Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
BMJ Open ; 11(12): e054550, 2021 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-35234659

RESUMO

INTRODUCTION: Personal digital devices that provide health information, such as the Apple Watch, have developed an increasing array of cardiopulmonary tracking features which have received regulatory clearance and are directly marketed to consumers. Despite their widespread and increasing use, data about the impact of personal digital device use on patient-reported outcomes and healthcare utilisation are sparse. Among a population of patients with atrial fibrillation and/or atrial flutter undergoing cardioversion, our primary aim is to determine the impact of the heart rate measurement, irregular rhythm notification, and ECG features of the Apple Watch on quality of life and healthcare utilisation. METHODS AND ANALYSIS: We are conducting a prospective, open-label multicentre pragmatic randomised clinical trial, leveraging a unique patient-centred health data sharing platform for enrolment and follow-up. A total of 150 patients undergoing cardioversion for atrial fibrillation or atrial flutter will be randomised 1:1 to receive the Apple Watch Series 6 or Withings Move at the time of cardioversion. The primary outcome is the difference in the Atrial Fibrillation Effect on QualiTy-of-life global score at 6 months postcardioversion. Secondary outcomes include inpatient and outpatient healthcare utilisation. Additional secondary outcomes include a comparison of the Apple Watch ECG and pulse oximeter features with gold-standard data obtained in routine clinical care settings. ETHICS AND DISSEMINATION: The Institutional Review Boards at Yale University, Mayo Clinic, and Duke University Health System have approved the trial protocol. This trial will provide important data to policymakers, clinicians and patients about the impact of the heart rate, irregular rhythm notification, and ECG features of widely used personal digital devices on patient quality of life and healthcare utilisation. Findings will be disseminated to study participants, at professional society meetings and in peer-reviewed journals. TRIAL REGISTRATION NUMBER: NCT04468321.


Assuntos
Fibrilação Atrial , Flutter Atrial , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Cardioversão Elétrica , Humanos , Estudos Multicêntricos como Assunto , Ensaios Clínicos Pragmáticos como Assunto , Estudos Prospectivos , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
J Am Heart Assoc ; 9(4): e013606, 2020 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-32063087

RESUMO

Background More than 600 000 coronary stents are implanted during percutaneous coronary interventions (PCIs) annually in the United States. Because no real-world surveillance system exists to monitor their long-term safety, claims data are often used for this purpose. The extent to which adverse events identified with claims data can be reasonably attributed to a specific medical device is uncertain. Methods and Results We used deterministic matching to link the NCDR (National Cardiovascular Data Registry) CathPCI Registry to Medicare fee-for-service claims for patients aged ≥65 years who underwent PCI with drug-eluting stents (DESs) between July 1, 2009 and December 31, 2013. We identified subsequent PCIs within 1 year of the index procedure in Medicare claims as potential safety events. We linked these subsequent PCIs back to the NCDR CathPCI Registry to ascertain how often the revascularization could be reasonably attributed to the same coronary artery as the index PCI (ie, target vessel revascularization). Of 415 306 DES placements in 368 194 patients, 33 174 repeat PCIs were identified in Medicare claims within 1 year. Of these, 28 632 (86.3%) could be linked back to the NCDR CathPCI Registry; 16 942 (51.1% of repeat PCIs) were target vessel revascularizations. Of these, 8544 (50.4%) were within a previously placed DES: 7652 for in-stent restenosis and 1341 for stent thrombosis. Of 16 176 patients with a claim for acute myocardial infarction in the follow-up period, 4446 (27.5%) were attributed to the same coronary artery in which the DES was implanted during the index PCI (ie, target vessel myocardial infarction). Of 24 288 patients whose death was identified in claims data, 278 (1.1%) were attributed to the same coronary artery in which the DES was implanted during the index PCI. Conclusions Most repeat PCIs following DES stent implantation identified in longitudinal claims data could be linked to real-world registry data, but only half could be reasonably attributed to the same coronary artery as the index procedure. Attribution among those with acute myocardial infarction or who died was even less frequent. Safety signals identified using claims data alone will require more in-depth examination to accurately assess stent safety.


Assuntos
Demandas Administrativas em Assistência à Saúde , Stents Farmacológicos , Medicare , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Idoso , Idoso de 80 Anos ou mais , Reestenose Coronária/mortalidade , Reestenose Coronária/terapia , Trombose Coronária/mortalidade , Trombose Coronária/terapia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/mortalidade , Vigilância de Produtos Comercializados , Sistema de Registros , Retratamento , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
4.
J Am Board Fam Med ; 30(2): 140-149, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28379820

RESUMO

INTRODUCTION: Embedded care managers are increasingly implemented as part of the care team within primary care practices, yet previous studies have indicated variability in acceptance by physicians and staff. This study assesses the acceptability of care managers among staff and physicians within the Michigan Primary Care Transformation (MiPCT) demonstration. METHODS: Care manager acceptance was measured using a web-based survey distributed to practices participating in the MiPCT demonstration. RESULTS: Both physicians and staff reported high levels of care manager acceptance. Longer length of care manager employment at the practice, higher care manager FTE dedicated to care management, and care manager employed by practice were all significantly associated with care manager acceptance. DISCUSSION: The MiPCT demonstration found high care manager acceptance across all care team members. The high level of acceptance may be due to the structures and processes developed by MiPCT to support implementation of care managers and the length of the intervention period. CONCLUSION: The MiPCT demonstration confirms that following three years of implementation, embedded care managers are acceptable to both physicians and staff within primary care practices. Importantly, embeddedness, or the amount of time care managers are located within practices, is associated with increased acceptance.


Assuntos
Pessoal Administrativo , Equipe de Assistência ao Paciente/organização & administração , Médicos/psicologia , Atenção Primária à Saúde/organização & administração , Adulto , Comportamento , Feminino , Humanos , Liderança , Masculino , Michigan , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem
5.
Med Devices (Auckl) ; 10: 165-188, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28860874

RESUMO

BACKGROUND: Machine learning methods may complement traditional analytic methods for medical device surveillance. METHODS AND RESULTS: Using data from the National Cardiovascular Data Registry for implantable cardioverter-defibrillators (ICDs) linked to Medicare administrative claims for longitudinal follow-up, we applied three statistical approaches to safety-signal detection for commonly used dual-chamber ICDs that used two propensity score (PS) models: one specified by subject-matter experts (PS-SME), and the other one by machine learning-based selection (PS-ML). The first approach used PS-SME and cumulative incidence (time-to-event), the second approach used PS-SME and cumulative risk (Data Extraction and Longitudinal Trend Analysis [DELTA]), and the third approach used PS-ML and cumulative risk (embedded feature selection). Safety-signal surveillance was conducted for eleven dual-chamber ICD models implanted at least 2,000 times over 3 years. Between 2006 and 2010, there were 71,948 Medicare fee-for-service beneficiaries who received dual-chamber ICDs. Cumulative device-specific unadjusted 3-year event rates varied for three surveyed safety signals: death from any cause, 12.8%-20.9%; nonfatal ICD-related adverse events, 19.3%-26.3%; and death from any cause or nonfatal ICD-related adverse event, 27.1%-37.6%. Agreement among safety signals detected/not detected between the time-to-event and DELTA approaches was 90.9% (360 of 396, k=0.068), between the time-to-event and embedded feature-selection approaches was 91.7% (363 of 396, k=-0.028), and between the DELTA and embedded feature selection approaches was 88.1% (349 of 396, k=-0.042). CONCLUSION: Three statistical approaches, including one machine learning method, identified important safety signals, but without exact agreement. Ensemble methods may be needed to detect all safety signals for further evaluation during medical device surveillance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA