Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Clin Microbiol ; 56(3)2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29305550

RESUMO

Zika virus (ZIKV) is a mosquito-borne flavivirus that is responsible for recent explosive epidemics in the Americas. Notably, ZIKV infection during pregnancy has been found to cause congenital birth defects, including microcephaly, and ZIKV has been associated with Guillain-Barré syndrome in adults. Diagnosis and surveillance of Zika in the Americas have been challenging due to similar clinical manifestations and extensive antibody cross-reactivity with endemic flaviviral diseases, such as dengue. We evaluated four serological and two reverse transcription-PCR (RT-PCR) methods in acute-phase (mean day, 1.8), early-convalescent-phase (mean day, 16.7), and late-convalescent-phase (mean, ~7 months) samples from the same individuals in a long-term pediatric cohort study in Nicaragua. Well-characterized samples from 301 cases of Zika, dengue, or non-Zika, nondengue febrile illnesses were tested. Compared to a composite reference, an in-house IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) and the NIAID-Biodefense and Emerging Infections (BEI) MAC-ELISA measuring IgM yielded sensitivities of 94.5% and 70.1% and specificities of 85.6% and 82.8%, respectively. The NS1 blockade-of-binding ELISA measuring anti-ZIKV NS1 antibody levels yielded sensitivities of 85.0% and 96.5% and specificities of 91.4% and 92.6% at early and late convalescence, respectively. An inhibition ELISA detecting total anti-ZIKV antibodies had sensitivity and specificity values of 68.3% and 58.3% for diagnosis and 94.0% and 98.6% for measuring annual infection incidence. Finally, the ZCD and Trioplex real-time RT-PCR assays detecting Zika, chikungunya, and dengue viruses both yielded a sensitivity of 96.1% and specificity of 100%. Together, these assays resolve the urgent need for diagnostic and surveillance tools for countries affected by Zika virus infections.


Assuntos
Monitoramento Epidemiológico , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , Testes Sorológicos/normas , Infecção por Zika virus/diagnóstico , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Reações Cruzadas , Dengue/diagnóstico , Dengue/epidemiologia , Vírus da Dengue/genética , Vírus da Dengue/imunologia , Vírus da Dengue/isolamento & purificação , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Humanos , Nicarágua/epidemiologia , Sensibilidade e Especificidade , Zika virus/genética , Zika virus/imunologia , Infecção por Zika virus/epidemiologia
2.
Rev Panam Salud Publica ; 41: e56, 2017 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-28902269

RESUMO

OBJECTIVE: To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua. METHODS: Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014-2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention's IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used. RESULTS: All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%-95.9%. CONCLUSION: Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease.


Assuntos
Anticorpos Antivirais/sangue , Febre de Chikungunya/diagnóstico , Vírus Chikungunya/imunologia , Febre de Chikungunya/sangue , Febre de Chikungunya/epidemiologia , Ensaio de Imunoadsorção Enzimática , Humanos , Nicarágua/epidemiologia , Vigilância da População , Testes Sorológicos
3.
Sci Transl Med ; 13(614): eabg9478, 2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34613812

RESUMO

Dengue virus serotypes 1 to 4 (DENV1­4) and Zika virus (ZIKV) are mosquito-borne flaviviruses that induce both virus-specific and broadly reactive antibodies. A first DENV infection is thought to induce antibodies that wane over 2 years to titers that can subsequently enhance severe dengue disease. Secondary DENV infection with a different serotype is thought to induce stable, cross-serotype protective antibodies. Low dengue disease incidence after the recent Zika pandemic led to the hypothesis that ZIKV infection is also transiently cross protective. We investigated antibody kinetics in 4189 children up to 11 years after one and multiple DENV and ZIKV infections in longitudinal cohorts in Nicaragua. We used a DENV inhibition enzyme-linked immunosorbent assay (iELISA), which measures antibodies associated with protection against dengue and Zika disease and with enhancement of dengue disease severity. Unexpectedly, we found that overall DENV iELISA titers stabilized by 8 months after primary DENV infection to a half-life longer than a human life and waned, although gradually, after secondary DENV infection. Similarly, DENV iELISA titers were stable or rose after primary ZIKV infection but declined in individuals with histories of DENV and ZIKV infection. In contrast, kinetics of anti-ZIKV antibodies after ZIKV infection were similar regardless of prior DENV immunity. We observed heterogeneity in DENV iELISA titer, suggesting that individual antibody titer set point, rather than waning, is important for future dengue disease risk. Together, these findings change our understanding of anti-flavivirus antibody kinetics and have implications for measuring vaccine efficacy and for predicting future dengue and Zika outbreaks.


Assuntos
Vírus da Dengue , Dengue , Infecção por Zika virus , Zika virus , Anticorpos Bloqueadores , Anticorpos Neutralizantes , Anticorpos Antivirais , Criança , Reações Cruzadas , Humanos
4.
PLoS Negl Trop Dis ; 10(6): e0004773, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27322692

RESUMO

Chikungunya is a viral disease transmitted by Aedes aegypti and Ae. albopictus mosquitoes. In late 2013, chikungunya virus (CHIKV) was introduced into the Caribbean island of St. Martin. Since then, approximately 2 million chikungunya cases have been reported by the Pan American Health Organization, and most countries in the Americas report autochthonous transmission of CHIKV. In Nicaragua, the first imported case was described in July 2014 and the first autochthonous case in September 2014. Here, we conducted two studies to analyze the seroprevalence of anti-CHIKV antibodies after the first chikungunya epidemic in a community-based cohort study (ages 2-14 years) and in a cross-sectional survey of persons aged ≥15 years in the same area of Managua, Nicaragua. Routine annual serum samples collected from 3,362 cohort participants in March/April 2014 and 2015, and 848 age-stratified samples collected from persons ≥15 years old at the end of May-beginning of June 2015 were used to estimate the seroprevalence of anti-CHIKV antibodies after the first epidemic (October 2014 to February 2015 in the study population). Using an Inhibition ELISA assay that measures total anti-CHIKV antibodies, the seroprevalence was significantly higher in those aged ≥15 (13.1% (95%CI: 10.9, 15.5)) than in the pediatric population (6.1% (95%CI: 5.3, 6.9)). The proportion of inapparent infections was 58.3% (95%CI: 51.5, 65.1) in children and 64.9% (95%CI: 55.2, 73.7) in the ≥15 study population. We identified age, water availability, household size, and socioeconomic status as factors associated with the presence of anti-CHIKV antibodies. Overall, this is the first report of CHIKV seropositivity in continental Latin America and provides useful information for public health authorities in the region.


Assuntos
Anticorpos Antivirais/sangue , Febre de Chikungunya/epidemiologia , Vírus Chikungunya/imunologia , Epidemias , Adolescente , Adulto , Febre de Chikungunya/imunologia , Febre de Chikungunya/virologia , Criança , Pré-Escolar , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nicarágua , Estudos Soroepidemiológicos , Fatores Socioeconômicos , Adulto Jovem
5.
Rev. panam. salud pública ; 41: e56, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-961706

RESUMO

ABSTRACT Objective To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua. Methods Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014-2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention's IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used. Results All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%-95.9%. Conclusion Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease.


RESUMEN Objetivo Elaborar y evaluar métodos serológicos para el diagnóstico y la investigación del chikungunya. Métodos Se elaboraron dos sistemas de ELISA de captura de IgM (MAC-ELISA por sus siglas en inglés) para el diagnóstico de la infección aguda por el virus de (CHIKV) y dos métodos de ELISA de inhibición (MEI) para determinar el valor cuantitativo de los anticuerpos totales contra el CHIKV, en el Laboratorio Nacional de Virología de Nicaragua en 2014-2015, para lo cual se utilizaron anticuerpos monoclonales (AcMo) y sueros hiperinmunes. Se determinó la sensibilidad, la especificidad y los valores predictivos, así como la concordancia de los MAC-ELISA, comparando los resultados de 198 muestras (116 positivas y 82 negativas) con el ELISA de los Centros para el Control y la Prevención de Enfermedades de los Estados Unidos (Atlanta; MAC-ELISA-CDC). Para la evaluación clínica de las cuatro técnicas serológicas, se emplearon 260 muestras de suero obtenidas en la fase aguda y en la fase de convalecencia de presuntos casos de chikungunya. Resultados Se estandarizaron los cuatro métodos analíticos determinando las concentraciones óptimas de los diferentes reactivos. La duración del procesamiento se redujo sustancialmente en comparación con el MAC-ELISA-CDC. Con los sistemas de MAC-ELISA, se obtuvo una sensibilidad del 96,6% y del 97,4% y una especificidad del 98,8% y del 91,5% al utilizar AcMo y suero hiperinmune, respectivamente, en comparación con el método de los CDC. La evaluación clínica de las cuatro técnicas serológicas, en comparación con la PCR en tiempo real de los CDC, arrojó una sensibilidad del 95,7% y una especificidad del 88,8%-95,9%. Conclusiones Se estandarizaron dos sistemas de ELISA-MAC y dos de MEI y se comprobó que poseen la calidad adecuada para el diagnóstico y las investigaciones del chikungunya, con lo cual mejorará la eficiencia de la vigilancia epidemiológica en Nicaragua, el primer país centroamericano que produce sus propios reactivos para el diagnóstico serológico del CHIKV. Los métodos estudiados en este trabajo pueden aplicarse en otros países y contribuyen al desarrollo de sistemas de diagnóstico sostenibles para combatir la enfermedad.


Assuntos
Vírus Chikungunya/imunologia , Febre de Chikungunya/diagnóstico , Febre de Chikungunya/epidemiologia , Anticorpos Antivirais/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Nicarágua/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA