1.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36709469

RESUMO

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Assuntos
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedância Elétrica , Estudos Retrospectivos , Fibrilação Ventricular , Desfibriladores Implantáveis
2.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37350404

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Humanos , Administração Intravenosa , Antibacterianos , Hospitalização , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34252991

RESUMO

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado do Tratamento
4.
Neurol Sci ; 42(9): 3707-3714, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33443664

RESUMO

INTRODUCTION: Up to one-third of ischemic strokes remained cryptogenic despite extensive investigations. Atrial fibrillation may be detected in a significant proportion of patients with embolic stroke of undetermined source, particularly after the introduction of implantable loop recorder in clinical practice. METHODS: We retrospectively included all the consecutive patients with embolic stroke of undetermined source referred to our units in the period November 2013 to December 2018 and in which an implantable loop recorder was positioned within 6 months from stroke event. Prevalence and predictors of atrial fibrillation were investigated. RESULTS: One hundred thirty-eight patients with embolic stroke of undetermined source fulfilling inclusion criteria were identified. The crude prevalence of atrial fibrillation at the end of observation period was of 45.7%. Incidence rates at 6, 12, 18, 24, and 36 months resulted, respectively, 31.8% (95% CI, 30.4-46.7), 38.0% (95% CI, 30.4-46.9), 42.6% (95% CI, 34.5-51.6), 46.6% (95% CI, 38.2-55.8), and 50.4% (95% CI, 41.6-59.9). On multivariate analysis, only excessive supraventricular electric activity and left atrial enlargement resulted to be significant predictors of atrial fibrillation (p = 0.037 and p < 0.0001, respectively). CONCLUSIONS: Atrial fibrillation may be detected in a relevant proportion (up to 50%) of patients with embolic stroke of undetermined source if a careful and extensive diagnostic work-up is employed. Excessive supraventricular electric activity and left atrial enlargement are significant predictors of the occurrence of atrial fibrillation in these patients.


Assuntos
Fibrilação Atrial , AVC Embólico , Embolia Intracraniana , Acidente Vascular Cerebral , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Humanos , Embolia Intracraniana/epidemiologia , Prevalência , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
5.
J Cardiovasc Electrophysiol ; 31(5): 1166-1174, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32141116

RESUMO

INTRODUCTION: Early evidence suggests that multipoint left ventricular pacing (MPP) may improve response to cardiac resynchronization therapy (CRT). It is unknown whether this benefit is sustained and cost-effective. We used real-world data to evaluate long-term impact of MPP-ON clinical status, heart failure hospitalizations (HFH) and costs. METHODS: The Italian registry on multipoint left ventricular pacing is a prospective, multicenter registry of patients implanted with MPP-enabled CRT devices. For this analysis, clinical and echocardiographic data were collected through 24 months and compared between patients with (MPP-ON) or without (MPP-OFF) early MPP activation at implant. The total cost of each HFH was estimated with national Italian reimbursement rates. RESULTS: The study included 190 MPP-OFF and 128 MPP-ON patients with similar baseline characteristics. At 1 and 2 years, the MPP-ON group had lower rates of HFH vs MPP-OFF (1-year hazard ratio [HR]: 0.14, P = .0014; 2-year HR: 0.38, P = .009). The finding persisted in a subgroup of patients with consistent MPP activation through follow-up (1-year HR: 0.19; P = .0061; 2-year HR: 0.39, P = .022). Total HFH per-patient costs were lower in the MPP-ON vs the MPP-OFF group at 1 year (€101 ± 50 vs €698 ± 195, P < .001) and 2 years (€366 ± 149 vs €801 ± 203, P = .038). More MPP-ON patients had ≥5% improvement in ejection fraction (76.8% vs 65.4%, P = .025) and clinical composite score (66.7% vs 47.5%, P = .01). CONCLUSIONS: In this multicenter clinical study, early MPP activation was associated with a significant reduction in cumulative HFH and related costs after 1 and 2 years of follow-up.


Assuntos
Terapia de Ressincronização Cardíaca/economia , Custos de Cuidados de Saúde , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Redução de Custos , Análise Custo-Benefício , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Custos Hospitalares , Hospitalização/economia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
6.
Catheter Cardiovasc Interv ; 95(3): 522-529, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31385427

RESUMO

OBJECTIVES: Evaluate safety and efficacy of polymer-free biolimus-eluting stents (PF-BESs) versus ultrathin stents in unprotected left main (ULM) or bifurcation. BACKGROUND: PF-BESs due to reduced length of dual antiplatelet therapy (DAPT) are increasingly used. However, there are limited data about safety and efficacy for ULM or bifurcation. METHODS: We selected all-patients treated for ULM or bifurcation from two multicenter real life registries (RAIN [NCT03544294] evaluating ultrathin stents, CHANCE [NCT03622203] appraising PF-BES). After propensity score with matching, the primary endpoint was major adverse cardiac events (MACE; a composite of all-cause death, myocardial infarction, target lesion revascularization [TLR], and stent thrombosis [ST]), while its components along with target vessel revascularization (TVR) secondary endpoints. RESULTS: Three thousand and three patients treated with ultrathin stents and 446 with PF-BESs, resulting respectively in 562 and 281 after propensity score with matching (33 and 22%, respectively, with ULM disease). After 12 (8-20) months, rates of MACE were similar (9 vs. 8%, p = 0.56) without difference in TLR and ST (3.0 vs. 1.7%, p = .19 and 1.8 vs. 1.1%, p = .42). These results were consistent for ULM group (3 vs. 1.7% and 1.8 vs. 1.1%, p = .49 and .76), for non-ULM group (2.1 vs. 3.4%, p = .56 and 1.2 vs. 1.7%, p = .78) and for two-stent strategy (8.7 vs. 4.5% and 4.3 vs. 3.2%, p = .75 and .91). Among patients treated with 1 month of DAPT in both groups, those with ultrathin stents experienced higher rates of MACE related to all-cause death (22 vs. 12%, p = .04) with higher although not significant rates of ST (3 vs. 0%, p = .45). CONCLUSIONS: PF-BES implanted on ULM or BiF offered freedom from TLR and ST comparable to ultrathin stents. PF-BESs patients assuming DAPT for 1 month experienced a lower despite not significant incidence of ST.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Idoso de 80 Anos ou mais , Fármacos Cardiovasculares/efeitos adversos , Protocolos Clínicos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Pontuação de Propensão , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo
7.
J Cardiovasc Electrophysiol ; 30(12): 2885-2891, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31661172

RESUMO

BACKGROUND: Multipoint pacing (MPP) may improve clinical outcomes in patients with cardiac resynchronization therapy defibrillators (CRT-D), but its impact on battery longevity in a real-world population has not been investigated in large trials. OBJECTIVE: Compare projected battery longevity in CRT-D patients with and without MPP during long-term follow-up. METHODS: The Italian registry on multipoint left ventricular pacing (IRON-MPP) is a prospective, multicenter registry of patients implanted with MPP-capable CRT-D devices. Projected battery longevity during follow-up was compared for patients with MPP (MPP ON) vs single-site (MPP OFF) left ventricular pacing at CRT-D implantation. A sub-analysis excluded crossover patients with MPP activation or deactivation occurring after implantation. A second sub-analysis excluded patients with a right or left ventricular pacing amplitude >2.5 V. RESULTS: Out of 237 CRT-D patients (71 ± 9 years, 81% male) followed for 1.9 ± 0.8 years, 102 (43%) had MPP ON at implantation. Programmed atrial and ventricular outputs and percentage of pacing were similar between groups. MPP was associated with a 0.44 years reduction in projected battery longevity (P = .03) during long-term follow-up. Results were similar for the first and second sub-analyses, with a 0.57 years (P < .001) and 0.71 years (P < .001) reduction in projected longevity, respectively. CONCLUSION: In this long-term real-world registry, early MPP activation is associated with less than a 1-year reduction in projected battery life compared to single-site biventricular pacing.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Cardioversão Elétrica/instrumentação , Fontes de Energia Elétrica , Falha de Equipamento , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
8.
Europace ; 21(3): 502-510, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30508076

RESUMO

AIMS: Anatomical placement of the coronary sinus (CS) lead in basal or mid-ventricular positions of the posterior and lateral walls is associated with a better clinical outcome of cardiac resynchronization therapy (CRT). We hypothesized that optimization of CS lead placement targeted the right-to-left electrical delay (RLD) predicts an additional clinical benefit. METHODS AND RESULTS: The CS lead was placed according to current standards in 90 patients (Conventional group) and at the site of the longest RLD in 121 patients (RLD group). Non-responders were defined as those who died or underwent hospitalization for heart failure or did not improve in their Clinical Composite Score within 6 months. There were 67 (32%) non-responders. Compared with Conventional group, the final CS pacing site was more frequently in the basal segments in the RLD group (40% vs. 23%, P = 0.007); moreover, the RLD ratio (%RLD) of the total QRS width was longer (77 ± 13 vs. 73 ± 15, P = 0.05) and biventricular QRS shortened more from the baseline (-31 ± 21 ms vs. -21 ± 26 ms, P = 0.004). Nevertheless, the rate of non-responders was similar in the RLD and Conventional groups (35% vs. 28%, P = 0.30), as was %RLD (76 ± 16 vs. 75 ± 13, P = 0.66). QRS width during right ventricular (RV) pacing was an independent predictors of adverse outcome, with a 2% increase in the risk of failure for each 1 ms increase in QRS (P = 0.006). CONCLUSION: Optimization of CS lead placement targeted to latest electrical activation does not provide additional clinical benefit to anatomical placement in basal or mid-ventricular positions of the posterior and lateral walls. QRS width during RV pacing was a strong predictor of CRT failure. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique identifier: NCT03204864.


Assuntos
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Seio Coronário/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Progressão da Doença , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Estudos Prospectivos , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
N Engl J Med ; 383(1): 88-89, 2020 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-32343497
10.
Europace ; 19(7): 1170-1177, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27189954

RESUMO

AIMS: This registry was created to describe the experience of 76 Italian centres with a large cohort of recipients of multipoint pacing (MPP) capable cardiac resynchronization therapy (CRT) devices. METHODS AND RESULTS: A total of 507 patients in whom these devices had been successfully implanted were enrolled between August 2013 and May 2015. We analysed: (i) current clinical practices for the management of such patients, and (ii) the impact of MPP on heart failure clinical composite response and on the absolute change in ejection fraction (EF) at 6 months. Multipoint pacing was programmed to 'ON' in 46% of patients before discharge. Methods of optimizing MPP programming were most commonly based on either the greatest narrowing of the QRS complex (38%) or the electrical delays between the electrodes (34%). Clinical and echocardiographic follow-up data were evaluated in 232 patients. These patients were divided into two groups according to whether MPP was programmed to 'ON' (n = 94) or 'OFF' (n = 138) at the time of discharge. At 6 months, EF was significantly higher in the MPP group than in the biventricular-pacing group (39.1 ± 9.6 vs. 34.7 ± 7.6%; P < 0.001). Even after adjustments, early MPP activation remained an independent predictor of absolute increase in LVEF of ≥5% (odds ratio 2.5; P = 0.001). At 6 months, an improvement in clinical composite score was recorded in a greater proportion of patients with MPP-ON than in controls (56 vs. 38%; P = 0.009). On comparing optimal MPP and conventional vectors, QRS was also seen to have decreased significantly (P < 0.001). CONCLUSION: This study provides information that is essential in order to deal with the expected increase in the number of patients receiving MPP devices in the coming years. The results revealed different practices among centres, and establishing the optimal programming that can maximize the benefit of MPP remains a challenging issue. Compared with conventional CRT, MPP improved clinical status and resulted in an additional increase in EF. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrial.gov/. Unique identifier: NCT02606071.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda , Potenciais de Ação , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Disparidades em Assistência à Saúde , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Itália , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 40(12): 1350-1357, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29023821

RESUMO

AIMS: Left ventricular (LV) lead positioning at the site of delayed electrical activation is associated with better response to cardiac resynchronization therapy (CRT). We hypothesized that a long electrical conduction delay between right ventricular (RV) and coronary sinus (CS) leads during RV pacing (RLD index) is correlated with a better clinical outcome METHODS AND RESULTS: RLD is measured intraprocedurally, during RV pacing, as the time interval between the intracardiac electrograms of RV and CS leads. Initially, we did a prove-of-concept, feasibility, acute study in 97 patients who underwent CRT implantation. The CS lead position was assessed in the 40° right anterior oblique and 40° left anterior oblique views and assigned to one of 11 prespecified segments of a schematic eyeball depiction of the LV walls. Acute outcomes were QRS width during biventricular (BIV) pacing. The longest RLD were found in the basal and mid lateral segments; these accounted for 82% and 78%, respectively, of the total QRS width (%RLD). %RLD was inversely correlated with BIV-paced QRS (P  =  0.0001). A similar slope was present either in the 78 patients with preserved atrioventricular (AV) conduction and in the 19 without AV conduction (- 0.34 vs - 0.27, P  =  0.7). CONCLUSION: We showed that RLD can be used to guide lead placement at the time of CRT implantation and that it is correlated with BIV-QRS width, an indirect predictor of clinical outcome. Based on these findings we started the prospective, multicenter Optimal Pacing SITE 2 (OPSITE 2) trial with the objective to demonstrate a relationship between RLD and clinical outcomes assessed as death, hospitalization for heart failure, New York Heart Association class, and clinical composite score. The protocol is provided.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Seio Coronário , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Idoso , Terapia de Ressincronização Cardíaca/normas , Protocolos Clínicos , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Fatores de Tempo
12.
Eur Heart J Suppl ; 19(Suppl D): D229-D243, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28751844

RESUMO

Telemedicine has deeply innovated the field of emergency cardiology, particularly the treatment of acute myocardial infarction. The ability to record an ECG in the early prehospital phase, thus avoiding any delay in diagnosing myocardial infarction with direct transfer to the cath-lab for primary angioplasty, has proven to significantly reduce treatment times and mortality. This consensus document aims to analyse the available evidence and organizational models based on a support by telemedicine, focusing on technical requirements, education, and legal aspects.

13.
Circulation ; 131(24): 2114-9, 2015 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-25888682

RESUMO

BACKGROUND: Aortic dissection type A is a disease with high mortality. Iatrogenic aortic dissection after interventional procedures is infrequent, and prognostic data are scarce. Our objective was to analyze its incidence, patient profile, and long-term prognosis. METHODS AND RESULTS: Between 2000 and 2014, we retrospectively analyzed 74 patients with dissection of the ascending aorta. Clinical and procedural data were reviewed, and later, we performed a prospective clinical follow-up by telephone or in the office. The incidence of aortic dissection was 0.06%. Our patients, predominantly male (67.6%), had a mean age of 66.9±10.8 years. With multiple cardiovascular risk factors, the main reason for cardiac catheterization was an acute coronary syndrome (n=54). The complication was detected acutely in all, trying to engage the right coronary artery in 47 and the left main artery in 30 and after other maneuvers in 2, mostly complex therapeutic procedures (78.4%). A coronary artery was involved in 45 patients (60.8%). Thirty-five patients underwent an angioplasty and stent implantation; 3 had cardiac surgery; and 36 were managed conservatively. Two patients died of cardiogenic shock after the dissection. After a median follow-up of 51.2 months (range, 16.4-104.8 months), none of the remaining patients developed complications as a result of the dissection, progression, ischemia, pain, or dissection recurrence. CONCLUSIONS: Iatrogenic catheter dissection of the aorta is a rare complication that carries an excellent short- and long-term prognosis with the adoption of a conservative approach. When a coronary artery is involved as an entry point, it usually can be safely sealed with a stent with good long-term outcomes.


Assuntos
Aorta/lesões , Aneurisma Aórtico/etiologia , Dissecção Aórtica/etiologia , Cateterismo Cardíaco/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/diagnóstico , Idoso , Dissecção Aórtica/epidemiologia , Dissecção Aórtica/cirurgia , Dissecção Aórtica/terapia , Anticoagulantes/efeitos adversos , Aneurisma Aórtico/epidemiologia , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/terapia , Bases de Dados Factuais , Europa (Continente)/epidemiologia , Feminino , Fibrinolíticos/efeitos adversos , Seguimentos , Humanos , Doença Iatrogênica , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Stents , Resultado do Tratamento
14.
Eur J Public Health ; 26(5): 760-765, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27221608

RESUMO

BACKGROUND: Geographic and socioeconomic barriers may hinder fair access to healthcare. This study assesses geographic and socioeconomic disparities in access to reperfusion procedures in acute myocardial infarction (AMI) patients residing in Piedmont (Italy). METHODS: Coronary Care Units (CCUs) were geocoded with a geographic information system (GIS) and the shortest drive time from CCUs to patients' residence was computed and categorized as 0 to <20, 20 to <40 and ≥40 min. Using data on AMI emergency hospitalizations in 2004-2012, we employed a log-binomial regression model to evaluate the relation between drive time and use of Percutaneous Transluminal Coronary Angioplasty (PTCA) occurring within 2 days after a hospitalization for an episode of AMI, and whether this relation varied depending on the period of hospitalization. RESULTS: A total of 29% of all cases with a diagnosis of AMI (n = 66 097), were revascularized within 2 days from the index admission. The further AMI patients lived from CCUs, the less likely they were to receive revascularization: compared with distance <20 min, RRs were respectively 0.84 [95% CI 0.80-0.88] and 0.78 [95% CI 0.71-0.86]. Findings also showed that less educated people had a lower relative risk of being revascularized compared to more educated people (RR = 0.78; 95% CI = 0.74-0.82). Both inequalities have reduced in recent years. CONCLUSION: This study provides evidence of reduced geographical and socioeconomic differences in revascularization use over time. Geography and socioeconomic status should not determine the type of treatment received for life-threatening conditions such as AMI.


Assuntos
Angioplastia Coronária com Balão/estatística & dados numéricos , Geografia , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Infarto do Miocárdio/cirurgia , Classe Social , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Adulto Jovem
15.
Indian Pacing Electrophysiol J ; 16(2): 59-65, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27676162

RESUMO

BACKGROUND: AtrioVentricular (AV) and InterVentricular (VV) delay optimization can improve ventricular function in Cardiac Resynchronization Therapy (CRT) and is usually performed by means of echocardiography. St Jude Medical has developed an automated algorhythm which calculates the optimal AV and VV delays (QuickOpt™) based on Intracardiac ElectroGrams, (IEGM), within 2 min. So far, the efficacy of the algorhythm has been tested acutely with standard lead position at right ventricular (RV) apex. Aim of this project is to evaluate the algorhythm performance in the mid- and long-term with RV lead located in mid-septum. METHODS: AV and VV delays optimization data were collected in 13 centers using both echocardiographic and QuickOpt™ guidance in CRTD implanted patients provided with this algorhythm. Measurements of the aortic Velocity Time Integral (aVTI) were performed with both methods in a random order at pre-discharge, 6-month and 12-month follow-up. RESULTS: Fifty-three patients were studied (46 males; age 68 ± 10y; EF 28 ± 7%). Maximum aVTI obtained by echocardiography at different AV delays, were compared with aVTI acquired at AV delays suggested by QuickOpt. The AV Pearson correlations were 0.96 at pre-discharge, 0.95 and 0,98 at 6- and 12- month follow-up respectively. After programming optimal AV, the same approach was used to compare echocardiographic aVTI with aVTI corresponding to the VV values provided by QuickOpt. The VV Pearson Correlation were 0,92 at pre-discharge, 0,88 and 0.90 at 6-month and 12- month follow-up respectively. CONCLUSIONS: IEGM-based optimization provides comparable results with echocardiographic method (maximum aVTI) used as reference with mid-septum RV lead location.

16.
Int J Cardiol ; 405: 131933, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38437950

RESUMO

BACKGROUND: The impact of statin therapy on cardiovascular outcomes after ST-elevation acute myocardial infarction (STEMI) in real- world patients is understudied. AIMS: To identify predictors of low adherence and discontinuation to statin therapy within 6 months after STEMI and to estimate their impact on cardiovascular outcomes at one year follow-up. METHODS: We evaluated real-world adherence to statin therapy by comparing the number of bought tablets to the expected ones at 1 year follow-up through pharmacy registries. A total of 6043 STEMI patients admitted from 2012 to 2017 were enrolled in the FAST STEMI registry and followed up for 4,7 ± 1,6 years; 304 patients with intraprocedural and intrahospital deaths were excluded. The main outcomes evaluated were all-cause death, cardiovascular death, myocardial infarction, major and minor bleeding events, and ischemic stroke. The compliance cut-off chosen was 80% as mainly reported in literature. RESULTS: From a total of 5744 patients, 418 (7,2%) patients interrupted statin therapy within 6 months after STEMI, whereas 3337 (58,1%) presented >80% adherence to statin therapy. Statin optimal adherence (>80%) resulted as protective factor towards both cardiovascular (0.1% vs 4.6%; AdjHR 0.025, 95%CI 0.008-0.079, p < 0.001) and all-cause mortality (0.3% vs 13.4%; Adj HR 0.032, 95%CI 0.018-0.059, p < 0.001) at 1 year follow-up. Further, a significant reduction of ischemic stroke incidence (1% vs 2.5%, p = 0.001) was seen in the optimal adherent group. Statin discontinuation within 6 months after STEMI showed an increase of both cardiovascular (5% vs 1.7%; AdjHR 2.23; 95%CI 1.37-3.65; p = 0,001) and all-cause mortality (14.8% vs 5.1%, AdjHR 2.32; 95%CI 1.73-3.11; p ã€ˆ0,001) at 1 year follow-up. After multivariate analysis age over 75 years old, known ischemic cardiopathy and female gender resulted as predictors of therapy discontinuation. Age over 75 years old, chronic kidney disease, previous atrial fibrillation, vasculopathy, known ischemic cardiopathy were found to be predictors of low statin adherence. CONCLUSIONS: n our real-world registry low statin adherence and discontinuation therapy within 6 months after STEMI were independently associated to an increase of cardiovascular and all-cause mortality at 1 year follow-up. Low statin adherence led to higher rates of ischemic stroke.


Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases , Adesão à Medicação , Sistema de Registros , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Masculino , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Feminino , Adesão à Medicação/estatística & dados numéricos , Idoso , Pessoa de Meia-Idade , Seguimentos , Fatores de Tempo , Resultado do Tratamento
17.
Heart Rhythm ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493989

RESUMO

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

18.
Int J Cardiol ; 389: 131199, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37481001

RESUMO

BACKGROUND: Remote Monitoring (RM) is recognized for its ability to enhance the clinical management of patients with implantable cardiac monitor (ICM). This study aims to provide a comprehensive description of the arrhythmic episodes transmitted by a daily and automatic RM system from a cohort of ICM patients. METHODS: The study retrospectively analyzed daily transmissions from consecutive patients who had been implanted with a long-sensing vector ICM (BIOMONITOR III/IIIm) at four sites. All transmitted arrhythmic recordings were evaluated to determine whether they were true positive episodes or false positives (FP). RESULTS: A total of 14,136 episodes were transmitted from 119 patients (74.8% male, median age 62 years old) during a median follow-up of 371 days. The rate of arrhythmic episodes was 14.2 per patient-year (interquartile range: 1.8-126), with 97 patients (81.5%) experiencing at least one ICM activation. Fifty-five percent of episodes were identified as FP, and 67 patients (56.3%) had at least one inappropriate activation. The FP rate was 1.4 per patient-year (0-40). The best per-episode predictive positive values were observed for bradycardia and atrial fibrillation (0.595 and 0.553, respectively). Notably, the implementation of an algorithm designed to minimize false detections significantly reduced the prevalence of atrial fibrillation FP episodes (17.6% vs. 43.5%, p = 0.008). CONCLUSION: Daily and automatic RM appears to be a reliable tool for the comprehensive remote management of ICM patients. However, the number of arrhythmic episodes requiring review is high, and further improvements are needed to reduce FP and facilitate accurate interpretation of transmissions.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Eletrocardiografia Ambulatorial , Eletrocardiografia , Algoritmos
19.
Heart Rhythm ; 20(2): 233-240, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-37283031

RESUMO

BACKGROUND: Elevated resting heart rate is a risk factor for cardiovascular events. OBJECTIVE: The purpose of this study was to investigate the clinical significance of nocturnal heart rate (nHR) and 24-hour mean heart rate (24h-HR) obtained by continuous remote monitoring (RM) of implantable devices. METHODS: We analyzed daily-sampled trends of nHR, 24h-HR, and physical activity in patients on ß-blocker therapy for chronic heart failure and with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (CRT-Ds). Patients were grouped by average nHR and 24h-HR quartile during follow-up to estimate the respective incidence of nonarrhythmic death and device-treated ventricular tachycardia/fibrillation (VT/VF). RESULTS: The study cohort included 1330 patients (median age 69 years [interquartile range 61-77 years]; 41% [n = 550] with CRT-D; median follow-up 25 months [interquartile range 13-42 months]). Compared with patients in the lowest nHR quartile (≤57 beats/min) group, patients in the highest quartile group (>65 beats/min) had an increased risk of nonarrhythmic death (adjusted hazard ratio [AHR] 2.25; 95% confidence interval [CI] 1.13-4.50; P = .021) and VT/VF (AHR 1.98; 95% CI 1.40-2.79; P < .001) and were characterized by the lowest level of physical activity (P ≤ .0004 vs every other nHR quartiles). The highest 24h-HR quartile group (>75 beats/min) showed an increased risk of VT/VF (AHR 2.13; 95% CI 1.52-2.99; P < .001) and a weaker though significant association with nonarrhythmic mortality (AHR 1.80; 95% CI 1.00-3.22; P = .05) as compared with the lowest 24h-HR quartile group (≤65 beats/min). CONCLUSION: In remotely monitored patients with implantable cardioverter-defibrillator/CRT-D on ß-blocker therapy for heart failure, elevated heart rates (nHR >65 beats/min and 24h-HR >75 beats/min) were associated with increased mortality and VT/VF risk. nHR showed a stronger association than 24h-HR with worst prognosis and lowest physical activity.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Disfunção Ventricular Esquerda , Humanos , Pessoa de Meia-Idade , Idoso , Frequência Cardíaca , Prognóstico , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Arritmias Cardíacas/terapia , Fatores de Risco , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Disfunção Ventricular Esquerda/complicações
20.
Biology (Basel) ; 11(1)2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-35053117

RESUMO

AIMS: The utilization of remote monitoring platforms was recommended amidst the COVID-19 pandemic. The HeartLogic index combines multiple implantable cardioverter defibrillator (ICD) sensors and has proved to be a predictor of impending heart failure (HF) decompensation. We examined how multiple ICD sensors behave in the periods of anticipated restrictions pertaining to physical activity. METHODS: The HeartLogic feature was active in 349 ICD and cardiac resynchronization therapy ICD patients at 20 Italian centers. The period from 1 January to 19 July 2020, was divided into three phases: pre-lockdown (weeks 1-11), lockdown (weeks 12-20), post-lockdown (weeks 21-29). RESULTS: Immediately after the implementation of stay-at-home orders (week 12), we observed a significant drop in median activity level whereas there was no difference in the other contributing parameters. The median composite HeartLogic index increased at the end of the Lockdown. The weekly rate of alerts was significantly higher during the lockdown (1.56 alerts/week/100 pts, 95%CI: 1.15-2.06; IRR = 1.71, p = 0.014) and post-lockdown (1.37 alerts/week/100 pts, 95%CI: 0.99-1.84; IRR = 1.50, p = 0.072) than that reported in pre-lockdown (0.91 alerts/week/100 pts, 95%CI: 0.64-1.27). However, the median duration of alert state and the maximum index value did not change among phases, as well as the proportion of alerts followed by clinical actions at the centers and the proportion of alerts fully managed remotely. CONCLUSIONS: During the lockdown, the system detected a significant drop in the median activity level and generated a higher rate of alerts suggestive of worsening of the HF status.