Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Biol Chem ; 295(32): 10926-10939, 2020 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-32471866

RESUMO

Chemokines mediate leukocyte migration and homeostasis and are key targets in inflammatory diseases including atherosclerosis, cytokine storm, and chronic autoimmune disease. Chemokine redundancy and ensuing network robustness has frustrated therapeutic development. Salivary evasins from ticks bind multiple chemokines to overcome redundancy and are effective in several preclinical disease models. Their clinical development has not progressed because of concerns regarding potential immunogenicity, parenteral delivery, and cost. Peptides mimicking protein activity can overcome the perceived limitations of therapeutic proteins. Here we show that peptides possessing multiple chemokine-binding and anti-inflammatory activities can be developed from the chemokine-binding site of an evasin. We used hydrogen-deuterium exchange MS to map the binding interface of the evasin P672 that physically interacts with C-C motif chemokine ligand (CCL) 8 and synthesized a 16-mer peptide (BK1.1) based on this interface region in evasin P672. Fluorescent polarization and native MS approaches showed that BK1.1 binds CCL8, CCL7, and CCL18 and disrupts CCL8 homodimerization. We show that a BK1.1 derivative, BK1.3, has substantially improved ability to disrupt P672 binding to CCL8, CCL2, and CCL3 in an AlphaScreen assay. Using isothermal titration calorimetry, we show that BK1.3 directly binds CCL8. BK1.3 also has substantially improved ability to inhibit CCL8, CCL7, CCL2, and CCL3 chemotactic function in vitro We show that local as well as systemic administration of BK1.3 potently blocks inflammation in vivo Identification and characterization of the chemokine-binding interface of evasins could thus inspire the development of novel anti-inflammatory peptides that therapeutically target the chemokine network in inflammatory diseases.


Assuntos
Anti-Inflamatórios/química , Quimiocina CCL8/metabolismo , Peptídeos/química , Engenharia de Proteínas , Receptores de Quimiocinas/metabolismo , Sequência de Aminoácidos , Animais , Anti-Inflamatórios/farmacologia , Dimerização , Humanos , Espectrometria de Massas/métodos , Peptídeos/farmacologia , Ligação Proteica , Homologia de Sequência de Aminoácidos , Carrapatos/metabolismo
2.
J Proteome Res ; 18(11): 4013-4019, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31545043

RESUMO

A top-down proteomic strategy with semiautomated analysis of data sets has proven successful for the global identification of truncated proteins without the use of chemical derivatization, enzymatic manipulation, immunoprecipitation, or other enrichment. This approach provides the reliable identification of internal polypeptides formed from precursor gene products by proteolytic cleavage of both the N- and C-termini, as well as truncated proteoforms that retain one or the other termini. The strategy has been evaluated by application to the immunosuppressive extracellular vesicles released by myeloid-derived suppressor cells. More than 1000 truncated proteoforms have been identified, from which binding motifs are derived to allow characterization of the putative proteases responsible for truncation.


Assuntos
Peptídeos/metabolismo , Processamento de Proteína Pós-Traducional , Proteoma/metabolismo , Proteômica/métodos , Sequência de Aminoácidos , Animais , Linhagem Celular Tumoral , Cromatografia Líquida/métodos , Vesículas Extracelulares/metabolismo , Humanos , Camundongos , Peptídeos/genética , Proteólise , Proteoma/genética , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
3.
J Biol Chem ; 293(16): 6134-6146, 2018 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-29487134

RESUMO

Tick chemokine-binding proteins (evasins) are an emerging class of biologicals that target multiple chemokines and show anti-inflammatory activities in preclinical disease models. Using yeast surface display, we identified a CCL8-binding evasin, P672, from the tick Rhipicephalus pulchellus We found that P672 binds CCL8 and eight other CC-class chemokines with a Kd < 10 nm and four other CC chemokines with a Kd between 10 and 100 nm and neutralizes CCL3, CCL3L1, and CCL8 with an IC50 < 10 nm The CC chemokine-binding profile was distinct from that of evasin 1 (EVA1), which does not bind CCL8. We also show that P672's binding activity can be markedly modulated by the location of a StrepII-His purification tag. Combining native MS and bottom-up proteomics, we further demonstrated that P672 is glycosylated and forms a 1:1 complex with CCL8, disrupting CCL8 homodimerization. Homology modeling of P672 using the crystal structure of the EVA1 and CCL3 complex as template suggested that 44 N-terminal residues of P672 form most of the contacts with CCL8. Replacing the 29 N-terminal residues of EVA1 with the 44 N-terminal residues of P672 enabled this hybrid evasin to bind and neutralize CCL8, indicating that the CCL8-binding properties of P672 reside, in part, in its N-terminal residues. This study shows that the function of certain tick evasins can be manipulated simply by adding a tag. We conclude that homology modeling helps identify regions with transportable chemokine-binding functions within evasins, which can be used to construct hybrid evasins with altered properties.


Assuntos
Proteínas de Artrópodes/metabolismo , Quimiocinas/metabolismo , Receptores de Quimiocinas/metabolismo , Carrapatos/metabolismo , Animais , Proteínas de Artrópodes/química , Proteínas de Artrópodes/genética , Glicosilação , Humanos , Modelos Moleculares , Ligação Proteica , Conformação Proteica , Receptores de Quimiocinas/química , Receptores de Quimiocinas/genética , Saccharomyces cerevisiae/genética , Espectrometria de Massas em Tandem
4.
J Proteome Res ; 17(1): 486-498, 2018 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-29139296

RESUMO

Myeloid-derived suppressor cells (MDSC) are immature myeloid cells that accumulate in the circulation and the tumor microenvironment of most cancer patients. There, MDSC suppress both adaptive and innate immunity, hindering immunotherapies. The inflammatory milieu often present in cancers facilitates MDSC suppressive activity, causing aggressive tumor progression and metastasis. MDSC from tumor-bearing mice release exosomes, which carry biologically active proteins and mediate some of the immunosuppressive functions characteristic of MDSC. Studies on other cell types have shown that exosomes may also carry RNAs which can be transferred to local and distant cells, yet the mRNA and microRNA cargo of MDSC-derived exosomes has not been studied to date. Here, the cargo of MDSC and their exosomes was interrogated with the goal of identifying and characterizing molecules that may facilitate MDSC suppressive potency. Because inflammation is an established driving force for MDSC suppressive activity, we used the well-established 4T1 mouse mammary carcinoma system, which includes "conventional" as well as "inflammatory" MDSC. We provide evidence that MDSC-derived exosomes carry proteins, mRNAs, and microRNAs with different quantitative profiles than those of their parental cells. Several of these molecules have known or predicted functions consistent with MDSC suppressive activity, suggesting a potential mechanistic redundancy.


Assuntos
Exossomos/química , Células Supressoras Mieloides/química , Animais , Exossomos/imunologia , Exossomos/fisiologia , Imunidade , Inflamação , Camundongos , MicroRNAs/análise , Células Supressoras Mieloides/imunologia , Células Supressoras Mieloides/fisiologia , Proteínas/análise , RNA Mensageiro/análise
5.
Anal Chem ; 88(22): 10900-10907, 2016 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-27748581

RESUMO

Spectral counting is a straightforward label-free quantitation strategy used in bottom-up proteomics workflows. The application of spectral counting in label-free top-down proteomics workflows can be similarly straightforward but has not been applied as widely as quantitation by chromatographic peak areas or peak intensities. In this study, we evaluate spectral counting for quantitative comparisons in label-free top-down proteomics workflows by comparison with chromatographic peak areas and intensities. We tested these quantitation approaches by spiking standard proteins into a complex protein background and comparing relative quantitation by spectral counts with normalized chromatographic peak areas and peak intensities from deconvoluted extracted ion chromatograms of the spiked proteins. Ratio estimates and statistical significance of differential abundance from each quantitation technique are evaluated against the expected ratios and each other. In this experiment, spectral counting was able to detect differential abundance of spiked proteins for expected ratios ≥2, with comparable or higher sensitivity than normalized areas and intensities. We also found that while ratio estimates using peak areas and intensities are usually more accurate, the spectral-counting-based estimates are not substantially worse. Following the evaluation and comparison of these label-free top-down quantitation strategies using spiked proteins, spectral counting, along with normalized chromatographic peak areas and intensities, were used to analyze the complex protein cargo of exosomes shed by myeloid-derived suppressor cells collected under high and low conditions of inflammation, revealing statistically significant differences in abundance for several proteoforms, including the active pro-inflammatory proteins S100A8 and S100A9.


Assuntos
Calgranulina A/análise , Calgranulina B/análise , Proteômica , Animais , Linhagem Celular Tumoral , Cromatografia Líquida , Biologia Computacional , Espectrometria de Massas , Camundongos
6.
Rapid Commun Mass Spectrom ; 29(8): 719-29, 2015 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-26406486

RESUMO

RATIONALE: Analysis for identification and quantification of regulated veterinary drug residues in foods is usually achieved by liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS). The instrumental method requires the selection of characteristic ions, but structural elucidation is seldom performed to help ensure accuracy. This study is a continuation of previous work to characterize selected product ions in support of regulatory monitoring programs. METHODS: The tandem mass spectra of 28 veterinary drugs from a previously published LC/MS/MS method were acquired with a high-resolution quadrupole time-of-flight (Q-TOF) mass spectrometer using electrospray ionization (ESI) in positive mode. The TOF analyzer was calibrated to achieve a mass accuracy error <5 ppm for the MS and MS/MS modes, and samples were infused for data acquisition. RESULTS: The high mass accuracy achieved in Q-TOF allowed elucidation of the formulae of the product ions previously selected for qualitative identification. Rational interpretation of results was made and compared with the published literature, and the structure for the MS/MS product ions of four classes of regulated drugs (mectins, benzimidazoles, nitroimidazoles, and phenothiazines), totaling 28 compounds, were examined leading to the report of new structures or confirmation of published structures using low-resolution MS. CONCLUSIONS: Structural characterization of the product ions selected for identification and quantification of veterinary drug residues is important information for regulatory monitoring programs in defense of regulatory enforcement actions. This study has allowed structural elucidation of 84 MS/MS product ions previously selected for the LC/MS/MS analysis of 28 drug analytes.


Assuntos
Resíduos de Drogas/análise , Análise de Alimentos/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Drogas Veterinárias/análise , Benzimidazóis/análise , Nitroimidazóis/análise , Fenotiazinas/análise , Espectrometria de Massas em Tandem/métodos
7.
Int J Mass Spectrom ; 378: 264-269, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25937807

RESUMO

Top-down analysis is reported for a portion of the protein cargo of exosomes shed by myeloid-derived suppressor cells that participate in intracellular signaling in the tumor microenvironment. Instrument mass resolution limited the study to proteins of molecular masses below 30 kDa. A two-step fractionation strategy was used, including open tubular gel electrophoresis and C3 reverse phase high performance liquid chromatography. Twenty-one unique proteins were identified among more than 200 proteoforms, and comprising primarily two functionally important protein families: the S100 proinflammatory mediators and an abundance of histones. Fifty-six percent of the total protein in these exosomes was determined to comprise histones, of which H2B variants contribute 42 %.

8.
Rapid Commun Mass Spectrom ; 28(10): 1061-81, 2014 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-24711270

RESUMO

RATIONALE: Monitoring of veterinary drug residues in foods is often conducted using liquid chromatography/tandem mass spectrometry (LC/MS/MS). Results have high economic stakes for producers, but the ions monitored are usually selected due to signal intensities without structural interpretation. In this study, the ion transitions were characterized by high-resolution mass spectrometry. METHODS: The 62 veterinary drugs from the LC/MS/MS method consisted of sulfonamides, ß-lactams, phenicols, macrolides, tetracyclines, fluoroquinolones, non-steroidal anti-inflammatory drugs (NSAIDs), and corticosteroids. They were individually infused into a quadrupole time-of-flight (Q-TOF) mass spectrometer using electrospray ionization (ESI) operated in positive mode. The MS and collision-induced dissociation (CID) MS/MS spectra for each analyte were obtained for structural elucidation. The Q-TOF instrument was calibrated to obtain a mass accuracy error <5 ppm for the MS and MS/MS spectra. RESULTS: The use of high-resolution ESI-Q-TOF-MS for the generation of the MS/MS product ions allowed for the determination of chemical formulae for the analytes, some of which led to new findings. Assigned structures were based on rational interpretation of the most stable possible products with comparison with the scientific literature. In difficult cases, isotopically labeled drugs or hydrogen/deuterium (H/D) exchange experiments were used to help confirm the structures of the product ions. CONCLUSIONS: The use of ESI-Q-TOF-MS in this study has allowed structure elucidation of 186 MS/MS product ions previously selected for the LC/MS/MS analysis of 62 veterinary drugs. This serves to reduce the chances of false positives and negatives in the monitoring program, and provides justification and defense in regulatory enforcement actions.


Assuntos
Resíduos de Drogas/química , Análise de Alimentos/métodos , Íons/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Drogas Veterinárias/química , Resíduos de Drogas/análise , Íons/análise , Modelos Moleculares , Drogas Veterinárias/análise
9.
J AOAC Int ; 95(5): 1311-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23175960

RESUMO

Despite its many documented advantages, the QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) sample preparation approach has problems with a few unstable pesticides, partly due to the exothermic reaction generated by the use of anhydrous magnesium sulfate (anh. MgSO4) during extraction. These pesticides also tend to be difficult to analyze by GC/MS. The aim of this study was to evaluate the effect of temperature during the extraction process in a revised version of AOAC Official Method 2007.01 using anh. MgSO4 > or = 99% (fine powder) or > or = 97% (granular) purity, and the use of an ice bath for particular unstable pesticides of interest (chlorothalonil, captan, captafol, folpet, and the degradation products cis-1,2,3,6-tetrahydrophthalimide and phthalimide). Recoveries of 38 representative pesticides were measured in limes and broccoli at different extraction conditions by LC/MS/MS and low-pressure GC/MS/MS. Results showed that the difference in temperature when using > or = 99% versus > or = 97% purity anh. MgSO4 was 6-9 degrees C, which did not lead to significant differences in recoveries. The use of an ice bath aided recovery for some of the analytes in broccoli, but no significant differences were observed for limes, which already provided greater stability of the base-sensitive analytes due to acidity of the matrix.


Assuntos
Fracionamento Químico/métodos , Sulfato de Magnésio/química , Resíduos de Praguicidas/química , Praguicidas/química , Temperatura , Brassica/química , Citrus aurantiifolia/química , Contaminação de Alimentos , Frutas/química
10.
ScientificWorldJournal ; 2012: 174837, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22619617

RESUMO

Herpes simplex virus type 1 (HSV-1) infection has a prevalence of 70% in the human population. Treatment is based on acyclovir, valacyclovir, and foscarnet, three drugs that share the same mechanism of action and of which resistant strains have been isolated from patients. In this aspect, innovative drug therapies are required. Natural products offer unlimited opportunities for the discovery of antiviral compounds. In this study, 28 extracts corresponding to 24 plant species and 4 alga species were assayed in vitro to detect antiviral activity against HSV-1. Six of the methanolic extracts inactivated viral particles by direct interaction and 14 presented antiviral activity when incubated with cells already infected. Most interesting antiviral activity values obtained are those of Limonium brasiliense, Psidium guajava, and Phyllanthus niruri, which inhibit HSV-1 replication in vitro with 50% effective concentration (EC(50)) values of 185, 118, and 60 µg/mL, respectively. For these extracts toxicity values were calculated and therefore selectivity indexes (SI) obtained. Further characterization of the bioactive components of antiviral plants will pave the way for the discovery of new compounds against HSV-1.


Assuntos
Antineoplásicos/farmacologia , Antivirais/farmacologia , Microalgas/química , Extratos Vegetais/farmacologia , Animais , Chlorocebus aethiops , Herpesvirus Humano 1/efeitos dos fármacos , Herpesvirus Humano 1/fisiologia , América do Sul , Células Vero , Replicação Viral/efeitos dos fármacos
11.
Anal Bioanal Chem ; 401(8): 2617-30, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21881880

RESUMO

Microcystins (MCs) are the most common cyanotoxins found worldwide in freshwater, brackish, and marine environments. The rapid and accurate analysis of MCs and nodularin (Nod-R) in fish tissue is important for determining occurrence, following trends, and monitoring exposure for risk assessment and other purposes. The aim of this study was to develop a streamlined and reliable sample preparation method for eight MCs (MC-RR, MC-YR, MC-LR, MC-WR, MC-LA, MC-LY, MC-LW, and MC-LF) and Nod-R in fish, and conduct a validation of the new method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for analysis and compare the results with a commercial enzyme-linked immunosorbent assay (ELISA) kit. Different sample preparation methods were compared, and a simple extraction protocol with acidified acetonitrile/water (3:1) followed by hexane partitioning cleanup was found to be most effective. Thorough validation of the final method was conducted, and 90-115% recoveries were achieved for all analytes except for MC-RR, which gave 130% average recovery (isotopically labeled internal standards were unavailable to correct for possible biases). The use of electrospray ionization in the negative mode gave few interferences and minimal matrix effects in the LC-MS/MS analysis overall. Precision was typically 10-20% RSD among multiple days in experiments, detection limits were <10 ng/g in the fish tissue (catfish, basa, and swai filets), and no false-positives or false-negatives occurred in blind analyses of many spiked samples. The ELISA was unable to distinguish between MCs but was found to correctly assess the presence or absence of MCs and Nod-R in the blind-fortified fish tissues. The capability of these approaches to measure covalently bound MCs was not assessed.


Assuntos
Peixes/metabolismo , Microcistinas/análise , Espectrometria de Massas em Tandem/métodos , Animais , Cromatografia Líquida/métodos , Ensaio de Imunoadsorção Enzimática , Limite de Detecção
12.
J Environ Sci Health B ; 45(8): 796-803, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20954047

RESUMO

In order to evaluate the extraction of pesticide residues that are transferred to the brew during mate drinking process of P.U.1 yerba mate leaves (Ilex paraguariensis), a special device to simulate the way in which mate is drunk in Uruguay was developed. The transfer to the brew of 12 organophosphates, 5 synthethic pyrethroids and one organochlorine pesticide from spiked samples was studied. The relationship between the transfer data thus obtained and physicochemical properties like water solubility (Ws), octanol-water coefficient (Kow) and Henry's constant (H) was evaluated. The extractability of the pesticide residues from yerba mate can be correlated with log Ws and log Kow. These transfer values allowed the calculation of ARLs (acceptable residue level) for the pesticides following Food and Agriculture Organization (FAO), World Health Organizaion (WHO) guidelines. These results can help the future establishment of maximum residue levels (MRLs).


Assuntos
Bebidas/análise , Ingestão de Líquidos , Ilex paraguariensis/química , Resíduos de Praguicidas/química , Fenômenos Químicos , Humanos , Folhas de Planta/química , Uruguai
13.
Methods Enzymol ; 626: 323-346, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31606081

RESUMO

The small protein ubiquitin and its multiple polymers are encountered free in cells and as post-translational modifications on all proteins. Different polyubiquitin three dimensional structures are shown to correlate uniquely with different cellular functions as part of the diverse ubiquitin signaling. At the same time, this multiplicity of structures provides serious challenges to the analytical biochemist. Globally applicable strategies are presented here for the analyses of polyubiquitins and of ubiquitinated proteins, which take advantage of the speed, specificity and sensitivity of top-down tandem mass spectrometry. Particular attention is given to the supervised interpretation of fragmentation as revealed in the MS/MS spectra of these branched proteins. The strategy is compatible with any MS activation technology, is applicable to all polyubiquitin linkage and chain types, can be extended to ubiquitin-like proteins, and will be compatible with and enhanced by continuing advances in LC-MS/MS instrumentation and interpretation software.


Assuntos
Poliubiquitina/química , Espectrometria de Massas em Tandem/métodos , Ubiquitina/análise , Proteínas Ubiquitinadas/química , Ubiquitinação , Sequência de Aminoácidos , Animais , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Conformação Proteica , Multimerização Proteica
14.
Cell Rep ; 25(1): 259-269.e5, 2018 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-30282034

RESUMO

Termination of RNA polymerase II (Pol II) transcription is a key step that is important for 3' end formation of functional mRNA, mRNA release, and Pol II recycling. Even so, the underlying termination mechanism is not yet understood. Here, we demonstrate that the conserved and essential termination factor Seb1 is found on Pol II near the end of the RNA exit channel and the Rpb4/7 stalk. Furthermore, the Seb1 interaction surface with Pol II largely overlaps with that of the elongation factor Spt5. Notably, Seb1 co-transcriptional recruitment is dependent on Spt5 dephosphorylation by the conserved PP1 phosphatase Dis2, which also dephosphorylates threonine 4 within the Pol II heptad repeated C-terminal domain. We propose that Dis2 orchestrates the transition from elongation to termination phase during the transcription cycle by mediating elongation to termination factor exchange and dephosphorylation of Pol II C-terminal domain.


Assuntos
Fatores de Alongamento de Peptídeos/genética , RNA Polimerase II/metabolismo , Proteínas de Schizosaccharomyces pombe/metabolismo , Schizosaccharomyces/metabolismo , Fatores de Transcrição/genética , Terminação da Transcrição Genética/fisiologia , Transcrição Gênica/genética
15.
J Mass Spectrom ; 51(8): 629-637, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28239975

RESUMO

The characterization of polyubiquitin chains has been an analytical challenge for several decades. It has been shown that anchored and unanchored polyubiquitin chains with different isopeptide linkages and lengths exhibit a wide range of profoundly different cellular functions. However, structure function studies have been hindered by the difficulty of characterizing these complex chain structures. This report presents a broadly applicable workflow to characterize ubiquitin tetramers without the need for genetic mutations or reiterative immunoprecipitations. We use a top-down proteomic strategy that exploits ETciD activation on an orbitrap Fusion Lumos and manual interpretation aided by graphical interpretation of mass shifts to facilitate characterization of chain topography and lysine linkage sites. Our workflow differentiates all topological features of the numerous isomers of tetraubiquitin, which have molecular masses in excess of 34 000 Da and identifies linkage sites in these branched proteins. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Proteômica/métodos , Ubiquitina/análise , Ubiquitina/química , Sequência de Aminoácidos , Cromatografia Líquida , Isomerismo , Subunidades Proteicas/análise , Subunidades Proteicas/química , Análise de Sequência de Proteína , Espectrometria de Massas em Tandem
16.
J Mass Spectrom ; 51(4): 315-21, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27041663

RESUMO

The profound effects of ubiquitination on the movement and processing of cellular proteins depend exquisitely on the structures of monoubiquitin and polyubiquitin modifications. Unconjugated polyubiquitins also have a variety of intracellular functions. Structures and functions are not well correlated yet, because the structures of polyubiquitins and polyubiquitin modifications of proteins are difficult to decipher. We are moving towards a robust strategy to provide that structural information. In this report electron transfer dissociation mass spectra of six synthetic ubiquitin trimers (multiply branched proteins with molecular masses exceeding 25,600 Da) are examined using an Orbitrap Fusion Lumos instrument to determine how top-down mass spectrometry can characterize the chain topology and linkage sites in a single, facile workflow. The efficacy of this method relies on the formation, detection, and interpretation of extensive fragmentation.


Assuntos
Multimerização Proteica , Ubiquitina/química , Sequência de Aminoácidos , Poliubiquitina/química , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem
17.
Artigo em Inglês | MEDLINE | ID: mdl-24224899

RESUMO

This study analysed 22 strawberry and soil samples after their collection over the course of 2 years to compare the residue profiles from organic farming with integrated pest management practices in Portugal. For sample preparation, we used the citrate-buffered version of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. We applied three different methods for analysis: (1) 27 pesticides were targeted using LC-MS/MS; (2) 143 were targeted using low pressure GC-tandem mass spectrometry (LP-GC-MS/MS); and (3) more than 600 pesticides were screened in a targeted and untargeted approach using comprehensive, two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOF-MS). Comparison was made of the analyses using the different methods for the shared samples. The results were similar, thereby providing satisfactory confirmation of both similarly positive and negative findings. No pesticides were found in the organic-farmed samples. In samples from integrated pest management practices, nine pesticides were determined and confirmed to be present, ranging from 2 µg kg(-1) for fluazifop-p-butyl to 50 µg kg(-1) for fenpropathrin. Concentrations of residues in strawberries were less than European maximum residue limits.


Assuntos
Cromatografia Gasosa/métodos , Cromatografia Líquida/métodos , Fragaria/química , Resíduos de Praguicidas/química , Solo/química , Espectrometria de Massas em Tandem/métodos , Agricultura/métodos , Controle de Pragas/métodos
18.
J Chromatogr A ; 1270: 235-45, 2012 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-23182936

RESUMO

Gas and liquid chromatography (GC and LC) coupled to mass spectrometry (MS) serve as the most powerful analytical tools commonly used to monitor pesticide residues in food, among other applications. However, both GC-MS and LC-MS are susceptible to matrix effects which can adversely affect quantification depending on the analyte, matrix, sample preparation, instrumentation, and operating conditions. Among the approaches that reduce matrix effects, the most common in pesticide residue applications is matrix-matched calibration because it is relatively inexpensive and simple. Also, it has been shown to work well during method validation when fortified samples are exactly matched with samples used for calibration. However, the quality of matrix-matched results in real-world analyses depends on the consistency of matrix effects among diverse samples. In this study, the variability of matrix effects was measured for 38 representative pesticides in 20 samples each (including different varieties) of rice, orange, apple, and spinach extracted using the "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) method for analysis by LC-MS/MS and low-pressure GC-MS. Using LC-MS/MS, only oranges gave >20% matrix effects for a few pesticides. GC-MS exhibited larger matrix effects, but as in LC-MS/MS, the differences were reasonably consistent among the 20 samples tested. Main conclusions of this study are that for the conditions utilized: (1) matrix-matching was not needed for most pesticides in the simpler food matrices; and (2) for the more complex orange matrix, acceptably accurate quantitative results were achieved by using matrix-matching even with a different sample of the same type. However, full confidence cannot be extended to matrix-matched results, and for consequential applications such as regulatory enforcement, confirmatory analyses using alternate quantitative determinations should also be conducted.


Assuntos
Cromatografia Líquida/métodos , Frutas/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Resíduos de Praguicidas/análise , Plantas Comestíveis/química , Cromatografia Gasosa-Espectrometria de Massas/normas , Modelos Lineares , Padrões de Referência , Reprodutibilidade dos Testes , Fatores de Tempo
19.
J Chromatogr A ; 1258: 43-54, 2012 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-22944383

RESUMO

In this study, optimization, extension, and validation of a streamlined, qualitative and quantitative multiclass, multiresidue method was conducted to monitor >100 veterinary drug residues in meat using ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Optimization centered on extensive ruggedness evaluation of the method. Various clean-up sorbents were tested and the amount of co-extractives were weighed, matrix effects were measured using post-column infusion of representative analytes, the effect of extract dilution before injecting was studied, and analyte recoveries and reproducibilities were determined. In order to extend our previous method, more drug analytes were added that possessed a wider range of chemical properties, and a re-appraisal of different types of C18 in dispersive solid-phase extraction clean-up and mobile phases in UHPLC-MS/MS was done. Ultimately, end-capped C18 and post-column infusion of ammonium formate as an ionization enhancer for the late-eluting anthelmintics were found to give improved qualitative results for greater analytical scope. A multi-day, multi-analyst validation demonstrated that the final method is suitable for screening of 113 analytes, identifying 98 and quantifying (recoveries between 70-120% and RSD<25%) 87 out of the 127 tested drugs at or below US regulatory tolerance levels in bovine muscle.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Resíduos de Drogas/análise , Carne/análise , Músculos/química , Espectrometria de Massas em Tandem/métodos , Drogas Veterinárias/análise , Animais , Anti-Helmínticos/análise , Anti-Helmínticos/isolamento & purificação , Bovinos , Resíduos de Drogas/isolamento & purificação , Reprodutibilidade dos Testes , Extração em Fase Sólida , Drogas Veterinárias/isolamento & purificação
20.
Drug Test Anal ; 4 Suppl 1: 75-90, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22851364

RESUMO

In the USA, the US Department of Agriculture's Food Safety and Inspection Service (FSIS) conducts the National Residue Program designed to monitor veterinary drug and other chemical residues in beef and other slaughtered food animals. Currently, FSIS uses a 7-plate bioassay in the laboratory to screen for antimicrobial drugs in bovine kidneys from those animals tested positive by inspectors in the slaughter establishments. The microbial inhibition bioassay has several limitations in terms of monitoring scope, sensitivity, selectivity, and analysis time. Ultra-high performance liquid chromatography - tandem mass spectrometry (UHPLC-MS/MS) has many advantages over the bioassay for this application, and this study was designed to develop, evaluate, and validate a fast UHPLC-MS/MS method for antibiotics and other high-priority veterinary drugs in bovine kidney. Five existing multi-class, multi-residue methods from the literature were tested and compared, and each performed similarly. Experiments with incurred samples demonstrated that a 5-min shake of 2 g homogenized kidney with 10 ml of 4/1 (v/v) acetonitrile/water followed by simultaneous clean-up of the initial extract with 0.5 g C18 and 10 ml hexane gave a fast, simple, and effective sample preparation method for the <10 min UHPLC-MS/MS analysis. An extensive 5-day validation process demonstrated that the final method could be used to acceptably screen for 54 of the 62 drugs tested, and 50 of those met qualitative MS identification criteria. Quantification was not needed in the application, but the method gave ≥ 70% recoveries and ≤ 25% reproducibilities for 30 of the drugs.


Assuntos
Resíduos de Drogas/análise , Rim/química , Carne/análise , Espectrometria de Massas em Tandem/métodos , Drogas Veterinárias/análise , Animais , Bovinos , Cromatografia Líquida de Alta Pressão/métodos , Contaminação de Alimentos/análise , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA