Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 21(14): 16584-604, 2013 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-23938510

RESUMO

We demonstrate a technique to improve structural data obtained from Optical Projection Tomography (OPT) using Image Fusion (IF) and contrast normalization. This enables the visualization of molecular expression patterns in biological specimens with highly variable contrast values. In the approach, termed IF-OPT, different exposures are fused by assigning weighted contrasts to each. When applied to projection images from mouse organs and digital phantoms our results demonstrate the capability of IF-OPT to reveal high and low signal intensity details in challenging specimens. We further provide measurements to highlight the benefits of the new algorithm in comparison to other similar methods.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Molecular/métodos , Reconhecimento Automatizado de Padrão/métodos , Técnica de Subtração , Tomografia Óptica/métodos , Animais , Camundongos
2.
J Vis Exp ; (71): e50238, 2013 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-23353681

RESUMO

By adapting OPT to include the capability of imaging in the near infrared (NIR) spectrum, we here illustrate the possibility to image larger bodies of pancreatic tissue, such as the rat pancreas, and to increase the number of channels (cell types) that may be studied in a single specimen. We further describe the implementation of a number of computational tools that provide: 1/ accurate positioning of a specimen's (in our case the pancreas) centre of mass (COM) at the axis of rotation (AR); 2/ improved algorithms for post-alignment tuning which prevents geometric distortions during the tomographic reconstruction and 3/ a protocol for intensity equalization to increase signal to noise ratios in OPT-based BCM determinations. In addition, we describe a sample holder that minimizes the risk for unintentional movements of the specimen during image acquisition. Together, these protocols enable assessments of BCM distribution and other features, to be performed throughout the volume of intact pancreata or other organs (e.g. in studies of islet transplantation), with a resolution down to the level of individual islets of Langerhans.


Assuntos
Diabetes Mellitus Experimental/patologia , Células Secretoras de Insulina/patologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Tomografia Óptica/métodos , Animais , Camundongos , Ratos
3.
IEEE Trans Med Imaging ; 31(1): 1-15, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21768046

RESUMO

Since it was first presented in 2002, optical projection tomography (OPT) has emerged as a powerful tool for the study of biomedical specimen on the mm to cm scale. In this paper, we present computational tools to further improve OPT image acquisition and tomographic reconstruction. More specifically, these methods provide: semi-automatic and precise positioning of a sample at the axis of rotation and a fast and robust algorithm for determination of postalignment values throughout the specimen as compared to existing methods. These tools are easily integrated for use with current commercial OPT scanners and should also be possible to implement in "home made" or experimental setups for OPT imaging. They generally contribute to increase acquisition speed and quality of OPT data and thereby significantly simplify and improve a number of three-dimensional and quantitative OPT based assessments.


Assuntos
Algoritmos , Artefatos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Óptica/métodos , Animais , Feminino , Insulina/química , Ilhotas Pancreáticas/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Modelos Teóricos , Imagens de Fantasmas
4.
Anal Chem ; 79(1): 335-44, 2007 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-17194158

RESUMO

A set of monolithic stationary phases representing a broad span of monomers and porogens have been characterized directly in their capillary chromatographic format by computational assessment of their pore structure from transmission electron micrographs obtained after in situ embedment of the monoliths in contrast resin, followed by dissolution of the fused-silica tubing, further encasement of the resin-embedded monolith, and microtomy. This technique has been compared to mercury intrusion, a more conventional technique for macroporosity estimation. Supplementing the embedding resin by lead methacrylate gave a negative staining, and the resulting micrographs showed a good contrast between the polymeric monoliths and the embedding resin that allowed studies on the pore formation and polymer development. The technique was also applied to a commercial monolithic silica column.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA