Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Chemphyschem ; 25(5): e202300768, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38153248

RESUMO

In this work, we present a detailed study of the interaction between ascorbic acid (L-asc) and anatase TiO2 (101) surface both in gas phase and in contact with water by using density functional theory and ab initio molecular dynamics simulations. In gas phase, L-asc strongly binds the TiO2 (101) surface as a dianion (L-asc2- ), adopting a bridging bidentate coordination mode (BB), with the two acid protons transferred to two surface 2-fold bridging oxygens (O2c). AIMD simulations show that the interaction between the organic ligand and the anatase surface is stable and comparable to the vacuum one despite the possible solvent effects and/or possible structural distortions of the ligand. In addition, during the AIMD simulations hydroxylation phenomena occur forming transient H3 O+ ions at the solid-liquid interface. For the first time, our results provide insight into the role of the ascorbic acid on the electronic properties of the TiO2 (101), the influence of the water environment on the ligand-surface interaction and the nature of the solid-liquid interface.

2.
Q J Nucl Med Mol Imaging ; 68(2): 152-159, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38860276

RESUMO

Theragnostics represents one of the most innovative fields of precision medicine with a huge potential in the field of oncology in the next years. The use of a pair of selective radiopharmaceuticals for cellular receptors, used for diagnostic and therapeutic purposes (PRRT), finds applications in the Neuroendocrine tumors and metastatic Castration-Resistant prostate cancer (mCRPC) thanks, respectively, to somatostatin receptor agonists and PSMA-based peptides. Further evolutions of theragnostics will be possible to the radioimmunoconjugates used both in the diagnostic (Immuno-PET) and in the therapeutic fields (radioimmunotherapy). It is evident that in the "omics-era," theragnostics could become a necessary method, not only in order to improve our knowledge of tumor biology, but also, to find more and more targeted therapies in a multidisciplinary context and in a tailor-based approach.


Assuntos
Medicina de Precisão , Humanos , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/radioterapia , Medicina de Precisão/métodos , Neoplasias de Próstata Resistentes à Castração/radioterapia , Neoplasias de Próstata Resistentes à Castração/patologia , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Compostos Radiofarmacêuticos/uso terapêutico , Masculino
3.
Radiol Med ; 128(6): 704-713, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37198373

RESUMO

Digital Breast Tomosynthesis (DBT) is a cutting-edge technology introduced in recent years as an in-depth analysis of breast cancer diagnostics. Compared with 2D Full-Field Digital Mammography, DBT has demonstrated greater sensitivity and specificity in detecting breast tumors. This work aims to quantitatively evaluate the impact of the systematic introduction of DBT in terms of Biopsy Rate and Positive Predictive Values for the number of biopsies performed (PPV-3). For this purpose, we collected 69,384 mammograms and 7894 biopsies, of which 6484 were Core Biopsies and 1410 were stereotactic Vacuum-assisted Breast Biopsies (VABBs), performed on female patients afferent to the Breast Unit of the Istituto Tumori "Giovanni Paolo II" of Bari from 2012 to 2021, thus, in the period before, during and after the systematic introduction of DBT. Linear regression analysis was then implemented to investigate how the Biopsy Rate had changed over the 10 year screening. The next step was to focus on VABBs, which were generally performed during in-depth examinations of mammogram detected lesions. Finally, three radiologists from the institute's Breast Unit underwent a comparative study to ascertain their performances in terms of breast cancer detection rates before and after the introduction of DBT. As a result, it was demonstrated that both the overall Biopsy Rate and the VABBs Biopsy Rate significantly decreased following the introduction of DBT, with the diagnosis of an equal number of tumors. Besides, no statistically significant differences were observed among the three operators evaluated. In conclusion, this work highlights how the systematic introduction of DBT has significantly impacted the breast cancer diagnostic procedure, by improving the diagnostic quality and thereby reducing needless biopsies, resulting in a consequent reduction in costs.


Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Feminino , Humanos , Detecção Precoce de Câncer/métodos , Estudos Retrospectivos , Mama/diagnóstico por imagem , Mamografia/métodos , Neoplasias da Mama/patologia , Biópsia Guiada por Imagem/métodos , Biópsia com Agulha de Grande Calibre
4.
Radiol Med ; 127(6): 673-680, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35536526

RESUMO

PURPOSE: To assess and compare the clinical effectiveness of percutaneous intradiscal ozone therapy in patients affected by lumbar disc herniation, with and without history of COVID-19 infection. MATERIALS AND METHODS: After the rising of COVID-19 pandemics in Italy, 47 consecutive percutaneous intradiscal ozone therapies were performed on patients with low back pain and/or sciatic pain due to lumbar disc herniation. Among these, 19 had suffered from COVID-19 and successively recovered with no residual symptoms, while the remaining 28 had not previously been affected by COVID-19 and were not convalescent. Oswestry Disability Index (ODI) was administered before the treatment and at 1-month and 3-month follow-up in order to assess the clinical outcome. RESULTS: The two groups were similar in terms of patient age (p-value 0.54), treated levels (p-value 0.26) and pre-procedure ODI (p-value 0.33). Technical success was achieved in all cases. In patients previously affected by COVID-19, mean ODI decrease was 11.58 ± 9.51 (35.72%) at 1-month follow-up and 20.63 ± 9.87 (63.63%) at 3-month follow-up. In patients never affected by COVID-19, mean ODI decrease was 20.93 ± 10.53 (58.73%) at 1-month follow-up and 22.07 ± 11.36 (61.92%) at 3-month follow-up. Eventually, clinical success was registered in 84.21% (16/19) of patients with history of COVID-19 infection and in 85.71% (24/28) of patients with no history of COVID-19 infection. No major complication was registered. CONCLUSIONS: In case of lumbar disc herniation treated with percutaneous intradiscal ozone therapy, patients previously affected by COVID-19 showed a significantly longer recovery time.


Assuntos
COVID-19 , Deslocamento do Disco Intervertebral , Dor Lombar , Ozônio , COVID-19/complicações , Humanos , Deslocamento do Disco Intervertebral/complicações , Deslocamento do Disco Intervertebral/terapia , Dor Lombar/tratamento farmacológico , Dor Lombar/etiologia , Vértebras Lombares , Ozônio/uso terapêutico , Resultado do Tratamento
5.
Radiol Med ; 127(8): 848-856, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35816260

RESUMO

BACKGROUND: Pectoral muscle removal is a fundamental preliminary step in computer-aided diagnosis systems for full-field digital mammography (FFDM). Currently, two open-source publicly available packages (LIBRA and OpenBreast) provide algorithms for pectoral muscle removal within Matlab environment. PURPOSE: To compare performance of the two packages on a single database of FFDM images. METHODS: Only mediolateral oblique (MLO) FFDM was considered because of large presence of pectoral muscle on this type of projection. For obtaining ground truth, pectoral muscle has been manually segmented by two radiologists in consensus. Both LIBRA's and OpenBreast's removal performance with respect to ground truth were compared using Dice similarity coefficient and Cohen-kappa reliability coefficient; Wilcoxon signed-rank test has been used for assessing differences in performances; Kruskal-Wallis test has been used to verify possible dependence of the performance from the breast density or image laterality. RESULTS: FFDMs from 168 consecutive women at our institution have been included in the study. Both LIBRA's Dice-index and Cohen-kappa were significantly higher than OpenBreast (Wilcoxon signed-rank test P < 0.05). No dependence on breast density or laterality has been found (Kruskal-Wallis test P > 0.05). CONCLUSION: Libra has a better performance than OpenBreast in pectoral muscle delineation so that, although our study has not a direct clinical application, these results are useful in the choice of packages for the development of complex systems for computer-aided breast evaluation.


Assuntos
Neoplasias da Mama , Músculos Peitorais , Algoritmos , Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Mamografia/métodos , Músculos Peitorais/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes
6.
Radiol Med ; 127(5): 526-533, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35290568

RESUMO

PURPOSE: To compare clinical success and operative time for percutaneous intradiscal ozone therapy in patients with lumbar disc herniation using fluoroscopic guidance versus computed tomography (CT). MATERIALS AND METHODS: During the year 2019, 68 percutaneous single-level intradiscal ozone therapies were performed on patients complaining of low back pain and/or sciatica due to lumbar disc herniation, using fluoroscopic or conventional CT guidance, respectively, in 35 and 32 herniated lumbar discs, with at least 1-month follow-up. Oswestry Disability Index (ODI) was used to assess clinical outcome. Total room utilization time and procedure operative time were recorded for both fluoroscopy and CT guidance. RESULTS: Fluoroscopy and CT groups were similar in terms of patient age (p value 0.45) and pre-procedure ODI (p value 0.64). Clinical success was obtained in 87.50% (28/32) patients in fluoroscopic group and 83.33% (30/36) in CT group. Mean total room utilization time was significantly longer for CT guidance (31.38 vs. 50.67 min, p < 0.0001), as well as the procedure operative time (15.94 vs. 27.61 min, p < 0.0001). CONCLUSIONS: Compared to conventional CT guidance, fluoroscopic guidance for percutaneous intradiscal ozone therapy in patients with lumbar disc herniation shows similar clinical success rates at 1-month follow-up, with decreased room utilization time and procedure operative time that implies less time consumption for medical and paramedical operative team.


Assuntos
Deslocamento do Disco Intervertebral , Ozônio , Fluoroscopia , Humanos , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Duração da Cirurgia , Ozônio/uso terapêutico , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
BMC Cardiovasc Disord ; 20(1): 373, 2020 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-32799852

RESUMO

BACKGROUND: Hypertension is the most frequent co-morbidity in patients with covid-19 infection, and we might speculate that a specific blood group could play a key role in the clinical outcome of hypertensive patients with covid-19. METHODS: In this prospective study, we compared 0 vs. non-0 blood group in hypertensive patients with covid-19 infection. In these patients, we evaluated inflammatory and thrombotic status, cardiac injury, and death events. RESULTS: Patients in non-0 (n = 92) vs. 0 blood group (n = 72) had significantly different values of activated pro-thrombin time, D-dimer, and thrombotic indexes as Von Willebrand factor and Factor VIII (p < 0.05). Furthermore, patients in non-0 vs. 0 blood group had higher rate of cardiac injury (10 (13.9%) vs. 27 (29.3%)) and death, (6 (8.3%) vs. 18 (19.6%)), (p < 0.05). At the multivariate analysis, Interleukin-6 (1.118, CI 95% 1.067-1.171) and non-0 blood group (2.574, CI 95% 1.207-5.490) were independent predictors of cardiac injury in hypertensive patients with covid-19. D-dimer (1.082, CI 95% 1.027-1.140), Interleukin-6 (1.216, CI 95% 1.082-1.367) and non-0 blood group (3.706, CI 95% 1.223-11.235) were independent predictors of deaths events in hypertensive patients with covid-19. CONCLUSIONS: Taken together, our data indicate that non-0 covid-19 hypertensive patients have significantly higher values of pro-thrombotic indexes, as well as higher rate of cardiac injury and deaths compared to 0 patients. Moreover, AB0 blood type influences worse prognosis in hypertensive patients with covid-19 infection.


Assuntos
Sistema ABO de Grupos Sanguíneos , Betacoronavirus/patogenicidade , Pressão Sanguínea , Infecções por Coronavirus/sangue , Hipertensão/sangue , Pneumonia Viral/sangue , Adulto , Idoso , Biomarcadores/sangue , Coagulação Sanguínea , Fatores de Coagulação Sanguínea/análise , COVID-19 , Estudos de Casos e Controles , Comorbidade , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/virologia , Feminino , Interações Hospedeiro-Patógeno , Humanos , Hipertensão/diagnóstico , Hipertensão/epidemiologia , Hipertensão/fisiopatologia , Mediadores da Inflamação/sangue , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/diagnóstico , Pneumonia Viral/epidemiologia , Pneumonia Viral/virologia , Estudos Prospectivos , Fatores de Risco , SARS-CoV-2
8.
J Surg Res ; 233: 88-95, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30502293

RESUMO

BACKGROUND: We aimed to assess whether the use of the harmonic scalpel (HS) in axillary dissection would reduce long-term shoulder-arm morbidity compared to traditional instruments (TIs). MATERIALS AND METHODS: A retrospective analysis on 180 patients who underwent standard axillary dissection for breast cancer between 2007 and 2015 was carried out. All patients were evaluated for postoperative pain, impairment of shoulder-arm mobility, seroma formation in axilla, frozen shoulder, and lymphedema. RESULTS: HS procedure on average was 50% shorter compared to the TI technique. HS reduced by 4.5 times the risk of axillary seroma. TIs were associated with 4 times higher risk of developing a painful frozen shoulder. CONCLUSIONS: Use of the HS was associated with reduced costs and a positive long-term effect on shoulder-arm morbidity. Axillary seromas are not the only reason of later postoperative shoulder-arm morbidity: other mechanisms are hypothesized in the onset of this very disabling disorder.


Assuntos
Linfedema Relacionado a Câncer de Mama/epidemiologia , Neoplasias da Mama/cirurgia , Bursite/epidemiologia , Dor Pós-Operatória/epidemiologia , Biópsia de Linfonodo Sentinela/efeitos adversos , Seroma/epidemiologia , Procedimentos Cirúrgicos Ultrassônicos/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Braço/fisiopatologia , Axila , Linfedema Relacionado a Câncer de Mama/economia , Linfedema Relacionado a Câncer de Mama/fisiopatologia , Neoplasias da Mama/patologia , Bursite/economia , Bursite/fisiopatologia , Redução de Custos , Feminino , Seguimentos , Humanos , Metástase Linfática/diagnóstico , Metástase Linfática/patologia , Mastectomia/efeitos adversos , Mastectomia/instrumentação , Pessoa de Meia-Idade , Dor Pós-Operatória/economia , Dor Pós-Operatória/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Estudos Retrospectivos , Biópsia de Linfonodo Sentinela/instrumentação , Seroma/economia , Seroma/fisiopatologia , Ombro/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Ultrassônicos/instrumentação
9.
Radiol Med ; 124(2): 103-108, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30368720

RESUMO

The pathogenesis of acute ischaemic colitis depends on two different forms of vascular colonic insult: occlusive injury and non-occlusive injury. Clinically, ischaemic colitis may be classified as two major forms: mild (non-gangrenous) and acute fulminant (gangrenous). The classic presentation is abdominal pain, diarrhoea and/or rectal bleeding, but it is not specific and highly variable and so the diagnosis usually depends on clinical suspicion and is supported by serologic and colonoscopic findings. Imaging methods have their role in diagnosing IC. While plain radiography and ultrasound can orient the diagnosis, CT allows to define the morphofunctional alterations discriminating the non-occlusive forms from the occlusive forms and in most cases to estimate the timing of ischaemic damage. Purpose of the review is to define the role of CT in the early identification of pathological findings and in the definition of evolution of colonic ischaemic lesions, in order to plan the correct therapeutic approach, suggesting the decision of medical or surgical treatment.


Assuntos
Colite Isquêmica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Colonoscopia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Estudos Retrospectivos
10.
Cancer Invest ; 34(7): 355-60, 2016 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-27438775

RESUMO

AIM: To compare efficiency levels between radiologist and radiology resident and any significant or clinically relevant differences in breast ultrasound diagnosis, thus reducing extra costs. MATERIAL AND METHODS: 100 patients attending for breast ultrasound were included. Each patient was examined by a radiologist, and subsequently by a resident of the radiology department. Both operators noted their findings and wrote a concluding report. Reports were compared for histological and biological analysis. RESULTS: 100 female patients with a mean age about 49 years were examined. The proportions of correct diagnoses of lesions individuated by radiologist and resident were 26.90 > 13.71% (p-value = 10.7), i.e. the radiologist was more accurate in comparison to resident in the individuation of breast lesions. CONCLUSIONS: The radiologist was more accurate in comparison to radiology resident in the evaluation of breast pathology in ultrasonography diagnoses, and this could reduce cost and/or in-depth analysis.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Variações Dependentes do Observador , Médicos , Radiologistas , Ultrassonografia/economia , Ultrassonografia/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Custos Diretos de Serviços , Feminino , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Adulto Jovem
11.
Radiol Med ; 120(9): 795-801, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26183038

RESUMO

Approximately 4 % of radiologic interpretation in daily practice contains errors and discrepancies that should occur in 2-20 % of reports. Fortunately, most of them are minor degree errors, or if serious, are found and corrected with sufficient promptness; obviously, diagnostic errors become critical when misinterpretation or misidentification should significantly delay medical or surgical treatments. Errors can be summarized into four main categories: observer errors, errors in interpretation, failure to suggest the next appropriate procedure, failure to communicate in a timely and a clinically appropriate manner. Misdiagnosis/misinterpretation percentage should rise up in emergency setting and in the first moments of the learning curve, as in residency. Para-physiological and pathological pitfalls in neuroradiology include calcification and brain stones, pseudofractures, and enlargement of subarachnoid or epidural spaces, ventricular system abnormalities, vascular system abnormalities, intracranial lesions or pseudolesions, and finally neuroradiological emergencies. In order to minimize the possibility of error, it is important to be aware of various presentations of pathology, obtain clinical information, know current practice guidelines, review after interpreting a diagnostic study, suggest follow-up studies when appropriate, communicate significant abnormal findings appropriately and in a timely fashion directly with the treatment team.


Assuntos
Encefalopatias/diagnóstico , Erros de Diagnóstico , Neuroimagem , Competência Clínica , Humanos , Radiologia/educação
12.
Radiol Med ; 120(1): 105-17, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25115295

RESUMO

Intestinal intussusception in adults is a rare condition, accounting for about 0.003-0.02% of all hospital admissions. This condition in adults represents only 5% of all cases of intussusceptions and is different from paediatric intussusception, which is usually idiopathic. In contrast, almost 90% of cases in adults are secondary to various pathologies that serve as a lead point, such as polyps, Meckel's diverticulum, colonic diverticulum, or malignant or benign neoplasm. The aim of the present study was to assess the capabilities of multislice computed tomography (MSCT) in the diagnosis and correct characterisation of intussusception, especially in distinguishing between intussusceptions with a lead point and those without. Indeed, although the MSCT findings that help to differentiate between lead point and non-lead point intussusceptions have not been well studied, abdominal MSCT remains the most sensitive radiological tool to confirm bowel intussusceptions. Moreover, differentiating intussusceptions with a lead point condition from those without is crucial for directing the patient towards the most appropriate treatment, avoiding surgery when not necessary.


Assuntos
Intussuscepção/diagnóstico por imagem , Adulto , Idoso , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Intussuscepção/etiologia , Intussuscepção/terapia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
13.
Radiol Med ; 119(7): 512-20, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24927806

RESUMO

Thermal radiofrequency ablation is a relatively new, minimally invasive modality employed as an alternative to surgery in patients with benign thyroid nodules and recurrent thyroid cancers. Different recommendations are necessary for the optimal use of radiofrequency ablation for thyroid nodules. These recommendations are based on a comprehensive analysis of the current literature, the results of multicenter studies, and expert consensus.


Assuntos
Ablação por Cateter/métodos , Neoplasias da Glândula Tireoide/cirurgia , Nódulo da Glândula Tireoide/cirurgia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Recidiva Local de Neoplasia/cirurgia , Ondas de Rádio , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia , Ultrassonografia de Intervenção
14.
BMC Surg ; 13 Suppl 2: S53, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24267789

RESUMO

BACKGROUND: Purpose of the study is to define the role of conventional radiology and MRI in the evaluation of pelvic floor hernias in female pelvic floor disorders. METHODS: A MEDLINE and PubMed search was performed for journals before March 2013 with MeSH major terms 'MR Defecography' and 'pelvic floor hernias'. RESULTS: The prevalence of pelvic floor hernias at conventional radiology was higher if compared with that at MRI. Concerning the hernia content, there were significantly more enteroceles and sigmoidoceles on conventional radiology than on MRI, whereas, in relation to the hernia development modalities, the prevalence of elytroceles, edroceles, and Douglas' hernias at conventional radiology was significantly higher than that at MRI. CONCLUSIONS: MRI shows lower sensitivity than conventional radiology in the detection of pelvic floor hernias development. The less-invasive MRI may have a role in a better evaluation of the entire pelvic anatomy and pelvic organ interaction especially in patients with multicompartmental defects, planned for surgery.


Assuntos
Defecografia/métodos , Hérnia/diagnóstico por imagem , Imageamento por Ressonância Magnética , Distúrbios do Assoalho Pélvico/diagnóstico por imagem , Feminino , Humanos
15.
Aesthetic Plast Surg ; 37(5): 1012-22, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23860822

RESUMO

BACKGROUND: Prepubertal gynecomastia is characterized by the presence of palpable uni- or bilateral breast tissue in boys without other signs of sexual maturation. It may be the endocrine expression of rare syndromes such as Peutz-Jeghers syndrome (PJS). This study aimed to evaluate the effectiveness of anastrozole and to describe an innovative surgical approach. METHODS: This report presents twins with PJS, bilateral prepubertal gynecomastia, and testicular multifocal calcifications. Both twins were treated with anastrozole for 2 years. After finishing treatment, both were followed before subcutaneous mastectomy was performed by the "modified" Webster technique. RESULTS: Growth velocity decreased and gynecomastia diminished during anastrozole treatment. After discontinuation of therapy due to a sharp reduction in growth velocity, both twins showed regrowth of gynecomastia, with painful and strained breasts. A significant reduction in breast volume with glandular removal was achieved. CONCLUSIONS: The findings of this study showed a multidisciplinary approach to prepubertal gynecomastia due to the synergy of pediatricians, radiologists, and plastic surgeons. The follow-up evaluation after the anastrozole treatment showed it to be an efficacious medical treatment, as an alternative to orchidectomy, to control the effects of circulating estrogens. Moreover, the results observed in the patients confirmed the validity and feasibility of the "modified" Webster technique in terms of aesthetic and functional results, patient satisfaction, and absence of complications.


Assuntos
Inibidores da Aromatase/uso terapêutico , Doenças em Gêmeos/terapia , Ginecomastia/terapia , Mastectomia Subcutânea , Nitrilas/uso terapêutico , Triazóis/uso terapêutico , Glândulas Suprarrenais/diagnóstico por imagem , Anastrozol , Inibidores da Aromatase/administração & dosagem , Criança , Terapia Combinada , Comorbidade , Ginecomastia/sangue , Ginecomastia/complicações , Ginecomastia/diagnóstico por imagem , Humanos , Litíase/patologia , Masculino , Mastectomia Subcutânea/métodos , Nitrilas/administração & dosagem , Síndrome de Peutz-Jeghers/sangue , Síndrome de Peutz-Jeghers/complicações , Recidiva , Doenças Testiculares/diagnóstico por imagem , Doenças Testiculares/epidemiologia , Doenças Testiculares/patologia , Testículo/diagnóstico por imagem , Testículo/patologia , Triazóis/administração & dosagem , Ultrassonografia Mamária
16.
J Pers Med ; 13(5)2023 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-37241032

RESUMO

Breast cancer is the most common and most commonly diagnosed non-skin cancer in women. There are several risk factors related to habits and heredity, and screening is essential to reduce the incidence of mortality. Thanks to screening and increased awareness among women, most breast cancers are diagnosed at an early stage, increasing the chances of cure and survival. Regular screening is essential. Mammography is currently the gold standard for breast cancer diagnosis. In mammography, we can encounter problems with the sensitivity of the instrument; in fact, in the case of a high density of glands, the ability to detect small masses is reduced. In fact, in some cases, the lesion may not be particularly evident, it may be hidden, and it is possible to incur false negatives as partial details that may escape the radiologist's eye. The problem is, therefore, substantial, and it makes sense to look for techniques that can increase the quality of diagnosis. In recent years, innovative techniques based on artificial intelligence have been used in this regard, which are able to see where the human eye cannot reach. In this paper, we can see the application of radiomics in mammography.

17.
Bioengineering (Basel) ; 10(12)2023 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-38135998

RESUMO

Lymphedema is a progressive chronic condition affecting approximately 250 million people worldwide, a number that is currently underestimated. In Western countries, the most common form of lymphedema of the extremities is cancer-related and less radical surgical intervention is the main option to prevent it. Standardized protocols in the areas of diagnosis, staging and treatment are strongly required to address this issue. The aim of this study is to review the main diagnostic methods, comparing new emerging procedures to lymphoscintigraphy, considered as the golden standard to date. The roles of Magnetic Resonance Lymphangiography (MRL) or indocyanine green ICG lymphography are particularly reviewed in order to evaluate diagnostic accuracy, potential associations with lymphoscintigraphy, and future directions guided by AI protocols. The use of imaging to treat lymphedema has benefited from new techniques in the area of lymphatic vessels anatomy; these perspectives have become of value in many clinical scenarios to prevent cancer-related lymphedema.

18.
Diagnostics (Basel) ; 13(23)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38066823

RESUMO

One of the most frequently detected neoplasms in women in Italy is breast cancer, for which high-sensitivity diagnostic techniques are essential for early diagnosis in order to minimize mortality rates. As addressed in Part I of this work, we have seen how conditions such as high glandular density or limitations related to mammographic sensitivity have driven the optimization of technology and the use of increasingly advanced and specific diagnostic methodologies. While the first part focused on analyzing the use of a mammography machine from a physical and dosimetric perspective, in this paper, we will examine other techniques commonly used in breast imaging: contrast-enhanced mammography, digital breast tomosynthesis, radio imaging, and include some notes on image processing. We will also explore the differences between these various techniques to provide a comprehensive overview of breast lesion detection techniques. We will examine the strengths and weaknesses of different diagnostic modalities and observe how, with the implementation of improvements over time, increasingly effective diagnoses can be achieved.

19.
Diagnostics (Basel) ; 13(20)2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37892053

RESUMO

Breast cancer is the most frequently diagnosed neoplasm in women in Italy. There are several risk factors, but thanks to screening and increased awareness, most breast cancers are diagnosed at an early stage when surgical treatment can most often be conservative and the adopted therapy is more effective. Regular screening is essential but advanced technology is needed to achieve quality diagnoses. Mammography is the gold standard for early detection of breast cancer. It is a specialized technique for detecting breast cancer and, thus, distinguishing normal tissue from cancerous breast tissue. Mammography techniques are based on physical principles: through the proper use of X-rays, the structures of different tissues can be observed. This first part of the paper attempts to explain the physical principles used in mammography. In particular, we will see how a mammogram is composed and what physical principles are used to obtain diagnostic images.

20.
Curr Oncol ; 30(1): 839-853, 2023 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-36661713

RESUMO

BACKGROUND: breast cancer (BC) is the world's most prevalent cancer in the female population, with 2.3 million new cases diagnosed worldwide in 2020. The great efforts made to set screening campaigns, early detection programs, and increasingly targeted treatments led to significant improvement in patients' survival. The Full-Field Digital Mammograph (FFDM) is considered the gold standard method for the early diagnosis of BC. From several previous studies, it has emerged that breast density (BD) is a risk factor in the development of BC, affecting the periodicity of screening plans present today at an international level. OBJECTIVE: in this study, the focus is the development of mammographic image processing techniques that allow the extraction of indicators derived from textural patterns of the mammary parenchyma indicative of BD risk factors. METHODS: a total of 168 patients were enrolled in the internal training and test set while a total of 51 patients were enrolled to compose the external validation cohort. Different Machine Learning (ML) techniques have been employed to classify breasts based on the values of the tissue density. Textural features were extracted only from breast parenchyma with which to train classifiers, thanks to the aid of ML algorithms. RESULTS: the accuracy of different tested classifiers varied between 74.15% and 93.55%. The best results were reached by a Support Vector Machine (accuracy of 93.55% and a percentage of true positives and negatives equal to TPP = 94.44% and TNP = 92.31%). The best accuracy was not influenced by the choice of the features selection approach. Considering the external validation cohort, the SVM, as the best classifier with the 7 features selected by a wrapper method, showed an accuracy of 0.95, a sensitivity of 0.96, and a specificity of 0.90. CONCLUSIONS: our preliminary results showed that the Radiomics analysis and ML approach allow us to objectively identify BD.


Assuntos
Densidade da Mama , Neoplasias da Mama , Feminino , Humanos , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Aprendizado de Máquina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA