Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
J Clin Periodontol ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561985

RESUMO

AIM: To apply high-frequency ultrasound (HFUS) echo intensity for characterizing peri-implant tissues at healthy and diseased sites and to investigate the possible ultrasonographic markers of health versus disease. MATERIALS AND METHODS: Sixty patients presenting 60 implants diagnosed as healthy (N = 30) and peri-implantitis (N = 30) were assessed with HFUS. HFUS scans were imported into a software where first-order greyscale outcomes [i.e., mean echo intensity (EI)] and second-order greyscale outcomes were assessed. Other ultrasonographic outcomes of interest involved the vertical extension of the hypoechoic supracrestal area (HSA), soft-tissue area (STA) and buccal bone dehiscence (BBD), among others. RESULTS: HFUS EI mean values obtained from peri-implant soft tissue at healthy and diseased sites were 122.9 ± 19.7 and 107.9 ± 24.7 grey levels (GL); p = .02, respectively. All the diseased sites showed the appearance of an HSA that was not present in healthy implants (area under the curve = 1). The proportion of HSA/STA was 37.9% ± 14.8%. Regression analysis showed that EI of the peri-implant soft tissue was significantly different between healthy and peri-implantitis sites (odds ratio 0.97 [95% confidence interval: 0.94-0.99], p = .019). CONCLUSIONS: HFUS EI characterization of peri-implant tissues shows a significant difference between healthy and diseased sites. HFUS EI and the presence/absence of an HSA may be valid diagnostic ultrasonographic markers to discriminate peri-implant health status.

2.
Clin Oral Implants Res ; 35(6): 641-651, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38567801

RESUMO

OBJECTIVE: This in-vitro study assessed the influence of two intraoral scanning (IOS) protocols on the accuracy (trueness and precision) of digital scans performed in edentulous arches. METHODS: Twenty-two abutment-level master casts of edentulous arches with at least four implants were scanned repeatedly five times, each with two different scanning protocols. Protocol A (IOS-A) consisted of scanning the edentulous arch before inserting the implant scan bodies, followed by their insertion and its subsequent digital acquisition. Protocol B (IOS-B) consisted of scanning the edentulous arch with the scan bodies inserted from the outset. A reference scan from each edentulous cast was obtained using a laboratory scanner. Trueness and precision were calculated using the spatial fit analysis, cross-arch distance, and virtual Sheffield test. Statistical analysis was performed using generalized estimating equations (GEEs). Statistical significance was set at α = .05. RESULTS: In the spatial fit test, the precision of average 3D distances was 45 µm (±23 µm) with protocol IOS-A and 25 µm (±10 µm) for IOS-B (p < .001), and the trueness of average 3D distances was 44 µm (±24 µm) with protocol IOS-A and 24 µm (±7 µm) for IOS-B (p < .001). Cross-arch distance precision was 59 µm (±53 µm) for IOS-A and 41 µm (±43 µm) for IOS-B (p = .0035), and trueness was 64 µm (±47 µm) for IOS-A and 50 µm (±40 µm) for IOS-B (p = .0021). Virtual Sheffield precision was 286 µm (±198 µm) for IOS-A and 146 µm (±92 µm) for IOS-B (p < .001), and trueness was 228 µm (±171 µm) for IOS-A and 139 µm (±92 µm) for IOS-B (p < .001). CONCLUSIONS: The IOS-B protocol demonstrated significantly superior accuracy. Placement of scan bodies before scanning the edentulous arch is recommended to improve the accuracy of complete-arch intraoral scanning.


Assuntos
Imageamento Tridimensional , Humanos , Técnicas In Vitro , Imageamento Tridimensional/métodos , Implantes Dentários , Desenho Assistido por Computador , Arcada Edêntula/diagnóstico por imagem , Modelos Dentários , Arco Dental/diagnóstico por imagem , Arco Dental/anatomia & histologia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38613432

RESUMO

BACKGROUND: For over three decades, digital technologies have been used in Implant Dentistry, beginning with the introduction of planning software for Static Computer-Assisted Implant Surgery (S-CAIS). During this time, this field has witnessed the emergence of diverse methodologies and a proliferation of technological advancements. Today, S-CAIS is a widely adopted procedure for the placement of dental implants in both partially and fully edentulous patients, with Dynamic Computer-Assisted Surgery (D-CAIS) and Robotic-Assisted Implant Surgery (RAIS) rapidly gaining attention among dental professionals. The continuous advancements in this arena are not merely indicative of technological progress; they represent a steadfast dedication to refining precision, enhancing efficiency, and fostering innovation with the goal of optimizing patient outcomes in dental implantology. AIMS: The purpose of the following review is to meticulously examine the spectrum of digital technologies available and to describe their protocols, advantages, and shortcomings as well as to evaluate their accuracy in implant surgery in patients with complete edentulism. MATERIALS AND METHODS: A scoping review was performed following the Joanna Briggs Institute (JBI) protocols, leveraging the population, concept, and context (PCC) framework to construct the research question and determine the inclusion and exclusion criteria. RESULTS: Two hundred and sixty-seven records were identified for screening. After applying all the screening criteria, 41 articles were included for review and qualitative data analysis. DISCUSSION: S-CAIS, D-CAIS, and RAIS were identified as the main technologies for computer assisted implant surgery. Their applications, characteristics, protocols and levels of accuracy were compared and described. CONCLUSION: Taking into consideration the limitations of this study, S-CAIS appears to be the most applied and validated technology in implant surgery for fully edentulous patients followed by D-CAIS and RAIS being these last two promising initiatives in the field. Despite having similar levels of accuracy, the overall comparison showed a slightly higher values in RAIS followed by D-CAIS and S-CAIS.

4.
J Esthet Restor Dent ; 36(1): 207-219, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38018396

RESUMO

OBJECTIVE: To provide technical and clinical recommendations for implementing a digital workflow in Static Computer-Aided Implant Surgery in the anterior maxilla. CLINICAL CONSIDERATIONS: An optimal 3D implant position is crucial for achieving satisfying results in implant rehabilitation in the esthetic area. Due to its complexity, implant placement in the esthetic zone should be executed with precision and predictability. Static Computer-Aided Implant Surgery requires thorough planning and detailed attention to every step of the digital workflow protocol. CONCLUSIONS: Implant positioning in the esthetic zone using Static Computer-Aided Implant Surgery is a technique-sensitive procedure that requires precise execution of each step. This approach ensures accurate prosthetically driven 3D implant placement and prevents potential errors that could lead to inaccurate positioning. CLINICAL SIGNIFICANCE: The proper implementation of Static Computer-Aided Implant Surgery may increase the level of agreement between the planned and definitive implant 3D positions in the esthetic zone, thus enhancing the esthetic outcomes of implant rehabilitation.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Estética Dentária , Implantação Dentária Endóssea/métodos , Cirurgia Assistida por Computador/métodos , Maxila/cirurgia , Computadores , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico
5.
Clin Oral Implants Res ; 34(10): 1106-1117, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37485737

RESUMO

OBJECTIVES: To assess accuracy of intraoral optical scanning (IOS) and stereophotogrammetry (SPG), complete-arch digital implant impressions in vivo. MATERIALS AND METHODS: Consecutive patients needing implant-supported screw-retained zirconia complete-arch fixed-dental prostheses (ISZ-FDP) were recruited. For each patient, three impressions were taken: IOS, SPG (tests), and open-tray plaster (reference). Linear (ΔX, ΔY, and ΔZ), three-dimensional (ΔEUC), and angular deviations (ΔANGLE) were evaluated and stratified according to scanning technology for each implant. Potential effects of impression device (IOS and SPG), arch (maxilla and mandible), and implant number (4 and 6) were evaluated through multivariable analysis. Significance level was set at .05. RESULTS: A total of 11 complete arches (5 maxillae, 6 mandibles) in 11 patients were rehabilitated with ISZ-FDPs supported by 4 (n = 8) and 6 implants (n = 3). A total of 50 implants and 100 implant positions were captured by two investigated devices and compared to respective reference (mean ΔEUC IOS 137.2, SPG 87.6 µm; mean ΔANGLE 0.79, 0.38°). Differences between measurements (SPG-IOS) were computed for each implant, with negative values indicating better SPG accuracy. Significant mean ΔEUC difference of -49.60 µm (p = .0143; SD 138.15) and mean ΔANGLE difference of -0.40° (p < .0001; SD 0.65) were observed in favor of SPG. Multivariable analysis showed significant effect on ΔEUC (p = .0162) and ΔANGLE (p = .0001) only for impression devices, with SPG performing better. CONCLUSIONS: SPG experienced significantly higher linear and angular accuracy. No effect of type of arch or implant number was detected. Higher extreme deviations were experienced for IOS. SPG can be feasible for complete-arch digital impressions with caution, and rigid prototype try-in is recommended before screw-retained prosthesis manufacturing.

6.
Clin Oral Implants Res ; 34(5): 463-474, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36806171

RESUMO

OBJECTIVE: This study aims to report the implant survival rate of dental implants of partially dentate patients in the anterior mandible and the potential risk indicators for implant failure. MATERIALS AND METHODS: Patients with implant-supported restorations of single or multiple teeth in the anterior mandible restored with fixed partial implant-supported restorations were evaluated. Patient demographic data, implant placement timing, and loading protocol, biological and/or technical complications at the time of the last clinical and radiographic follow-up visit were registered. Survival rate, success rate, and potential risk indicators for implant failure were calculated. RESULTS: A total of 108 patients and 186 implants with a mean follow-up period of 5.48 years (0.1-11.34 years) were included. The 11.3-year cumulative survival rate was 90.9%. Immediate implant placement (OR = 2.75) (p = .08) and immediate implant loading (OR = 8.8) (p = .02*) indicated a higher risk of failure than late implant placement or loading. When combining both categories (type 1A), an OR = 10.59 (p = .04*) for implant failure was found compared to category 4C. Implants placed following static-computer-assisted implant surgery (S-CAIS) showed less risk of failure compared to freehand implant placement (OR = 0.18; 95% CI: 0.02-1.37) (p = .09). CONCLUSIONS: The survival rate of implants placed in the anterior mandible was considerably low (90.9%). S-CAIS, late placement, and conventional loading are protective factor against implant failure in the anterior mandible.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Humanos , Implantação Dentária Endóssea/métodos , Estudos Retrospectivos , Falha de Restauração Dentária , Prótese Dentária Fixada por Implante , Planejamento de Prótese Dentária , Carga Imediata em Implante Dentário/métodos , Mandíbula/cirurgia , Seguimentos
7.
Clin Oral Implants Res ; 34 Suppl 26: 304-348, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37750515

RESUMO

OBJECTIVES: The aim of this study was to review available evidence for Type 1A (immediate implant placement and immediate loading) of single tooth replacement in the maxillary esthetic zone. MATERIALS AND METHODS: An electronic search was conducted utilizing the databases of MEDLINE, Embase, and Cochrane to identify publications reporting on the outcomes of Type 1A for single tooth replacement in the maxillary esthetic zone. The success and survival rates of the included articles were reported, which were further categorized according to the clinical criteria reported in Type 1A. Mean survival rates were univariately compared between risk groups and additionally between studies published before and since 2012 using bias-corrected and study size-weighed bootstrap tests. A study time-correcting meta-analysis was then performed to obtain an overall effect for the study pool. RESULTS: A total of 3118 publications were identified in the search, with a total of 68 articles included. A mean number of implants per study were 37.2 and mean follow-up was 2.8 years. All the included studies utilizing Type 1A report highly selective inclusion and exclusion criteria. Univariate risk group comparison determined that studies before 2012 report a significantly lower mean survival rate (difference of -1.9 percentage points [PP], 95% CI: [-0.3, -4.0], p = .02), facial gap dimension had an impact on survival rates (+3.1 PP [0.2, 5.3] for width >2 mm, p = .04), as well as presence of endodontic infection (+2.6 PP [0.9, 5.1], p = .004). CONCLUSIONS: Type 1A has a high survival rate in studies reporting strict patient and site selection criteria. Further research is required to assess esthetic and functional success with Type 1A treatments.


Assuntos
Implantes Dentários , Humanos , Seleção de Pacientes , Estética Dentária , Bases de Dados Factuais
8.
Clin Oral Implants Res ; 34 Suppl 26: 266-303, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37750531

RESUMO

OBJECTIVES: The aim of this study was to assess the following PIO question: In adult patients treated with an indication for single tooth extraction in the maxillary esthetic zone (15-25), what is the influence of an immediate implant placement and immediate loading protocol on the clinical performance (primary aim) and esthetic outcomes (secondary aim) focusing on investigations published after 2010. MATERIAL AND METHODS: An electronic search in Medline (PubMed), the Cochrane Central Register of Controlled Trials, and EMBASE databases up to April 2022 was performed to identify clinical studies investigating the outcome of single implants subjected to immediate placement with immediate restoration/loading (Type 1A). RESULTS: Sixty-three studies (10 randomized controlled trials, 28 prospective and 25 retrospective cohort studies) were included with a follow-up ranging from 12 to 96 months. One thousand nine hundred sixty-one implants reported survival rates of 99.2 (98.6-99.5) % at 1 year, 97.5 (95.9-98.4) % after 3 years, and 95.8 (93.3-97.4) % after 5 years; 1064 immediately loaded restorations presented survival rates of 98.9 (97.8-99.5) % after 1 year, 96.8 (93.6-98.4) % after 2 years, and 94.8 (89.6-97.4) % after 5 years. Comparing baseline to 12-month data using the Hedges' g effect size (95% CI), papilla height presented an overall effect size of -0.71 (-1.25, -0.1) mm, midfacial recession change of -0.15 (-0.66, 0.36) mm, and a 0.82 (0.37, 1.28) gain in PES. CONCLUSIONS: Immediate implant placement and immediate loading can be considered a predictable and safe treatment option for single maxillary anterior restorations with adequate survival rates and favorable esthetics outcomes for up to 5 years.


Assuntos
Implantes Dentários , Adulto , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Estética Dentária , Bases de Dados Factuais
9.
J Esthet Restor Dent ; 35(7): 1058-1067, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37078683

RESUMO

OBJECTIVE: To describe a strategy using digital technologies for improving the diagnosis, treatment planning, and surgical execution of patients with excessive gingival display (EGD) due to altered passive eruption (APE). CLINICAL CONSIDERATIONS: An important component for successful patient's management is to fulfill their esthetic expectations whilst delivering predictable and long-term therapeutic outcomes. To achieve this goal in patients with excessive gingival display due to altered passive eruption, it is essential to perform an accurate diagnosis and to communicate to the patient the expected customized results using digital technologies. Computer-aided designed and manufactured multifunctional anatomical prototypes (MAPs) may contribute to these purposes. Additionally, they can guide the surgical crown lengthening procedure or serve as a reference during the surgical guide fabrication providing information of the required anatomical landmarks. CONCLUSIONS: This novel strategy protocol for diagnosis, communication, and treatment management of patients with excessive gingival display follows functional and biological principles within the frame of a digital workflow, which improves the diagnostic capabilities, enhances communication, and guides the surgical treatment as shown in the 12 months follow-up of the reported case. CLINICAL SIGNIFICANCE: Developing a virtual patient by combining multiple digital data sets including cone-beam computed tomography (CBCT), intra-oral scans and digital photography, supports the clinician and the patient to achieve a comprehensive diagnosis and to better communicate the expected results to the patient. Furthermore, this digital treatment exercise based on anatomical and biological principles will facilitate the surgical precision and the achievement of successful outcomes, thus fulfilling the patient needs and expectations.


Assuntos
Estética Dentária , Dente , Humanos , Gengiva , Coroa do Dente , Gengivectomia
10.
J Prosthet Dent ; 129(3): 395-399, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34229898

RESUMO

A method is described for the verification and correction of a digital scan of a complete arch implant-supported prosthesis for a completely edentulous patient. The technique provides an efficient way to integrate a highly accurate and precise scan of an implant index cast with a digital intraoral implant scan by using a computer-aided design and computer-aided manufacturing (CAD-CAM) software program. This method allows dental professionals to validate and, if necessary, correct the implant positions in the scan without the need for a conventional impression.


Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador
11.
J Prosthet Dent ; 2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37696747

RESUMO

STATEMENT OF PROBLEM: Because the use of zirconia in dentistry is relatively new, the number of published studies on the subject is scarce, even though material selection is an important factor in clinical performance. Therefore, a systematic assessment of the impact of the prosthetic material, framework design, veneering material, and manufacturing process is required. PURPOSE: The purpose of this systematic review and meta-analysis was to investigate the survival and success rates of feldspathic porcelain veneered zirconia (VZir) in comparison with monolithic zirconia (MZir) complete arch implant-supported prostheses (CAISPs). A secondary objective was to assess the influence of the type of loading, the presence or absence of a cantilever, the type of zirconia used, the location, and the opposing arch on complications rates and patient satisfaction. MATERIAL AND METHODS: An electronic search of the MEDLINE database (via PubMed), Scopus, Science Direct, Cochrane Library, and OpenGrey was carried out. The criteria described in the preferred reporting items for systematic reviews and meta-analyses statement were used. The search was restricted from January 2000 to January 2022. RESULTS: The systematic search resulted in 20 articles that met the established criteria. In total, 751 patients (VZir=302; MZir=449) with 3038 CAISPs (VZir=368; MZir=2670) were analyzed. Higher prosthetic survival and success rates were found in MZir compared with VZir CAISPs (100% and 95.45%, respectively). The meta-analysis found significantly fewer complications related to MZir (9.4% [4.8%-14.1%]) compared with VZir (33.7% [17.5%-49.9%]). CONCLUSIONS: Based on the findings of this systematic review, MZir CAISPs had higher survival and success rates than VZir CAISPs, with significantly fewer prosthetic complications. The influence of factors such as the type of functional loading, the presence of a cantilever, the material used in the prosthodontic workflow, the location of the CAISP, and the type of antagonist arch on the performance of Zir CAISPs remains unclear.

12.
J Prosthet Dent ; 2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36959002

RESUMO

Removal of cement-retained complete arch implant-supported zirconia restorations can be challenging. A predictable and minimally invasive technique combining cone beam computed tomography (CBCT) and intraoral scans with a virtual implant planning software program is described to identify the location of the screw access channels during the retrieval, thus minimizing damage to the existing restoration and allowing reuse.

13.
J Prosthet Dent ; 129(2): 276-292, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34281697

RESUMO

STATEMENT OF PROBLEM: Artificial intelligence applications are increasing in prosthodontics. Still, the current development and performance of artificial intelligence in prosthodontic applications has not yet been systematically documented and analyzed. PURPOSE: The purpose of this systematic review was to assess the performance of the artificial intelligence models in prosthodontics for tooth shade selection, automation of restoration design, mapping the tooth preparation finishing line, optimizing the manufacturing casting, predicting facial changes in patients with removable prostheses, and designing removable partial dentures. MATERIAL AND METHODS: An electronic systematic review was performed in MEDLINE/PubMed, EMBASE, Web of Science, Cochrane, and Scopus. A manual search was also conducted. Studies with artificial intelligence models were selected based on 6 criteria: tooth shade selection, automated fabrication of dental restorations, mapping the finishing line of tooth preparations, optimizing the manufacturing casting process, predicting facial changes in patients with removable prostheses, and designing removable partial dentures. Two investigators independently evaluated the quality assessment of the studies by applying the Joanna Briggs Institute Critical Appraisal Checklist for Quasi-Experimental Studies (nonrandomized experimental studies). A third investigator was consulted to resolve lack of consensus. RESULTS: A total of 36 articles were reviewed and classified into 6 groups based on the application of the artificial intelligence model. One article reported on the development of an artificial intelligence model for tooth shade selection, reporting better shade matching than with conventional visual selection; 14 articles reported on the feasibility of automated design of dental restorations using different artificial intelligence models; 1 artificial intelligence model was able to mark the margin line without manual interaction with an average accuracy ranging from 90.6% to 97.4%; 2 investigations developed artificial intelligence algorithms for optimizing the manufacturing casting process, reporting an improvement of the design process, minimizing the porosity on the cast metal, and reducing the overall manufacturing time; 1 study proposed an artificial intelligence model that was able to predict facial changes in patients using removable prostheses; and 17 investigations that developed clinical decision support, expert systems for designing removable partial dentures for clinicians and educational purposes, computer-aided learning with video interactive programs for student learning, and automated removable partial denture design. CONCLUSIONS: Artificial intelligence models have shown the potential for providing a reliable diagnostic tool for tooth shade selection, automated restoration design, mapping the preparation finishing line, optimizing the manufacturing casting, predicting facial changes in patients with removable prostheses, and designing removable partial dentures, but they are still in development. Additional studies are needed to further develop and assess their clinical performance.


Assuntos
Implantes Dentários , Prótese Parcial Removível , Dente , Humanos , Prostodontia , Inteligência Artificial , Assistência Odontológica
14.
J Prosthodont ; 32(S2): 150-164, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37586762

RESUMO

PURPOSE: To report the means to maximize the predictability and accuracy of intraoral digital implant scans through the evaluation of operator and patient-related factors. MATERIALS AND METHODS: A search of published articles related to factors that can decrease the scanning accuracy of intraoral digital implant scans was completed in four data sources:MEDLINE, EMBASE, EBSCO, and Web of Science. All studies related to variables that can influence the accuracy of intraoral digital implant scans obtained by using intraoral scanners (IOSs) were considered. These variables included ambient lighting, scanning pattern, implant scan body (ISB) design, techniques for splinting ISBs, arch location, implant position, and inter-implant distance. RESULTS: Among operator-related factors, ambient lighting conditions, scanning pattern, and ISB design (material, geometry, and retention design) can impact the accuracy of intraoral digital implant scans. The optimal ISB for maximizing IOS accuracy is unclear; however, polymer ISB can wear with multiple reuse and sterilization methods. Among patient-related factors, additional variables should be considered, namely arch (maxillary vs. mandibular arch), implant position in the arch, inter-implant distance, implant depth, and angulation. CONCLUSIONS: Ambient lighting conditions should be established based on the IOS selected to optimize the accuracy of intraoral digital implant scans. The optimal scanning pattern may vary based on the IOS, clinical situation, and the number of implants. The optimal ISB design may vary depending on the IOS used. Metallic implant scan bodies are preferred over polymer ISB designs to minimize wear due to multiple use and sterilization distortion. Among patient-related factors, additional variables should be considered namely the arch scanned, implant position in the arch, inter-implant distance, implant depth, and angulation. The impact of these factors may vary depending on the IOS selected.


Assuntos
Implantes Dentários , Humanos , Imageamento Tridimensional , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Modelos Dentários , Polímeros
15.
Clin Oral Implants Res ; 33(12): 1273-1281, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36239539

RESUMO

OBJECTIVES: Registration of intra-oral surface scans to cone beam computer tomography (CBCT) is critical in the digital workflow for static computer-aided implant surgery (sCAIS). This study aimed to assess the impact of CBCT field of view (FoV) on the precision of digital intra-oral scan registration. MATERIALS AND METHODS: Cone beam computer tomography data and intra-oral scans from 20 patients were included. Small FoV CBCT's were created by digitally segmenting a large FoV into three sextants. Virtual implant planning was performed. Digital intra-oral scans were repeatedly registered onto their corresponding large and small FoV CBCT datasets. The distances and angulations between the matching implant positions of each repeated registration were used to determine the precision of the registration process. Wilcoxon Signed Rank Paired Tests were used to compare the differences between large FoV and small FoV. The threshold for statistical significance was set at p = .05. RESULTS: Differences in 3D implant position based on the registration precision between small FoV and large FoV present at both the implant entry point (0.37 ± 0.25 mm vs 0.35 ± 0.23 mm, p = .482) and implant tip (0.49 ± 0.34 mm vs 0.37 ± 0.24 mm, p < .001). Differences in overall angular precision were observed between small FOV and large FoV (1.43 ± 1.36° vs 0.51 ± 0.38°, p < .001). CONCLUSION: CBCT with a small FoV is accompanied by greater precision errors in intra-oral scan registration. However, when sufficient well-distributed teeth are visible in small FoV CBCT, the precision of digital intra-oral scan registration appears to be within clinically acceptable limits for sCAIS.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantação Dentária , Boca , Cirurgia Assistida por Computador , Humanos , Implantação Dentária/métodos , Boca/diagnóstico por imagem
16.
J Prosthet Dent ; 127(4): 527-532, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33388152

RESUMO

This clinical report describes a completely digital workflow for the rehabilitation of the maxillary and mandibular arches with implant-supported fixed interim prostheses. Computer-assisted implant planning was used to fabricate a multifunctional surgical template for the guided placement of transitional and endosteal dental implants. Advantages of this technique include the integration of a completely digital workflow into the production of a virtual diagnostic tooth arrangement for edentulous patients, the planning of implant placement as per a restorative-driven approach, and the delivery of implant-supported fixed interim prostheses.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Dentição , Humanos , Fluxo de Trabalho
17.
J Prosthet Dent ; 2022 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-35431031

RESUMO

A method for the digital articulation of complete arch digital implant scans using the implant abutment prosthetic interfaces is described. This technique provides an effective and efficient method for articulating digital scans without the need for matching soft tissue references or fiduciary markers. This allows for a streamlined workflow with fewer intraoral scans and can provide a precise replication of the intaglio surface and emergence profile of an existing restoration.

18.
J Prosthet Dent ; 128(1): 42-48, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33602542

RESUMO

STATEMENT OF PROBLEM: The impact of discrepancies between casts produced from digital scans and conventional impressions on the clinical performance of definitive restorations has not been fully investigated. PURPOSE: The purpose of this crossover clinical trial was to evaluate the clinical performance of single implant-supported restorations fabricated with the digital scanning technique and computer-aided design and computer-aided manufacturing (CAD-CAM) casts compared with the conventional impression technique and gypsum casts in terms of efficiency, accuracy, and participant preference. MATERIAL AND METHODS: Thirty participants underwent conventional impressions and digital scans of a single implant-supported restoration. Two crowns were fabricated for the same implant with each technique. The time taken for each procedure was recorded. After the accuracy and efficiency analysis of both crowns, the better crown was delivered. A questionnaire was used to assess participant preference and comfort with the techniques. The Wilcoxon signed-rank test was used to compare the time measurements, and multiple comparisons were performed using the Bonferroni method. The chi-square test was used to compare the implant locations of delivered crowns (α=.05). RESULTS: The total time for the conventional impression technique was 14.16 minutes, while that for the digital scanning technique was significantly less at 11.28 minutes (P<.001). Remake times were 0.56 minutes for conventional impressions and 2.27 for digital scans, also significantly different (P<.001). The adjustment time taken in delivering the crowns was 4.35 minutes for conventional impressions and 3.78 minutes for conventional impressions, which was not statistically significant (P=.940). Of the crowns chosen for delivery, 46.7% were from conventional impressions and 53.3% from digital scans. Participants preferred the digital scanning technique (89%) to the conventional impression technique (11%). CONCLUSIONS: The digital scanning technique was more efficient than the conventional impression technique for single implant-supported restorations. Digital scans and CAD-CAM implant casts had accuracy comparable with that of conventional impressions and gypsum casts. Most participants preferred digital scans to conventional impressions.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Sulfato de Cálcio , Desenho Assistido por Computador , Estudos Cross-Over , Coroas , Materiais para Moldagem Odontológica , Planejamento de Prótese Dentária/métodos , Humanos
19.
J Prosthodont ; 31(S1): 38-46, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35313020

RESUMO

Static computer assisted implant surgery (s-CAIS) is an integral part of the digital workflow in implant dentistry and provides the link between the virtual planning environment and surgical field. The accuracy of s-CAIS is influenced by many cumulative factors including the fit of the template which is related to the manufacturing process. This critical review provides an overview of the current research on additively manufactured surgical implant guides.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Implantação Dentária Endóssea
20.
Clin Oral Implants Res ; 32(11): 1357-1365, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34423882

RESUMO

OBJECTIVES: This study aimed to determine whether distally angulating an implant is a successful strategy to avoid the maxillary sinus and the need for bone augmentation, while increasing the anterior-posterior (A-P) implant distribution in the edentulous maxilla. MATERIALS AND METHODS: In 115 patients with edentulous maxillae, virtual implant planning was performed utilizing cone-beam computer tomographs. Axial (8 mm length) and tilted (12 mm length) dental implants with 30-degree and 45-degree angulation were virtually positioned to avoid entering the maxillary sinus, while maximizing A-P distribution. Measurements were made between the tilted and axial implants to assess the change in A-P distribution of implants at the implant and abutment levels. RESULTS: Forty-seven sites (20.4%) were not able to have either treatment modality with insufficient bone for implant placement. Axial implants were placed more distally than 45-degree and 30-degree tilted implants in 24% and 42% of sites, respectively. The average change in A-P spread measured at the implant level, for 30- and 45-degree tilted implants was -0.25 mm (95% CI -0.76, 0.26) and 1.9 mm (95% CI 1.4, 2.3), respectively. When measured from the center of each multi-unit abutment the average increase in A-P distances for tilted implants appears larger in the 30-degree and 45-degree groups by 0.97 mm and 1.74 mm, respectively compared to measurements at the implant level. CONCLUSIONS: Angulating 12 mm implants provides a limited increase in A-P distribution of implants in edentulous rehabilitation in most situations. In certain patients, the use of 8mm axial implants may provide a greater A-P spread.


Assuntos
Implantes Dentários , Arcada Edêntula , Tomografia Computadorizada de Feixe Cônico Espiral , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Seguimentos , Humanos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Maxila/diagnóstico por imagem , Maxila/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA