Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Cogn Neuropsychiatry ; 28(3): 181-195, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36924343

RESUMO

INTRODUCTION: Patients with schizophrenia differ from healthy controls in the extent that they spontaneously take another's perspective. For such effects, it is difficult to separate the influence of schizophrenia from multiple potential confounders. Here, for the first time, associations between spontaneous perspective-taking and schizotypy were investigated in a nonclinical population. METHODS: Adult participants completed both a Schizotypal Personality Questionnaire (SPQ-BRU) and a novel online adaptation of a visual perspective-taking task that required participants to make judgements both from their own perspective and that of a human avatar. RESULTS: Response times were elevated when the avatar's perspective was inconsistent with that of the participant, providing evidence of spontaneous perspective-taking. This demonstrates that the visual perspective-taking task can be successfully implemented in an online format. However, schizotypy did not predict these spontaneous perspective-taking effects. CONCLUSIONS: Unlike explicit mentalising, this form of implicit mentalising is not affected by nonclinical manifestations of schizotypy traits. This implies that impairment of general neurocognitive function contributes to altered spontaneous perspective-taking in schizophrenia. A novel account based on the cognitive control processes involved in perspective selection and the role of attention in perspective calculation reconciles apparently contradictory findings of earlier studies comparing patients with schizophrenia and healthy controls.


Assuntos
Esquizofrenia , Transtorno da Personalidade Esquizotípica , Adulto , Humanos , Transtorno da Personalidade Esquizotípica/psicologia , Tempo de Reação/fisiologia , Personalidade , Atenção
2.
Psychol Res ; 85(1): 214-222, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31300874

RESUMO

Drinking water is important for health and there is an agreement that drinking water facilitates certain cognitive processes. However, the mechanism underlying the effect of drinking water on cognition is unknown. While attention performance is improved by even a very small drink, memory performance seems to require larger drinks for performance enhancement. This suggests that attention could be affected earlier in the drinking process than memory. We aimed to elucidate further the mechanism involved by investigating the stage during the drinking process influencing performance on cognitive tasks. To this end, we compared mouth rinsing and mouth drying. Mouth rinsing was expected to result in improved attention performance and would suggest that the mechanism responsible is located in the mouth and occurs early in the drinking process, before swallowing. Eighty-seven adults participated in either a treatment (mouth rinsing or mouth drying) or control (no intervention) condition. They were assessed at baseline and 20 min later after intervention on measures of visual attention, short-term memory, subjective thirst and mood. Our results showed that mouth rinsing improved visual attention, but not short-term memory, mood or subjective thirst. Mouth drying did not affect performance. Our results support the hypothesis that different mechanisms underlie the effect of drinking water on different cognitive processes. They suggest that merely sipping water, as opposed to having a large drink, can improve attention.


Assuntos
Atenção/fisiologia , Água Potável , Ingestão de Líquidos/fisiologia , Memória de Curto Prazo/fisiologia , Sede/fisiologia , Adulto , Afeto , Cognição/fisiologia , Desidratação/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Boca , Adulto Jovem
3.
J Biol Chem ; 293(22): 8394-8409, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29618516

RESUMO

High-mobility group box 1 (HMGB1) is a chromatin-associated protein that, in response to stress or injury, translocates from the nucleus to the extracellular milieu, where it functions as an alarmin. HMGB1's function is in part determined by the complexes (HMGB1c) it forms with other molecules. However, structural modifications in the HMGB1 polypeptide that may regulate HMGB1c formation have not been previously described. In this report, we observed high-molecular weight, denaturing-resistant HMGB1c in the plasma and peripheral blood mononuclear cells of individuals with systemic lupus erythematosus (SLE) and, to a much lesser extent, in healthy subjects. Differential HMGB1c levels were also detected in mouse tissues and cultured cells, in which these complexes were induced by endotoxin or the immunological adjuvant alum. Of note, we found that HMGB1c formation is catalyzed by the protein-cross-linking enzyme transglutaminase-2 (TG2). Cross-link site mapping and MS analysis revealed that HMGB1 can be cross-linked to TG2 as well as a number of additional proteins, including human autoantigens. These findings have significant functional implications for studies of cellular stress responses and innate immunity in SLE and other autoimmune disease.


Assuntos
Autoantígenos/metabolismo , Proteínas de Ligação ao GTP/metabolismo , Proteína HMGB1/metabolismo , Leucócitos Mononucleares/metabolismo , Lúpus Eritematoso Sistêmico/metabolismo , Transglutaminases/metabolismo , Autoantígenos/imunologia , Células Cultivadas , Proteínas de Ligação ao GTP/imunologia , Proteína HMGB1/imunologia , Humanos , Leucócitos Mononucleares/imunologia , Lúpus Eritematoso Sistêmico/imunologia , Lúpus Eritematoso Sistêmico/patologia , Peso Molecular , Proteína 2 Glutamina gama-Glutamiltransferase , Especificidade por Substrato , Transglutaminases/imunologia
4.
Exp Brain Res ; 235(2): 555-563, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27812749

RESUMO

Mismatch negativity (MMN) has been characterised as a 'pre-attentive' component of an event-related potential (ERP) that is related to discrimination and error prediction processes. The aim of the current experiment was to establish whether visual MMN could be recorded to briefly presented, backward and forward masked visual stimuli, given both below and above levels of subjective experience. Evidence of visual MMN elicitation in the absence of the ability to consciously report stimuli would provide strong evidence for the automaticity of the visual MMN mechanism. Using an oddball paradigm, two stimuli that differed in orientation from each other, a + and an ×, were presented on a computer screen. Electroencephalogram (EEG) was recorded from nine participants (six females), mean age 21.4 years. Results showed that for stimuli that were effectively masked at 7 ms presentation, there was little variation in the ERPs evoked to standard and deviant stimuli or in the subtraction waveform employed to delineate the visual MMN. At 14 ms stimulus presentation, when participants were able to report stimulus presence, an enhanced negativity at around 175 and 305 ms was observed to the deviant and was evident in the subtraction waveform. However, some of the difference observed in the ERPs can be attributed to stimulus characteristics, as the use of a 'lonely' deviant protocol revealed attenuated visual MMN components at 14 ms stimulus presentation. Overall, results suggest that some degree of conscious attention is required before visual MMN components emerge, suggesting visual MMN is not an entirely pre-attentive process.


Assuntos
Variação Contingente Negativa/fisiologia , Potenciais Evocados Visuais/fisiologia , Mascaramento Perceptivo/fisiologia , Adolescente , Adulto , Eletroencefalografia , Feminino , Humanos , Masculino , Estimulação Luminosa , Tempo de Reação/fisiologia , Fatores de Tempo , Adulto Jovem
5.
Psychol Res ; 81(2): 480-489, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26902293

RESUMO

Spatial perspective-taking that involves imagined changes in one's spatial orientation is facilitated by vestibular stimulation inducing a congruent sensation of self-motion. We examined further the role of vestibular resources in perspective-taking by evaluating whether aberrant and conflicting vestibular stimulation impaired perspective-taking performance. Participants (N = 39) undertook either an "own body transformation" (OBT) task, requiring speeded spatial judgments made from the perspective of a schematic figure, or a control task requiring reconfiguration of spatial mappings from one's own visuo-spatial perspective. These tasks were performed both without and with vestibular stimulation by whole-body Coriolis motion, according to a repeated measures design, balanced for order. Vestibular stimulation was found to impair performance during the first minute post stimulus relative to the stationary condition. This disruption was task-specific, affecting only the OBT task and not the control task, and dissipated by the second minute post-stimulus. Our experiment thus demonstrates selective temporary impairment of perspective-taking from aberrant vestibular stimulation, implying that uncompromised vestibular resources are necessary for efficient perspective-taking. This finding provides evidence for an embodied mechanism for perspective-taking whereby vestibular input contributes to multisensory processing underlying bodily and social cognition. Ultimately, this knowledge may contribute to the design of interventions that help patients suffering sudden vertigo adapt to the cognitive difficulties caused by aberrant vestibular stimulation.


Assuntos
Julgamento , Orientação/fisiologia , Desempenho Psicomotor/fisiologia , Percepção Espacial/fisiologia , Adulto , Humanos , Imaginação/fisiologia , Masculino , Percepção de Movimento/fisiologia , Vestíbulo do Labirinto/fisiologia
6.
Appetite ; 108: 464-470, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27825957

RESUMO

Water supplementation has been found to facilitate visual attention and short-term memory, but the dose required to improve performance is not yet known. We assessed the dose response effect of water on thirst, mood and cognitive performance in both adults and children. Participants were offered either no water, 25 ml or 300 ml water to drink. Study 1 assessed 96 adults and in Study 2, data are presented from 60 children aged 7-9 years. In both studies, performance was assessed at baseline and 20 min after drinking (or no drink); on thirst and mood scales, letter cancellation and a digit span test. For both children and adults, a large drink (300 ml) was necessary to reduce thirst, while a small drink (25 ml) was sufficient to improve visual attention (letter cancellation). In adults, a large drink improved digit span, but there was no such effect in children. In children, but not adults, a small drink resulted in increased thirst ratings. Both children and adults show dose-response effects of drinking on visual attention. Visual attention is enhanced by small amounts of fluid and appears not to be contingent on thirst reduction. Memory performance may be related to thirst, but differently for children and adults. These contrasting dose-response characteristics could imply cognitive enhancement by different mechanisms for these two domains.


Assuntos
Afeto/fisiologia , Cognição/fisiologia , Ingestão de Líquidos , Adolescente , Adulto , Atenção/fisiologia , Criança , Feminino , Humanos , Masculino , Memória de Curto Prazo/fisiologia , Sede/fisiologia , Adulto Jovem
7.
Mol Microbiol ; 97(3): 472-87, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25908396

RESUMO

Haem is a life supporting molecule that is ubiquitous in all major kingdoms. In Staphylococcus aureus, the importance of haem is highlighted by the presence of systems both for the exogenous acquisition and endogenous synthesis of this prosthetic group. In this work, we show that in S. aureus the formation of haem involves the conversion of coproporphyrinogen III into coproporphyrin III by coproporphyrin synthase HemY, insertion of iron into coproporphyrin III via ferrochelatase HemH, and oxidative decarboxylation of Fe-coproporphyrin III into protohaem IX by Fe-coproporphyrin oxidase/dehydrogenase HemQ. Together, this route represents a transitional pathway between the classic pathway and the more recently acknowledged alternative biosynthesis machinery. The role of the haem biosynthetic pathway in the survival of the bacterium was investigated by testing for inhibitors of HemY. Analogues of acifluorfen are shown to inhibit the flavin-containing HemY, highlighting this protein as a suitable target for the development of drugs against S. aureus. Moreover, the presence of a transitional pathway for haem biosynthesis within many Gram positive pathogenic bacteria suggests that this route has the potential not only for the design of antimicrobials but also for the selective discrimination between bacteria operating different routes to the biosynthesis of haem.


Assuntos
Vias Biossintéticas/genética , Heme/biossíntese , Staphylococcus aureus/genética , Staphylococcus aureus/metabolismo , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Inibidores Enzimáticos/metabolismo , Enzimas/genética , Enzimas/metabolismo , Viabilidade Microbiana
8.
Phys Imaging Radiat Oncol ; 29: 100541, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38327762

RESUMO

Background and Purpose: Surface Guided Radiotherapy (SGRT) for head and neck radiotherapy is challenging as obstructions are common and non-rigid facial motion can compromise surface accuracy. The purpose of this work was to develop and benchmark the Remove the Mask (RtM) SGRT system, an open-source system especially designed to address the challenges faced in radiotherapy of head and neck cancer. Materials and Methods: The accuracy of the RtM SGRT system was benchmarked using a head phantom positioned on a robotic motion platform capable of sub-millimetre accuracy which was used to induce unidirectional shifts and to reproduce three real head motion traces. We also assessed the accuracy of the system in ten humans volunteers. The ground truth motion of the volunteers was obtained using a commercial motion capture system with an accuracy < 0.3 mm. Results: The mean tracking error of the RtM SGRT system for the ten volunteers was of -0.1 ± 0.4 mm -0.6 ± 0.6 mm and 0.3 ± 0.2 mm, and 0.0 ± 0.2° 0.0 ± 0.1° and 0.0 ± 0.2° for translations and rotations along the left-right, superior-inferior and anterior-posterior axes respectively and we also found similar results in measurements with the head phantom. Forced facial motion was associated with lower tracking accuracy. The RtM SGRT system achieved submillimetre accuracy. Conclusion: The RtM SGRT system is a low-cost, easy to build and open-source SGRT system that can achieve an accuracy that meets international commissioning guidelines. Its open-source and modular design allows for the development and easy translation of novel surface tracking techniques.

9.
Sci Adv ; 10(11): eadj6406, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489355

RESUMO

There is a compelling need to find drugs active against Mycobacterium tuberculosis (Mtb). 4'-Phosphopantetheinyl transferase (PptT) is an essential enzyme in Mtb that has attracted interest as a potential drug target. We optimized a PptT assay, used it to screen 422,740 compounds, and identified raltitrexed, an antineoplastic antimetabolite, as the most potent PptT inhibitor yet reported. While trying unsuccessfully to improve raltitrexed's ability to kill Mtb and remove its ability to kill human cells, we learned three lessons that may help others developing antibiotics. First, binding of raltitrexed substantially changed the configuration of the PptT active site, complicating molecular modeling of analogs based on the unliganded crystal structure or the structure of cocrystals with inhibitors of another class. Second, minor changes in the raltitrexed molecule changed its target in Mtb from PptT to dihydrofolate reductase (DHFR). Third, the structure-activity relationship for over 800 raltitrexed analogs only became interpretable when we quantified and characterized the compounds' intrabacterial accumulation and transformation.


Assuntos
Mycobacterium tuberculosis , Neoplasias , Quinazolinas , Tiofenos , Transferases (Outros Grupos de Fosfato Substituídos) , Humanos , Mycobacterium tuberculosis/metabolismo , Timidilato Sintase/metabolismo , Proteínas de Bactérias/metabolismo
10.
Appetite ; 60(1): 148-153, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23104227

RESUMO

Research has shown that water supplementation positively affects cognitive performance in children and adults. The present study considered whether this could be a result of expectancies that individuals have about the effects of water on cognition. Forty-seven participants were recruited and told the study was examining the effects of repeated testing on cognitive performance. They were assigned either to a condition in which positive expectancies about the effects of drinking water were induced, or a control condition in which no expectancies were induced. Within these groups, approximately half were given a drink of water, while the remainder were not. Performance on a thirst scale, letter cancellation, digit span forwards and backwards and a simple reaction time task was assessed at baseline (before the drink) and 20 min and 40 min after water consumption. Effects of water, but not expectancy, were found on subjective thirst ratings and letter cancellation task performance, but not on digit span or reaction time. This suggests that water consumption effects on letter cancellation are due to the physiological effects of water, rather than expectancies about the effects of drinking water.


Assuntos
Cognição/fisiologia , Ingestão de Líquidos/fisiologia , Análise e Desempenho de Tarefas , Sede/fisiologia , Adolescente , Adulto , Afeto/fisiologia , Atenção/fisiologia , Desidratação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Tempo de Reação , Visão Ocular/fisiologia , Adulto Jovem
11.
Artigo em Inglês | MEDLINE | ID: mdl-38083025

RESUMO

CT scans of the head and neck have multiple clinical uses, and simulating deformation of these CT scans allows for predicting patient motion and data augmentation for machine-learning methods. Current methods for creating patient-derived deformed CT scans require multiple scans or use unrealistic head and neck motion. This paper describes the CTHeadDeformation software package which allows for realistic synthetic deformation of head and neck CT scans for small amounts of motion. CTHeadDeformation is a python-based package that uses a kinematics-based approach using anatomical landmarks, and rigid/non-rigid registration to create a realistic patient-derived deformed CT scan. CTHeadDeformation is also designed for simple clinical implementation. The CTHeadDeformation software package was demonstrated on a head and neck CT scan of one patient. The CT scan was deformed in the anterior-posterior, superior-inferior, and left-right directions. Internal organ motion and more complex combination motions were also simulated. The results showed the patient's CT scan was able to be deformed in a way that preserved the shape and location of the anatomy.Clinical Relevance- This method allows for the realistic simulation of head and neck motion in CT scans. Clinical applications including simulating how patient motion affects radiation therapy treatment effectiveness. The CTHeadDeformation software can also be used to train machine-learning networks that are robust to patient motion, or to generate ground truth images for imaging or segmentation grand challenges.


Assuntos
Cabeça , Processamento de Imagem Assistida por Computador , Humanos , Fenômenos Biomecânicos , Processamento de Imagem Assistida por Computador/métodos , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X
12.
Pilot Feasibility Stud ; 9(1): 95, 2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37312127

RESUMO

BACKGROUND: This paper describes the protocol for the Nano X Image Guidance (Nano X IG) trial, a single-institution, clinical imaging study. The Nano X is a prototype fixed-beam radiotherapy system developed to investigate the feasibility of a low-cost, compact radiotherapy system to increase global access to radiation therapy. This study aims to assess the feasibility of volumetric image guidance with cone beam computed tomography (CBCT) acquired during horizontal patient rotation on the Nano X radiotherapy system. METHODS: In the Nano X IG study, we will determine whether radiotherapy image guidance can be performed with the Nano X radiotherapy system where the patient is horizontally rotated while scan projections are acquired. We will acquire both conventional CBCT scans and Nano X CBCT scans for 30 patients aged 18 and above and receiving radiotherapy for head/neck or upper abdomen cancers. For each patient, a panel of experts will assess the image quality of Nano X CBCT scans against conventional CBCT scans. Each patient will receive two Nano X CBCT scans to determine the image quality reproducibility, the extent and reproducibility of patient motion and assess patient tolerance. DISCUSSION: Fixed-beam radiotherapy systems have the potential to help ease the current shortfall and increase global access to radiotherapy treatment. Advances in image guidance could facilitate fixed-beam radiotherapy using horizontal patient rotation. The efficacy of this radiotherapy approach is dependent on our ability to image and adapt to motion due to rotation and for patients to tolerate rotation during treatment. TRIAL REGISTRATION: ClinicalTrials.gov, NCT04488224. Registered on 27 July 2020.

13.
Med Phys ; 50(7): 4206-4219, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37029643

RESUMO

BACKGROUND: Using radiation therapy (RT) to treat head and neck (H&N) cancers requires precise targeting of the tumor to avoid damaging the surrounding healthy organs. Immobilisation masks and planning target volume margins are used to attempt to mitigate patient motion during treatment, however patient motion can still occur. Patient motion during RT can lead to decreased treatment effectiveness and a higher chance of treatment related side effects. Tracking tumor motion would enable motion compensation during RT, leading to more accurate dose delivery. PURPOSE: The purpose of this paper is to develop a method to detect and segment the tumor in kV images acquired during RT. Unlike previous tumor segmentation methods for kV images, in this paper, a process for generating realistic and synthetic CT deformations was developed to augment the training data and make the segmentation method robust to patient motion. Detecting the tumor in 2D kV images is a necessary step toward 3D tracking of the tumor position during treatment. METHOD: In this paper, a conditional generative adversarial network (cGAN) is presented that can detect and segment the gross tumor volume (GTV) in kV images acquired during H&N RT. Retrospective data from 15 H&N cancer patients obtained from the Cancer Imaging Archive were used to train and test patient-specific cGANs. The training data consisted of digitally reconstructed radiographs (DRRs) generated from each patient's planning CT and contoured GTV. Training data was augmented by using synthetically deformed CTs to generate additional DRRs (in total 39 600 DRRs per patient or 25 200 DRRs for nasopharyngeal patients) containing realistic patient motion. The method for deforming the CTs was a novel deformation method based on simulating head rotation and internal tumor motion. The testing dataset consisted of 1080 DRRs for each patient, obtained by deforming the planning CT and GTV at different magnitudes to the training data. The accuracy of the generated segmentations was evaluated by measuring the segmentation centroid error, Dice similarity coefficient (DSC) and mean surface distance (MSD). This paper evaluated the hypothesis that when patient motion occurs, using a cGAN to segment the GTV would create a more accurate segmentation than no-tracking segmentations from the original contoured GTV, the current standard-of-care. This hypothesis was tested using the 1-tailed Mann-Whitney U-test. RESULTS: The magnitude of our cGAN segmentation centroid error was (mean ± standard deviation) 1.1 ± 0.8 mm and the DSC and MSD values were 0.90 ± 0.03 and 1.6 ± 0.5 mm, respectively. Our cGAN segmentation method reduced the segmentation centroid error (p < 0.001), and MSD (p = 0.031) when compared to the no-tracking segmentation, but did not significantly increase the DSC (p = 0.294). CONCLUSIONS: The accuracy of our cGAN segmentation method demonstrates the feasibility of this method for H&N cancer patients during RT. Accurate tumor segmentation of H&N tumors would allow for intrafraction monitoring methods to compensate for tumor motion during treatment, ensuring more accurate dose delivery and enabling better H&N cancer patient outcomes.


Assuntos
Aprendizado Profundo , Neoplasias de Cabeça e Pescoço , Humanos , Estudos Retrospectivos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Radiografia , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos
14.
ACS Infect Dis ; 9(5): 1046-1055, 2023 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-37083395

RESUMO

In September 2022, the Drug Discovery Unit at the University of Dundee, UK, organised an international meeting at the Wellcome Collection in London to explore the current clinical situation and challenges associated with treating schistosomiasis. The aim of this meeting was to discuss the need for new treatments in view of the clinical situation and to ascertain what the key requirements would be for any potential new anti-schistosomals. This information will be essential to inform ongoing drug discovery efforts for schistosomiasis. We also discussed the potential drug discovery pathway and associated criteria for progressing compounds to the clinic. To date, praziquantel (PZQ) is the only drug available to treat all species causing schistosomiasis, but it is often unable to completely clear parasites from an infected patient, partially due to its inactivity against juvenile worms. PZQ-mediated mass drug administration campaigns conducted in endemic areas (e.g., sub-Saharan Africa, where schistosomiasis is primarily prevalent) have contributed to reducing the burden of disease but will not eliminate the disease as a public health problem. The potential for Schistosoma to develop resistance towards PZQ, as the sole treatment available, could become a concern. Consequently, new anthelmintic medications are urgently needed, and this Perspective aims to capture some of the learnings from our discussions on the key criteria for new treatments.


Assuntos
Anti-Helmínticos , Esquistossomose , Animais , Londres , Esquistossomose/tratamento farmacológico , Praziquantel/farmacologia , Praziquantel/uso terapêutico , Anti-Helmínticos/farmacologia , Anti-Helmínticos/uso terapêutico , Schistosoma
15.
Bioorg Med Chem Lett ; 22(11): 3682-7, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22560471

RESUMO

The generation of novel CRTH2 ligands in heavily congested chemical space, by de novo design of libraries is disclosed. Novel (1719) compounds across seven libraries were synthesised. More than 100 of these compounds showed binding potency <3 µM against CRTH2, with the most potent being 247 nM. These libraries produced novel series and demonstrated that this approach is a viable one.


Assuntos
Receptores Imunológicos/antagonistas & inibidores , Receptores de Prostaglandina/antagonistas & inibidores , Bibliotecas de Moléculas Pequenas/química , Ácidos Carboxílicos/química , Humanos , Ligantes , Ligação Proteica , Receptores Imunológicos/metabolismo , Receptores de Prostaglandina/metabolismo , Bibliotecas de Moléculas Pequenas/farmacologia , Células Th2/efeitos dos fármacos , Células Th2/imunologia
16.
Conscious Cogn ; 21(1): 494-500, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22221741

RESUMO

The present study examined whether strategy moderated the relationship between visuospatial perspective-taking and empathy. Participants (N=96) undertook both a perspective-taking task requiring speeded spatial judgements made from the perspective of an observed figure and the Empathy Quotient questionnaire, a measure of trait empathy. Perspective-taking performance was found to be related to empathy in that more empathic individuals showed facilitated performance particularly for figures sharing their own spatial orientation. This relationship was restricted to participants that reported perspective-taking by mentally transforming their spatial orientation to align with that of the figure; it was absent in those adopting an alternative strategy of transposing left and right whenever confronted with a front-view figure. Our finding that strategy moderates the relationship between empathy and visuospatial perspective-taking enables a reconciliation of the apparently inconclusive findings of previous studies and provides evidence for functionally dissociable empathic and non-empathic routes to visuospatial perspective-taking.


Assuntos
Empatia , Orientação , Personalidade , Resolução de Problemas , Percepção Espacial , Adulto , Feminino , Humanos , Masculino , Tempo de Reação , Fatores Sexuais , Reino Unido
17.
Bioorg Med Chem Lett ; 21(21): 6591-5, 2011 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21955944

RESUMO

We describe the identification of a potent, selective lead series that shows antagonism against the human histamine H4 receptor from thirteen actives identified in an HTS as part of a hit to lead program. By focusing on ligand efficiency and concurrently using a diversity based approach, compounds based around 2,4-diaminopyrimidine were identified with compound 25 being quickly shown to be a good lead. It also had the highest ligand efficiency in the series.


Assuntos
Antagonistas dos Receptores Histamínicos/química , Antagonistas dos Receptores Histamínicos/farmacologia , Receptores Acoplados a Proteínas G/antagonistas & inibidores , Bibliotecas de Moléculas Pequenas , Humanos , Ligantes , Receptores Histamínicos , Receptores Histamínicos H4 , Estereoisomerismo , Relação Estrutura-Atividade
18.
JMIR Cardio ; 5(1): e26259, 2021 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-33949952

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) is a condition in which a person's airway is obstructed during sleep, thus disturbing their sleep. People with OSA are at a higher risk of developing heart problems. OSA is commonly treated with a positive airway pressure (PAP) therapy device, which is used during sleep. The PAP therapy setup provides a good opportunity to monitor the heart health of people with OSA, but no simple, low-cost method is available for the PAP therapy device to monitor heart rate (HR). OBJECTIVE: This study aims to develop a simple, low-cost device to monitor the HR of people with OSA during PAP therapy. This device was then tested on a small group of participants to investigate the feasibility of the device. METHODS: A low-cost and simple device to monitor HR was created by attaching a gyroscope to a PAP mask, thus integrating HR monitoring into PAP therapy. The gyroscope signals were then analyzed to detect heartbeats, and a Kalman filter was used to produce a more accurate and consistent HR signal. In this study, 19 participants wore the modified PAP mask while the mask was connected to a PAP device. Participants lay in 3 common sleeping positions and then underwent 2 different PAP therapy modes to determine if these affected the accuracy of the HR estimation. RESULTS: Before the PAP device was turned on, the median HR error was <5 beats per minute, although the HR estimation error increased when participants lay on their side compared with when participants lay on their back. Using the different PAP therapy modes did not significantly increase the HR error. CONCLUSIONS: These results show that monitoring HR from gyroscope signals in a PAP mask is possible during PAP therapy for different sleeping positions and PAP therapy modes, suggesting that long-term HR monitoring of OSA during PAP therapy may be possible.

19.
Arch Gerontol Geriatr ; 95: 104380, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33636649

RESUMO

OBJECTIVE: To systematically examine the effect of dehydration on health outcomes, identify associated financial costs and consider impacts on cognitive performance in older adults. DESIGN: A systematic review of English-language articles via OVID using MEDLINE, PsychINFO, EMBASE, and others, to March 2018. Included studies examined the relationship between hydration status and health, care costs or cognitive outcome. SETTING: Cross sectional and cohort data from studies reporting on dehydration in older adults. PARTICIPANTS: Adults aged 60 years and older. MEASUREMENTS: Independent quality ratings were assessed for all extracted articles. RESULTS: Of 1684 articles screened, 18 papers (N = 33,707) met inclusion criteria. Participants were recruited from hospital settings, medical long-term care centres and the community dwelling population. Data were synthesised using a narrative summary. Mortality rates were higher in dehydrated patients. Furthermore, health outcomes, including frailty, bradyarrhythmia, transient ischemic attacks, oral health and surgery recovery are linked to and worsened by dehydration. Length of hospital stay, either as a principal or secondary diagnosis, is greater in those with dehydration, compared to those who are euhydrated. Finally, neurocognitive functioning may be impacted by dehydration. There are issues with study design, inconsistency in hydration status measurement and different measures used for outcome assessment. CONCLUSION: Dehydration in older people is associated with increased mortality, poorer course of illness and increased costs for health services. In addition, there is some, but sparse evidence that dehydration in older people is linked to poorer cognitive performance. Intervention studies should test strategies for reducing dehydration in older adults.


Assuntos
Desidratação , Custos de Cuidados de Saúde , Idoso , Cognição , Estudos Transversais , Humanos , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde
20.
Phys Med Biol ; 66(10)2021 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-33878747

RESUMO

Fixed-gantry radiation therapy has been proposed as a low-cost alternative to the conventional rotating-gantry radiation therapy, that may help meet the rising global treatment demand. Fixed-gantry systems require gravitational motion compensated reconstruction algorithms to produce cone-beam CT (CBCT) images of sufficient quality for image guidance. The aim of this work was to adapt and investigate five CBCT reconstruction algorithms for fixed-gantry CBCT images. The five algorithms investigated were Feldkamp-Davis-Kress (FDK), prior image constrained compressed sensing (PICCS), gravitational motion compensated FDK (GMCFDK), motion compensated PICCS (MCPICCS) (a novel CBCT reconstruction algorithm) and simultaneous motion estimation and iterative reconstruction (SMEIR). Fixed-gantry and rotating-gantry CBCT scans were acquired of 3 rabbits, with the rotating-gantry scans used as a reference. Projections were sorted into rotation bins, based on the angle of rotation of the rabbit during image acquisition. The algorithms were compared using the structural similarity index measure root mean square error, and reconstruction time. Evaluation of the reconstructed volumes showed that, when compared with the reference rotating-gantry volume, the conventional FDK algorithm did not accurately reconstruct fixed-gantry CBCT scans. Whilst the PICCS reconstruction algorithm reduced some motion artefacts, the motion estimation reconstruction methods (GMCFDK, MCPICCS and SMEIR) were able to greatly reduce the effect of motion artefacts on the reconstructed volumes. This finding was verified quantitatively, with GMCFDK, MCPICCS and SMEIR reconstructions having RMSE 17%-19% lower and SSIM 1% higher than a conventional FDK. However, all motion compensated fixed-gantry CBCT reconstructions had a 56%-61% higher RMSE and 1.5% lower SSIM than FDK reconstructions of conventional rotating-gantry CBCT scans. The results show that motion compensation is required to reduce motion artefacts for fixed-gantry CBCT reconstructions. This paper further demonstrates the feasibility of fixed-gantry CBCT scans, and the ability of CBCT reconstruction algorithms to compensate for motion due to horizontal rotation.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada Quadridimensional , Algoritmos , Animais , Artefatos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Coelhos , Rotação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA