations. The comparison of HCI values from the Umbrian dataset with values calculated for other Italian and European metadata showed that most of the Umbrian sites fell in the portion of low and intermediate contamination conditions. HCI represented a reliable tool that provided a piece of concise information on metal contamination in terrestrial environments. Parallel to this effort, we have determined, the metal concentrations in the airborne particulate matter (PM10) at three regional background-monitoring stations in Umbria. These stations are representative of the average air quality of the areas of the investigated apiaries. A comparative analysis of metal enrichment factors in PM10, and honey bees suggested that the contamination in the bees was related to the PM10 values only to a minor extent. On the other side, a clear enrichment of metals such as Cd, Mn, Zn, and Cu in the honey bees appeared to depend on very local conditions and was probably related to the use of pesticides and fertilizers, and the resuspension of the locally contaminated soils and agriculture residues.


Assuntos
Abelhas/metabolismo , Bioacumulação , Monitoramento Ambiental/métodos , Poluentes Ambientais/análise , Metais Pesados/análise , Animais , Poluentes Ambientais/metabolismo , Itália , Metais Pesados/metabolismo , Praguicidas/análise , Praguicidas/metabolismo
14.
Mar Environ Res ; 159: 104955, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32250878

RESUMO

The study aimed at contributing to the knowledge of alternative stable states by evaluating the differences of mobile and sessile macro-zoobenthic assemblages between sea urchin barrens and macroalgal forests in coastal Mediterranean systems considering a large spatial scale. Six sites (100 s km apart) were selected: Croatia, Montenegro, Sicily (Italy), Sardinia (Italy), Tuscany (Italy), and Balearic Islands (Spain). A total of 531 taxa, 404 mobile and 127 sessile macro-invertebrates were recorded. Overall, 496 and 201 taxa were found in macroalgal forests and in barrens, respectively. The results of this large-scale descriptive study have met the expectation of lower macrofauna complexity and diversity in barrens rather than in macroalgal forests, and have allowed estimating the differences in levels of diversity and the consistency of variability across Mediterranean sites. Some peculiar patterns in barrens, related to both abundance of specific taxa and to high values of beta diversity, have been evidenced.


Assuntos
Ecossistema , Florestas , Animais , Biodiversidade , Croácia , Mar Mediterrâneo , Ouriços-do-Mar , Sicília , Espanha
15.
J Endocrinol Invest ; 32(5): 465-9, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19468262

RESUMO

BACKGROUND: Some growth factors and cytokines are known to cooperate with TSH in thyroid nodular growth, but few data are available on their circulating levels in Hashimoto's thyroiditis (HT). AIM: To evaluate in HT patients whether thyroid nodules are associated with variations in serum levels of hepatocyte growth factor (HGF) and interleukin-6 (IL-6). SUBJECTS AND METHODS: Serum levels of HGF and IL-6 were measured by enzyme-linked immunosorbent assay in 176 euthyroid subjects, subdivided into 4 groups: A) HT patients with nodular goiter (no.=42); B) non-goitrous HT patients (no.=36); C) non-HT patients with nodular goiter (no.=48), and D) healthy subjects without thyroid disease (no.=50). RESULTS: The highest concentrations of serumHGF were found in patients with nodular goiter, irrespective of the presence of associated HT (groups A and C). Nevertheless, in group A serum HGF levels were significantly higher than in group C (860.8+/-333.6 pg/ml vs 691.5+/-156 pg/ml, p<0.01). Moreover, though serum HGF levels in group B (578.3+/-217 pg/ml) were lower than in group A, they were significantly higher than in healthy controls (group D, 512.7+/-170.4 pg/ml, p<0.001). Serum IL-6 levels were similar in the two HT groups (A and B), and increased with respect to groups C and D. CONCLUSIONS: Serum HGF is increased in HT, especially associated to thyroid nodules, as compared with healthy non-goitrous individuals.


Assuntos
Bócio Nodular/sangue , Bócio Nodular/complicações , Doença de Hashimoto/sangue , Doença de Hashimoto/complicações , Fator de Crescimento de Hepatócito/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Saúde , Humanos , Interleucina-6/sangue , Masculino , Pessoa de Meia-Idade , Adulto Jovem
16.
Rev Sci Instrum ; 90(12): 123106, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893799

RESUMO

A novel technique of measuring the prompt, thermally induced wave-front aberrations in a large aperture flash-lamp pumped Nd3+ glass disk amplifier is presented. Implementing a 2 × 2 lens array and a 2 × 2 position sensitive detector array as a diagnostic system, the wave-front profile was successfully reconstructed for the first five Zernike terms for a temporal window of 8.5 ms.

17.
Sci Rep ; 8(1): 3243, 2018 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-29459758

RESUMO

The interaction of high-power ultra-short lasers with materials offers fascinating wealth of transient phenomena which are in the core of novel scientific research. Deciphering its evolution is a complicated task that strongly depends on the details of the early phase of the interaction, which acts as complex initial conditions. The entire process, moreover, is difficult to probe since it develops close to target on the sub-picosecond timescale and ends after some picoseconds. Here we present experimental results related to the fields and charges generated by the interaction of an ultra-short high-intensity laser with metallic targets. The temporal evolution of the interaction is probed with a novel femtosecond resolution diagnostics that enables the differentiation of the contribution by the high-energy forerunner electrons and the radiated electromagnetic pulses generated by the currents of the remaining charges on the target surface. Our results provide a snapshot of huge pulses, up to 0.6 teravolt per meter, emitted with multi-megaelectronvolt electron bunches with sub-picosecond duration and are able to explore the processes involved in laser-matter interactions at the femtosecond timescale.

18.
J Prev Med Hyg ; 48(1): 17-23, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17506233

RESUMO

INTRODUCTION: A multi-centre study has been conducted, during 2005, by means of a questionnaire posted on the Italian Society of Emergency Medicine (SIMEU) web page. Our intention was to carry out an organisational and functional analysis of Italian Emergency Departments (ED) in order to pick out some macro-indicators of the activities performed. Participation was good, in that 69 ED (3,285,440 admissions to emergency services) responded to the questionnaire. METHODS: The study was based on 18 questions: 3 regarding the personnel of the ED, 2 regarding organisational and functional aspects, 5 on the activity of the ED, 7 on triage and 1 on the assessment of the quality perceived by the users of the ED. RESULTS AND CONCLUSION: The replies revealed that 91.30% of the ED were equipped with data-processing software, which, in 96.83% of cases, tracked the entire itinerary of the patient. About 48,000 patients/year used the ED: 76.72% were discharged and 18.31% were hospitalised. Observation Units were active in 81.16% of the ED examined. Triage programmes were in place in 92.75% of ED: in 75.81% of these, triage was performed throughout the entire itinerary of the patient; in 16.13% it was performed only symptom-based, and in 8.06% only on-call. Of the patients arriving at the ED, 24.19% were assigned a non-urgent triage code, 60.01% a urgent code, 14.30% a emergent code and 1.49% a life-threatening code. Waiting times were: 52.39 min for non-urgent patients, 40.26 min for urgent, 12.08 for emergent, and 1.19 for life-threatening patients.


Assuntos
Serviço Hospitalar de Emergência/normas , Admissão do Paciente/estatística & dados numéricos , Qualidade da Assistência à Saúde , Serviço Hospitalar de Emergência/organização & administração , Pesquisas sobre Atenção à Saúde , Humanos , Itália , Triagem
19.
Sci Rep ; 6: 35000, 2016 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-27713541

RESUMO

Highly energetic electrons are generated at the early phases of the interaction of short-pulse high-intensity lasers with solid targets. These escaping particles are identified as the essential core of picosecond-scale phenomena such as laser-based acceleration, surface manipulation, generation of intense magnetic fields and electromagnetic pulses. Increasing the number of the escaping electrons facilitate the late time processes in all cases. Up to now only indirect evidences of these important forerunners have been recorded, thus no detailed study of the governing mechanisms was possible. Here we report, for the first time, direct time-dependent measurements of energetic electrons ejected from solid targets by the interaction with a short-pulse high-intensity laser. We measured electron bunches up to 7 nanocoulombs charge, picosecond duration and 12 megaelectronvolts energy. Our 'snapshots' capture their evolution with an unprecedented temporal resolution, demonstrat- ing a significant boost in charge and energy of escaping electrons when increasing the geometrical target curvature. These results pave the way toward significant improvement in laser acceleration of ions using shaped targets allowing the future development of small scale laser-ion accelerators.

20.
J Perinatol ; 35(9): 712-5, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26067471

RESUMO

OBJECTIVE: To report the prevalence of hypophosphatemia during the first week of life in preterm infants receiving aggressive parenteral nutrition and to analyze population variables associated with severe hypophosphatemia. STUDY DESIGN: A retrospective cohort of 61 neonates below 1250 g birth weight consecutively born at Hospital Italiano de Buenos Aires exposed to high caloric and protein intake from the first day of birth. Primary outcome was hypophosphatemia (phosphate <4 mg dl(-1)). A one-sample mean comparison test was used to compare our sample with a hypothesized population mean. RESULTS: The prevalence of hypophosphatemia was 91% (95% confidence interval (CI) 82 to 97%). The mean phosphatemia value was 2.52 mg dl(-1) (95% CI 2.18 to 2.86), significantly different from the hypothesized population mean (P<0.001). Patients with severe hypophosphatemia (<2 mg dl(-1)) were smaller. They presented with sepsis more frequently and received more vasoactive drugs and mechanical ventilation. CONCLUSION: The prevalence of hypophosphatemia in this group of preterm infants is high. The potential association with adverse clinical outcomes deserves further research.


Assuntos
Proteínas Alimentares , Hipofosfatemia , Doenças do Prematuro , Recém-Nascido Prematuro/metabolismo , Recém-Nascido de muito Baixo Peso/metabolismo , Nutrição Parenteral Total , Argentina/epidemiologia , Proteínas Alimentares/administração & dosagem , Proteínas Alimentares/efeitos adversos , Ingestão de Energia , Feminino , Humanos , Hipofosfatemia/diagnóstico , Hipofosfatemia/epidemiologia , Hipofosfatemia/etiologia , Hipofosfatemia/prevenção & controle , Recém-Nascido , Doenças do Prematuro/diagnóstico , Doenças do Prematuro/epidemiologia , Doenças do Prematuro/etiologia , Doenças do Prematuro/prevenção & controle , Masculino , Nutrição Parenteral Total/efeitos adversos , Nutrição Parenteral Total/métodos , Gravidez , Resultado da Gravidez/epidemiologia , Nascimento Prematuro/epidemiologia , Prevalência , Respiração Artificial/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Sepse/epidemiologia , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA