1.
Eur Radiol ; 2024 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-39242400

RESUMO

OBJECTIVES: The unprecedented surge in energy costs in Europe, coupled with the significant energy consumption of MRI scanners in radiology departments, necessitates exploring strategies to optimize energy usage without compromising efficiency or image quality. This study investigates MR energy consumption and identifies strategies for improving energy efficiency, focusing on musculoskeletal MRI. We assess the potential savings achievable through (1) optimizing protocols, (2) incorporating deep learning (DL) accelerated acquisitions, and (3) optimizing the cooling system. MATERIALS AND METHODS: Energy consumption measurements were performed on two MRI scanners (1.5-T Aera, 1.5-T Sola) in practices in Munich, Germany, between December 2022 and March 2023. Three levels of energy reduction measures were implemented and compared to the baseline. Wilcoxon signed-rank test with Bonferroni correction was conducted to evaluate the impact of sequence scan times and energy consumption. RESULTS: Our findings showed significant energy savings by optimizing protocol settings and implementing DL technologies. Across all body regions, the average reduction in energy consumption was 72% with DL and 31% with economic protocols, accompanied by time reductions of 71% (DL) and 18% (economic protocols) compared to baseline. Optimizing the cooling system during the non-scanning time showed a 30% lower energy consumption. CONCLUSION: Implementing energy-saving strategies, including economic protocols, DL accelerated sequences, and optimized magnet cooling, can significantly reduce energy consumption in MRI scanners. Radiology departments and practices should consider adopting these strategies to improve energy efficiency and reduce costs. CLINICAL RELEVANCE STATEMENT: MRI scanner energy consumption can be substantially reduced by incorporating protocol optimization, DL accelerated acquisition, and optimized magnetic cooling into daily practice, thereby cutting costs and environmental impact. KEY POINTS: Optimization of protocol settings reduced energy consumption by 31% and imaging time by 18%. DL technologies led to a 72% reduction in energy consumption of and a 71% reduction in time, compared to the standard MRI protocol. During non-scanning times, activating Eco power mode (EPM) resulted in a 30% reduction in energy consumption, saving 4881 € ($5287) per scanner annually.

2.
Radiology ; 306(3): e212922, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36318032

RESUMO

Background Deep learning (DL)-based MRI reconstructions can reduce examination times for turbo spin-echo (TSE) acquisitions. Studies that prospectively employ DL-based reconstructions of rapidly acquired, undersampled spine MRI are needed. Purpose To investigate the diagnostic interchangeability of an unrolled DL-reconstructed TSE (hereafter, TSEDL) T1- and T2-weighted acquisition method with standard TSE and to test their impact on acquisition time, image quality, and diagnostic confidence. Materials and Methods This prospective single-center study included participants with various spinal abnormalities who gave written consent from November 2020 to July 2021. Each participant underwent two MRI examinations: standard fully sampled T1- and T2-weighted TSE acquisitions (reference standard) and prospectively undersampled TSEDL acquisitions with threefold and fourfold acceleration. Image evaluation was performed by five readers. Interchangeability analysis and an image quality-based analysis were used to compare the TSE and TSEDL images. Acquisition time and diagnostic confidence were also compared. Interchangeability was tested using the individual equivalence index regarding various degenerative and nondegenerative entities, which were analyzed on each vertebra and defined as discordant clinical judgments of less than 5%. Interreader and intrareader agreement and concordance (κ and Kendall τ and W statistics) were computed and Wilcoxon and McNemar tests were used. Results Overall, 50 participants were evaluated (mean age, 46 years ± 18 [SD]; 26 men). The TSEDL method enabled up to a 70% reduction in total acquisition time (100 seconds for TSEDL vs 328 seconds for TSE, P < .001). All individual equivalence indexes were less than 4%. TSEDL acquisition was rated as having superior image noise by all readers (P < .001). No evidence of a difference was found between standard TSE and TSEDL regarding frequency of major findings, overall image quality, or diagnostic confidence. Conclusion The deep learning (DL)-reconstructed turbo spin-echo (TSE) method was found to be interchangeable with standard TSE for detecting various abnormalities of the spine at MRI. DL-reconstructed TSE acquisition provided excellent image quality, with a 70% reduction in examination time. German Clinical Trials Register no. DRKS00023278 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Hallinan in this issue.


Assuntos
Aprendizado Profundo , Masculino , Humanos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Coluna Vertebral/diagnóstico por imagem , Estudos Prospectivos , Tempo
3.
Eur Radiol ; 33(4): 2945-2953, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36474057

RESUMO

OBJECTIVE: To evaluate the impact of the digital mammography imaging system on overall background enhancement on recombined contrast-enhanced spectral mammography (CESM) images, the overall background enhancement of two different mammography systems was compared. METHODS: In a retrospective single-center study, CESM images of n = 129 female patients who underwent CESM between 2016 and 2019 were analyzed independently by two radiologists. Two mammography machines of different manufacturers were compared qualitatively using a Likert-scale from 1 (minimal) to 4 (marked overall background enhancement) and quantitatively by placing a region of interest and measuring the intensity enhancement. Lesion conspicuity was analyzed using a Likert-scale from 1 (lesion not reliably distinguishable) to 5 (excellent lesion conspicuity). A multivariate regression was performed to test for potential biases on the quantitative results. RESULTS: Significant differences in qualitative background enhancement measurements between machines A and B were observed for both readers (p = 0.003 and p < 0.001). The quantitative evaluation showed significant differences in background enhancement with an average difference of 75.69 (99%-CI [74.37, 77.02]; p < 0.001). Lesion conspicuity was better for machine A for the first and second reader respectively (p = 0.009 and p < 0.001). The factor machine was the only influencing factor (p < 0.001). The factors contrast agent, breast density, age, and menstrual cycle could be excluded as potential biases. CONCLUSION: Mammography machines seem to significantly influence overall background enhancement qualitatively and quantitatively; thus, an impact on diagnostic accuracy appears possible. KEY POINTS: • Overall background enhancement on CESM differs between different vendors qualitatively and quantitatively. • Our retrospective single-center study showed consistent results of the qualitative and quantitative data analysis of overall background enhancement. • Lesion conspicuity is higher in cases of lower background enhancement on CESM.


Assuntos
Neoplasias da Mama , Mamografia , Humanos , Feminino , Estudos Retrospectivos , Mamografia/métodos , Meios de Contraste/farmacologia , Densidade da Mama , Projetos de Pesquisa , Neoplasias da Mama/diagnóstico por imagem , Sensibilidade e Especificidade
4.
Pediatr Radiol ; 53(3): 438-449, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36399161

RESUMO

BACKGROUND: Cross-sectional imaging-based morphological characteristics of pediatric rhabdomyosarcoma have failed to predict outcomes. OBJECTIVE: To evaluate the feasibility and possible value of generating tumor sub-volumes using voxel-wise analysis of metabolic and functional data from positron emission tomography/magnetic resonance imaging (PET/MR) or PET/computed tomography (CT) and MRI in rhabdomyosarcoma. MATERIALS AND METHODS: Thirty-four examinations in 17 patients who received PET/MRI or PET/CT plus MRI were analyzed. The volume of interest included total tumor volume before and after therapy. Apparent diffusion coefficients (ADC) and standard uptake values (SUV) were determined voxel-wise. Voxels were assigned to three different groups based on ADC and SUV: "viable tumor tissue," "intermediate tissue" or "possible necrosis." In a second approach, data were grouped into three clusters using the Gaussian mixture model. The ratio of these clusters to total tumor volume and changes due to chemotherapy were correlated with clinical and histopathological data. RESULTS: After chemotherapy, the proportion of voxels in the different groups changed significantly. A significant reduction of the proportion of voxels assigned to cluster 1 was found, from a mean of 36.4% to 2.5% (P < 0.001). There was a significant increase in the proportion of voxels in cluster 3 following chemotherapy from 24.8% to 81.6% (P = 0.02). The proportion of voxels in cluster 2 differed depending on the presence or absence of tumor recurrence, falling from 48% to 10% post-chemotherapy in the group with no tumor recurrence (P < 0.05) and from 29% to 23% (P > 0.05) in the group with tumor recurrence. CONCLUSION: Voxel-wise evaluation of multimodal data in rhabdomyosarcoma is feasible. Our initial results suggest that the different distribution of sub-volumes before and after therapy may have prognostic significance.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Rabdomiossarcoma , Criança , Humanos , Fluordesoxiglucose F18 , Carga Tumoral , Recidiva Local de Neoplasia , Tomografia por Emissão de Pósitrons/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Compostos Radiofarmacêuticos
5.
Radiol Med ; 128(2): 184-190, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36609662

RESUMO

OBJECTIVES: A deep learning-based super-resolution for postcontrast volume-interpolated breath-hold examination (VIBE) of the chest was investigated in this study. Aim was to improve image quality, noise, artifacts and diagnostic confidence without change of acquisition parameters. MATERIALS AND METHODS: Fifty patients who received VIBE postcontrast imaging of the chest at 1.5 T were included in this retrospective study. After acquisition of the standard VIBE (VIBES), a novel deep learning-based algorithm and a denoising algorithm were applied, resulting in enhanced images (VIBEDL). Two radiologists qualitatively evaluated both datasets independently, rating sharpness of soft tissue, vessels, bronchial structures, lymph nodes, artifacts, cardiac motion artifacts, noise levels and overall diagnostic confidence, using a Likert scale ranging from 1 to 4. In the presence of lung lesions, the largest lesion was rated regarding sharpness and diagnostic confidence using the same Likert scale as mentioned above. Additionally, the largest diameter of the lesion was measured. RESULTS: The sharpness of soft tissue, vessels, bronchial structures and lymph nodes as well as the diagnostic confidence, the extent of artifacts, the extent of cardiac motion artifacts and noise levels were rated superior in VIBEDL (all P < 0.001). There was no significant difference in the diameter or the localization of the largest lung lesion in VIBEDL compared to VIBES. Lesion sharpness as well as detectability was rated significantly better by both readers with VIBEDL (both P < 0.001). CONCLUSION: The application of a novel deep learning-based super-resolution approach in T1-weighted VIBE postcontrast imaging resulted in an improvement in image quality, noise levels and diagnostic confidence as well as in a shortened acquisition time.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Aumento da Imagem/métodos , Artefatos
6.
Eur Radiol ; 32(9): 6215-6229, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35389046

RESUMO

OBJECTIVES: The aim of this study was to evaluate the image quality and diagnostic performance of a deep-learning (DL)-accelerated two-dimensional (2D) turbo spin echo (TSE) MRI of the knee at 1.5 and 3 T in clinical routine in comparison to standard MRI. MATERIAL AND METHODS: Sixty participants, who underwent knee MRI at 1.5 and 3 T between October/2020 and March/2021 with a protocol using standard 2D-TSE (TSES) and DL-accelerated 2D-TSE sequences (TSEDL), were enrolled in this prospective institutional review board-approved study. Three radiologists assessed the sequences regarding structural abnormalities and evaluated the images concerning overall image quality, artifacts, noise, sharpness, subjective signal-to-noise ratio, and diagnostic confidence using a Likert scale (1-5, 5 = best). RESULTS: Overall image quality for TSEDL was rated to be excellent (median 5, IQR 4-5), significantly higher compared to TSES (median 5, IQR 4 - 5, p < 0.05), showing significantly lower extents of noise and improved sharpness (p < 0.001). Inter- and intra-reader agreement was almost perfect (κ = 0.92-1.00) for the detection of internal derangement and substantial to almost perfect (κ = 0.58-0.98) for the assessment of cartilage defects. No difference was found concerning the detection of bone marrow edema and fractures. The diagnostic confidence of TSEDL was rated to be comparable to that of TSES (median 5, IQR 5-5, p > 0.05). Time of acquisition could be reduced to 6:11 min using TSEDL compared to 11:56 min for a protocol using TSES. CONCLUSION: TSEDL of the knee is clinically feasible, showing excellent image quality and equivalent diagnostic performance compared to TSES, reducing the acquisition time about 50%. KEY POINTS: • Deep-learning reconstructed TSE imaging is able to almost halve the acquisition time of a three-plane knee MRI with proton density and T1-weighted images, from 11:56 min to 6:11 min at 3 T. • Deep-learning reconstructed TSE imaging of the knee provided significant improvement of noise levels (p < 0.001), providing higher image quality (p < 0.05) compared to conventional TSE imaging. • Deep-learning reconstructed TSE imaging of the knee had similar diagnostic performance for internal derangement of the knee compared to standard TSE.


Assuntos
Aprendizado Profundo , Imageamento Tridimensional , Artefatos , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos
7.
Eur Radiol ; 31(12): 8975-8982, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34041572

RESUMO

OBJECTIVES: To evaluate computed tomography fractional flow reserve (FFRCT) values in distal parts of the coronaries in an asymptomatic cohort of marathon runners without any coronary stenosis for potentially false-positive values. METHODS: Ninety-eight asymptomatic male marathon runners (age 53 ± 7 years) were enrolled in a prospective monocentric study and underwent coronary computed tomography angiography (CCTA). CCTA data were analyzed for visual coronary artery stenosis. FFRCT was evaluated in 59 participants without coronary artery stenosis in proximal, mid, and distal coronary sections using an on-site software prototype. RESULTS: In participants without coronary artery stenosis, abnormal FFRCT values ≤ 0.8 in distal segments were found in 22 participants (37%); in 19 participants in the LAD; in 5 participants in the LCX; and in 4 participants in the RCA. Vessel diameters in participants with FFRCT values > 0.80 compared to ≤ 0.80 were 1.6 ± 0.3 mm versus 1.5 ± 0.3 mm for distal LAD (p = 0.025), 1.8 ± 0.3 mm versus 1.6 ± 0.5 mm for distal LCX (p = 0.183), and 2.0 ± 0.4 mm versus 1.5 ± 0.2 mm for distal RCA (p < 0.001). CONCLUSIONS: Abnormal FFRCT values of ≤ 0.8 frequently occurred in distal coronary segments in subjects without any anatomical coronary artery stenosis. This effect is only to some degree explainable by small distal vessel diameters. Therefore, the validity of hemodynamic relevance evaluation using FFRCT in distal coronary artery segment stenosis is reduced. KEY POINTS: • Abnormal FFRCT values (≤ 0.8) occurred in over a third of the subjects in the distal LAD despite the absence of coronary artery stenosis.. • Therefore, the validity of hemodynamic relevance evaluation in distal coronary artery segment stenosis is reduced. • Decision-making based on abnormal FFRCT values in distal vessel sections should be performed with caution and only in combination with visual assessment of the grade of stenosis..


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Masculino , Corrida de Maratona , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
8.
Pediatr Radiol ; 51(7): 1223-1230, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33544193

RESUMO

BACKGROUND: The prognostic value of the International Society of Paediatric Oncology European Neuroblastoma Research Network (SIOPEN) skeletal score using 123iodine-metaiodobenzylguanidine (MIBG) has been confirmed for people with high-risk neuroblastoma. Whole-body MRI with diffusion-weighted imaging is used increasingly. OBJECTIVE: To compare the original SIOPEN score and its adaption by diffusion-weighted imaging in high-risk stage 4 neuroblastoma and to evaluate any consequences of score differences on overall survival. MATERIALS AND METHODS: This retrospective observational study included pediatric patients who underwent MIBG scintigraphy and whole-body MRI, including diffusion-weighted imaging, between 2010 and 2015. Semi-quantitative skeletal scores for each exam were calculated independently. A difference of two or more points was defined as clinically relevant and counted as M+ (more in diffusion-weighted imaging) or S+ (more in MIBG). In cases of a negative result in one of the studies, residual disease of 1 point was also rated as relevant. We tested correlation and differences on an exam basis and also grouped by different therapeutic conditions. Overall survival was used to evaluate prognostic relevance. RESULTS: Seventeen children with 25 paired examinations were evaluated. Median MIBG scintigraphy score was 0 (interquartile range [IQR] 0-4, range 0-25) vs. a median whole-body MRI score of 1 (IQR 0-5.5, range 0-35) (P=0.018). A relevant difference between whole-body MRI and MIBG scintigraphy was noted in 14 of the 25 paired examinations (M+: n=9; S+: n=5). After treatment, the median survival of cases with M+ was 14 months (IQR 4-59, range 1-74 months), while S+ cases showed a median survival of 49 months (IQR 36-52, range 36-52 months) (P=0.413). CONCLUSION: The SIOPEN scoring system is feasible for whole-body MRI but might result in slightly higher scores, probably because of MRI's superior spatial resolution. Further studies are necessary to validate any impact on prognosis.


Assuntos
Iodo , Neuroblastoma , 3-Iodobenzilguanidina , Criança , Humanos , Imageamento por Ressonância Magnética , Neuroblastoma/diagnóstico por imagem , Projetos Piloto , Cintilografia , Compostos Radiofarmacêuticos , Imagem Corporal Total
9.
Eur Radiol ; 30(12): 6645-6652, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32725332

RESUMO

OBJECTIVES: Computed tomography (CT) imaging of the clavicula displays the reference standard for forensic bone age diagnostics in adolescents and young adults. Consequently, highest efforts on radiation reduction are warranted. Therefore, the aim of this study was to investigate the feasibility of low-dose (LD) CT imaging of the clavicula for age estimation in living adolescents. METHODS: A total of 207 non-contrast chest CT of 144 patients born between 1988 and 2012, performed in 2018 due to various clinical indications, were included in this retrospective study. The mean patient age was 16.9 ± 6.6 years. Patients were divided into a LD (n = 146) and standard-dose (SD; n = 61) group. Image quality, confidence levels, and ossification stages (using the 5-stage classification including the subgroups 2a-3c) were assessed by two radiologists independently. Radiation dose was determined via dosimetry software. RESULTS: Dose simulation with z-axis reduction to depict the clavicula only resulted in a median exposure of 0.1 mSv (IQR: 0.0) in LD compared with 0.9 mSv (IQR: 0.6) in SD (p < 0.001). The median image quality was rated by both readers significantly worse in LD compared with SD on a Likert scale ranging from 1 to 4 with a median of 3 (IQR: 1) versus 4 (IQR: 0; p < 0.001 for both readers). There was an almost perfect agreement for the ossification stages between both readers with a Cohen's kappa of 0.83 (p < 0.001). Median confidence levels of both readers were not significantly different between LD and SD in the decisive subgroups 2a-3c. CONCLUSIONS: Low-dose CT imaging of the clavicula for age estimation in living adolescents is possible without loss of readers' confidence. KEY POINTS: • Radiological bone age diagnostics in young delinquents with unknown exact chronological age is important as the judicial systems differentiate between youths and adults. • Low-dose computed tomography scanning of the medial clavicular joint for forensic age estimation is feasible in living adolescents without loss of readers' confidence. • Sufficient image quality of the medial clavicular joint for forensic bone age diagnostics in living adolescents is achievable using a median dose of 0.1 mSv.


Assuntos
Clavícula , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Criança , Humanos , Doses de Radiação , Cintilografia , Estudos Retrospectivos , Tórax , Adulto Jovem
10.
BMC Med Imaging ; 20(1): 105, 2020 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-32912148

RESUMO

BACKGROUND: MR imaging of neuroblastic tumors is widely used for assessing the effect of chemotherapy on tumor size. However, there are some concerns that MRI might falsely estimate lesion diameters due to calcification and fibrosis. Therefore, the aim of our study was to compare neuroblastic tumor size based on MRI measurements to histopathology measurements of the resected specimens as standard of reference. METHODS: Inclusion criteria were diagnosis of a neuroblastic tumor, MR imaging within 100 days to surgery and gross total resection without fragmentation of the tumor between 2008 and 2019. Lesion diameters were measured by two radiologists according to RECIST 1.1 in axial plane in T2w turbo spin echo (TSE), diffusion-weighted imaging (DWI), and in T1w pre- and postcontrast sequences. Furthermore, the largest lesion size in three-dimensions was noted. The largest diameter of histopathology measurements of each specimen was used for comparison with MRI. RESULTS: Thirty-seven patients (mean age: 5 ± 4 years) with 38 lesions (neuroblastoma: n = 17; ganglioneuroblastoma: n = 11; ganglioneuroma: n = 10) were included in this retrospective study. There was excellent intra-class correlation coefficient between both readers for all sequences (> 0.9) Tumor dimensions of reader 1 based on axial MRI measurements were significantly smaller with the following median differences (cm): T1w precontrast - 1.4 (interquartile range (IQR): 1.8), T1w postcontrast - 1.0 (IQR: 1.9), T2w TSE: -1.0 (IQR: 1.6), and DWI -1.3 (IQR: 2.2) (p < 0.001 for all sequences). However, the evaluation revealed no significant differences between the three-dimensional measurements and histopathology measurements of the resected specimens regardless of the applied MRI sequence. CONCLUSIONS: Axial MRI based lesion size measurements are significantly smaller than histopathological measurements. However, there was no significant difference between three-dimensional measurements and histopathology measurements of the resected specimens. T2w TSE and T1w postcontrast images provided the lowest deviation and might consequently be preferred for measurements.


Assuntos
Ganglioneuroblastoma/diagnóstico por imagem , Ganglioneuroblastoma/patologia , Ganglioneuroma/diagnóstico por imagem , Ganglioneuroma/patologia , Adolescente , Criança , Pré-Escolar , Imagem de Difusão por Ressonância Magnética , Feminino , Ganglioneuroblastoma/cirurgia , Ganglioneuroma/cirurgia , Humanos , Imageamento Tridimensional , Lactente , Recém-Nascido , Masculino , Variações Dependentes do Observador , Padrões de Referência , Estudos Retrospectivos , Carga Tumoral
12.
Eur Radiol ; 27(10): 4110-4119, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28289942

RESUMO

OBJECTIVES: To evaluate the effect of structured reports (SRs) in comparison to non-structured narrative free text (NRs) shoulder MRI reports and potential effects of both types of reporting on completeness, readability, linguistic quality and referring surgeons' satisfaction. METHODS: Thirty patients after trauma or with suspected degenerative changes of the shoulder were included in this study (2012-2015). All patients underwent shoulder MRI for further assessment and possible surgical planning. NRs were generated during clinical routine. Corresponding SRs were created using a dedicated template. All 60 reports were evaluated by two experienced orthopaedic shoulder surgeons using a questionnaire that included eight questions. RESULTS: Eighty per cent of the SRs were fully complete without any missing key features whereas only 45% of the NRs were fully complete (p < 0.001). The extraction of information was regarded to be easy in 92% of the SRs and 63% of the NRs. The overall quality of the SRs was rated better than that of the NRs (p < 0.001). CONCLUSIONS: Structured reporting of shoulder MRI improves the readability as well as the linguistic quality of radiological reports, and potentially leads to a higher satisfaction of referring physicians. KEY POINTS: • Structured MRI reports of the shoulder improve readability. • Structured reporting facilitates information extraction. • Referring physicians prefer structured reports to narrative free text reports. • Structured MRI reports of the shoulder can reduce radiologist re-consultations.


Assuntos
Relatório de Pesquisa/normas , Ombro/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Melhoria de Qualidade , Radiologia/normas , Encaminhamento e Consulta , Estudos Retrospectivos , Adulto Jovem
13.
Diagnostics (Basel) ; 14(19)2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39410643

RESUMO

Background: The aim of this study is to evaluate the correlation between background parenchymal enhancement (BPE) and various patient-related and technical factors in recombined contrast-enhanced spectral mammography (CESM) images. Material and Methods: We assessed CESM images from 62 female patients who underwent CESM between May 2017 and October 2019, focusing on factors influencing BPE. A total of 235 images, all acquired using the same mammography machine, were analyzed. A region of interest (ROI) with a standard size of 0.75 to 1 cm2 was used to evaluate the minimal, maximal, and average pixel intensity enhancement. Additionally, the images were qualitatively assessed on a scale from 1 (minimal BPE) to 4 (marked BPE). We examined correlations with body mass index (BMI), age, hematocrit, hemoglobin levels, cardiovascular conditions, and the amount of pressure applied during the examination. Results: Our study identified a significant correlation between the amount of pressure applied during the examination and the BPE (Spearman's ρ = 0.546). Additionally, a significant but weak correlation was observed between BPE and BMI (Spearman's ρ = 0.421). No significant associations were found between BPE and menopausal status, cardiovascular preconditions, hematocrit, hemoglobin levels, breast density, or age. Conclusions: Patient-related and procedural factors significantly influence BPE in CESM images. Specifically, increased applied pressure and BMI are associated with higher BPE.

14.
Jpn J Radiol ; 42(10): 1168-1177, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38867035

RESUMO

PURPOSE: To assess the diagnostic accuracy of ChatGPT-4V in interpreting a set of four chest CT slices for each case of COVID-19, non-small cell lung cancer (NSCLC), and control cases, thereby evaluating its potential as an AI tool in radiological diagnostics. MATERIALS AND METHODS: In this retrospective study, 60 CT scans from The Cancer Imaging Archive, covering COVID-19, NSCLC, and control cases were analyzed using ChatGPT-4V. A radiologist selected four CT slices from each scan for evaluation. ChatGPT-4V's interpretations were compared against the gold standard diagnoses and assessed by two radiologists. Statistical analyses focused on accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), along with an examination of the impact of pathology location and lobe involvement. RESULTS: ChatGPT-4V showed an overall diagnostic accuracy of 56.76%. For NSCLC, sensitivity was 27.27% and specificity was 60.47%. In COVID-19 detection, sensitivity was 13.64% and specificity of 64.29%. For control cases, the sensitivity was 31.82%, with a specificity of 95.24%. The highest sensitivity (83.33%) was observed in cases involving all lung lobes. The chi-squared statistical analysis indicated significant differences in Sensitivity across categories and in relation to the location and lobar involvement of pathologies. CONCLUSION: ChatGPT-4V demonstrated variable diagnostic performance in chest CT interpretation, with notable proficiency in specific scenarios. This underscores the challenges of cross-modal AI models like ChatGPT-4V in radiology, pointing toward significant areas for improvement to ensure dependability. The study emphasizes the importance of enhancing these models for broader, more reliable medical use.


Assuntos
COVID-19 , Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Humanos , COVID-19/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Pulmão/diagnóstico por imagem , Radiografia Torácica/métodos , Pandemias , Pneumonia Viral/diagnóstico por imagem , SARS-CoV-2 , Infecções por Coronavirus/diagnóstico por imagem , Reprodutibilidade dos Testes
15.
Tomography ; 10(2): 255-265, 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38393288

RESUMO

This study investigated the efficacy of single-phase dual-energy CT (DECT) in differentiating pulmonary hamartomas from malignant lung lesions using virtual non-contrast (VNC), iodine, and fat quantification. Forty-six patients with 47 pulmonary lesions (mean age: 65.2 ± 12.1 years; hamartomas-to-malignant lesions = 22:25; male: 67%) underwent portal venous DECT using histology, PET-CT and follow-up CTs as a reference. Quantitative parameters such as VNC, fat fraction, iodine density and CT mixed values were statistically analyzed. Significant differences were found in fat fractions (hamartomas: 48.9%; malignancies: 22.9%; p ≤ 0.0001) and VNC HU values (hamartomas: -20.5 HU; malignancies: 17.8 HU; p ≤ 0.0001), with hamartomas having higher fat content and lower VNC HU values than malignancies. CT mixed values also differed significantly (p ≤ 0.0001), but iodine density showed no significant differences. ROC analysis favored the fat fraction (AUC = 96.4%; sensitivity: 100%) over the VNC, CT mixed value and iodine density for differentiation. The study concludes that the DECT-based fat fraction is superior to the single-energy CT in differentiating between incidental pulmonary hamartomas and malignant lesions, while post-contrast iodine density is ineffective for differentiation.


Assuntos
Hamartoma , Iodo , Neoplasias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Hamartoma/diagnóstico por imagem
16.
Acad Radiol ; 31(3): 921-928, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37500416

RESUMO

RATIONALE AND OBJECTIVES: To determine the impact on acquisition time reduction and image quality of a deep learning (DL) reconstruction for accelerated diffusion-weighted imaging (DWI) of the pelvis at 1.5 T compared to standard DWI. MATERIALS AND METHODS: A total of 55 patients (mean age, 61 ± 13 years; range, 27-89; 20 men, 35 women) were consecutively included in this retrospective, monocentric study between February and November 2022. Inclusion criteria were (1) standard DWI (DWIS) in clinically indicated magnetic resonance imaging (MRI) at 1.5 T and (2) DL-reconstructed DWI (DWIDL). All patients were examined using the institution's standard MRI protocol according to their diagnosis including DWI with two different b-values (0 and 800 s/mm2) and calculation of apparent diffusion coefficient (ADC) maps. Image quality was qualitatively assessed by four radiologists using a visual 5-point Likert scale (5 = best) for the following criteria: overall image quality, noise level, extent of artifacts, sharpness, and diagnostic confidence. The qualitative scores for DWIS and DWIDL were compared with the Wilcoxon signed-rank test. RESULTS: The overall image quality was evaluated to be significantly superior in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .05). The extent of noise was evaluated to be significantly less in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .001). No significant differences were found regarding artifacts, lesion detectability, sharpness of organs, and diagnostic confidence (P > .05). Acquisition time for DWIS was 2:06 minutes, and simulated acquisition time for DWIDL was 1:12 minutes. CONCLUSION: DL image reconstruction improves image quality, and simulation results suggest that a reduction in acquisition time for diffusion-weighted MRI of the pelvis at 1.5 T is possible.


Assuntos
Aprendizado Profundo , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Razão Sinal-Ruído , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Pelve/diagnóstico por imagem , Artefatos , Imageamento por Ressonância Magnética
17.
Invest Radiol ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39043213

RESUMO

OBJECTIVE: Deep learning (DL)-enabled magnetic resonance imaging (MRI) reconstructions can enable shortening of breath-hold examinations and improve image quality by reducing motion artifacts. Prospective studies with DL reconstructions of accelerated MRI of the upper abdomen in the context of pancreatic pathologies are lacking. In a clinical setting, the purpose of this study is to investigate the performance of a novel DL-based reconstruction algorithm in T1-weighted volumetric interpolated breath-hold examinations with partial Fourier sampling and Dixon fat suppression (hereafter, VIBE-DixonDL). The objective is to analyze its impact on acquisition time, image sharpness and quality, diagnostic confidence, pancreatic lesion conspicuity, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). METHODS: This prospective single-center study included participants with various pancreatic pathologies who gave written consent from January 2023 to September 2023. During the same session, each participant underwent 2 MRI acquisitions using a 1.5 T scanner: conventional precontrast and postcontrast T1-weighted VIBE acquisitions with Dixon fat suppression (VIBE-Dixon, reference standard) using 4-fold parallel imaging acceleration and 6-fold accelerated VIBE-Dixon acquisitions with partial Fourier sampling utilizing a novel DL reconstruction tailored to the acquisition. A qualitative image analysis was performed by 4 readers. Acquisition time, image sharpness, overall image quality, image noise and artifacts, diagnostic confidence, as well as pancreatic lesion conspicuity and size were compared. Furthermore, a quantitative analysis of SNR and CNR was performed. RESULTS: Thirty-two participants were evaluated (mean age ± SD, 62 ± 19 years; 20 men). The VIBE-DixonDL method enabled up to 52% reduction in average breath-hold time (7 seconds for VIBE-DixonDL vs 15 seconds for VIBE-Dixon, P < 0.001). A significant improvement of image sharpness, overall image quality, diagnostic confidence, and pancreatic lesion conspicuity was observed in the images recorded using VIBE-DixonDL (P < 0.001). Furthermore, a significant reduction of image noise and motion artifacts was noted in the images recorded using the VIBE-DixonDL technique (P < 0.001). In addition, for all readers, there was no evidence of a difference in lesion size measurement between VIBE-Dixon and VIBE-DixonDL. Interreader agreement between VIBE-Dixon and VIBE-DixonDL regarding lesion size was excellent (intraclass correlation coefficient, >90). Finally, a statistically significant increase of pancreatic SNR in VIBE-DIXONDL was observed in both the precontrast (P = 0.025) and postcontrast images (P < 0.001). Also, an increase of splenic SNR in VIBE-DIXONDL was observed in both the precontrast and postcontrast images, but only reaching statistical significance in the postcontrast images (P = 0.34 and P = 0.003, respectively). Similarly, an increase of pancreas CNR in VIBE-DIXONDL was observed in both the precontrast and postcontrast images, but only reaching statistical significance in the postcontrast images (P = 0.557 and P = 0.026, respectively). CONCLUSIONS: The prospectively accelerated, DL-enhanced VIBE with Dixon fat suppression was clinically feasible. It enabled a 52% reduction in breath-hold time and provided superior image quality, diagnostic confidence, and pancreatic lesion conspicuity. This technique might be especially useful for patients with limited breath-hold capacity.

18.
Diagnostics (Basel) ; 14(17)2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39272773

RESUMO

Purpose: This study evaluates a deep learning-based denoising algorithm to improve the trade-off between radiation dose, image noise, and motion artifacts in TIPSS procedures, aiming for shorter acquisition times and reduced radiation with maintained diagnostic quality. Methods: In this retrospective study, TIPSS patients were divided based on CBCT acquisition times of 6 s and 3 s. Traditional weighted filtered back projection (Original) and an AI denoising algorithm (AID) were used for image reconstructions. Objective assessments of image quality included contrast, noise levels, and contrast-to-noise ratios (CNRs) through place-consistent region-of-interest (ROI) measurements across various critical areas pertinent to the TIPSS procedure. Subjective assessments were conducted by two blinded radiologists who evaluated the overall image quality, sharpness, contrast, and motion artifacts for each dataset combination. Statistical significance was determined using a mixed-effects model (p ≤ 0.05). Results: From an initial cohort of 60 TIPSS patients, 44 were selected and paired. The mean dose-area product (DAP) for the 6 s acquisitions was 5138.50 ± 1325.57 µGy·m2, significantly higher than the 2514.06 ± 691.59 µGym2 obtained for the 3 s series. CNR was highest in the 6 s-AID series (p < 0.05). Both denoised and original series showed consistent contrast for 6 s and 3 s acquisitions, with no significant noise differences between the 6 s Original and 3 s AID images (p > 0.9). Subjective assessments indicated superior quality in 6 s-AID images, with no significant overall quality difference between the 6 s-Original and 3 s-AID series (p > 0.9). Conclusions: The AI denoising algorithm enhances CBCT image quality in TIPSS procedures, allowing for shorter scans that reduce radiation exposure and minimize motion artifacts.

19.
Eur J Radiol Open ; 12: 100557, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38495213

RESUMO

Purpose: The objective of this study was to implement a 5-minute MRI protocol for the shoulder in routine clinical practice consisting of accelerated 2D turbo spin echo (TSE) sequences with deep learning (DL) reconstruction at 1.5 and 3 Tesla, and to compare the image quality and diagnostic performance to that of a standard 2D TSE protocol. Methods: Patients undergoing shoulder MRI between October 2020 and June 2021 were prospectively enrolled. Each patient underwent two MRI examinations: first a standard, fully sampled TSE (TSES) protocol reconstructed with a standard reconstruction followed by a second fast, prospectively undersampled TSE protocol with a conventional parallel imaging undersampling pattern reconstructed with a DL reconstruction (TSEDL). Image quality and visualization of anatomic structures as well as diagnostic performance with respect to shoulder lesions were assessed using a 5-point Likert-scale (5 = best). Interchangeability analysis, Wilcoxon signed-rank test and kappa statistics were performed to compare the two protocols. Results: A total of 30 participants was included (mean age 50±15 years; 15 men). Overall image quality was evaluated to be superior in TSEDL versus TSES (p<0.001). Noise and edge sharpness were evaluated to be significantly superior in TSEDL versus TSES (noise: p<0.001, edge sharpness: p<0.05). No difference was found concerning qualitative diagnostic confidence, assessability of anatomical structures (p>0.05), and quantitative diagnostic performance for shoulder lesions when comparing the two sequences. Conclusions: A fast 5-minute TSEDL MRI protocol of the shoulder is feasible in routine clinical practice at 1.5 and 3 T, with interchangeable results concerning the diagnostic performance, allowing a reduction in scan time of more than 50% compared to the standard TSES protocol.

20.
Acad Radiol ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38955591

RESUMO

RATIONALE AND OBJECTIVES: To compare a conventional T1 volumetric interpolated breath-hold examination (VIBE) with SPectral Attenuated Inversion Recovery (SPAIR) fat saturation and a deep learning (DL)-reconstructed accelerated VIBE sequence with SPAIR fat saturation achieving a 50 % reduction in breath-hold duration (hereafter, VIBE-SPAIRDL) in terms of image quality and diagnostic confidence. MATERIALS AND METHODS: This prospective study enrolled consecutive patients referred for upper abdominal MRI from November 2023 to December 2023 at a single tertiary center. Patients underwent upper abdominal MRI with acquisition of non-contrast and gadobutrol-enhanced conventional VIBE-SPAIR (fourfold acceleration, acquisition time 16 s) and VIBE-SPAIRDL (sixfold acceleration, acquisition time 8 s) on a 1.5 T scanner. Image analysis was performed by four readers, evaluating homogeneity of fat suppression, perceived signal-to-noise ratio (SNR), edge sharpness, artifact level, lesion detectability and diagnostic confidence. A statistical power analysis for patient sample size estimation was performed. Image quality parameters were compared by a repeated measures analysis of variance, and interreader agreement was assessed using Fleiss' κ. RESULTS: Among 450 consecutive patients, 45 patients were evaluated (mean age, 60 years ± 15 [SD]; 27 men, 18 women). VIBE-SPAIRDL acquisition demonstrated superior SNR (P < 0.001), edge sharpness (P < 0.001), and reduced artifacts (P < 0.001) with substantial to almost perfect interreader agreement for non-contrast (κ: 0.70-0.91) and gadobutrol-enhanced MRI (κ: 0.68-0.87). No evidence of a difference was found between conventional VIBE-SPAIR and VIBE-SPAIRDL regarding homogeneity of fat suppression, lesion detectability, or diagnostic confidence (all P > 0.05). CONCLUSION: Deep learning reconstruction of VIBE-SPAIR facilitated a reduction of breath-hold duration by half, while reducing artifacts and improving image quality. SUMMARY: Deep learning reconstruction of prospectively accelerated T1 volumetric interpolated breath-hold examination for upper abdominal MRI enabled a 50 % reduction in breath-hold time with superior image quality. KEY RESULTS: 1) In a prospective analysis of 45 patients referred for upper abdominal MRI, accelerated deep learning (DL)-reconstructed VIBE images with spectral fat saturation (SPAIR) showed better overall image quality, with better perceived signal-to-noise ratio and less artifacts (all P < 0.001), despite a 50 % reduction in acquisition time compared to conventional VIBE. 2) No evidence of a difference was found between conventional VIBE-SPAIR and accelerated VIBE-SPAIRDL regarding lesion detectability or diagnostic confidence.