Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am Heart J ; 269: 15-24, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38042457

RESUMO

BACKGROUND AND OBJECTIVE: Patients with palpitations clinically suggestive of paroxysmal supraventricular tachycardia (PSVT) are often managed conservatively until ECG-documentation of the tachycardia, leading to high impact on life quality and healthcare resource utilization. We evaluated results of electrophysiological study (EPS), and ablation when appropriate, among these patients, with special focus on gender differences in management. METHODS: BELIEVE SVT is a European multicenter, retrospective registry in tertiary hospitals performing EPS in patients with palpitations, without ECG-documentation of tachycardia or preexcitation, and considered highly suggestive of PSVT by a cardiologist or cardiac electrophysiologist. We analyzed clinical characteristics, results of EPS and ablation, complications, and clinical outcomes during follow-up. RESULTS: Six-hundred eighty patients from 20 centers were included. EPS showed sustained tachycardia in 60.9% of patients, and substrate potentially enabling AVNRT in 14.7%. No major/permanent complications occurred. Minor/transient complications were reported in 0.84% of patients undergoing diagnostic-only EPS and 1.8% when followed by ablation. During a 3.4-year follow-up, 76.2% of patients remained free of palpitations recurrence. Ablation (OR: 0.34, P < .01) and male gender (OR: 0.58, P = .01) predicted no recurrence. Despite a higher female proportion among patients with recurrence, (77.2% vs 63.5% among those asymptomatic during follow-up, P < .01), 73% of women in this study reported no recurrence of palpitations after EPS. CONCLUSIONS: EPS and ablation are safe and effective in preventing recurrence of nondocumented palpitations clinically suggestive of PSVT. Despite a lower efficacy, this strategy is also highly effective among women and warrants no gender differences in management.


Assuntos
Ablação por Cateter , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Masculino , Feminino , Estudos Retrospectivos , Carga de Sintomas , Taquicardia Paroxística/diagnóstico , Arritmias Cardíacas/cirurgia , Sistema de Registros
2.
Aten Primaria ; 56(2): 102782, 2024 Feb.
Artigo em Espanhol | MEDLINE | ID: mdl-37924621

RESUMO

OBJECTIVE: The objective was to develop a screening for heart disease detection in primary care, to identify pathological electrocardiographic changes and underlying heart disease in adolescents. DESIGN: The study was carried out for one year using multistage sampling. SITE: Primary care centers in a health area that had digital ECG equipment (12 centers) were selected. PARTICIPANTS: Initially, 718 (16.6%) 14-year-old adolescents were recruited and those with a previous diagnosis of heart disease were excluded. INTERVENTIONS: Screening consisted of including a health questionnaire in the mandatory 14-year-old check-up. MAIN MEASUREMENTS: Screening included a questionnaire, cardiac auscultation, ECG and echocardiography. Abnormality criteria were established to refer for a second evaluation by a cardiologist. RESULTS: Finally, the sample was made up of 698 adolescents, with a mean age of 13.7±0.5 years, and 354 (50.7%) were boys. A total of 149 (21.3%) were selected for a second review by cardiology: 88 (12.6%) due to a positive questionnaire, 11 (2.2%) due to abnormal cardiac auscultation, and 66 (9.5%) due to ECG findings. Adolescents with evidence of heart disease were 24 (3.4%). Of these, 14 (2.0%) had suggestive alterations and follow-up was recommended, 6 (0.9%) had a definitive diagnosis of heart disease, and 4 (0.6%) had other pathological findings related to the cardiovascular system. CONCLUSIONS: The screening allowed us to identify 1% of adolescents with heart disease and another 2% will remain in follow-up. The ECG detected more pathological cases than the questionnaire.


Assuntos
Morte Súbita Cardíaca , Cardiopatias , Masculino , Humanos , Adolescente , Feminino , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Cardiopatias/diagnóstico , Ecocardiografia , Programas de Rastreamento
3.
Europace ; 22(5): 704-715, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31840163

RESUMO

AIMS: Atrial electrical remodelling (AER) is a transitional period associated with the progression and long-term maintenance of atrial fibrillation (AF). We aimed to study the progression of AER in individual patients with implantable devices and AF episodes. METHODS AND RESULTS: Observational multicentre study (51 centres) including 4618 patients with implantable cardioverter-defibrillator +/-resynchronization therapy (ICD/CRT-D) and 352 patients (2 centres) with pacemakers (median follow-up: 3.4 years). Atrial activation rate (AAR) was quantified as the frequency of the dominant peak in the signal spectrum of AF episodes with atrial bipolar electrograms. Patients with complete progression of AER, from paroxysmal AF episodes to electrically remodelled persistent AF, were used to depict patient-specific AER slopes. A total of 34 712 AF tracings from 830 patients (87 with pacemakers) were suitable for the study. Complete progression of AER was documented in 216 patients (16 with pacemakers). Patients with persistent AF after completion of AER showed ∼30% faster AAR than patients with paroxysmal AF. The slope of AAR changes during AF progression revealed patient-specific patterns that correlated with the time-to-completion of AER (R2 = 0.85). Pacemaker patients were older than patients with ICD/CRT-Ds (78.3 vs. 67.2 year olds, respectively, P < 0.001) and had a shorter median time-to-completion of AER (24.9 vs. 93.5 days, respectively, P = 0.016). Remote transmissions in patients with ICD/CRT-D devices enabled the estimation of the time-to-completion of AER using the predicted slope of AAR changes from initiation to completion of electrical remodelling (R2 = 0.45). CONCLUSION: The AF progression shows patient-specific patterns of AER, which can be estimated using available remote-monitoring technology.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Desfibriladores Implantáveis , Marca-Passo Artificial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Pré-Escolar , Humanos
4.
Eur J Clin Invest ; 49(10): e13161, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31449685

RESUMO

BACKGROUND: Antiplatelet therapy (APT) use in combination with oral anticoagulation is common among patients with atrial fibrillation, but there is scarce information regarding its effect on outcomes in patients on non-vitamin K antagonist oral anticoagulants (NOAC). We aimed to evaluate the safety and efficacy of APT use in a 'real-world' cohort of nonvalvular atrial fibrillation (NVAF) patients initiating NOAC. DESIGN: We conducted a retrospective multicentre study including 2361 consecutive NVAF patients initiating NOAC between January 2013 and December 2016. Patients with an acute ischaemic event within the last 12 months (acute coronary syndrome, stroke or revascularization) were excluded. Patients were followed up, and all clinical events were recorded at 3 months. The primary outcome of the study was major bleeding, and the secondary outcomes were stroke, nonfatal myocardial infarction, intracranial bleeding and death. RESULTS: One hundred forty-five (6.1%) patients received concomitant APT, and aspirin was the more common (79%). At 3 months, 25 (1.1%) patients had major bleeding, 8 (0.3%) had nonfatal myocardial infarction, 7 (0.3%) had ischaemic stroke, and 40 (1.7%) died. After multivariate adjustment, concomitant APT was associated with higher risk for major bleeding (HR = 3.62, 95% CI 1.32-9.89; P = .012), but was not associated with a higher risk of other clinical outcomes. CONCLUSIONS: Concomitant APT use is uncommon among these patients and does not seem to be associated with lower rates of ischaemic events or death. However, there are signals for an increased risk of bleeding, which reinforces current guideline recommendations.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Antitrombinas/uso terapêutico , Aspirina/uso terapêutico , Fibrilação Atrial/complicações , Dabigatrana/uso terapêutico , Quimioterapia Combinada , Feminino , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Masculino , Mortalidade , Infarto do Miocárdio/epidemiologia , Modelos de Riscos Proporcionais , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Pirazóis/uso terapêutico , Piridinas/uso terapêutico , Piridonas/uso terapêutico , Estudos Retrospectivos , Rivaroxabana/uso terapêutico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Tiazóis/uso terapêutico
5.
J Electrocardiol ; 52: 99-100, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30529813

RESUMO

Autonomic regulation plays a role in the progression of heart failure with reduced ejection fraction (HrEF).Twenty-one HFrEF patients, 60.8 ±â€¯13.1 years, receiving angiotensin inhibition, were replaced by angiotensin receptor-neprilysin inhibitor (ARNI). A 24-hour Holter recording was performed before and after 3 months of the maximum tolerated dose of ARNi. We evaluated changes in autonomic tone using heart rate variability (SDNN, rMSSD, pNN50, LF, HF, LF/HF, α1, α2), and heart rate turbulence (TO and TS). ARNI was up-titrated to a maximum daily dose of 190 ±â€¯102 mg, 47.5% of the target dose. ARNI therapy was not associated with any improvement in any of the parameters related with heart rate variability or heart rate turbulence (p > 0.05 for all). ARNI use at lower than target doses did not improve autonomic cardiac tone as evaluated by 24-hour Holter monitoring.


Assuntos
Aminobutiratos/administração & dosagem , Antagonistas de Receptores de Angiotensina/administração & dosagem , Sistema Nervoso Autônomo/efeitos dos fármacos , Insuficiência Cardíaca/tratamento farmacológico , Tetrazóis/administração & dosagem , Compostos de Bifenilo , Relação Dose-Resposta a Droga , Combinação de Medicamentos , Eletrocardiografia Ambulatorial , Feminino , Determinação da Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Valsartana
6.
Eur J Clin Invest ; 48(6): e12907, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29423910

RESUMO

BACKGROUND: Clinical practice guidelines recommend regular kidney function monitoring in atrial fibrillation patients on nonvitamin K oral anticoagulants (NOAC); however, information regarding compliance with these recommendations in daily life conditions is scarce. We sought to determine the compliance with kidney function monitoring recommendations in nonvalvular atrial fibrillation (NVAF) patients starting NOAC and its implication on the appropriateness of NOAC dosage. MATERIAL AND METHODS: This study involves the retrospective analysis of a multicentre registry including consecutive NVAF patients who started NOAC (n = 692). Drug dosage changes and serum creatinine determinations were recorded during 1-year follow-up. European Heart Rhythm Association criteria were used to define the appropriateness of kidney function monitoring as well as adequate NOAC dosage. RESULTS: During the follow-up (334 ± 89 days), the compliance with kidney function monitoring recommendations was 61% (n = 425). After multivariate adjustment, age (OR × year: 0.92 (CI 95%: 0.89-0.95) P < .001), creatinine clearance (OR × mL/min: 1.02 (CI 95%: 1.01-1.03) P < .001) and adequate NOAC dosage at baseline (OR: 1.54 (CI 95%: 1.06-2.23), P = .024) were independent predictors of appropriate kidney function monitoring. Compliance with kidney function monitoring recommendations was independently associated with change to appropriate NOAC dose after 1 year (OR: 2.80 (CI 95%: 1.01-7.80), P = .049). CONCLUSIONS: Noncompliance with kidney function monitoring recommendations is common in NVAF patients starting NOAC, especially in elderly patients with kidney dysfunction. Compliance with kidney function monitoring recommendations was associated with adequate NOAC dosage at 1-year follow-up. Further studies are warranted to evaluate the implication of kidney function monitoring on prognosis.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/administração & dosagem , Fidelidade a Diretrizes/estatística & dados numéricos , Testes de Função Renal/estatística & dados numéricos , Sistema de Registros , Insuficiência Renal/diagnóstico , Acidente Vascular Cerebral/prevenção & controle , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Antitrombinas/administração & dosagem , Fibrilação Atrial/complicações , Creatinina/metabolismo , Dabigatrana/administração & dosagem , Monitoramento de Medicamentos , Feminino , Humanos , Masculino , Análise Multivariada , Razão de Chances , Guias de Prática Clínica como Assunto , Pirazóis/administração & dosagem , Piridonas/administração & dosagem , Insuficiência Renal/metabolismo , Estudos Retrospectivos , Rivaroxabana/administração & dosagem , Acidente Vascular Cerebral/etiologia
7.
Europace ; 18(9): 1328-34, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26566941

RESUMO

AIMS: Atrial fibrillation (AF) is associated with an increased morbidity and mortality after cardiac surgery. Von Willebrand factor (vWF) has been proposed as a biomarker of endothelial damage/dysfunction. We hypothesized that vWF levels could be used as valuable biomarker for AF occurrence after cardiac surgery. Moreover, we explored the potential association between vWF and tissue remodelling as possible implication in post-surgical AF. METHODS AND RESULTS: We prospectively recruited 100 consecutive patients who undergoing programmed cardiac surgery with cardiopulmonary bypass and with no previous history of AF. Plasma vWF levels were determined from citrated plasma samples. Right atrial appendage tissue was obtained during cardiac surgery, and vWF expression as well as interstitial fibrosis was analysed by immunostaining and Masson's trichrome, respectively. We found raised vWF plasma levels in ischaemic vs. valvular patients (200.2 ± 66.3 vs. 157.2 ± 84.3 IU/dL; P = 0.015). Fibrosis degree was associated with plasma vWF levels. Plasma vWF was an independent prognostic marker for AF development in ischaemic patients [odds ratio, OR 6.44 (95% confidence interval, CI 1.40-36.57), P = 0.035]. CONCLUSION: Plasma vWF levels are associated with tissue fibrosis in patients undergoing cardiac surgery and with post-surgical AF development in ischaemic patients. These findings suggest an association among vWF levels, atrial remodelling, and AF development. It is supported by higher vWF expression in right atrial tissue in ischaemic patients, who developed post-surgical AF.


Assuntos
Fibrilação Atrial/etiologia , Ponte de Artéria Coronária/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Isquemia Miocárdica/cirurgia , Fator de von Willebrand/metabolismo , Idoso , Apêndice Atrial/patologia , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Biomarcadores/sangue , Distribuição de Qui-Quadrado , Feminino , Fibrose , Doenças das Valvas Cardíacas/sangue , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Isquemia Miocárdica/sangue , Isquemia Miocárdica/diagnóstico , Razão de Chances , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Regulação para Cima
8.
J Cardiovasc Electrophysiol ; 26(7): 774-82, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25916814

RESUMO

INTRODUCTION: An empirical sequence of burst antitachycardia pacing (ATP) is effective in terminating fast ventricular tachycardias (FVT) in patients with implantable cardioverter-defibrillators (ICDs). We aimed to determine whether multiple ATP bursts for termination of FVT results in shock reduction compared to a single ATP burst. METHODS AND RESULTS: We analyzed data from the Umbrella trial, a multicenter prospective observational study of ICD patients followed by the CareLink Monitoring System. We compared the safety and effectiveness of a single ATP burst (Group 1) with a strategy of successive ATP sequences (Group 2) for termination of FVT episodes (cycle lengths 250-320 milliseconds) before shock therapy. Over a mean follow-up of 35 months, a total of 650 FVT episodes were detected in 154 patients (mean cycle length: 299 ± 18 milliseconds). Effectiveness of the first burst ATP in Group 1 was 73% and shocks were required in 27% of episodes. Effectiveness of the first burst ATP in Group 2 was 77%, and this increased to 91% with the third or successive ATP bursts. Shocks were required in 9% of episodes in group 2, representing a 67% reduction in the need of high-energy shocks. Median duration of FVT episodes and mortality in both groups were similar. Multivariate analysis indicated that programming multiple ATP bursts (OR 3.4, 95%CI 1.7-6.8, P = 0.001) was an independent predictor of ATP effectiveness. CONCLUSION: This study provides first evidence that a strategy of multiple burst ATP sequences for termination of FVT episodes leads to a clinically meaningful reduction in the need for shocks.


Assuntos
Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Traumatismos por Eletricidade/prevenção & controle , Taquicardia Ventricular/terapia , Potenciais de Ação , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Traumatismos por Eletricidade/diagnóstico , Traumatismos por Eletricidade/etiologia , Traumatismos por Eletricidade/fisiopatologia , Desenho de Equipamento , Falha de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Espanha , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 36(1): 31-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23078110

RESUMO

BACKGROUND: Biomarkers of necrosis and inflammation have been found raised after radiofrequency ablation (RF). There is scarce information on biomarkers' behavior after cryoablation. Our aim was to study biomarkers of necrosis, inflammation, and interstitial remodeling after two different approaches: RF versus cryoablation. METHODS: We studied 22 consecutive patients with atrial flutter who underwent RF (10) or cryoablation (12). All patients underwent electrophysiological study and subsequent ablation. Peripheral samples were collected before the procedure, immediately after, the following day, 3 days, 1 week, 1 month, and 2 months after ablation. Samples were assayed for biomarkers of inflammation (high sensitive C-reactive protein [hs-CRP]) and tissue remodeling (C-propeptide of type I procollagen [CICP], matrix metalloproteinase 2 [MMP-2], matrix metalloproteinase 9 [MMP-9], and metallopeptidase inhibitor 1 [TIMP-1]). We also determined biomarkers of tissue necrosis (creatine kinase [CK], its MB isoenzyme, cardiac troponin I [TnI], and troponin T (TnT)] in samples obtained immediately after ablation, 6 hours postablation, and 12 hours postablation. RESULTS: Bidirectional isthmus block was achieved in all patients. We found significantly higher levels of CK, CK-MB, and TnI after cryoablation compared to RF ablation for all timing samples. These necrosis biomarkers showed significant differences depending on the time (all P < 0.001), and the interaction between the time and the used ablation approach (P = 0.005, P < 0.001, and P < 0.001, respectively). For patients who undergoing RF ablation, MMP-2 showed the greatest changes depending on the interaction between time and number of applications (P = 0.041), whereas for patients who undergoing cryoablation, CK was the most relevant biomarker depending on the interaction between time and number of applications (P = 0.006). CONCLUSIONS: We show higher levels of necrosis and myocardial injury biomarker after cryoablation versus RF. However, we found higher remodeling processes after RF. Our data support previous publications showing different lesion formation in cryoablation and RF.


Assuntos
Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Mediadores da Inflamação/sangue , Miocárdio Atordoado/sangue , Miocárdio Atordoado/etiologia , Miocárdio/patologia , Idoso , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose/sangue , Necrose/etiologia , Necrose/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Cardiol J ; 30(4): 534-542, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34708863

RESUMO

BACKGROUND: Freezing rate of second-generation cryoballoon (CB) is a biophysical parameter that could assist pulmonary vein isolation. The aim of this study is to assess freezing rate (time to reach -30°C ([TT-30C]) as an early predictor of acute pulmonary vein isolation using the CB. METHODS: Biophysical data from CB freeze applications within a multicenter, nation-wide CB ablation registry were gathered. Successful application (SA), was defined as achieving durable intraprocedural vein isolation. And SA with time to isolation under 60 s (SA-TTI<60) as achieving durable vein isolation in under 60 s. Logistic regressions were performed and predictive models were built for the data set. RESULTS: 12,488 CB applications from 1,733 atrial fibrillation (AF) ablation procedures were included within 27 centers from a Spanish CB AF ablation registry. SA was achieved in 6,349 of 9,178 (69.2%) total freeze applications, and SA-TTI<60 was obtained in 2,673 of 4,784 (55.9%) freezes where electrogram monitoring was present. TT-30C was shorter in the SA group (33.4 ± 9.2 vs 39.3 ± 12.1 s; p < 0.001) and SA-TTI<60 group (31.8 ± 7.6 vs. 38.5 ± 11.5 s; p < 0.001). Also, a 10 s increase in TT-30C was associated with a 41% reduction in the odds for an SA (odds ratio [OR] 0.59; 95% confidence interval [CI] 0.56-0.63) and a 57% reduction in the odds for achieving SA-TTI<60 (OR 0.43; 95% CI 0.39-0.49), when corrected for electrogram visualization, vein position, and application order. CONCLUSIONS: Time to reach -30°C is an early predictor of the quality of a CB application and can be used to guide the ablation procedure even in the absence of electrogram monitoring.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Fatores de Tempo , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Recidiva
11.
Cardiol J ; 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36908163

RESUMO

BACKGROUND: Ablation of atrial fibrillation (AF), both cryoablation ablation (CBA) and radiofrequency catheter ablation (RFCA), have demonstrated to be safe and effective. About 1 in 3 patients may face a redo due to recurrence and the best technique is unknown. The aim of this study is to assess the efficacy of CBA as a repeat procedure in patients with prior CBA or RFCA. METHODS: A nation-wide CBA registry (RECABA) was analyzed and patients were compared who had previously undergone CBA (Prior-CB) or RFCA (Prior-RF). The primary endpoint was AF recurrence at 12 months after a 3-month blanking period. A survival analysis was performed, univariate and multivariate Cox models were also built. RESULTS: Seventy-four patients were included. Thirty-three (44.6%) were in the Prior-CB group and 41 (55.4%) in the Prior-RF. There were more reconnected pulmonary veins in the Prior-RF than in Prior-CB group (40.4% vs.16.5%, p = 0.0001). The 12-month Kaplan-Meier estimate of freedom from AF recurrence after the blanking period was 61.0% (95% confidence interval [CI] 41.4-75.8%) in the Prior-CB, and 89.2% (95% CI 73.6-95.9%) in the Prior-RF group (p = 0.002). Multivariate Cox regression pointed Prior-CB as the sole independent predictor of AF recurrence, with an adjusted HR of 2.67 (95% CI 1.05-6.79). CONCLUSIONS: Repeat CBA shows higher rates of AF recurrences compared to CBA after a previous RFCA despite presenting less reconnected veins at the procedure. These data suggest that patients with AF recurrence after CBA may benefit from other ablation techniques after a recurrence. RECABA is registered at clinicaltrials.gov with the Unique Identifier NCT02785991.

12.
J Clin Med ; 11(5)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35268259

RESUMO

Introduction: Cryoballoon ablation (CBA) has become a standard treatment for paroxysmal atrial fibrillation (PaAF) but limited data is available for outcomes in patients with persistent atrial fibrillation (PeAF). Methods: We analyzed the first 944 patients included in the Spanish Prospective Multi-center Observation Post-market Registry to compare characteristics and outcomes of patients undergoing CBA for PeAF versus PaAF. Results: A total of 944 patients (57.8 ± 10.4 years; 70.1% male) with AF (27.9% persistent) were prospectively included from 25 centers. PeAF patients were more likely to have structural heart disease (67.7 vs. 11.4%; p < 0.001) and left atrium dilation (72.6 vs. 43.3%; p < 0.001). CBA of PeAF was less likely to be performed under general anesthesia (10.7 vs. 22.2%; p < 0.001), with an arterial line (32.2 vs. 44.6%; p < 0.001) and assisted transeptal puncture (11.9 vs. 17.9%; p = 0.025). During an application, PeAF patients had a longer time to −30 °C (35.91 ± 14.20 vs. 34.93 ± 12.87 s; p = 0.021) and a colder balloon nadir temperature during vein isolation (−35.04 ± 9.58 vs. −33.61 ± 10.32 °C; p = 0.004), but received fewer bonus freeze applications (30.7 vs. 41.1%; p < 0.001). There were no differences in acute pulmonary vein isolation and procedure-related complications. Overall, 76.7% of patients were free from AF recurrences at 15-month follow-up (78.9% in PaAF vs. 70.9% in PeAF; p = 0.09). Conclusions: Patients with PeAF have a more diseased substrate, and CBA procedures performed in such patients were more simplified, although longer/colder freeze applications were often applied. The acute efficacy/safety profile of CBA was similar between PaAF and PeAF patients, but long-term results were better in PaAF patients.

13.
J Card Fail ; 17(9): 735-41, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21872143

RESUMO

BACKGROUND: Heart rate turbulence (HRT) is associated with risk in chronic heart failure (CHF). The objective of this study was to assess the short-term variability of HRT and to compare the diagnostic yield of 7-day (7DH) versus 24-hour (1DH) Holter monitoring for calculating HRT in a CHF population. METHODS AND RESULTS: Forty-nine consecutive patients with CHF were studied. At inclusion, 7DH was performed to evaluate the variability of HRT parameters. For categorized analyses, turbulence onset (TO) ≥0% and turbulence slope (TS) ≤2.5 ms/RR were defined as abnormal, and patients were classified into subgroups based on the number of abnormal HRT parameters.The cumulative percentage of patients with calculable HRT increased from 69.4% with 1DH to 93.9% with 7DH. The intraclass correlation coefficients across the 7-day monitoring were 0.81 (95% confidence interval [CI] 0.70-0.89) for TO and 0.90 (95% CI 0.84-0.95) for TS. When comparing 2 randomly selected days, TO and TS values were similar (P > .1) and showed a strong correlation (TO: r = 0.79; TS: r = 0.84: P < .001). Bland-Altman plots showed a mean difference of 0.31% (95% CI -0.07 to 0.70) for TO and 0.44 ms/RR (95% CI -1.37 to 0.48) for TS. In contrast, categorized analyses showed that up to 16% of patients changed their HRT subgroup score from day 1 to day 2 of comparison. CONCLUSIONS: In this population, 7DH significantly increased the percentage of patients with calculable HRT parameters. The short-term variability of the quantitative HRT values was good, but when patients were categorized into the established HRT subgroups, the concordance was suboptimal.


Assuntos
Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Adulto , Doença Crônica , Estudos de Coortes , Eletrocardiografia Ambulatorial/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
14.
J Am Heart Assoc ; 10(1): e018108, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33356406

RESUMO

Background Large-scale studies describing modern populations using an implantable cardioverter-defibrillator (ICD) are lacking. We aimed to analyze the incidence of arrhythmia, device interventions, and mortality in a broad spectrum of real-world ICD patients with different heart disorders. Methods and Results The UMBRELLA study is a prospective, multicenter, nationwide study of contemporary patients using an ICD followed up by remote monitoring, with a blinded review of arrhythmic episodes. From November 2005 to November 2017, 4296 patients were followed up. After 46.6±27.3 months, 16 067 episodes of sustained ventricular arrhythmia occurred in 1344 patients (31.3%). Appropriate ICD therapy occurred in 27.3% of study population. Patients with ischemic cardiomyopathy (hazard ratio [HR], 1.51; 95% CI, 1.29-1.78), dilated cardiomyopathy (HR, 1.28; 95% CI, 1.07-1.53), and valvular heart disease (HR, 1.94; 95% CI, 1.43-2.62) exhibited a higher risk of appropriate ICD therapies, whereas patients with hypertrophic cardiomyopathy (HR, 0.72; 95% CI, 0.54-0.96) and Brugada syndrome (HR, 0.25; 95% CI, 0.14-0.45) showed a lower risk. All-cause death was 13.4% at follow-up. Ischemic cardiomyopathy (HR, 3.09; 95% CI, 2.58-5.90), dilated cardiomyopathy (HR, 3.33; 95% CI, 2.18-5.10), and valvular heart disease (HR, 3.97; 95% CI, 2.25-6.99) had the worst prognoses. Delayed high-rate detection was enabled in 39.7% of patients, and single-zone programming occurred in 52.6% of primary prevention patients. Both parameters correlated with lower risk of first appropriate ICD therapy, with no excess risk of mortality. The rate of inappropriate shocks at follow-up was low (6%) and did not differ among type of ICD but was lower in SmartShock-capable devices. Conclusions Irrespective of the cause, contemporary ICD patients with heart failure-related disorders had a similar risk of ICD life-saving interventions and death. Current ICD programming recommendations still need to be implemented. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NTC01561144.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Taquicardia Ventricular , Estudos de Coortes , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/classificação , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Cardioversão Elétrica/estatística & dados numéricos , Análise de Falha de Equipamento , Feminino , Cardiopatias/classificação , Cardiopatias/complicações , Cardiopatias/mortalidade , Cardiopatias/terapia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Avaliação das Necessidades , Serviços Preventivos de Saúde/métodos , Serviços Preventivos de Saúde/estatística & dados numéricos , Medição de Risco , Espanha/epidemiologia , Análise de Sobrevida , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia
15.
Sci Rep ; 11(1): 17268, 2021 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-34446764

RESUMO

Cryoablation is safe and effective for the treatment of atrial fibrillation (AF) in controlled clinical trials, but contemporary real-world usage and outcomes are limited. The Report of the Spanish Cryoballoon Ablation Registry (RECABA) was designed to evaluate acute and 12-month outcomes of cryoballoon ablation for the treatment of AF in Spain. Patients from 27 Spanish centers were prospectively enrolled. Patients were treated with cryoballoon ablation and managed according to standard of care protocols at each center. The primary endpoint was ≥ 30 s freedom from AF at 12-month after a 3-month blanking period. Secondary endpoints included a description of patient characteristics, cryoablation procedural strategy and safety, and predictors of efficacy. In total, 1742 patients (71.4% PAF, 68.8% male, mean age 58.02 ± 10.40 years, 76.1% overweight or obese, CHA2DS2-VASc index 1.40 ± 1.28) were enrolled. Patients received 7.2 ± 2.67 cryo-applications. PV potentials could be detected in 61% of the PVs during ablation, with a mean time to block of 52.9 ± 37.02 s. Acute PVI was observed in 97% of PVs with 75.8% isolated with the first cryo-application. Mean procedural time was 113 ± 41 min. Acute complications occurred in 4.4% of the cases. With follow-up in 1628 patients, AF-free survival was 78.5% (PAF: 80.6% vs PersAF 73.3%; p < 0.001). Left atrium enlargement, female sex, non-PAF, and early recurrence were independent predictors of AF recurrence (p < 0.05). RECABA provides detailed insight into current dosing practices and demonstrates cryoablation is safe and effective in real-world use.ClinicalTrials.gov number: NCT02785991.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Estudos Prospectivos , Recidiva , Espanha , Fatores de Tempo , Adulto Jovem
17.
Rev Esp Salud Publica ; 942020 May 27.
Artigo em Espanhol | MEDLINE | ID: mdl-32458822

RESUMO

OBJECTIVE: The implantation of the Implantable Cardioverter Defibrillator (ICD) influences the psychological adjustment and the degree of subjective discomfort. The objective of this work was to analyze differences in psychological adjustment, fear of shocks and the degree of subjective discomfort derived from the illness depending on the reasons for implantation (primary vs secondary). METHODS: A sample of 82 patients with an ICD, for primary (58.5%) or secondary (41.5%) prevention indications was studied. A sociodemographic and clinical questionnaire and List of Brief Symptoms (LBS-50) was used. Descriptive univariate and bivariate analysis, t-tests on mean differences for independent samples and z-tests on proportion differences were performed. RESULTS: Regarding psychological adjustment, 43.9% of the patients reported to have sleeping disorder, regardless the type of prevention. A greater percentage of patients of primary prevention had scored higher in clinical scales. The 29.4% of patients with secondary prevention reported to be afraid of experiencing some shock. The 25% of patients whose type of prevention was primary showed severe or moderate level of subjective discomfort derived from the illness compared with the 14.7% of the secondary prevention patients (p=0.7). CONCLUSIONS: The patients with an ICD show symptoms clinically significant in Psychoactivity, Obsession-Compulsion, Anxiety, Somatization, Sleeping disorders and Psychopathology Risk Index. Both groups, regardless the type of prevention showed a similar psychological adjustment. Regarding the fear of shocks and the degree of subjective discomfort derived from the illness, no statistically significant differences between the groups were found.


OBJETIVO: La implantación del Desfibrilador Automático Implantado (DAI) influye en el ajuste psicológico y en el grado de malestar de los pacientes. El objetivo de este trabajo fue analizar las diferencias en el ajuste psicológico, el miedo a las descargas y el grado de malestar subjetivo derivado de la enfermedad en función del motivo de implantación (primaria frente a secundaria). METODOS: La muestra fue de 82 pacientes portadores de un DAI, tanto por prevención primaria (58,5%) como secundaria (41,5%). Se utilizó un cuestionario sociodemográfico y clínico, así como el Listado de Síntomas Breves (LSB­50). Se realizaron análisis descriptivos univariados y bivariados, pruebas t de diferencias entre medias y pruebas z de diferencias entre proporciones. RESULTADOS: Respecto al ajuste psicológico, el 43,9% de los pacientes refirió tener alteraciones del sueño, independientemente del tipo de prevención. Un mayor porcentaje de pacientes de prevención primaria mostraron puntuaciones altas en escalas clínicas. El 29,4% de los pacientes de prevención secundaria mostró miedo a sufrir alguna descarga. El 25% de los pacientes cuyo motivo de implantación fue primario indicó un nivel moderado o intenso en cuanto al malestar subjetivo derivado de la enfermedad, comparado con el 14,7% de los pacientes de prevención secundaria (p=0,7). CONCLUSIONES: Los pacientes con DAI presentan síntomas clínicamente relevantes en Psicoreactividad, Obsesión-compulsión, Ansiedad, Somatización, Alteraciones del sueño y el Índice de riesgo psicopatológico. Independientemente del tipo de prevención ambos grupos muestran un ajuste psicológico similar. No se encuentran diferencias entre los grupos ni en el miedo a las descargas ni en el grado de malestar subjetivo.


Assuntos
Desfibriladores Implantáveis , Adaptação Psicológica , Ajustamento Emocional , Humanos , Prevenção Primária , Prevenção Secundária , Espanha , Inquéritos e Questionários
18.
Heart Rhythm ; 17(7): 1084-1091, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32113896

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) carries an increased risk of sudden death due to ventricular arrhythmias (VAs). The implantable cardioverter-defibrillator (ICD) is a well-established therapy for treatment of VA. Monomorphic ventricular tachycardias (MVTs) are frequent in HCM patients and suitable for antitachycardia pacing (ATP) termination. OBJECTIVE: The purpose of this study was to describe ventricular tachycardia (VT) characteristics in a population of HCM patients with ICD and to study the effectiveness and safety of ATP for MVT. METHODS: Data were obtained from the multicenter prospective observational UMBRELLA trial, which included all patients with HCM and ICD followed by the CareLink Monitoring System. All episodes of VA were collected and analyzed. ATP effectiveness and safety were described, and factors related to ATP effectiveness were studied with generalized estimating equation (GEE) models. RESULTS: Among 251 patients followed for 47 months, 67 (26.7%) were implanted as secondary prevention. Fifty-six patients presented 326 episodes of VA (286 [87%] MVT). Mean cycle length was 312 ± 64 ms. Among 264 MVTs that received ICD therapy, 202 (76.5%) were ATP terminated. The first ATP burst was effective in 169 episodes (68.4%), and overall effectiveness of the first or second ATP burst was 73.8%. Multivariate GEE-adjusted analysis showed 2 variables related to ATP effectiveness: programming fast VT zone On vs Off (odds ratio [OR] 2.4; 95% confidence interval [CI] 1.5-5.2; P = .03) and programming ≥2 ATP bursts vs 1 burst only (OR 1.6; 95% CI 1.2-3.4; P = .04; and OR 2.9; 95% CI 1.8-6.3; P = .02; respectively). CONCLUSION: MVT is the predominant VA in HCM patients with ICD. ATP is highly effective in terminating the majority of MVTs, and its proved effectiveness should guide device selection and programming in order to avoid unnecessary high-energy shocks.


Assuntos
Cardiomiopatia Hipertrófica/terapia , Desfibriladores Implantáveis , Prevenção Secundária/métodos , Choque Cardiogênico/prevenção & controle , Taquicardia Ventricular/terapia , Cardiomiopatia Hipertrófica/complicações , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Choque Cardiogênico/etiologia , Taquicardia Ventricular/complicações , Resultado do Tratamento
19.
J Geriatr Cardiol ; 17(3): 141-148, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32280330

RESUMO

BACKGROUND: The identification of modifiable bleeding risk factors may be of relevance. The aim is to evaluate if aortic stenosis (AS) provides additional information to bleeding risk scores for predicting major bleeding (MB) in non-valvular atrial fibrillation (AF). METHODS: We designed a retrospective multi-center study including 2880 consecutive non-valvular AF patients initiating oral anticoagulation between January 2013 and December 2016. AS was defined as moderate or severe according to European echocardiography guidelines criteria. HASBLED, ATRIA and ORBIT scores were used to evaluate the bleeding risk. MB was defined according to the International Society on Thrombosis and Haemostasia criteria and registered at 18 months of follow-up. RESULTS: 168 (5.8%) patients had AS. Patients with AS had higher risk for MB compared to those without AS (HR = 2.13, 95% CI: 1.40-3.23, P < 0.001). Patients without AS and low-intermediate bleeding risk (0 points) showed the lowest MB rate, whereas the MB rate observed among patients with AS and high bleeding risk (2 points) was the highest one. Discrimination and reclassification analyses showed that AS provided additional information to bleeding risk scores for predicting MB at 18 months of follow-up. CONCLUSIONS: In this population, AS was associated with an increased risk for MB at midterm follow-up. The three scoring systems showed a moderate discriminatory ability for MB. Moreover, the addition of AS was associated with a significant improvement in their predictive accuracy. We suggest that the presence of this valvulopathy should be taken into account for bleeding risk assessment.

20.
J Clin Med ; 8(11)2019 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-31684004

RESUMO

Atrial fibrillation (AF) is a sustained cardiac arrhythmia associated with stroke, heart failure, and related health conditions. Though easily diagnosed upon presentation in a clinical setting, the transient and/or intermittent emergence of AF episodes present diagnostic and clinical monitoring challenges that would ideally be met with automated ambulatory monitoring and detection. Current approaches to address these needs, commonly available both in smartphone applications and dedicated technologies, combine electrocardiogram (ECG) sensors with predictive algorithms to detect AF. These methods typically require extensive preprocessing, preliminary signal analysis, and the integration of a wide and complex array of features for the detection of AF events, and are consequently vulnerable to over-fitting. In this paper, we introduce the application of symbolic recurrence quantification analysis (SRQA) for the study of ECG signals and detection of AF events, which requires minimal pre-processing and allows the construction of highly accurate predictive algorithms from relatively few features. In addition, this approach is robust against commonly-encountered signal processing challenges that are expected in ambulatory monitoring contexts, including noisy and non-stationary data. We demonstrate the application of this method to yield a highly accurate predictive algorithm, which at optimal threshold values is 97.9% sensitive, 97.6% specific, and 97.7% accurate in classifying AF signals. To confirm the robust generalizability of this approach, we further evaluated its performance in the implementation of a 10-fold cross-validation paradigm, yielding 97.4% accuracy. In sum, these findings emphasize the robust utility of SRQA for the analysis of ECG signals and detection of AF. To the best of our knowledge, the proposed model is the first to incorporate symbolic analysis for AF beat detection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA